PORTXVNSA SA5

Contents

PORTXVNSA SA5 Multi-Function Handheld Spectrum Analyzer User Manual

Model: SA5

1. Introduction

The PORTXVNSA SA5 is a compact, multi-functional handheld device designed for both spectrum analysis and signal generation. Featuring a 4-inch IPS LCD and a robust 5000mAh battery, it offers portability and precision for various electrical and RF testing applications. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your SA5 device.

PORTXVNSA SA5 device highlighting its 2-in-1 function as a spectrum analyzer and signal generator.
Figure 1: SA5 device showcasing its dual functionality as a spectrum analyzer and signal generator.
PORTXVNSA SA5 device with a hand interacting with its 4-inch IPS LCD display, emphasizing touch sensitivity.
Figure 2: The SA5's 4-inch IPS LCD display, designed for clear data readability and sensitive touch interaction.

Video 1: An overview of the PORTXVNSA SA5 Multi-Function Handheld Spectrum Analyzer.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and undamaged. The SA5 is available in two kits:

Standard Kit:

  • Main unit (with 5000mAh battery, 4-inch display) x 1
  • USB Type-C data cable x 1
  • 30cm RG405 SMAJB2/SMAJB2 RF connecting cable x 2
  • SMA-SMA barrel connector x 1
  • Antenna with SMA connector x 1
  • Lanyard touch pad x 1
  • Touch pen x 1

Kit 2 (with 32GB MicroSD Card):

  • Main unit (with 5000mAh battery, 4-inch display) x 1
  • USB Type-C data cable x 1
  • 30cm RG405 SMAJB2/SMAJB2 RF cable x 2
  • SMA-SMA barrel connector x 1
  • Antenna with SMA connector x 1
  • Lanyard touch pad x 1
  • Touch pen x 1
  • 32GB MicroSD card (pre-inserted into main unit) x 1
Image showing the PORTXVNSA SA5 device along with its user manual and various accessories included in the package.
Figure 3: Contents of the SA5 package, including the device, manual, cables, antenna, and touch pen.

3. Setup and Initial Use

3.1 Charging the Device

The SA5 comes with a built-in 5000mAh rechargeable battery. For optimal performance, fully charge the device before first use. A full charge provides approximately 10 hours of portable use.

  1. Connect the provided USB Type-C data cable to the Type-C port on the SA5.
  2. Connect the other end of the cable to a compatible USB power adapter (not included) or a computer's USB port.
  3. The device will indicate charging status on the screen.
PORTXVNSA SA5 device connected via USB-C to a laptop, illustrating the charging process and highlighting the 5000mAh battery.
Figure 4: Charging the SA5 via its USB-C port. The device features a 5000mAh battery for extended use.

3.2 MicroSD Card Installation (if applicable)

If your kit did not include a pre-inserted 32GB MicroSD card, you can install one for data storage.

  1. Locate the SD card interface on the side of the SA5 device.
  2. Gently insert a MicroSD card (up to 32GB recommended) into the slot until it clicks into place.
  3. To remove, push the card in slightly until it springs out.

3.3 Powering On/Off

The SA5 features an on/off switch for easy control.

  • To power on, slide the switch to the "ON" position.
  • To power off, slide the switch to the "OFF" position.
Close-up of the PORTXVNSA SA5 device showing the Type-C interface, SD card interface, 3.5mm jack, and the rotary knob with an on/off switch.
Figure 5: Key interfaces and controls of the SA5, including the on/off switch, Type-C port, SD card slot, 3.5mm jack, and rotary knob.

3.4 Connecting Accessories

Depending on your measurement needs, connect the appropriate accessories:

  • Antenna: Screw the provided antenna into the RF input port for general signal reception.
  • RF Cables: Use the 30cm RG405 SMAJB2/SMAJB2 RF connecting cables to connect the SA5 to other RF equipment.
  • SMA-SMA Barrel Connector: Use this connector to join two SMA cables or adapt an SMA connection.

4. Operating Instructions

The SA5 features a 4-inch IPS LCD touch screen and a rotary knob for navigation and control.

4.1 Basic Navigation

  • Touch Screen: Use the touch pen or your finger to interact with on-screen menus and input data.
  • Rotary Knob: Turn the knob to scroll through options or adjust values. Press the knob to confirm selections.

4.2 Spectrum Analyzer Function

The SA5 operates as a spectrum analyzer with the following capabilities:

  • Frequency Range: 0.1-800MHz in normal mode.
  • Ultra Mode: When Ultra mode is enabled, it provides level calibrated signal frequencies up to 5.3GHz and can observe signal frequencies up to 12GHz.
  • Spectrum Display: Displays up to 450 points and shows 4 independently configurable curves.
  • Resolution Bandpass Filter: The resolution bandpass filter ranges from 200Hz to 850kHz, allowing for detailed signal analysis.
  • Optional LNA: Features a built-in 20dB Low Noise Amplifier (LNA) for improved sensitivity.
  • Input Attenuator: The adjustable range of the step attenuator is 0dB to 31dB. Note that this is not compatible with LNA when active.

4.3 Signal Generator Function

When not in spectrum analyzer mode, the SA5 can function as a signal generator:

  • Sine Wave Output: Generates sine waves ranging from 0.1-800MHz.
  • Square Wave Output: Generates square waves up to 4.4GHz.
  • RF Test Signals: Can output RF test signals up to 5.3GHz.

4.4 Calibration

The device includes a built-in calibration signal generator for automatic self-testing and input calibration, ensuring accurate measurements.

PORTXVNSA SA5 device with an antenna connected, displaying various settings and features like resolution bandpass filter, LNA, input attenuator, and calibration.
Figure 6: The SA5's interface showing advanced settings for spectrum analysis, including filter, LNA, attenuator, and calibration options.

4.5 PC Connection

The SA5 can be connected to a PC via USB for enhanced control and data transfer.

  1. Connect the SA5 to your computer using the provided USB Type-C cable.
  2. The device can then function as a PC-controlled spectrum analyzer or signal generator.
  3. Data, settings, and screenshots stored on the MicroSD card can be directly transferred to the computer.
PORTXVNSA SA5 device connected to a desktop computer, demonstrating its PC connectivity for control and data transfer.
Figure 7: Connecting the SA5 to a PC via USB for advanced control and data management.

5. Maintenance

5.1 Cleaning

  • Wipe the device with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents, as they may damage the screen or casing.
  • Keep the ports free of dust and debris.

5.2 Battery Care

  • To prolong battery life, avoid fully discharging the device frequently.
  • Charge the device regularly, even if not in use, to maintain battery health.
  • Store the device in a cool, dry place when not in use for extended periods.

5.3 Storage

  • Store the SA5 in a protective case to prevent physical damage.
  • Ensure the MicroSD card is properly inserted or removed before storage.
  • Keep the device away from extreme temperatures and humidity.

6. Troubleshooting

6.1 Device Not Powering On

  • Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and allow it to charge for at least 30 minutes.
  • Verify the on/off switch is in the "ON" position.

6.2 Display Issues

  • If the screen is unresponsive, try restarting the device.
  • Ensure the screen is clean and free from moisture or debris that might interfere with touch input.

6.3 Inaccurate Measurements

  • Perform a calibration using the built-in calibration signal generator.
  • Check all cable connections for proper seating and integrity.
  • Ensure the correct input attenuator settings are applied for your measurement scenario.
  • Verify that the LNA is not active if the input attenuator is in use, as they are not compatible simultaneously.

6.4 PC Connection Problems

  • Ensure the USB Type-C cable is securely connected to both the SA5 and the PC.
  • Try a different USB port on your computer.
  • Check if necessary drivers are installed on your PC (refer to manufacturer's website for driver downloads if needed).

7. Specifications

The following table details the technical specifications of the PORTXVNSA SA5 Multi-Function Handheld Spectrum Analyzer:

Table detailing the instrument specifications of the SA5, including input frequency range, impedance, attenuation, maximum input levels, resolution filters, and more.
Figure 8: Detailed instrument specifications for the SA5.
SpecificationDetails
Input Frequency Range100kHz to 800MHz in normal mode, up to 6GHz with ULTRA mode enabled
Input Impedance50 ohm when input attenuation set to 10dB or more
Input AttenuationSelectable manual and automatic input attenuation between 0dB and 31dB in 1dB steps when LNA not active
Maximum DC Input+5V DC
Absolute Maximum Input Level+6dBm with 0dB internal attenuation
Absolute Maximum Short-Term Peak Input Power+20dBm with 3dB internal attenuation
Suggested Maximum Input Power+0dBm with internal attenuation in automatic mode
Best Measurement Input PowerBelow -25dBm
Input Intercept Point (IIP3)+15dBm with 0dB internal attenuation
1dB Compression Point-1dBm with 0dB internal attenuation
Power Detector Resolution0.5dB
Linearity vs Frequency±2dB below 5.3GHz, ±5dB between 5.3GHz and 6GHz
Absolute Power Level Accuracy±2dB after power level calibration
Built-in Optional LNA20dB LNA with Noise Figure of 5dB
Lowest Discernible Signal without LNA-102dBm at 50MHz using a resolution bandwidth of 30kHz
Lowest Discernible Signal with LNA-145dBm at 50MHz using a resolution bandwidth of 200Hz
Frequency AccuracyEqual to the selected resolution bandwidth
Phase Noise-10dBc/Hz at 100kHz offset and -115dBc/Hz at 1MHz offset at 30MHz
Spur Free Dynamic Range70dB when using a 30kHz resolution bandwidth
Resolution Filters0.2, 1, 3, 10, 30, 100, 300, 600, and 850 kHz
On-Screen Resolution51, 101, 145, 290, or 450 measurement points
Scanning SpeedOver 1000 points/second using largest resolution filters
Automatic Optimization of Scanning PointsEnsures coverage of the whole scan range regardless of the chosen resolution bandwidth
Spur Suppression OptionFor assessing if certain signals are internally generated or actually present in the input signal
Headphone OutputFor listening to the demodulated audio (AM only). Stereo connector only, high impedance is louder, short protected

General Specifications:

  • Display: 4-inch IPS LCD
  • Battery: Built-in 5000mAh rechargeable battery (approximately 10 hours working time)
  • Storage: MicroSD card slot, supports up to 32GB (32GB card included in Kit 2)
  • Connectivity: USB Type-C, 3.5mm audio jack
  • Product Dimensions: 163.5mm x 92mm x 42mm
  • Package Weight: 545g
  • Certification: CE
  • DIY Supplies: Electrical

8. User Tips

  • Data Logging: Utilize the MicroSD card slot to record measurement data, settings, and screenshots for later analysis or documentation.
  • PC Integration: Connect the SA5 to your computer via USB for a larger display and easier data management, especially for complex analyses or long-term monitoring.
  • Optimizing Battery Life: For extended field use, consider carrying a portable power bank to recharge the SA5 via its USB-C port.
  • Signal Generation: Experiment with the signal generator function to test various circuits and antennas, leveraging its sine wave, square wave, and RF test signal capabilities.
  • Attenuator vs. LNA: Remember that the input attenuator and LNA are not compatible simultaneously. Choose the appropriate setting based on whether you need to reduce a strong signal or amplify a weak one.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the seller directly. Keep your proof of purchase for any warranty claims.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.