1. Introduction
The Diymore XY12550S is a high-performance digital DC adjustable step-down power supply module designed for a wide range of applications. It features constant voltage (CV), constant current (CC), and constant power (CW) modes, along with Maximum Power Point Tracking (MPPT) for efficient solar charging. This manual provides detailed instructions for safe and effective use of the device.
2. Key Features
- Supports firmware upgrade, MPPT solar charging, and serial communication.
- 1.8-inch high-brightness full-color LCD screen with full viewing angle, customizable color scheme, and 4-way rotation.
- Features input reverse polarity protection and output reverse current protection for comprehensive safety.
- The display board uses a gold-plated design for better conductivity, oxidation resistance, and durability.
- Two intelligent temperature-controlled PWM fans with variable speed and a large heat sink for low noise and efficient cooling.
- A common-mode inductor is used for the input, significantly reducing input ripple and achieving low output ripple.
- Independent dual serial ports, serial port TTL and on-board 485.
- Supports network control via PC host computer and mobile APP (Sinilink control for Android/iOS).
- Supports global weather systems and global WiFi time synchronization systems.
- One-to-many group control via 485 bus.
- Integrated fire-retardant shell with double-buckle design.
- Silicone buttons with indicator lights.
3. Product Specifications
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product Name | DC buck-power supply | Model | XY12550S |
| Input Voltage | 12.00~140.0V | Output Voltage | 0~125.0V |
| Output Current | 0~50.00A | Accuracy of Voltage | ±0.5%+1 word |
| Power Output | 6250W | Accuracy of Current | ±0.5%+3 word |
| Resolution of Voltage | 0.01V | Resolution of Current | 0.01A |
| Storage Data Group | 10 groups | Soft Start | YES |
| Screen Size | 1.8-Inch Full-View High-Brightness True Color LCD | ||
| Output Ripple Typical Value | vpp-300mv | ||
| MPPT Function | Support MPPT solar charging | Buzzer | YES |
| Efficiency of Conversion | About 95% | Number of Buttons | 5 |
| Screen Instrument Size | 86*50*45mm | Bare Board Weight with Packaging | 640g |
| Bare Board Size | 170*108*53mm | Product Weight with Packaging | 715g |
| Bare Board Package | 195*120*67mm | ||
| Product Package | 250*120*73mm |
| Protection Type | Description / Default Value |
|---|---|
| Anti-reverse | YES (Input reverse polarity protection, output reverse current protection) |
| Input Under-Voltage (LVP) | 10-145.0V, default 10V |
| Over-Voltage (OVP) | 0-130.0V, default 130.0V |
| Over-Current (OCP) | 0-52A, default 52A |
| Over-Power (OPP) | 0-6500W, default 6300W |
| Over-Temperature (OTP) | 60-110°C, default 110°C |
| Over-Time Out (OHP) | 1 minute - 99 hours 59 minutes, off by default |
| Over-Capacity (OAH) | 0-4200KAh, off by default |
| Over-Energy (OWH) | 0-4200KWh, off by default |
| EXT Over-Temperature (ETP) | 0-110°C, off by default |
For a visual overview of specifications and protection mechanisms, refer to the image below:

4. Safety Precautions
- Do not connect AC power to the input, especially 220V mains power.
- The maximum input voltage should not exceed 145V; 140V is recommended.
- Do not reverse the polarity of the input or output connections.
- This is a DC-DC converter; the maximum output voltage = input voltage * 0.945.
- Ensure the unit is OFF before connecting any battery or load.
- Avoid reverse polarity connection to prevent device damage or fire hazards.
- Turn on the output ONLY after the battery icon appears on the screen to initiate charging (when using MPPT).

5. Setup
5.1 Physical Installation and Connections
The XY12550S module consists of a main power board and a separate display panel. The display panel can be integrated into an enclosure. Refer to the dimensions below for proper installation:

Connect the display panel to the main power board using the provided cable. Ensure all connections are secure and correct polarity is observed.

5.2 Bare Board Configuration (Optional)
The bare board can be used independently. It supports MPPT and analog 0.3-10V control, along with serial communication and on-board 485 communication (both can be used simultaneously). The output voltage is adjustable from 0-85V, and the output current from 0-50A.
When purchasing a bare device, switches, potentiometers, and dial switches will be welded on. If a set with a screen meter is purchased, they are not welded by default.

To enter potentiometer mode, flip the MPPT ON/OFF switch up to light up the green indicator light. This mode allows output voltage to be controlled via potentiometer and constant current via dip switch. The advantage of using the dip switch for constant current is to prevent multimeter burnout.
6. Operating Instructions
6.1 Universal Button Functions
The display panel features five buttons and a rotary encoder for control:
- VSET Button: Short Press to set Constant Voltage (CV). Long Press to quickly call up data set M1.
- SW Button: Short Press to enter quick settings. Long Press to enable four-way screen rotation.
- ISET Button: Short Press to set Constant Current (CC). Long Press to enter or exit the data group settings UI.
- Encoder Button: Short Press for Shift. Long Press to Lock the button.
- Power Button (ON/OFF): Short Press to turn power output on/off. Long Press to shut down.

6.2 Setting Voltage and Current
There are three ways to set voltage and current:
- Quick Setup Mode:
- Press the V-SET/I-SET button briefly to enter voltage/current setting mode.
- Use the SW button or encoder button to move between digits.
- Rotate the encoder to adjust the voltage/current value. Once set, press V-SET/I-SET briefly to save and exit.
- Encoder Mode:
- Press the encoder button briefly to activate the parameter (voltage/current) you want to set.
- Press the encoder button to switch between full selection and digit selection. In full selection, all digits are highlighted. Rotate the encoder to switch between setting voltage or current. In digit selection, the selected digit is highlighted. Rotate the encoder to adjust the value.
- To finish, either hold the encoder button/SW button for 2 seconds or wait 6 seconds without any button press. All settings are saved automatically.
- Remote Control Mode:
Use an infrared remote control or 433M wireless remote control module to set voltage and current directly with the remote's numeric keypad.

6.3 CV, CC, CW Features Introduction
- Constant Voltage (CV) & Constant Current (CC): When the constant power function is off, the power supply automatically switches between CV and CC based on the load. If load current is less than set constant current, it operates in CV mode (output voltage = set CV, current is adaptive).
- Constant Power (CW): When enabled, the constant current defaults to maximum, and the constant voltage acts as initial voltage. The device calculates load resistance (R=U/I) and then adjusts voltage/current to maintain constant power (P=U/R).
Constant Power Switch and Constant Power Value Setting:
- In the system parameter settings UI, select the CW option. Turn ON to enable constant power, and turn OFF to disable it.
- After enabling constant power, press ISET briefly on the main interface to modify the value of constant power.

6.4 Data Set Management
- Lock Function: Hold the encoder button for more than 2 seconds to lock/unlock buttons and prevent accidental changes.
- Quickly Recall Data Sets: Hold the V-SET button to quickly load M1 data set. To select other data sets, hold the I-SET button to open the selection window, rotate the encoder to choose, then press I-SET or SW/encoder button to load.
- Quickly Adjust System Parameters: On the main screen, briefly press the SW button to select a status bar parameter. Rotate the encoder to switch parameters. Briefly press SW or encoder button to adjust or open the parameter setting interface. Use the encoder to set the value. To save, hold SW/encoder button for 6 seconds without operation.

6.5 Display Customization and Rotation
The 1.8-inch full-color LCD screen supports 8 color options, allowing users to customize the interface colors. The display also supports 4-way rotation. Long press the SW button on the main UI to enable four-way rotation.


6.6 Network and Remote Control
The module supports network control via LAN penetration, real-time communication, and remote control via an external network with unlimited distance. It also supports email notifications and cloud record keeping. Control is possible through a PC host computer or the mobile Sinilink APP (Android/iOS).

The device also supports global weather systems and WiFi time synchronization.

Remote control is also possible using an infrared remote control or a 433M wireless remote control module.

The multi-serial port host software allows connectivity of up to 247 devices to a single serial port, enabling control of over a thousand devices in a clustered environment. It also supports batch control and administrative accounts for secure access.

6.7 Group Control
The digital control panel supports one-to-many group control. By turning on the group control switch on the panel, you can collectively manage power supply activation/deactivation, voltage/current settings for multiple devices via the 485 bus.
Activating Group Control Function: On the main power supply interface, briefly press the SW button to select the right status bar. Rotate the encoder to choose the group control switch icon, then briefly press the encoder button to open the selection dialog. Press the SW or encoder button to select and rotate the encoder to ON to enable group control mode. When setting voltage, current, or power on/off, the changes will automatically synchronize to all devices on the 485 bus (Note: Device addresses on the bus must be unique). Hold the SW button or wait 6 seconds without operation to exit and save settings automatically.

Communication control can also be achieved with a separate bare board, providing a low-cost solution with independent dual serial ports (TTL and 485).

7. MPPT Solar Charging
The XY12550S supports MPPT solar charging, allowing it to charge various rechargeable batteries with reverse current protection. It features automatic stop when fully charged and automatic charging at low battery, enabling intelligent battery charging management.
An external temperature probe can be connected for over-temperature protection. Attach the external temperature probe to the battery, and the unit will automatically stop charging if over-temperature is detected.
With BCH automatic charging and BTF full-charge auto-stop functions, unattended operation is possible.

Precaution: Ensure the unit is OFF before connecting the battery. Avoid reverse polarity connection to prevent device damage or fire hazards. Turn on the output ONLY after the battery icon appears on the screen to initiate charging.
8. Firmware Upgrade
The device supports firmware upgrades to experience new features. Currently, it only supports firmware upgrade through the WiFi module. Future upgrades will also be possible through the multi-serial port host computer software (under development).

Note: Do not power off during the product upgrade process. If the product upgrade fails, you can press and hold the power button to power on the product and force it into the upgrade mode.
9. User Tips
- For optimal performance and longevity, ensure proper ventilation around the module, especially during high-power operation. The dual-fan thermal architecture is designed for efficient cooling, but adequate airflow is still important.
- When using the remote control, ensure the remote control module is properly connected and within range for reliable operation.
- Regularly check for firmware updates via the WiFi module to benefit from new features and improvements.
- Always double-check wiring connections, especially polarity, before powering on the device to prevent damage.
10. Troubleshooting
- No Power/Display: Check input voltage connections and ensure they are within the specified range (12.00~140.0V). Verify the power switch is ON.
- Output Not Activating: Ensure the output is enabled via the ON/OFF button. Check for any active protection mechanisms (LVP, OVP, OCP, etc.) indicated on the display.
- Inaccurate Readings: Verify all connections are secure. If using the bare board, ensure dip switch settings for current are correct.
- MPPT Not Functioning: Ensure the MPPT ON/OFF switch is in the correct position (green indicator light). Check battery connections and ensure the battery icon appears on the screen before enabling output.
- Communication Issues: Verify serial port connections. Ensure the correct software/APP is being used and configured properly for Modbus or network control.
- Firmware Upgrade Failure: Do not power off. Press and hold the power button to force the device into upgrade mode and retry the update.
11. Maintenance
- Keep the device clean and free from dust and debris to ensure proper cooling and prevent short circuits.
- Avoid exposing the device to moisture or extreme temperatures.
- Periodically check all wiring connections for tightness and signs of wear.
- The dual intelligent temperature-controlled PWM fans are designed for extended lifespan, but ensure their vents are not obstructed.
12. Package Contents
- Package A: Adjustable power supply ×1, Display panel ×1, Cables ×2
- Package B: Adjustable power supply ×1 (Base board can be used independently)
Note: The specific package contents depend on the purchased variant.