1. Product Introduction
Welcome to the POW-LTW-15A Solar Controller. This controller embodies PowMr's commitment to innovation in solar technology, designed for small-scale solar system applications. It features advanced CNC technology, an LCD display, and automated operation. Utilizing an MPPT charging algorithm and advanced control technology, it extends the lifespan of energy storage system batteries.
The controller precisely manages charging and discharging processes, optimizing battery performance and enhancing overall system reliability. It includes self-diagnostic and electronic protection functions to prevent damage from installation errors or system malfunctions.
With a compact structure and precise internal components, the POW-LTW-15A offers outstanding performance, balancing size, weight, and functionality. Its plug-and-play wiring simplifies installation, and a user-friendly customizable interface allows for flexible configuration and system expansion. A dedicated button enables quick battery type configuration.
Choosing the POW-LTW-15A Solar Controller provides an efficient, sustainable, and secure energy management solution.
2. Important Safety Guidelines
Warning: Please carefully read and adhere to all safety instructions.
- Before installing and operating, read the user manual and keep it for future reference.
- Installation or operation by individuals without strict guidance and supervision is not permitted if they lack relevant knowledge, experience, or capability, or have impaired physical, sensory, or intellectual capabilities.
Controller Installation and Operation Safety
- This controller has no user-serviceable parts. Do not dismantle or attempt to repair it.
- Install the controller in an environment with good natural ventilation and sufficient spacing.
- Mount the controller on a non-flammable wall, ensuring no flammable materials are nearby. Temperature elevation during operation is normal.
- Install the controller indoors, free from direct sunlight, rainwater, humidity, and dust, and away from flammable liquids or gases.
- Do not install or operate the controller on top of or directly above batteries, or in enclosed spaces containing batteries, as batteries release explosive gases.
- Do not place any other items on top of the controller.
Battery Installation and Charging Safety
- Install and charge batteries in a well-ventilated or exhaust environment.
- Ensure no sources of ignition are around batteries, as they release explosive gases.
- Battery acid is corrosive; if contact occurs, immediately rinse with clean water.
- Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
3. Setup (Installation and Wiring)
3.1 Unboxing and Inspection
Before unboxing, check for packaging damage. After unboxing, inspect contents for damage or missing items. The package should contain:
- Controller
- User Manual
- SAE cables
3.2 Selecting Installation Location
Choose a suitable and safe installation location considering the following:
- Good natural ventilation/exhaust.
- Avoid direct sunlight.
- Sufficient clearance around the controller (minimum 75mm for top, bottom, and sides).
- Mount on a non-flammable wall, away from flammable materials.
- Indoor use only, free from rainwater, humidity, dust, flammable liquids or gases.

Scan this QR code for the operating guide.
3.3 Wiring Precautions
- Follow the wiring sequence: Battery > Photovoltaic Input.
- Ensure all cables are tightened to limit transition resistance. Use cables of appropriate size according to the current rating.
3.4 Wiring Guidelines
Follow these steps to wire the controller:
- Connect one end of the SAE cable to the battery. If cable length is insufficient, use an extension cable. Strictly differentiate between positive and negative terminals.
- Connect the SAE connector on the battery end to allow the controller to access the battery power supply. Ensure correct polarity before connecting.
- Connect the photovoltaic array to the controller's built-in MC4 connector to access the photovoltaic input power.

Controller connected to a battery.

Photovoltaic module connection diagrams (parallel and series).
NOTE:
- Follow the wiring sequence: Battery > Photovoltaic Input. Incorrect wiring sequence may cause irreversible damage to the controller.
- Connect positive cable terminals to positive ports and negative cable terminals to negative ports.
4. Operating Guide
4.1 Button Introduction

Front view of the PowMr controller showing LCD and control buttons.
| Button | Action | Function |
|---|---|---|
| SET/▲ | Short Press (Browse Mode) | Enter the next page. |
| Long Press (Browse Mode) | Enter settings. | |
| SET/▲ | Short Press (Setting Mode) | Navigate to the next option/increase value. |
| Long Press (Setting Mode) | Confirm the option. | |
| BAT/▼ | Short Press | Enter battery type settings/confirm and save battery type. |
| Long Press | Navigate to the next battery type option. | |
| ▼ | (General) | Return to the previous page/previous option/decrease value. |
4.2 Interface Icon Explanation
| Icon | Description |
|---|---|
| SEL | Sealed Lead-Acid Battery |
| GEL | Gel Sealed Lead-Acid Battery |
| F04 | 4-Cell Lithium Iron Phosphate Battery |
| F08 | 8-Cell Lithium Iron Phosphate Battery |
| USE | Custom Battery Type |
| ☀️ | Current Photovoltaic Input Present |
| 🌙 | No Current Photovoltaic Input Detected |
| 🔋 | Battery Level |
| 88.8 V | Sequentially displays: current battery voltage, charging current, photovoltaic input power, device temperature, calibration voltage, system voltage, boost charging voltage, float charging voltage, MPP tracking return voltage. When a device fault occurs, the fault code will be displayed (see Troubleshooting). |
4.3 Display Page Overview
Use the ▲ or ▼ buttons to toggle through the display screens. The contents include:
- Current Battery Voltage
- Charging Current
- PV Input Wattage
- System Voltage
- Calibration Voltage
- Device Temperature
- Boost Charging Voltage
- Float Charging Voltage
- MPP Tracking Return Voltage
Video demonstrating the wiring and display operation of the PowMr MPPT controller.
4.4 Setting Guide
Battery Type Setting
- After connecting and starting the controller, long-press the BAT button to enter the battery type setting interface.
- Short-press the BAT button to toggle through battery types (SEL, GEL, F04, F08, USE).
- After selecting, long-press the BAT button to confirm and save the battery type.
Note on Battery Types:
- If SEL, GEL, F04, or F08 is selected, the controller automatically detects system voltage and uses default charging parameters.
- If USE (User Defined) is selected, you can set system voltage, boost charging voltage, float charging voltage, and MPPT tracking return voltage.
Charging Parameter Setting - Button Operation Guide:
- Use the ▲ or ▼ keys to navigate the interface, then long-press the SET button to enter.
- Use the ▲ or ▼ keys to increase or decrease voltage values. Press SET to confirm and save the settings.
System Voltage Setting Interface
System voltage options: 12V/24V.
Boost Charging Voltage Setting Interface
Default: 14.4V, setting range: 9.0~17.0V, step: 0.1V.
Float Charging Voltage Setting Interface
Default: 13.8V, setting range: 9.0~17.0V, step: 0.1V.
MPP Tracking Return Voltage Setting Interface
Default: 13.2V, setting range: 9.0~17.0V, step: 0.1V.
Calibration Voltage Setting
If there is a discrepancy between the battery voltage monitored by the controller and a multimeter reading, use this setting to calibrate the battery voltage.
4.5 Default Charging Parameters for Different Battery Types
| Parameters | SEL | GEL | F04 | F08 | USE |
|---|---|---|---|---|---|
| Boost Charging Voltage | 14.4V | 14.2V | 14.4V | 28.8V | 9.0~17.0V |
| Float Charging Voltage | 13.8V | 13.8V | 14.0V | 28.0V | 9.0~17.0V |
| MPP Tracking Return Voltage | 13.2V | 13.2V | 13.2V | 26.4V | 9.0~17.0V |
NOTE:
- Charging parameters for lead-acid batteries and user-defined battery types are for 12V system voltage. For 24V systems, multiply these values by 2.
- When connecting lead-acid batteries or user-defined battery types with a 24V system, the actual charging voltage will be twice the displayed voltage value.
Lead-Acid Battery Charging Three Stages:
The charging process for lead-acid batteries involves three stages: Bulk Charging, Boost Charging, and Float Charging.

Diagram illustrating the three-stage charging curve for lead-acid batteries.
Lithium Battery Charging Two Stages:
The charging process for lithium batteries involves two stages: Bulk Charging and Boost Charging.

Diagram illustrating the two-stage charging curve for lithium batteries.
5. Protection Functions
The controller features multiple protection mechanisms to ensure safe and reliable operation:

Visual representation of the 8 protection systems.
| Protection | Description |
|---|---|
| Photovoltaic Array Short Circuit | Controller stops charging; resumes when short circuit is rectified. |
| Photovoltaic Input Overcurrent | Controller limits charging current to maximum rated battery current, preventing peak power operation from PV array. |
| Photovoltaic Polarity Reversal | Controller will not operate; normal operation resumes upon correcting connection. |
| Battery Polarity Reversal | Controller will not operate; normal operation resumes upon correcting connection. |
| Overtemperature | Reduces charging current if heatsink exceeds 59.5°C; shuts down if temperature exceeds 80°C. |
6. Troubleshooting
The controller displays fault codes to indicate issues. Refer to the table below for explanations and resolutions.
| Fault Code | Description | Explanation/Resolution |
|---|---|---|
| E60 | Overtemperature Protection | Alarm triggered and charging stops if temperature exceeds 85°C. Clears and resumes charging when temperature drops below 75°C. |
| E63 | Battery Voltage Too High | Charging stops; resumes when battery voltage returns to normal. |
| E71 | Photovoltaic Input Voltage Too High | Alarm for 12V systems if PV input > 30V; for 24V systems if PV input > 60V. Resolution: Change series/parallel connection or reduce solar panels to lower PV array voltage. |
| E73 | Charging Current Too High | Reduce photovoltaic input power by reducing the number of solar panels. |
7. Specifications
| Model: POW-LTW-15A | |
|---|---|
| Photovoltaic Input Parameters | |
| Maximum Input Power (12V System) | 180W |
| Maximum Input Power (24V System) | 360W |
| Input Voltage Range (12V System) | <30V |
| Input Voltage Range (24V System) | <60V |
| Battery Charging Parameters | |
| Charging Technology | MPPT |
| Charging Algorithm | 3 Stages |
| Nominal System Voltage | 12V/24V |
| Rated Charging Current | 15A |
| Conversion Efficiency | ≤98% |
| Max. Power Point Tracking Efficiency | >99% |
| Self-Consumption | 12V 20mA, 24V 25mA |
| Environmental Parameters | |
| Operating Temperature Range | -35°C ~ +75°C |
| Humidity Range | ≤95% Non-condensing |
| Altitude | <3000m |
| General Parameters | |
| Protection Level | IP32 |
| Dimensions (excluding built-in wiring) | 129x78x30mm |
| Net Weight | 237g |
8. User Tips
- Battery Compatibility: While the controller supports various battery types, including lithium, always ensure your battery's specifications match the controller's capabilities. Pay close attention to temperature restrictions, especially for lithium batteries (do not charge below 0°C).
- Setting Battery Type: The "One-Key" battery type configuration simplifies setup. Long-press the BAT button to enter settings, then short-press to cycle through types (SEL, GEL, F04, F08, USE), and long-press again to confirm. For custom settings (USE), refer to the detailed "Charging Parameter Setting" guide.
- Wiring Sequence is Crucial: Always connect the battery first, then the photovoltaic input. Incorrect wiring sequence can cause irreversible damage. Double-check polarity.
- Monitor Display: Utilize the display page overview to monitor current battery voltage, charging current, PV input wattage, system voltage, calibration voltage, device temperature, and charging voltages. This helps in understanding system performance and diagnosing issues.
9. Maintenance
Perform the following checks and maintenance tasks at least twice a year for optimal operation:
- Ensure the controller is securely installed in a clean and dry environment.
- Ensure proper airflow around the controller and clean any dust or debris from the heat sink.
- Inspect all exposed wires for insulation damage (sunlight, friction, dryness, insects, rodents). Repair or replace damaged wires.
- Tighten all terminals and check for loose, broken, or burnt cable connections.
- Confirm that all components of the system are properly grounded.
- Ensure all terminals are free from corrosion, insulation damage, high temperature, or signs of burning/discoloration, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. Clean if necessary.
Warning: Risk of electric shock!
Before performing maintenance, ensure all power sources are switched off. Follow relevant check and operation points.
10. Warranty and Support
Disclaimer
The company reserves the right to disclaim liability for quality assurance under the following circumstances:
- Damage caused by improper transportation, incorrect storage, installation, or usage.
- Damage caused by non-professionals or untrained personnel installing/using the equipment.
- Damage resulting from failure to adhere to instructions and safety warnings in this document.
- Damage caused by operation in environments not meeting specified requirements.
- Damage resulting from operation beyond specified technical parameters.
- Damage caused by unauthorized dismantling, alteration, or software modification.
- Damage caused by exceptional natural circumstances (force majeure) like lightning, earthquakes, fires, storms.
- Damage resulting from failure to follow local standards and regulations during installation and operation.
- Products beyond the warranty period.
Contact Information
For technical support or inquiries, please contact:
- Brand: PowMr
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China