Hantek TO1252D & TO1254D

Contents

Hantek TO1000 Series Digital Oscilloscope User Manual

Models: TO1252D (2-Channel) & TO1254D (4-Channel)

Your testing solution provider.

1. Introduction

The Hantek TO1000 Series Digital Oscilloscope is a versatile, multi-functional handheld device designed for electrical testing and waveform analysis. It integrates a digital storage oscilloscope, arbitrary function signal generator, high-precision multimeter, data recorder, FFT spectrum analyzer, and frequency meter into a single, portable unit. Featuring a multi-touch large screen and an intuitive English interface, it is suitable for both beginners and experienced professionals.

Video 1.1: Hantek TO1000 Series Product Overview

2. Product Overview and Features

The TO1000 series offers a super thin and light design, making it easy to carry. Its unique hangable design allows for hands-free operation, and the anti-shock corners ensure durability. The device features a multi-touch large screen with a resolution of up to 800*480 pixels, providing a friendly and easy-to-use UI for a good interaction experience.

  • Multi-touch Large Screen: Resolution up to 800*480 pixels for intuitive control.
  • Multi-functionality: Combines oscilloscope, multimeter, signal generator, and spectrum analyzer.
  • Portable Design: Super thin, lightweight, and easy to carry.
  • Durable Build: Anti-falling and anti-seismic design with robust corners.
  • Suspension Foot: Unique design for hands-free use, allowing placement at any time.
  • English Interface: Simple and intuitive UI adapted for global usage habits, easy for beginners.
Hantek TO1000 Series Oscilloscope with labeled ports and channels

Figure 2.1: Hantek TO1000 Series Oscilloscope with labeled ports and channels.

Hantek TO1000 Series Oscilloscope demonstrating suspension foot design

Figure 2.2: Suspension foot design for hands-free operation.

3. Setup and Accessories

Before using your Hantek TO1000 series oscilloscope, please ensure all accessories are present and connect the device as described below.

3.1. Package Contents

TO1252D Accessories:

  • Oscilloscope TO1252D x 1
  • X1/X10 Probe x 1
  • Crocodile Clip Testing Line x 2
  • USB Computer Communication Cable x 1
  • Power Plug x 1
  • Instrument Package x 1
TO1252D package contents

Figure 3.1: TO1252D Package Contents.

TO1254D Accessories:

  • Oscilloscope TO1254D x 1
  • X1/X10 Probe x 2
  • Crocodile Clip Testing Line x 3
  • USB Computer Communication Cable x 1
  • Power Plug x 1
  • Instrument Package x 1
TO1254D package contents

Figure 3.2: TO1254D Package Contents.

3.2. Connecting Power and Peripherals

The device supports fast charging via its Type-C interface. Use the provided 18W adapter and Type-C charging cable. The Type-C interface is compatible with mobile phones, allowing shared charging equipment.

  • Power Input: Connect the 18W Type-C charger to the Type-C port on the side of the device.
  • USB Connection: Use the USB connector for computer communication or connecting a U-disk for data storage.
  • Multimeter Jacks: V/Ω/C/Diode Jack, COM Jack, mA Jack, A Jack are located on the side for multimeter functions.
  • Oscilloscope Channels: CH1, CH2 (for TO1252D) and CH1, CH2, CH3, CH4 (for TO1254D) are located on the top for signal input. The AFG (Arbitrary Function Generator) channel is also on the top.
Image showing US and EU plug types

Figure 3.3: Available Power Plug Types (US/EU).

4. Basic Operation

The Hantek TO1000 series features a full touch screen with an intuitive English interface, making operation straightforward.

4.1. User Interface Navigation

The main screen displays icons for various functions:

  • OSC: Oscilloscope function.
  • DMM: Digital Multimeter function.
  • AFG: Arbitrary Function Generator function.
  • File Browser: Access saved data and settings.
  • Settings: Configure device parameters.
  • Pictures: View saved screenshots.
Screenshot of the Hantek oscilloscope's main English interface

Figure 4.1: Main English Interface.

4.2. Oscilloscope Function (OSC)

The oscilloscope function allows for detailed waveform analysis. The TO1254D model offers four channels for advanced measurements.

  • Trigger Types: Supports 7 trigger types including Single, Automatic, Edge, Pulse, Video, Slope, and Timeout, making it easier to capture instantaneous and abnormal signals.
  • Roll Mode: Waveforms roll from right to left, with a horizontal range of 100ms to 100s. This mode is generally used for observing waveforms below 5Hz, providing real-time display without dead zones or data loss. Note that in roll mode, there is no trigger concept, and low probability signals cannot be automatically identified.
  • Mathematical Operations: Perform operations like addition (+), subtraction (-), multiplication (*), and division (/) between Source A and Source B.
  • FFT Spectrum Analysis: The Fast Fourier Transform (FFT) converts time-domain signals into the frequency domain, allowing analysis of the signal's frequency components.
  • X-Y Mode: Used for Lissajous measurements to determine the phase difference between two sine-wave signals of the same frequency.
  • Data Storage: Supports 8G-U disk for saving reference waveforms, CSV waveforms, waveform pictures, settings, and one-click screensaver to U disk.
Screenshot of oscilloscope trigger settings

Figure 4.2: Seven Trigger Types Interface.

Screenshot of oscilloscope in roll mode

Figure 4.3: Roll Mode Display.

Screenshot of oscilloscope mathematical operations and FFT spectrum

Figure 4.4: Mathematical Operations and FFT Spectrum.

Screenshot of oscilloscope in X-Y mode

Figure 4.5: X-Y Mode Display.

Screenshot of oscilloscope data storage function

Figure 4.6: Data Storage Interface.

4.3. Digital Multimeter Function (DMM)

The DMM function provides comprehensive measurement capabilities:

  • Measurements: AC and DC voltage, current, resistance, capacitance, diode, and on-off measurement.
  • Data Recording: Can monitor and record voltage, current, resistance, and other data changes over time, generating trend charts for export.
Screenshot of multimeter function display

Figure 4.7: Multimeter Function Display.

4.4. Arbitrary Function Generator (AFG)

The D series models include an optional signal generator function, allowing the oscilloscope and signal generator to be used simultaneously.

  • Output Frequency: Up to 25MHz.
  • Resolution: 12-bit high resolution.
  • Sampling Rate: 200MS/s.
  • Waveforms: Built-in variety of arbitrary waves, supports AM/FM modulation, and offers switchable high resistance and low resistance output.
Screenshot of arbitrary function generator interface

Figure 4.8: Arbitrary Function Generator Interface.

5. Specifications

Below are the detailed specifications for the Hantek TO1000 series oscilloscopes.

5.1. General Specifications

Attribute Value
Brand NameHantek
Model NumberTO1252D & TO1254D
DIY SuppliesElectrical
CertificationCE
OriginMainland China
Display Size7 Inches & Above
Display Resolution800*480 Pixels
Battery IncludedYes
IS Battery DemountableNo
Charger Supports Type-C18W
High-concerned chemicalNone

5.2. Model Comparison

Models Channel Bandwidth Sample Rate Storage depth Signal generator Multimeter
TO1252D 2 250MHz 1GSa/S 8M ✓ ✓
TO1254D 4 250MHz 1GSa/S 8M ✓ ✓
Battery parameter Four batteries: 3.7V 2600mAh*4, Four-section parallel
Battery life Use for about 7-8 hours, Plug-in power bank

Figure 5.1: Model Comparison Table.

5.3. Oscilloscope Parameters

Oscilloscope parameter table part 1

Figure 5.2: Oscilloscope Parameters (Part 1).

Oscilloscope parameter table part 2

Figure 5.3: Oscilloscope Parameters (Part 2).

Video Trigger Parameters table

Figure 5.4: Video Trigger Parameters.

5.4. Multimeter Parameters

Multimeter parameter table part 1

Figure 5.5: Multimeter Parameters (Part 1).

Multimeter parameter table part 2

Figure 5.6: Multimeter Parameters (Part 2).

5.5. Arbitrary Wave Generator Parameters

Arbitrary wave generator parameter table

Figure 5.7: Arbitrary Wave Generator Parameters.

6. Maintenance and Care

To ensure the longevity and optimal performance of your Hantek TO1000 series oscilloscope, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Avoid abrasive cleaners or solvents that could damage the screen or casing.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Use the provided instrument package for protection during transport and storage.
  • Battery Care: The device has a built-in 10000mAh detachable lithium battery. For optimal battery life, avoid fully discharging the battery frequently and store the device with a partial charge if not used for extended periods.
  • Physical Protection: The device features anti-falling and anti-seismic design. While robust, avoid unnecessary drops or impacts to prevent damage to internal components or the touch screen.
Image highlighting anti-falling and anti-seismic features

Figure 6.1: Anti-falling and Anti-seismic Design.

Image showing battery and charging details

Figure 6.2: High Power and Long Endurance Battery.

7. Troubleshooting

If you encounter issues with your Hantek TO1000 series oscilloscope, consider the following common troubleshooting steps:

  • Device Not Powering On: Ensure the battery is charged. Connect the device to the 18W Type-C charger and allow it to charge for some time before attempting to power on again.
  • No Signal Displayed on Oscilloscope:
    • Check all probe connections to the device and the circuit under test.
    • Verify the input coupling (DC, AC, or GND) and vertical scale settings.
    • Adjust the trigger settings (source, mode, level) to ensure proper waveform capture.
    • Ensure the correct channel is selected and enabled.
  • Multimeter Readings are Incorrect:
    • Confirm the correct jacks (V/Ω/C/Diode, mA, A, COM) are used for the desired measurement.
    • Check the integrity of the multimeter pens and crocodile clips.
    • Ensure the correct measurement function is selected on the device.
  • Signal Generator Not Outputting:
    • Verify the AFG function is selected and configured with desired waveform, frequency, and amplitude.
    • Check the connection from the AFG output to the circuit.
  • Touch Screen Unresponsive: Try restarting the device. If the issue persists, ensure the screen is clean and free from debris.

For more detailed troubleshooting or persistent issues, please refer to the official Hantek website or contact customer support.

8. User Tips

Here are some tips to enhance your experience with the Hantek TO1000 series oscilloscope:

  • Explore Video Tutorials: The official Hantek website (www.hantek.com) provides video learning for up to 48 products, including electronic English instruction manuals and computer software. These resources can be invaluable for mastering advanced features.
  • Utilize Computer Software: The device can communicate with a computer via USB. The computer software allows for easy operation and editing of arbitrary waves, especially useful for D series models.
  • Regular Data Backup: Regularly save your waveforms, settings, and other data to a USB flash drive using the data storage function to prevent loss.
  • Familiarize with Multifunctionality: Take time to explore all integrated functions (oscilloscope, multimeter, signal generator, spectrum analyzer) to leverage the full capabilities of your device.
Screenshot of Hantek website showing video learning resources

Figure 8.1: Data Video Learning Resources on Hantek Website.

Screenshot of Hantek computer software interface

Figure 8.2: Computer Software Interface.

9. Warranty and Support

The Hantek TO1000 series oscilloscope is manufactured with high standards and holds CE and EMC certifications, ensuring compliance with international quality and safety requirements.

CE and EMC certification documents

Figure 9.1: CE and EMC Certification.

For product support, technical assistance, or warranty inquiries, please visit the official Hantek website at www.hantek.com. The website provides comprehensive resources, including video tutorials and detailed instruction manuals.

Please note that this manual focuses on product usage and specifications. For information regarding returns or specific warranty terms, please refer to your purchase documentation or contact the seller directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.