1. Introduction and Overview
The NJTY T-58D is a high-precision digital multimeter designed for both home and professional use. It features 60000 counts, True RMS measurement, smart anti-burn protection, and automatic ranging. This universal meter can measure AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, and includes diode, continuity, and non-contact voltage (NCV) testing functions. Its large LCD display with backlight ensures easy readability in various conditions.


2. Safety Information
When using this meter, the user must comply with all standard safety regulations to prevent electric shocks and misuse of the instrument. Always ensure the test leads are intact before use.
2.1 Safety Instructions
- Protection against electric shocks: Always be aware of live circuits.
- Prevent misuse: Follow the instrument's safety procedures.
- Use only the provided test leads and ensure they are in good condition.
2.2 Safety Precautions
- Avoid using the meter near devices with large electromagnetic disturbances, as this may cause unstable readings or errors.
- Do not use the meter if its appearance or the test leads are broken.
- Incorrect use may compromise the meter's safety functions.
- Exercise caution when working around bare conductors or busbars.
- Do not use this instrument in environments with explosive gas, vapor, or dust.
- Always select the correct input function and range for the measurement.
- Do not exceed the specified input value limits for each range to prevent damage.
- Do not touch unused input terminals when the instrument is connected to a circuit under test.
- Be cautious of electric shock when measuring voltages exceeding 60V DC or 36V AC.
- Ensure test leads are disconnected from the circuit under test before changing ranges.
- For DC voltage measurements, always confirm the presence of AC voltage first (if applicable) to avoid electric shock from incorrect readings, then select an appropriate DC voltage range.
- Before resistance, diode, capacitance, or continuity tests, ensure the circuit is powered off and all high-voltage capacitors are discharged.
- Do not measure resistance or perform buzzer tests on live circuits.
- Before current measurement, check the meter's fuse and turn off the power to the circuit under test.
- When performing repairs on high-amplitude voltage circuits (e.g., TVs, power conversion), take care to avoid damaging the meter.
- The meter uses three AAA 1.5V batteries. Ensure they are correctly installed.
- Replace batteries immediately when the low voltage symbol [battery icon] appears to prevent inaccurate readings and potential electric shock.
- Do not exceed 1000V for Category II voltages or 600V for Category III voltages.
- Do not operate the instrument if its housing or parts are removed.
2.3 Safety Symbols
The following symbols are used on the meter and in this manual:
| Symbol | Description |
|---|---|
| ! | Warning: Important safety signs. Refer to the instruction manual before use. Improper use can result in damage to the device or its parts. |
| ~ | AC (Alternating Current) |
| - | DC (Direct Current) |
| ~- | AC or DC |
| ❐ | Ground |
| □□ | Double insulation protection |
| ⚠ | Fuse |
| CE | Meets EU standards |
| ⚡ | High voltage warning |
| CAT II | Category II: 1000V overvoltage protection |
| CAT III | Category III: 600V overvoltage protection |
3. Product Components and Panel Diagram
Familiarize yourself with the layout of your NJTY T-58D Digital Multimeter.

- Illumination
- NCV sensing area
- NCV and buzzer indicator light
- LED display
- Peak to Peak Measurement
- Range switching button
- Functions switch button
- Lighting/Backlight
- Gear rotary switch
- VΩHz°C input socket
- COM input socket
- 10A input socket
- µA mA input socket
- Data hold/relative value measurement
- Maximum and minimum switching
4. Display Symbols
The LCD display uses various symbols to indicate the meter's status and measurement modes:
| Symbol | Description |
|---|---|
| [Battery icon] | Battery low voltage display |
| AUTO | Auto power off |
| - | Negative polarity input indication |
| AC | Alternative input indication |
| DC | Direct input indication |
| ♫ | In continuity test mode |
| →|← | In diode test mode |
| AUTO | Auto ranging mode |
| H | Data hold mode |
| △ | In relative value measurement mode |
| PEAK | Peak-to-peak measurement mode |
| MAX | Maximum value |
| MIN | Minimum value |
| °C, °F | Temperature unit |
| % | Duty cycle |
| ⚡ | High voltage danger warning (displayed when DC voltage is 60V or AC voltage is above 36V) |
| V, mV | Volt, unit of Voltage |
| A, mA, µA | Ampere, unit of current |
| Ω, kΩ, MΩ | Ohm, unit of resistor |
| MkHz | Hz, hertz, unit of frequency |
| mF, µF, nF | Farad, unit of capacitance |
5. Button Functions and Input Sockets
5.1 Button Functions
| Button | Instructions |
|---|---|
| FUNC | Short press to select functions within a gear (e.g., °C/°F switch, AC/DC switching, Hz/% switching, diode/resistance/continuity switching). |
| A REL HOLD | Long press (2S) for Relative Value Measurement (press again for 2S to exit). Short press for Data Hold (press again to cancel). |
| ☀️/🔦 | Short press to turn on/off backlight. Long press (2S) to turn on backlight and flashlight simultaneously (press again to turn off). Automatically turns off after 30s if not pressed. |
| RANGE | Switches between manual and auto range for Voltage/Resistance/Current measurements. |
| MAX MIN | Short press to switch between maximum and minimum value measurement. Long press (2S) to exit. |
| PEAK | In AC voltage and current signal state, short press to enter Peak-to-Peak measurement. Long press (2S) to turn off. |
5.2 Input Sockets
| Input Socket | Description |
|---|---|
| COM | Common input for all measurements, connected to the black test lead. |
| VΩHz%°C/°F | Positive input for diode, capacitor, buzzer, temperature, voltage, resistance, and frequency. Connected with the red test lead. |
| µA mA | Input socket for microampere (µA) and milliampere (mA) current measurements. |
| 10A | Positive input terminal for current up to 10A. |
6. Operation Instructions
6.1 Auto Power Off
The meter will automatically power off after approximately 15 minutes of inactivity to conserve battery. It will give audible prompts before entering hibernation mode. Press any button to restart the instrument. Pressing the "FUNC" button will cancel the automatic shutdown function, and the instrument will remain on.
6.2 ACV and DCV Measurement
⚠ Do not measure any voltage greater than 1000V DC or 750V AC RMS to prevent electric shock or damage to the instrument. Do not apply more than 1000V DC or 750VAC RMS voltage between the common and earth to prevent electric shock or damage to the instrument.
The direct voltage ranges are: 100mV, 600mV, 1V, 60V, 600V, and 1000V. The alternative voltage ranges are: 100mV, 600mV, 1V, 60V, 600V, and 750V.
- Turn the rotary switch to the "≈V/≈mV" position. The red indicator light of the corresponding input socket will flash.
- Connect the black test lead to the COM jack and the red test lead to the V jack.
- Measure the voltage value of the circuit under test.
- The reading will be shown on the LED display, along with the polarity of the end connected with the red lead.
Notes:
- In AC and DC 1V range, if there is no input or test lead connected, the meter may show a digital display. Short-circuit the "V/Ω" and "COM" terminals. If the meter displays back to zero, it is normal.
- When measuring AC voltage, the frequency of the AC voltage signal will be displayed in the upper right corner (for frequencies below 30KHz).
- When measuring DC voltage, the upper right corner will display the normal temperature.
- The AC voltage value measured by this instrument is the true effective value (True RMS), providing accurate measurements for sine waves, square waves, and triangle waves (without DC offset).


6.3 Resistance Measurement
⚠ To avoid damage to the meter or device under test, all power to the circuit under test should be cut off before measuring resistance, and all high-voltage capacitors should be fully discharged.
The unit of resistance is Ohm (Ω). The resistor ranges are: 600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ.
- Turn the rotary switch to the "Ω / →|← / ♫" position and press the "FUNC" button to select the "Ω" position. The red indicator light will flash.
- Connect the black test lead to the "COM" input socket and the red test lead to the "VΩ" input socket.
- Use the test leads to measure the resistance value of the circuit.
Notes:
- The resistance value measured on a circuit may differ from the rated resistance.
- For accurate low resistance measurements, short-circuit the test leads to read the short-circuit resistance, then subtract it from your readings.
- High resistance measurements may take a few seconds to stabilize.
- If the meter is not connected to a circuit, it will display "OL" (Overload), indicating the measurement value is out of range.

6.4 Diode Measurement
⚠ To avoid damage to the meter or device under test, all power to the circuit under test should be cut off before measuring diodes, and all high-voltage capacitors should be fully discharged.
To test a diode outside the circuit:
- Turn the rotary switch to the "Ω / →|← / ♫" position and press the "FUNC" button to select the "→|←" position. The red indicator light will flash.
- Connect the black test lead to the "COM" input socket and the red test lead to the "VΩ" input socket.
- Connect the black test lead to the negative electrode and the red test lead to the positive electrode of the diode under test.
- The meter will display the forward bias value of the diode. If the polarity is reversed, it will show "OL".

6.5 Buzzer Test (Continuity)
⚠ To avoid damage to the meter or device under test, all power to the circuit under test should be cut off before measuring continuity, and all high-voltage capacitors should be fully discharged.
- Turn the rotary switch to the "Ω / →|← / ♫" position and press the "FUNC" button to select the "♫" position. The red indicator light will flash.
- Connect the black test lead to the "COM" input socket and the red test lead to the "VΩ" input socket.
- If the resistance of the circuit is not greater than approximately 50 ohms, the indicator light will turn on and the buzzer will sound continuously. If the resistance is between 40 ohms and 1000 ohms, the resistance value will be displayed. If the resistance is greater than 1kΩ, the display will show "OL".

6.6 Capacitance Measurement
⚠ To avoid damage to the meter or device under test, all power to the circuit under test should be cut off before measuring capacitance. All high-voltage capacitors should be fully discharged.
The capacitance ranges are: 6nF, 60nF, 600nF, 6µF, 60µF, 600µF, 6mF, 60mF.
- Turn the rotary switch to the "Ω / →|← / ♫" position and press the "FUNC" button to select the capacitance position. The red indicator light will flash.
- Connect the black test lead to the "COM" input socket and the red test lead to the "VΩ" input socket.
- Measure the capacitance value of the circuit under test.
Notes:
- Measuring large capacitors may take some time.
- Always discharge large capacitors before measurement to avoid damaging the instrument.

6.7 Frequency Measurement
⚠ Do not test any voltage higher than 250V to prevent electric shock or damage to the instrument.
- Turn the rotary switch to the "Hz%" position. The red indicator light will flash.
- Connect the black test lead to the COM jack and the red test lead to the Hz jack.
- Measure the frequency value of the circuit under test.
- The reading will be shown on the LED display, and the duty cycle (%) will be displayed in the upper right corner.
6.8 NCV Test (Non-Contact Voltage)
Rotate the rotary switch to the NCV position. Place the top of the meter close to the conductor. If the meter detects AC voltage, the corresponding signal strength indicator will light up (low-yellow, high-red), and the buzzer will emit different frequency alarms.
Notes:
- Do not rely solely on non-contact voltage detectors to determine if voltage is present, as factors like socket depth, insulation thickness, and type can affect detection.
- Interference sources (e.g., flashlights, motors) may accidentally trigger NCV detection.

6.9 Temperature Measurement
- Turn the rotary switch to the "°C/°F" position. The instrument will directly display the ambient temperature. The red indicator light of the socket will flash.
- Remove the test leads and connect the thermocouple with the correct polarity to the "COM" and "V/Ω" inputs.
- Place the thermocouple on the surface of the object being measured or in the environment.
- The display will show the temperature measurement value.

6.10 Current Measurement
⚠ When measuring current, the meter needs to be connected in series to the circuit under test. Do not attempt to measure circuits in parallel or measure mains power in parallel. If the fuse blows while taking measurements, you may damage the meter or injure yourself.
To avoid damage to the instrument or the equipment under test, pre-judge the size of the current, select the corresponding current gear, and check the fuse.
The DC current ranges are: 600 µA, 6mA, 60mA, 600mA, 6A, and 10A. AC current ranges are: 600 µA, 6mA, 60mA, 600mA, 6A, and 10A.
- Turn the rotary switch to the appropriate current position (µA, mA, or 10A). The red indicator light of the corresponding input socket will flash.
- Connect the black test lead to the "COM" input socket. If the measured current is less than 1A, connect the red test lead to the "mA" input socket. If the measured current is between 1A and 10A, connect the red test lead to the "10A" input socket.
- Connect the test leads to the circuit under test in series. Turn on the power of the circuit, and the current measurement value will be displayed.


7. Technical Specifications

7.1 Comprehensive Indicators
- Operating Conditions: 600V CAT III and 1000V CAT II, Height: under 2000m, Pollution grade: 2
- Working Temperature: 0-40°C (<80%RH, not considered <10°C)
- Storage Temperature: -10-60°C (<80%RH, remove battery)
- Test or Calibration Ambient Temperature: 20°C ± 2°C
- Max Voltage between Measurement End and Ground: 1000V DC or 750V AC
- Fuse Protection: mA range: F 600mA/250V; 10A range: F 10A/250V
- Conversion Rate: Approximately 3s/second
- Display: 60000 counts LED display
- Overload Display: 'OL' displayed
- Low Voltage Display: [Battery icon] displayed when working voltage is low
- Input Polarity Indicator: '-' shown automatically
- Battery: 3 x 1.5V AAA
- Size: 187mm (L) * 95mm (W) * 55mm (H)
- Weight: Approximately 331g (excluding battery)

7.2 Functional Parameters
| Parameter | Range/Value | Accuracy |
|---|---|---|
| Model | T58D | |
| AC Current | 0.01uA ~ 10A | ±(5%+10) |
| DC Current | 0.01uA ~ 10A | ±(1%+10) |
| AC Voltage | 0.001MV ~ 750V | ±(1.2%+10) |
| DC Voltage | 0.001MV ~ 1000V | ±(1%+5) |
| Resistance (Ω) | 0.001Ω ~ 60MΩ | ±(1.5%+5) |
| Capacitance | 0.001nF ~ 60mF | ±(5%+5) |
| Frequency | 0.001Hz ~ 25MHz | ±(1.5%+5) |
| Temperature | (-20 ~ 1000°C) | ±(1.0%+3) |
| Diode | Forward DC voltage approx. 3.2V, current approx. 1mA | |
| Buzzer On/Off | √ | |
| NCV | √ | |
| Data Hold | √ | |
| Backlight / Flashlight | √ | |
| Range Switch | √ | |
| Auto Power Off | √ | |
| Low Battery Indicator | √ | |
| Display | 60,000 counts | |
| Power Supply | AAA*3 Battery | |
| Body Size | 187*95*55 (mm) | |
| Body Weight | Approx. 331g (excluding battery) |
8. Maintenance
8.1 General Maintenance
- To avoid electric shock or damage, do not get the inside of the meter wet.
- Before opening the case or battery compartment, turn off the power and ensure test leads are disconnected.
- Clean the instrument case regularly with a damp cloth and a small amount of detergent. Do not use abrasives or chemical solvents.
- Dirty or moist surfaces can cause oxidation, affecting readings.
8.2 Cleaning Input Sockets
- Turn off the meter and unplug all test leads.
- Remove any dirt from the socket.
- Clean each socket with a new cotton ball moistened with detergent or lubricant. Lubricant can prevent moisture-related contamination.
9. Battery and Fuse Replacement
⚠ Replace batteries and fuses to avoid electric shock or personal injury caused by erroneous readings. When the low battery symbol [battery icon] appears on the instrument display, replace the battery immediately. Use only the specified fuse (instant fuse).
The meter uses three 1.5V AAA batteries.

Follow these steps to replace the battery:
- Turn off the instrument.
- Pull all test leads out of the input sockets.
- Use a screwdriver to loosen the screws fixing the battery cover.
- Remove the battery cover.
- Remove the old battery or the damaged fuse.
- Replace with new 3 x 1.5V AAA batteries or a new fuse (the spare fuse is located under the battery cover).
- Install the battery cover and close the screws.
10. Accessories
The following items are included with your NJTY T-58D Digital Multimeter:
- One instruction manual (PDF version available: View User Manual PDF)
- One pair of test leads
- One thermocouple
- 3 x 1.5V AAA batteries
- A canvas bag

11. Troubleshooting
- "OL" Display: If the display shows "OL" (Overload), it means the measured value is out of the selected range. Try switching to a higher range or ensure the circuit is not open.
- Inaccurate Readings: Check battery level. If the low battery symbol is displayed, replace the batteries. Ensure test leads are properly connected and not damaged. Verify the correct function and range are selected.
- No Display/Power: Check if the batteries are correctly installed and have sufficient charge. If the auto power-off function was active, press any button to restart.
- No Buzzer Sound in Continuity Test: Ensure the resistance is below 50 ohms. Check test lead connections.
- NCV Not Detecting: Ensure the top of the meter is close to the conductor. Be aware that external interference can affect detection.
12. User Tips
- Transistor Testing: While this specific model does not explicitly list transistor testing as a direct function, many multimeters can perform basic checks on transistors using the diode test function to measure the forward voltage drop of the PN junctions. Consult advanced guides for detailed methods.
- Battery Life: Always turn off the multimeter when not in use to extend battery life, even with the auto power-off feature.
- Probe Care: Keep your test probes clean and free from damage. Damaged probes can lead to inaccurate readings and safety hazards.
- Environmental Factors: Be mindful of temperature and humidity, as extreme conditions can affect the meter's accuracy and lifespan.
13. Warranty and Support
For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your purchase receipt as proof of purchase.