1. Introduction
The TTNergy AX Series is a multi-function inverter/charger designed to provide uninterruptible power support for solar hybrid systems. It integrates the functions of an inverter, solar charger, and battery charger into a compact unit. The comprehensive LCD display allows users to configure various settings, including battery charging current, AC/solar charger priority, and acceptable input voltage, to suit different applications.
2. Key Features
- Pure sine wave output for reliable power supply.
- High output power factor of 1.0.
- Integrated Wi-Fi and Bluetooth connectivity for iOS and Android monitoring.
- Capable of running without a battery.
- One-key restoration to factory settings for easy reset.
- Automatic activation for lithium batteries.
- Built-in MPPT solar charger: 140A for 7.2KW model, 160A for 8.2KW and 10.2KW models.
- Wide PV input voltage range: 90-500VDC.
- Equipped with an anti-dust kit for enhanced durability in harsh environments.
- Smart battery charge design to optimize battery life.
- Features dual output and dual PV input.
- User-friendly touch button interface.
- Supports both On-Grid and Off-Grid work modes.
- Communication capabilities with lithium batteries.

Figure 1: Overview of TTNergy Hybrid AX Smart Inverter features and specifications.
3. Specifications
| Parameter | TTN AX-7.2KW | TTN AX-8.2KW | TTN AX-10.2KW |
|---|---|---|---|
| Phase | 1-Phase | ||
| Maximum PV Input Power | 8200W | 8200W | 5400W+5400W |
| Rated Output Power | 7200W/7200VA | 8200W/8200VA | 10200W/10200VA |
| Maximum Solar Charging Current | 140A | 160A | 160A |
| Grid-Tie Operation PV Input (DC) | |||
| Nominal DC Voltage/Max DC Voltage | 360/500VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | ||
| MPPT Voltage Range | 90-450VDC | ||
| Maximum Input Current | 1/23A | 1/23A | 2/18A |
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Voltage Range | 195.5-253VAC | ||
| Nominal Output Current | 31.3A | 35.6A | 44.3A |
| Power Factor | >0.99 | ||
| Efficiency | |||
| Maximum Conversion Efficiency (DC/AC) | 98% | ||
| Two Load Output Power | |||
| Full Load | 7200W | 8200W | 10200W |
| Maximum Main Load | 7200W | 8200W | 10200W |
| Maximum Second Load (Battery Mode) | 2400W | 2733W | 3400W |
| Maximum Load Cut Off Voltage | 52VDC | ||
| Maximum Load Return Voltage | 54VDC | ||
| Off-Grid Operation AC Input | |||
| AC Start-up Voltage / AC Restart Voltage | 120-140VAC/180VAC | ||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Frequency Range | 49-51 ±1HZ | ||
| Maximum AC Input Current | 40A | 40A | 50A |
| Off-Grid Operation PV Input (DC) | |||
| Nominal DC Voltage/Max DC Voltage | 360/500VDC | ||
| MPPT Voltage Range | 90-450VDC | ||
| Maximum Input Current | 1/23A | 2/18A | 2/18A |
| Battery Mode Output (AC) | |||
| Nominal Output Voltage | 220/230/240VAC | ||
| Output Waveform | Pure sine wave | ||
| Efficiency (DC to AC) | 94% | ||
| Battery & Charger | |||
| Nominal DC Voltage | 48VDC | ||
| Maximum Solar Charging Current | 140A | 160A | 160A |
| Maximum AC Charging Current | 120A | 140A | 140A |
| Maximum Charging Current | 140A | 160A | 160A |
| Physical | |||
| Dimensions (D x W x H) | 500x390x130mm | 588x463x205mm | 618x463x205mm |
| Net Weight | 13.5KG | 14.5KG | 15KG |
| Gross Weight | 14.9KG | 16.1KG | 16.2KG |
| Interface | |||
| Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY | ||
| Environment | |||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Operating Temperature | -10°C to 50°C | ||
| Standard | |||
| Compliance | CE | ||
4. Setup and Installation
Installation of the TTNergy AX Series inverter should be performed by qualified personnel to ensure safety and optimal performance. Refer to the detailed wiring diagrams and instructions provided in the full product manual for specific connection procedures.
4.1 Physical Overview
Video 1: Product overview of the TTNergy solar inverter, highlighting its features and connection ports.
The inverter features a robust design with clearly labeled connection points. Key interfaces include:
- AC In: For connecting to the utility grid.
- Main Out & Second Out: For connecting to primary and secondary loads.
- PV Cover: Protects the solar input terminals.
- Switch: Main power switch for the unit.
- RS232 & RS485: Communication ports.
- WIFI & BMS: Modules for wireless communication and Battery Management System integration.
- Battery (+/-): Terminals for battery connection.

Figure 2: Rear view of the TTNergy solar inverter, detailing the various connection ports.
4.2 Wiring Connections
Ensure all connections are secure and correctly polarized. Pay close attention to the PV input voltage range (90-500VDC) and battery connections. The inverter supports automatic activation for lithium batteries.

Figure 3: Example of an installed TTNergy inverter system with visible wiring connections.

Figure 4: Another view of an inverter and battery system, showing more complex wiring for a complete setup.
5. Operating Instructions
The TTNergy AX Series inverter features a user-friendly LCD display and touch buttons for easy operation and configuration.
5.1 Initial Power-Up
After all connections are securely made, turn on the main switch. The LCD display will illuminate, guiding you through the initial setup or displaying operational status.
5.2 User Configuration
Use the navigation buttons on the display to access and adjust settings such as:
- Battery Charging Current: Adjust according to your battery specifications.
- AC/Solar Charger Priority: Select whether the inverter prioritizes AC input or solar power for charging.
- Input Voltage Range: Set the acceptable input voltage range based on your specific application (e.g., appliance mode, UPS mode).
- On/Off Grid Work Mode: Configure the inverter to operate in grid-tied, off-grid, or hybrid modes.
For detailed menu navigation and parameter adjustments, refer to the comprehensive user manual included with your product.
5.3 Remote Monitoring
Utilize the built-in Wi-Fi and Bluetooth capabilities to monitor your inverter's performance and adjust settings via a dedicated application on your iOS or Android device. Connect the inverter to your local network using the Wi-Fi module.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your TTNergy AX Series inverter.
- Cleaning: Keep the inverter's exterior clean and free from dust. The built-in anti-dust kit helps protect internal components, but external cleaning is still recommended.
- Ventilation: Ensure that the ventilation openings are not obstructed to prevent overheating.
- Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
- Battery Health: The smart battery charge design helps optimize battery life. However, regular monitoring of battery health and performance is advisable, especially for lead-acid batteries.
- Firmware Updates: Check the manufacturer's website or the mobile application for any available firmware updates to ensure optimal performance and access to new features.
7. Troubleshooting
This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact customer support.
7.1 Common Issues and Solutions
- Inverter Not Powering On:
- Check the main power switch on the side of the inverter.
- Verify battery connections and voltage.
- Ensure AC input is present if operating in hybrid or grid-tied mode. - No Output Power:
- Check output circuit breakers.
- Verify load connections.
- Check for any error codes on the LCD display. - Low Solar Charging:
- Ensure PV panels are clean and not shaded.
- Check PV array connections and voltage within the MPPT range (90-450VDC).
- Inspect solar charging current settings. - Communication Issues (Wi-Fi/Bluetooth):
- Ensure the Wi-Fi/Bluetooth module is correctly installed and powered.
- Check network connectivity and router settings.
- Restart the inverter and your mobile device.
If the issue persists or an unfamiliar error code appears, record the error message and contact technical support.
8. User Tips
- Battery-Less Operation: The inverter can operate without a battery, which can be useful for direct solar-to-load applications or as a grid-tied inverter. Ensure proper configuration for this mode.
- Lithium Battery Compatibility: The automatic activation feature for lithium batteries simplifies setup and ensures proper charging protocols. Always verify battery compatibility with the inverter's specifications.
- Remote Monitoring: Regularly use the mobile app to monitor system performance, energy production, and battery status. This helps in proactive maintenance and optimization.
- Factory Reset: In case of complex configuration issues or after major system changes, the one-key factory reset can be a quick way to revert to default settings, allowing for a fresh configuration.
9. Warranty and Support
For warranty information, please refer to the warranty card included with your product or contact your point of purchase. Technical support can be reached through the seller or manufacturer's official channels. Please have your model number and purchase details ready when contacting support.