SCHMERSAL SRB401LC-24V 101179969

Contents

SCHMERSAL SRB401LC-24V 101179969 Security Relay User Manual

Model: SRB401LC-24V 101179969

Brand: SCHMERSAL

1. Product Overview

The SCHMERSAL SRB401LC-24V 101179969 is a safety relay designed for monitoring safety functions in industrial applications. It is crucial for ensuring the safe operation of machinery by monitoring emergency stop buttons, safety gates, and other safety-related components. This manual provides essential information for the safe and efficient use of the device.

SCHMERSAL SRB401LC-24V Security Relay front view with terminal markings
Figure 1: SCHMERSAL SRB401LC-24V Security Relay. Visible markings include 'SRB 401LC-24V', 'SCHMERSAL PROTECT', 'Ub', 'Ui', 'K1', 'K2', and terminal numbers '13', '14', '23', '24'.

2. Safety Instructions

WARNING: Improper installation or operation of this safety device can lead to severe injury or death. Always adhere to local and national safety regulations, and consult qualified personnel for installation and maintenance.

  • Ensure power is disconnected before installation, wiring, or maintenance.
  • Only qualified electricians or trained personnel should install and service this device.
  • Verify all wiring connections are correct and secure before applying power.
  • Regularly test the safety function of the relay as part of a comprehensive safety system.
  • Do not bypass or tamper with safety devices.

3. Setup and Installation

3.1 Mounting

The SRB401LC-24V is typically designed for DIN rail mounting. Ensure the mounting surface is stable and free from excessive vibration. Mount the device in an enclosure that provides adequate protection against environmental factors (dust, moisture, temperature extremes) as per its IP rating.

3.2 Wiring

Refer to the product label and the manufacturer's detailed wiring diagram for precise connection instructions. General terminal designations are as follows (refer to Figure 1 for visual aid):

  • Ub (Supply Voltage): Connect the 24V DC power supply to these terminals. Ensure correct polarity.
  • Ui (Input Voltage): These terminals are typically for monitoring safety inputs such as emergency stop buttons or safety gate switches.
  • K1, K2 (Control Inputs): These may be used for specific control functions or feedback loops within the safety circuit.
  • 13, 14, 23, 24 (Output Contacts): These are typically normally open (NO) safety contacts that close when the safety circuit is clear and the relay is enabled. These contacts are used to control the power to hazardous machinery.

Use appropriate wire gauges for all connections to prevent overheating and ensure reliable operation. All connections must be tight and secure.

3.3 Initial Power-Up

After completing all wiring and mounting, double-check all connections. Apply 24V DC power to the device. Observe any status indicators (LEDs) on the relay, which typically indicate power, input status, and output status. Consult the manufacturer's datasheet for specific LED behavior.

4. Operating Instructions

The SCHMERSAL SRB401LC-24V security relay operates by monitoring the state of connected safety devices. When all safety inputs are in a safe condition (e.g., emergency stop button released, safety gate closed), the relay's output contacts (13-14, 23-24) will close, allowing power to flow to the controlled machinery. If any safety input detects an unsafe condition, the relay's output contacts will open, immediately removing power from the machinery and bringing it to a safe stop.

The relay typically features a reset function, which may be automatic or manual. For manual reset, a dedicated reset button or signal is required to re-enable the outputs after a safety event has occurred and the unsafe condition has been resolved.

5. Maintenance

Regular maintenance is essential to ensure the continued reliability and safety of the SRB401LC-24V security relay.

  • Visual Inspection: Periodically inspect the relay for any signs of physical damage, loose connections, or discoloration.
  • Cleaning: Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Functional Testing: Perform routine functional tests of the entire safety circuit, including the relay, according to your facility's safety protocols and relevant standards (e.g., ISO 13849, IEC 62061).
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges.

6. Troubleshooting

If the security relay is not functioning as expected, consider the following troubleshooting steps:

  • No Power: Check the 24V DC power supply connections to Ub terminals. Verify the power source is active.
  • Outputs Not Activating:
    • Ensure all safety inputs (Ui, K1, K2) are in a safe state.
    • Check for any fault indicators (LEDs) on the relay.
    • If a manual reset is required, ensure it has been performed after clearing any fault.
    • Verify the wiring of all inputs and outputs for continuity and correct connection.
  • Unexpected Shutdown: This indicates a safety input has detected an unsafe condition. Identify and rectify the cause of the safety event.
  • Loose Connections: Re-tighten all terminal screws.

If the problem persists after these checks, contact a qualified technician or SCHMERSAL technical support.

7. Specifications

Feature Specification
Model Number SRB401LC-24V 101179969
Brand SCHMERSAL
Function Safety/Security Relay
Supply Voltage 24V (DC, as indicated by model name)
Origin Mainland China
Approx. Package Dimensions (L x W x H) 20 cm x 20 cm x 20 cm
Approx. Package Weight 0.45 kg

Note: For detailed technical specifications, including current ratings, response times, and safety integrity levels (SIL/PL), please refer to the official SCHMERSAL datasheet for the SRB401LC-24V.

8. User Tips

  • System Design: Always integrate safety relays into a complete safety system designed by competent personnel, considering all relevant safety standards.
  • Documentation: Keep a copy of the manufacturer's full datasheet and wiring diagrams readily available for reference.
  • Training: Ensure all personnel interacting with the safety system are adequately trained on its operation and safety procedures.

9. Warranty and Support

For information regarding product warranty, technical support, or service, please refer to the official SCHMERSAL website or contact your authorized distributor. Ensure you have the model number (SRB401LC-24V 101179969) and any relevant purchase details available when seeking support.

© 2024 SCHMERSAL. All rights reserved. Information subject to change without notice.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.