1. Introduction
The PORTXVNSA SA5 is a compact, multi-functional handheld device designed for both spectrum analysis and signal generation. Featuring a 4-inch IPS LCD and a robust 5000mAh battery, it offers portability and precision for various electrical and RF testing applications. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your SA5 device.


Video 1: An overview of the PORTXVNSA SA5 Multi-Function Handheld Spectrum Analyzer.
2. Package Contents
Please check the package contents upon receipt to ensure all items are present and undamaged. The SA5 is available in two kits:
Standard Kit:
- Main unit (with 5000mAh battery, 4-inch display) x 1
- USB Type-C data cable x 1
- 30cm RG405 SMAJB2/SMAJB2 RF connecting cable x 2
- SMA-SMA barrel connector x 1
- Antenna with SMA connector x 1
- Lanyard touch pad x 1
- Touch pen x 1
Kit 2 (with 32GB MicroSD Card):
- Main unit (with 5000mAh battery, 4-inch display) x 1
- USB Type-C data cable x 1
- 30cm RG405 SMAJB2/SMAJB2 RF cable x 2
- SMA-SMA barrel connector x 1
- Antenna with SMA connector x 1
- Lanyard touch pad x 1
- Touch pen x 1
- 32GB MicroSD card (pre-inserted into main unit) x 1

3. Setup and Initial Use
3.1 Charging the Device
The SA5 comes with a built-in 5000mAh rechargeable battery. For optimal performance, fully charge the device before first use. A full charge provides approximately 10 hours of portable use.
- Connect the provided USB Type-C data cable to the Type-C port on the SA5.
- Connect the other end of the cable to a compatible USB power adapter (not included) or a computer's USB port.
- The device will indicate charging status on the screen.

3.2 MicroSD Card Installation (if applicable)
If your kit did not include a pre-inserted 32GB MicroSD card, you can install one for data storage.
- Locate the SD card interface on the side of the SA5 device.
- Gently insert a MicroSD card (up to 32GB recommended) into the slot until it clicks into place.
- To remove, push the card in slightly until it springs out.
3.3 Powering On/Off
The SA5 features an on/off switch for easy control.
- To power on, slide the switch to the "ON" position.
- To power off, slide the switch to the "OFF" position.

3.4 Connecting Accessories
Depending on your measurement needs, connect the appropriate accessories:
- Antenna: Screw the provided antenna into the RF input port for general signal reception.
- RF Cables: Use the 30cm RG405 SMAJB2/SMAJB2 RF connecting cables to connect the SA5 to other RF equipment.
- SMA-SMA Barrel Connector: Use this connector to join two SMA cables or adapt an SMA connection.
4. Operating Instructions
The SA5 features a 4-inch IPS LCD touch screen and a rotary knob for navigation and control.
4.1 Basic Navigation
- Touch Screen: Use the touch pen or your finger to interact with on-screen menus and input data.
- Rotary Knob: Turn the knob to scroll through options or adjust values. Press the knob to confirm selections.
4.2 Spectrum Analyzer Function
The SA5 operates as a spectrum analyzer with the following capabilities:
- Frequency Range: 0.1-800MHz in normal mode.
- Ultra Mode: When Ultra mode is enabled, it provides level calibrated signal frequencies up to 5.3GHz and can observe signal frequencies up to 12GHz.
- Spectrum Display: Displays up to 450 points and shows 4 independently configurable curves.
- Resolution Bandpass Filter: The resolution bandpass filter ranges from 200Hz to 850kHz, allowing for detailed signal analysis.
- Optional LNA: Features a built-in 20dB Low Noise Amplifier (LNA) for improved sensitivity.
- Input Attenuator: The adjustable range of the step attenuator is 0dB to 31dB. Note that this is not compatible with LNA when active.
4.3 Signal Generator Function
When not in spectrum analyzer mode, the SA5 can function as a signal generator:
- Sine Wave Output: Generates sine waves ranging from 0.1-800MHz.
- Square Wave Output: Generates square waves up to 4.4GHz.
- RF Test Signals: Can output RF test signals up to 5.3GHz.
4.4 Calibration
The device includes a built-in calibration signal generator for automatic self-testing and input calibration, ensuring accurate measurements.

4.5 PC Connection
The SA5 can be connected to a PC via USB for enhanced control and data transfer.
- Connect the SA5 to your computer using the provided USB Type-C cable.
- The device can then function as a PC-controlled spectrum analyzer or signal generator.
- Data, settings, and screenshots stored on the MicroSD card can be directly transferred to the computer.

5. Maintenance
5.1 Cleaning
- Wipe the device with a soft, dry cloth.
- Do not use abrasive cleaners or solvents, as they may damage the screen or casing.
- Keep the ports free of dust and debris.
5.2 Battery Care
- To prolong battery life, avoid fully discharging the device frequently.
- Charge the device regularly, even if not in use, to maintain battery health.
- Store the device in a cool, dry place when not in use for extended periods.
5.3 Storage
- Store the SA5 in a protective case to prevent physical damage.
- Ensure the MicroSD card is properly inserted or removed before storage.
- Keep the device away from extreme temperatures and humidity.
6. Troubleshooting
6.1 Device Not Powering On
- Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and allow it to charge for at least 30 minutes.
- Verify the on/off switch is in the "ON" position.
6.2 Display Issues
- If the screen is unresponsive, try restarting the device.
- Ensure the screen is clean and free from moisture or debris that might interfere with touch input.
6.3 Inaccurate Measurements
- Perform a calibration using the built-in calibration signal generator.
- Check all cable connections for proper seating and integrity.
- Ensure the correct input attenuator settings are applied for your measurement scenario.
- Verify that the LNA is not active if the input attenuator is in use, as they are not compatible simultaneously.
6.4 PC Connection Problems
- Ensure the USB Type-C cable is securely connected to both the SA5 and the PC.
- Try a different USB port on your computer.
- Check if necessary drivers are installed on your PC (refer to manufacturer's website for driver downloads if needed).
7. Specifications
The following table details the technical specifications of the PORTXVNSA SA5 Multi-Function Handheld Spectrum Analyzer:

| Specification | Details |
|---|---|
| Input Frequency Range | 100kHz to 800MHz in normal mode, up to 6GHz with ULTRA mode enabled |
| Input Impedance | 50 ohm when input attenuation set to 10dB or more |
| Input Attenuation | Selectable manual and automatic input attenuation between 0dB and 31dB in 1dB steps when LNA not active |
| Maximum DC Input | +5V DC |
| Absolute Maximum Input Level | +6dBm with 0dB internal attenuation |
| Absolute Maximum Short-Term Peak Input Power | +20dBm with 3dB internal attenuation |
| Suggested Maximum Input Power | +0dBm with internal attenuation in automatic mode |
| Best Measurement Input Power | Below -25dBm |
| Input Intercept Point (IIP3) | +15dBm with 0dB internal attenuation |
| 1dB Compression Point | -1dBm with 0dB internal attenuation |
| Power Detector Resolution | 0.5dB |
| Linearity vs Frequency | ±2dB below 5.3GHz, ±5dB between 5.3GHz and 6GHz |
| Absolute Power Level Accuracy | ±2dB after power level calibration |
| Built-in Optional LNA | 20dB LNA with Noise Figure of 5dB |
| Lowest Discernible Signal without LNA | -102dBm at 50MHz using a resolution bandwidth of 30kHz |
| Lowest Discernible Signal with LNA | -145dBm at 50MHz using a resolution bandwidth of 200Hz |
| Frequency Accuracy | Equal to the selected resolution bandwidth |
| Phase Noise | -10dBc/Hz at 100kHz offset and -115dBc/Hz at 1MHz offset at 30MHz |
| Spur Free Dynamic Range | 70dB when using a 30kHz resolution bandwidth |
| Resolution Filters | 0.2, 1, 3, 10, 30, 100, 300, 600, and 850 kHz |
| On-Screen Resolution | 51, 101, 145, 290, or 450 measurement points |
| Scanning Speed | Over 1000 points/second using largest resolution filters |
| Automatic Optimization of Scanning Points | Ensures coverage of the whole scan range regardless of the chosen resolution bandwidth |
| Spur Suppression Option | For assessing if certain signals are internally generated or actually present in the input signal |
| Headphone Output | For listening to the demodulated audio (AM only). Stereo connector only, high impedance is louder, short protected |
General Specifications:
- Display: 4-inch IPS LCD
- Battery: Built-in 5000mAh rechargeable battery (approximately 10 hours working time)
- Storage: MicroSD card slot, supports up to 32GB (32GB card included in Kit 2)
- Connectivity: USB Type-C, 3.5mm audio jack
- Product Dimensions: 163.5mm x 92mm x 42mm
- Package Weight: 545g
- Certification: CE
- DIY Supplies: Electrical
8. User Tips
- Data Logging: Utilize the MicroSD card slot to record measurement data, settings, and screenshots for later analysis or documentation.
- PC Integration: Connect the SA5 to your computer via USB for a larger display and easier data management, especially for complex analyses or long-term monitoring.
- Optimizing Battery Life: For extended field use, consider carrying a portable power bank to recharge the SA5 via its USB-C port.
- Signal Generation: Experiment with the signal generator function to test various circuits and antennas, leveraging its sine wave, square wave, and RF test signal capabilities.
- Attenuator vs. LNA: Remember that the input attenuator and LNA are not compatible simultaneously. Choose the appropriate setting based on whether you need to reduce a strong signal or amplify a weak one.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the seller directly. Keep your proof of purchase for any warranty claims.