ATORCH DT550

Contents

ATORCH DT550 Digital Voltage Current Tester User Manual

Model: DT550 | Brand: ATORCH

1. Introduction

The ATORCH DT550 is a high-precision digital voltage and current tester designed for DC 5.5 equipment. It features a color screen display capable of real-time voltage and current curve analysis, peak value recording, and power-off memory. This versatile instrument supports bidirectional detection and offers a high-definition display with a four-sided rotating screen for enhanced user experience. It is ideal for testing various DC 5.5 devices, including laptops, routers, and computer monitors.

ATORCH DT550 Digital Voltage Current Tester with key features

Figure 1: ATORCH DT550 Digital Voltage Current Tester highlighting Voltage Range (DC4.5-50V), Power Range (0-600W), Current Range (0-6A, short-term peak 12A), Curve Display, Peak Record, Bidirectional Detection, and White/Color Screen Switch.

ATORCH DT550 showing real-time voltage and current curve display

Figure 2: Real-time voltage and current curve display on the DT550, allowing for detailed analysis of power fluctuations.

2. Package Contents

  • 1 x ATORCH DT550 Digital Voltage Current Tester (Matte White or Matte Black)
  • 1 x User Manual
ATORCH DT550 Matte WhiteATORCH DT550 Matte Black

Figure 3: Available colors for the DT550: Matte White and Matte Black.

3. Setup and Connection

The DT550 is designed for easy inline connection to DC 5.5 devices. It features a full copper high-current dual metal interface for stable detection and good contact.

  1. Identify the DC power source (e.g., power adapter, power bank) and the device to be tested (e.g., laptop, router).
  2. Connect the male DC5.5 plug of the DT550 to the DC output of your power source. The DT550's male tuning fork design is compatible with both 2.5mm and 2.1mm DC 5.5 interfaces.
  3. Connect the female DC5.5 port of the DT550 to the DC input of your device.
  4. Ensure all connections are secure before applying power.
DT550 Male tuning fork design and compatibility

Figure 4: The DT550 features a male tuning fork design compatible with 2.5mm and 2.1mm DC 5.5 interfaces, ensuring broad compatibility.

DT550 testing various DC devices like a router, laptop, and computer monitor

Figure 5: Examples of DT550 application, demonstrating its use with a router, laptop, and computer monitor.

4. Operating Instructions

4.1 Key Operations

The DT550 features two main buttons for navigation and control:

  • Function Button:
    • Short Press: Cycles through different display interfaces (e.g., main data, curve display, large character display, zero no-load current).
    • Long Press: Performs specific actions depending on the current interface:
      • On the main data interface: Resets all accumulated data (Wh, mAh, time).
      • On the zero no-load current interface: Resets the no-load current to zero.
      • On the curve display interface: Pauses or resumes the real-time curve display.
  • Rotating Screen Button:
    • Short Press: Rotates the display content 360 degrees in four directions, adapting to various viewing angles.
    • Long Press (on the first or second page interface): Switches between color screen display and black & white text display.
DT550 key operation diagram

Figure 6: Diagram illustrating the Function Button and Rotating Screen Button, along with input/output ports and measurement display area.

4.2 Display Interfaces

The DT550 offers multiple display modes to present measurement data:

  • Main Data Interface: Displays real-time Voltage (V), Current (A), Power (W), Current Direction, accumulated Quantity of Electricity (Wh), accumulated Capacity Value (mAh), CPU Temperature, and elapsed Time. It also shows maximum recorded values for Voltage, Current, and Power.
  • Curve Display Interface: Shows real-time voltage and current curves over time, useful for observing fluctuations during operation or charging.
  • Large Character Display Interface: Presents Voltage, Current, and Power in larger fonts for easier readability.
  • Zero No-load Current Interface: Displays the current when no load is connected, allowing for calibration or checking for parasitic drain.
DT550 multi-functional interface details

Figure 7: Detailed breakdown of the DT550's multi-functional interface, explaining each displayed parameter.

DT550 color screen and black and white screen comparison

Figure 8: Demonstration of switching between color screen and black & white text display using the screen rotation button.

DT550 screen rotation in four directions

Figure 9: The DT550's screen can be rotated 360 degrees for optimal viewing from any angle.

4.3 Video Demonstration

Play video
Watch video online

Video 1: A demonstration of the ATORCH DT550's functions, including interface switching, screen rotation, and measuring charging parameters for electric screwdrivers and power banks, as well as power consumption of a light box.

5. Specifications

The ATORCH DT550 is built with precision and quality materials, including full copper high-current dual metal interfaces for reliable performance.

Internal components of the DT550

Figure 10: View of the internal components of the DT550, showcasing real materials and circuit board design.

ATORCH DT550 Product Parameters
ParameterValue
Product NameDT5.5 electric energy meter
Product ModelDT550
Working VoltageDC4.5-50V
Working Current0-6A (short-term peak value 12A)
Power Consumption<0.5W
Power Display Range0-600W
Sampling Resistance0.001R
Data Retention PeriodTA=55C, 20 years
Energy Range0-9999999Wh
Capacity Range0-9999999mAh
Working Temperature0-45°C / 32-113°F
Product Dimensions58 * 26 * 16 mm
CertificationCE
Power SourceDC
Display TypeAnalog and Digital
Accuracy Class1.0
DT550 product parameters and dimensions

Figure 11: Comprehensive table of DT550 product parameters and physical dimensions.

Back view of DT550 showing model, voltage, current, and certifications

Figure 12: Back view of the DT550, displaying model number, voltage and current ranges, and CE certification.

6. Maintenance

  • Keep the device clean and dry. Avoid exposure to moisture or extreme temperatures.
  • Do not use abrasive cleaners or solvents on the display or casing. Use a soft, dry cloth for cleaning.
  • Store the device in a safe place when not in use to prevent physical damage.
  • The device is designed for long-term data retention (up to 20 years at TA=55C), but regular data backup is recommended for critical measurements.

7. Troubleshooting

  • No Display:
    • Ensure the device is correctly connected between a DC power source and a load. The DT550 draws power from the circuit it is measuring.
    • Verify that the input voltage is within the DC4.5-50V operating range.
  • Incorrect Readings:
    • Check all connections for proper contact.
    • Ensure the device is not overloaded (max 6A continuous, 12A peak).
    • If evaluating capacity values for different voltages, remember that the displayed capacity is at the current voltage. Manual conversion may be needed for other voltages.
    • Perform a data reset by long-pressing the function button on the main interface.
  • Screen Orientation Issue:
    • Short press the rotating screen button to adjust the display orientation.
  • Display Color Issue:
    • Long press the rotating screen button (on the first or second page interface) to switch between color and black & white display.

Important Note on Capacity Values:

The capacity values (Wh, mAh) displayed are calculated based on the current voltage. If you are evaluating the capacity for a device that operates at a different voltage than what is currently being measured, you will need to convert these values yourself for accurate assessment at the target voltage.

8. User Tips

  • The DT550 is highly versatile and can be used with a wide range of DC 5.5 devices, including various laptop brands (e.g., Acer), routers, and other electronics that use compatible DC barrel connectors.
  • Utilize the real-time curve display to monitor charging cycles or power fluctuations in sensitive equipment, helping to diagnose intermittent issues.
  • The power-off memory feature ensures that accumulated data is retained even after the device is disconnected, making it convenient for long-term monitoring projects.

9. Warranty and Support

ATORCH products undergo strict testing to ensure quality. If you encounter any questions or issues regarding the use of your DT550, please contact the seller or ATORCH customer support for assistance. We are committed to actively resolving your concerns.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.