1. Introduction
The TTNergy TECO Hybrid Solar Inverter is a multi-function inverter/charger designed to provide uninterruptible power support with a portable size. It combines the functions of an inverter, solar charger, and battery charger. This device is engineered for higher yields, safety, reliability, and user-friendliness, featuring a comprehensive LCD display for user-configurable and easy-accessible button operation. Users can adjust settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your TTNergy TECO Hybrid Solar Inverter.
2. Safety Information
WARNING: Please read and understand all instructions and warnings in this manual before installing, operating, or servicing this equipment. Failure to follow these instructions may result in electric shock, fire, severe injury, or death.
- Only qualified personnel should perform installation and wiring.
- Ensure all power sources (AC, PV, Battery) are disconnected and verified before performing any installation or maintenance.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Install the inverter in a well-ventilated area, away from flammable materials, direct sunlight, and moisture.
- Ensure proper grounding of the inverter.
- Keep children away from the inverter.
3. Setup
3.1 Physical Installation
The TTNergy TECO Hybrid Solar Inverter is designed for wall mounting. Choose a location that is:
- Well-ventilated to ensure adequate airflow for cooling.
- Protected from direct sunlight, rain, and excessive humidity.
- Away from flammable or explosive materials.
- Capable of supporting the inverter's weight (approximately 8-10 kg depending on the model).
Dimensions: 420mm (D) x 350mm (W) x 110mm (H)


3.2 Wiring Connections
All wiring must comply with local and national electrical codes. Ensure correct polarity for DC connections (PV and Battery) and proper phase/neutral/ground for AC connections.

- Battery Connection: Connect the battery bank to the BATTERY terminals, ensuring correct polarity (+ to + and - to -). The inverter supports 24VDC or 48VDC battery systems depending on the model.
- PV Input Connection: Connect the solar panel array to the PV IN terminals. Observe the specified MPPT voltage range (60-450VDC) and maximum input current for your model.
- AC Input Connection: Connect the utility grid or generator to the AC IN terminals.
- AC Output Connection: Connect your loads to the MAIN OUT and SECOND OUT terminals.
- Communication Port (COMM): Use this port for RS232/RS485, WIFI, GPRS, or Lithium Battery communication.
- Grounding: Ensure the inverter is properly grounded according to local electrical codes.
3.3 Initial Power-Up
- Double-check all wiring connections for tightness and correct polarity.
- Ensure all external circuit breakers are in the OFF position.
- Turn on the battery breaker first.
- Turn on the PV array breaker.
- Turn on the AC input breaker (if connected to grid/generator).
- Turn on the inverter's power switch (located on the side, refer to Figure 2).
- Observe the LCD display for status indicators and any error messages.
- Finally, turn on the AC output breakers to power your loads.
4. Operating Instructions
4.1 LCD Display and Button Operation
The inverter features a comprehensive LCD display and user-friendly buttons for configuration and monitoring. The display shows real-time system status, operational parameters, and error codes. The buttons (typically Menu, Up, Down, Enter) allow navigation through menus and adjustment of settings.
Key configurable settings include:
- Battery charging current.
- AC or solar charger priority.
- Acceptable input voltage range.
- Output source priority (Solar, Utility, Battery).
4.2 Operating Modes
The TTNergy TECO Hybrid Solar Inverter supports various operating modes:
- Hybrid Solar System: Combines solar power, battery power, and utility grid power to optimize energy usage and provide continuous power.
- Off-Grid System: Operates independently from the utility grid, relying on solar power and battery storage.
- On-Grid System: Synchronizes with the utility grid, allowing for self-consumption of solar power and potentially feeding excess power back to the grid.
4.3 Monitoring
The inverter includes communication ports (RS232/RS485/WIFI/GPRS) for remote monitoring. WIFI and GPRS connectivity are available for iOS and Android devices, allowing users to monitor system performance and status via a dedicated application.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Periodic Inspection: Regularly check all electrical connections for tightness and signs of corrosion.
- Cleaning: Keep the inverter's exterior clean and free of dust. Ensure ventilation openings are unobstructed. The inverter features a built-in anti-dust kit for harsh environments.
- Environmental Check: Ensure the installation environment remains within specified temperature and humidity ranges.
- Battery Health: Monitor battery voltage and performance. The smart battery charge design helps optimize battery life.
6. Troubleshooting
If you encounter issues, check the LCD display for error codes or status messages. Here are some common troubleshooting tips:
- No Power/No Output: Verify all circuit breakers (AC, PV, Battery) are ON. Check all wiring connections. Ensure battery voltage is within the operating range.
- Charging Issues: Check PV input voltage and current. Ensure solar panels are clean and unobstructed. Verify battery connections.
- Inverter Not Starting: If the inverter fails to start, try a 'one-key restoration to factory settings' if available and appropriate for your situation.
- Communication Problems: Ensure WIFI/GPRS modules are correctly installed and configured. Check network connectivity.
For complex issues or persistent problems, contact customer support.
7. Specifications
The TTNergy TECO Hybrid Solar Inverter is available in various power ratings. Below are the detailed specifications for the TECO, AX, GAS, and PAL series.
7.1 TECO Hybrid Smart Series Specifications

| Model | TTN-TECO-3.6KW | TTN-TECO-4.2KW | TTN-TECO-6.2KW |
|---|---|---|---|
| Phase | 1-Phase | ||
| Maximum PV Input Power | 6200W | 6200W | 6500W |
| Rated Output Power | 3600W | 4200W | 6200W |
| Maximum Solar Charging Current | 120A | ||
| GRID-TIE OPERATION | |||
| PV Input (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 60VDC/90VDC | ||
| MPPT Voltage Range | 60-450VDC | ||
| Nominal Output Voltage | 220/230/240VAC | ||
| Nominal Output Current | 15.7A | 18.2A | 27.0A |
| Power Factor | >0.99 | ||
| EFFICIENCY | |||
| Maximum Conversion Efficiency (DC/AC) | 98% | ||
| TWO LOAD OUTPUT POWER | |||
| Full Load | 3600W | 4200W | 6200W |
| Maximum Main Load | 3600W | 4200W | 6200W |
| Maximum Second Load (battery mode) | 1200W | 1400W | 2067W |
| Maximum Load Cut Off Voltage | 26VDC | 26VDC | 52VDC |
| Maximum Load Return Voltage | 27VDC | 27VDC | 54VDC |
| OFF-GRID OPERATION | |||
| AC Input | |||
| AC Start-up Voltage / AC Restart Voltage | 120-140VAC/180VAC | ||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Frequency Range | 49-51 ±1HZ or 59-61 ±1HZ | ||
| Maximum AC Input Current | 30A | 30A | 40A |
| PV Input (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| MPPT Voltage Range | 60-450VDC | ||
| Maximum Input Current | 1/18A | 1/22A | |
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Waveform | Pure Sine Wave | ||
| Efficiency (DC to AC) | 94% | ||
| BATTERY & CHARGER | |||
| Nominal DC Voltage | 24VDC | 48VDC | |
| Maximum Solar Charging Current | 120A | 140A | 120A |
| Maximum AC Charging Current | 100A | 100A | 100A |
| Maximum Charging Current | 120A | 140A | 120A |
| HYBRID OPERATION | |||
| PV Input Side (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | ||
| MPPT Voltage Range | 60-450VDC | ||
| Maximum Input Current | 1/18A | 1/22A | |
| GRID OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Voltage Range | 195.5-253VAC | ||
| Nominal Output Current | 15.7A | 18.2A | 27.0A |
| AC INPUT | |||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Maximum AC Input Current | 30A | 30A | 40A |
| Maximum AC Charging Current | 100A | ||
| GENERAL | |||
| PHYSICAL | |||
| Dimension. D x W x H (mm) | 420*350*110 | ||
| Carton Dimension, D X W X H (mm) | 500*415*180 | ||
| Net Weight (kgs) | 8 | 8.5 | 9 |
| Gross Weight (kgs) | 9 | 9.5 | 10 |
| INTERFACE | |||
| Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY | ||
| ENVIRONMENT | |||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Operating Temperature | -10℃ - 50℃ | ||
| STANDARD | |||
| Compliance Safety | CE | ||
7.2 AX Smart Series Specifications

| Model | TTN AX-7.2KW | TTN AX-8.2KW | TTN AX-10.2KW |
|---|---|---|---|
| Phase | 1-Phase | ||
| Maximum PV Input Power | 8200W | 5400W+5400W | 10200W |
| Rated Output Power | 7200W/7200VA | 8200W/8200VA | 10200W/10200VA |
| Maximum Solar Charging Current | 160A | ||
| GRID-TIE OPERATION | |||
| PV Input (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | ||
| MPPT Voltage Range | 90-450VDC | ||
| Nominal Output Voltage | 220/230/240VAC | ||
| Nominal Output Current | 31.3A | 35.6A | 44.3A |
| Power Factor | >0.99 | ||
| EFFICIENCY | |||
| Maximum Conversion Efficiency (DC/AC) | 98% | ||
| TWO LOAD OUTPUT POWER | |||
| Full Load | 7200W | 8200W | 10200W |
| Maximum Main Load | 7200W | 8200W | 10200W |
| Maximum Second Load (battery mode) | 2400W | 2733W | 3400W |
| Maximum Load Cut Off Voltage | 52VDC | 52VDC | 52VDC |
| Maximum Load Return Voltage | 54VDC | 54VDC | 54VDC |
| OFF-GRID OPERATION | |||
| AC Input | |||
| AC Start-up Voltage / AC Restart Voltage | 120-140VAC/180VAC | ||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Frequency Range | 49-51 ±1HZ or 59-61 ±1HZ | ||
| Maximum AC Input Current | 40A | 40A | 50A |
| PV Input (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| MPPT Voltage Range | 90-450VDC | ||
| Maximum Input Current | 1/23A | ||
| BATTERY MODE OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Waveform | Pure Sine Wave | ||
| Efficiency (DC to AC) | 94% | ||
| BATTERY & CHARGER | |||
| Nominal DC Voltage | 48VDC | ||
| Maximum Solar Charging Current | 140A | 160A | 160A |
| Maximum AC Charging Current | 120A | 140A | 140A |
| Maximum Charging Current | 140A | 160A | 160A |
| HYBRID OPERATION | |||
| PV Input Side (DC) | |||
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | ||
| MPPT Voltage Range | 90-450VDC | ||
| Maximum Input Current | 1/23A | ||
| GRID OUTPUT (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Voltage Range | 195.5-253VAC | ||
| Nominal Output Current | 31.3A | 35.6A | 44.3A |
| AC INPUT | |||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Maximum AC Input Current | 40A | 40A | 50A |
| Maximum AC Charging Current | 140A | ||
7.3 GAS Series Specifications

| Model | TTN GAS-1000-12 | TTN GAS-1500-24 |
|---|---|---|
| RATED POWER | 1000W/1000VA | 1500W/1500VA |
| AC Input | ||
| Voltage | 230VAC | |
| Selectable Voltage Range | 170~280VAC (For Personal Computers) 90~280VAC (For Home Appliances) | |
| Frequency Range | 50 Hz/60Hz (Auto sensing) | |
| AC OUTPUT | ||
| AC Voltage Regulation | 230VAC ±5% | |
| Surge Power | 2000VA | 3000VA |
| Efficiency (Peak) PV to INV | 98% | |
| Efficiency (Peak) Battery to INV | 94% | |
| Transfer Time | 10 ms | |
| BATTERY | ||
| Battery Voltage | 12VDC | 24VDC |
| Floating Charge Voltage | 13.5VDC | 27VDC |
| Overcharge Protection | 16VDC | 32VDC |
| SOLAR CHARGER & AC CHARGER | ||
| Solar Charger Type | MPPT | |
| Maximum PV Array Power | 600W | 1200W |
| MPPT Range @ Operating Voltage | 20~150VDC | |
| Maximum PV Array Open Circuit Voltage Solar | 150VDC | |
| Maximum Solar Charge Current | 40A | |
| Maximum AC Charge Current | 40A | |
| Maximum Charging Current (Solar+AC) | 80A | |
| PHYSICAL | ||
| Dimension, D*W*H (mm) | 290*240*91 | |
| Carton Dimension, D X W X H (mm) | 340*295*145 | |
| Net Weight (kgs) | 3 | 3.5 |
| Gross Weight (kgs) | 3.5 | 4 |
| ENVIRONMENT | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Operating Temperature | -10℃ - 50℃ | |
| STANDARD | ||
| Compliance Safety | CE | |
7.4 PAL Series Specifications

| Model | TTN PAL-2000-12 | TTN PAL-3200-24 |
|---|---|---|
| RATED POWER | 2000VA/1600W | 3200VA/3000W |
| AC Input | ||
| Voltage | 230VAC | |
| Selectable Voltage Range | 170~280VAC (For Personal Computers) 90~280VAC (For Home Appliances) | |
| Frequency Range | 50 Hz/60Hz (Auto sensing) | |
| AC OUTPUT | ||
| AC Voltage Regulation | 230VAC ±5% | |
| Surge Power | 4000VA | 6400VA |
| Efficiency (Peak) PV to INV | 98% | |
| Efficiency (Peak) Battery to INV | 94% | |
| Transfer Time | 10 ms (For Personal Computers); 20 ms (For Home Appliances) | |
| BATTERY | ||
| Battery Voltage | 12VDC | 24VDC |
| Floating Charge Voltage | 13.5VDC | 27VDC |
| Overcharge Protection | 16VDC | 33VDC |
| SOLAR CHARGER & AC CHARGER | ||
| Solar Charger Type | MPPT | |
| Maximum PV Array Power | 2000W | 3000W |
| MPPT Range @ Operating Voltage | 30~400VDC | |
| Maximum PV Array Open Circuit Voltage Solar | 400VDC | |
| Maximum Solar Charge Current | 80A | |
| Maximum AC Charge Current | 60A | |
| Maximum Charging Current (Solar+AC) | 130A | |
| PHYSICAL | ||
| Dimension, D*W*H (mm) | 357*273*95 | |
| Carton Dimension, D X W X H (mm) | 440*340*170 | |
| Net Weight (kgs) | 5 | 5.6 |
| Gross Weight (kgs) | 6 | 6.3 |
| INTERFACE | ||
| Communication Interface | RS232/GPRS/WIFI | |
| ENVIRONMENT | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Operating Temperature | -10℃ - 50℃ | |
| STANDARD | ||
| Compliance Safety | CE | |
8. User Tips
- Smart Battery Management: The inverter features a smart battery charge design to optimize battery life.
- Harsh Environment Ready: Equipped with a built-in anti-dust kit, making it suitable for use in challenging environments.
- Flexible Operation: The inverter can run without a battery, offering flexibility in system design.
- Easy Reset: A 'one-key restoration to factory settings' function simplifies troubleshooting and reconfiguration.
- Lithium Battery Compatibility: Designed for communication with lithium batteries, ensuring efficient and safe operation with modern battery technologies.
- Remote Monitoring: Utilize the WIFI/GPRS connectivity with iOS and Android apps for convenient remote monitoring of your solar system.
- Dual Output: Benefit from dual AC outputs for managing different load priorities.
- Pure Sine Wave Output: Provides clean and stable power, suitable for sensitive electronics.
9. Warranty and Support
Your TTNergy TECO Hybrid Solar Inverter is designed and manufactured to high-quality standards. For warranty information, please refer to the terms provided at the time of purchase or contact your seller. The product is CE compliant, indicating it meets European safety, health, and environmental protection requirements.
For technical support, troubleshooting assistance, or any inquiries, please contact your authorized TTNergy dealer or the seller directly. Ensure you have your product model and serial number ready for faster service.