1. Introduction
The TTNergy Hybrid Solar Inverter is a multi-function inverter/charger designed to provide uninterruptible power support for solar energy systems. It combines the functionalities of a power inverter, a solar charger, and a battery charger into a compact and portable unit. This inverter is engineered for high efficiency and reliability, offering a user-friendly interface with configurable settings for various applications.
Key benefits include higher energy yields, safe and reliable operation, smart features, and an intuitive user experience.
2. Features
- Pure sine wave solar inverter for both on-grid and off-grid applications.
- Output power factor of 1.0 for efficient energy delivery.
- Integrated Wi-Fi and Bluetooth connectivity for monitoring and control via iOS and Android devices.
- Capable of running without a battery, providing flexibility in system design.
- One-key restoration to factory settings for easy configuration reset.
- Built-in lithium battery automatic activation feature.
- High PV input voltage range (90-500VDC) for broad solar panel compatibility.
- Built-in anti-dust kit designed for enhanced durability in harsh environments.
- Smart battery charge design to optimize battery life and performance.
- Dual PV input for increased solar array flexibility.
- Dual output for managing different load priorities.
- Intuitive touch button interface for user-friendly operation.
- Supports On/Off Grid Work Mode.
- Communication capabilities with lithium batteries for optimized performance.
- High-efficiency 160A MPPT solar charger (for 8.2KW and 10.2KW models) and 140A (for 7.2KW model).

3. Specifications
The following table details the specifications for the TTNergy AX series hybrid solar inverters:
| Category | Parameter | TTN AX-7.2KW | TTN AX-8.2KW | TTN AX-10.2KW |
|---|---|---|---|---|
| General | Phase | 1-Phase | ||
| Maximum PV Input Power | 8200W | 8200W | 5400W+5400W | |
| Rated Output Power | 7200W/7200VA | 8200W/8200VA | 10200W/10200VA | |
| Maximum Solar Charging Current | 140A | 160A | 160A | |
| Grid-Tie Operation (PV Input DC) | Nominal DC Voltage/Max DC Voltage | 360/500VDC | ||
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | |||
| MPPT Voltage Range | 90-450VDC | |||
| Maximum Input Current | 1/23A | 1/23A, 2/18A | 1/23A, 2/18A | |
| Nominal Output Voltage | 220V/230V/240VAC | |||
| Output Voltage Range | 195.5-253VAC | |||
| Efficiency | Nominal Output Current | 31.3A | 35.6A | 44.3A |
| Maximum Conversion Efficiency (DC/AC) | 98% | |||
| Two Load Output Power | Full Load | 7200W | 8200W | 10200W |
| Maximum Main Load | 7200W | 8200W | 10200W | |
| Maximum Second Load (Battery Mode) | 2400W | 2733W | 3400W | |
| Maximum Load Cut Off Voltage | 52VDC | |||
| Maximum Load Return Voltage | 54VDC | |||
| Off-Grid Operation (AC Input) | AC Start-up Voltage / Auto Restart Voltage | 120-140VAC/180VAC | ||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |||
| Frequency Range | 49-51 ± 1Hz or 59-61 ± 1Hz | |||
| Maximum AC Input Current | 40A | 40A | 50A | |
| Off-Grid Operation (PV Input DC) | Nominal DC Voltage/Max DC Voltage | 360/500VDC | ||
| MPPT Voltage Range | 90-450VDC | |||
| Maximum Input Current | 1/23A | 1/23A, 2/18A | 1/23A, 2/18A | |
| Battery Mode Output (AC) | Nominal Output Voltage | 220V/230V/240VAC | ||
| Output Waveform | Pure Sine Wave | |||
| Efficiency (DC to AC) | 94% | |||
| Battery & Charger | Nominal DC Voltage | 48VDC | ||
| Maximum Solar Charging Current | 140A | 160A | 160A | |
| Maximum AC Charging Current | 120A | 140A | 140A | |
| Maximum Charging Current | 140A | 160A | 160A | |
*Note: Specifications are subject to change without prior notice. Please refer to the product label for the most accurate information.
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your TTNergy Hybrid Solar Inverter. It is highly recommended that installation be performed by a qualified electrician or solar professional.
4.1 Safety Precautions
- Ensure all power sources (AC utility, solar panels, batteries) are disconnected before installation or maintenance.
- Do not connect the battery after the utility is turned on.
- Verify correct polarity for all DC connections (PV and Battery).
- Ensure proper grounding of the inverter.
- Install the inverter in a well-ventilated area, away from flammable materials and direct sunlight.
- Refer to local electrical codes and regulations for installation requirements.
4.2 Physical Installation
The inverter is designed for wall mounting. Choose a sturdy vertical surface capable of supporting the inverter's weight (approximately 17KG). Ensure adequate clearance around the unit for proper ventilation.



4.3 Electrical Connections
The inverter features clearly labeled terminals for AC input, main AC output, second AC output, PV input, and battery connections. It also includes communication ports for Wi-Fi, RS232, RS485, and BMS.

- PV Input: Connect solar panel strings to the designated PV input terminals. Ensure the PV input voltage and current are within the inverter's specified range.
- Battery Connection: Connect the battery bank to the BATTERY terminals, observing correct polarity (+ and -). The inverter supports lithium battery automatic activation.
- AC Input: Connect the AC utility grid to the AC IN terminals.
- AC Output: Connect your primary loads to the MAIN OUT terminals and secondary loads (if applicable) to the SECOND OUT terminals.
- Communication: Utilize the RS232, RS485, WiFi, and BMS ports for monitoring and advanced system integration.
For detailed wiring diagrams and step-by-step instructions, please refer to the comprehensive user manual included with your product. An example of the manual cover is shown below:

4.4 Installation Examples



5. Operating Instructions
Once installed and all connections are secure, you can begin operating your TTNergy Hybrid Solar Inverter.
5.1 Initial Startup
- Ensure all external circuit breakers are in the OFF position.
- Connect the battery bank to the inverter. The inverter features automatic lithium battery activation.
- Connect the solar panels to the PV input.
- Connect the AC utility grid to the AC input.
- Connect your loads to the AC output terminals.
- Turn on the battery breaker, then the PV breaker, and finally the AC input breaker.
- Switch on the inverter's power switch (located on the side, refer to Figure 4.2).
- The LCD display will illuminate, and the inverter will begin its startup sequence.
5.2 LCD Display and Button Operation
The comprehensive LCD display provides real-time system status, operational parameters, and error codes. The user-friendly buttons allow for navigation through menus and configuration of settings such as:
- Battery charging current.
- AC/solar charger priority.
- Acceptable input voltage range.
- On/Off Grid Work Mode selection.
Refer to the detailed user manual for specific menu navigation and parameter adjustment instructions.
5.3 Video Overview
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. The TTNergy inverter includes a built-in anti-dust kit, reducing the frequency of internal cleaning in dusty environments.
6.1 Routine Checks
- Visual Inspection: Periodically check the inverter for any signs of damage, loose connections, or corrosion.
- Ventilation: Ensure that the ventilation openings are clear of dust and debris to prevent overheating.
- Connections: Verify that all electrical connections (PV, battery, AC input/output) are tight and secure.
- Display Monitoring: Regularly check the LCD display for any warning messages or error codes.
- Environment: Maintain a clean and dry environment around the inverter.
6.2 Cleaning
Before cleaning, ensure the inverter is completely powered off and disconnected from all power sources. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or solvents.
7. Troubleshooting
If you encounter issues with your inverter, perform the following basic troubleshooting steps:
- No Power/Display Off:
- Check if the main power switch is ON.
- Verify all AC and DC input breakers are ON.
- Ensure battery connections are secure and the battery voltage is within the operating range.
- No Output Power:
- Check AC output breakers.
- Verify that the inverter is not in an error state (check LCD display for error codes).
- Ensure input power (PV or AC utility) is present and stable.
- Error Codes on Display:
- Note down the specific error code displayed.
- Refer to the detailed user manual for a list of error codes and their corresponding troubleshooting steps.
- Poor Performance:
- Check solar panel connections and ensure they are clean and free from shading.
- Verify battery health and charge level.
- Ensure proper ventilation to prevent thermal derating.
If the problem persists after performing these steps, please contact customer support for further assistance.
8. User Tips
- Optimal Placement: Install the inverter in a cool, dry, and well-ventilated location to maximize its lifespan and efficiency. Avoid direct sunlight exposure.
- Regular Monitoring: Utilize the Wi-Fi/Bluetooth connectivity to regularly monitor your system's performance. This helps in early detection of potential issues and optimization of energy production.
- Battery Management: For systems with batteries, ensure proper battery maintenance and settings are configured to prolong battery life, especially with lithium batteries that benefit from smart charging designs.
- Firmware Updates: Check with the manufacturer or seller for any available firmware updates to ensure your inverter operates with the latest features and improvements.
9. Warranty and Support
For information regarding the product warranty, please refer to the warranty card included with your purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.
For technical support, troubleshooting assistance beyond the scope of this manual, or spare parts, please contact the seller or authorized service center. Provide your product model and serial number when seeking support.