1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of your EASUN POWER Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
1.1 Product Overview
The EASUN POWER Hybrid Solar Inverter is a multi-function inverter/charger designed to provide uninterruptible power support. It combines the functions of an inverter, solar charger, and battery charger. The comprehensive LCD display allows for user-configurable and easy-accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges for various applications.
This inverter can power a wide range of appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.
1.2 Key Features
- Pure sine wave output.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Auto restart while AC is recovering.
- Overload, over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- WIFI/GPRS available for iOS and Android (optional module may be required).
Note: For SMH-II 2.2KW and 3.2KW models, the inverter must be connected to a battery to operate. SMH-III 4.2KW and 6.2KW models can operate without a battery.
1.3 Basic System Architecture
The inverter integrates solar power, generator/utility grid, battery packs, and home appliances into a cohesive power system.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation, please follow required specifications to select appropriate cable sizes. It is very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedures when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.
3. Setup and Installation
3.1 Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- The inverter unit x 1
- User manual x 1
3.2 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Make sure that other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and that there is enough room to remove the wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two screws. It's recommended to use M6 screws.
3.3 Product Overview (Physical)

Rear Panel Connections:
- Power on/off switch
- AC input
- Main output
- Second output
- PV input
- Battery communication/RS-485 port
- WIFI communication/RS-232 port
- Battery input
3.4 Wiring Connections
Before connecting any wires, remove the screws under the machine and remove the bottom cover plate.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cables. To reduce risk of injury, please use the proper recommended cable sizes.
3.4.1 Battery Connection
CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
Recommended battery cable size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Steps for Battery Connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below (example for 3.6KW/4.2KW and 6.2KW models).
- Insert the battery wires flatly into the battery connectors of the inverter and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Make sure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.4.2 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input.
The recommended spec of AC breaker is 32A for 3.6KW/4.2KW and 50A for 6.2KW.
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
Suggested cable requirement for AC wires:
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW/4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Steps for AC Input/Output Connection:
- Before making AC input/output connection, be sure to open the DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. (L→LINE (brown or black), N→Neutral (blue)).
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten the terminal screws. (L→LINE (brown or black), N→Neutral (blue)).
- Make sure the wires are securely connected.
CAUTION: Appliances such as air conditioners require at least 2-3 minutes to restart. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter/charger may trigger an overload fault.
3.4.3 PV Connection
CAUTION: Before connecting to PV modules, install separately a DC circuit breaker between the inverter and PV modules.
Recommended cable size for PV module connection:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, consider the following parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 3.6KW/4.2KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | 500Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | 60Vdc~450Vdc |
Steps for PV Module Connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Connect the positive pole (+) of the connection wire to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection wire to the negative pole (-) of the PV input connector. Recommended tool: 4mm blade screwdriver.

3.4.4 Final Assembly
After connecting all wirings, put the bottom cover back by screwing two screws.
3.4.5 Communication Connection
1. Wi-Fi Cloud Communication (Option):
Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown by the mobile phone APP or webpage of a computer.
2. GPRS Cloud Communication (Option):
Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the APP and install it from the APP store, and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown by the mobile phone APP or webpage of a computer.

3.4.6 Battery Communication (for Lithium Batteries)
The communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and the lithium battery to exchange information (Baud rate: 9600).
Lithium battery and inverter connection:
If choosing a lithium battery for the inverter, only lithium batteries that have been matched with BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and that the ring terminal is tightened with the battery terminal.
- Connect one side of the RJ45 cable to the BMS communication port of the inverter.
- Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.
NOTE: If you choose a lithium battery, please make sure to connect the battery and inverter with a BMS communication cable, and select the battery type as "LIB-485" mode in program 05.
Inverter BMS Port PIN Definition:
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |
3.4.7 Installation Video Guide
Watch this video for a step-by-step guide on connecting the inverter:
Video Steps Summary:
- (0:00 - 0:25) Connect the battery to the positive and negative terminals of the inverter.
- (0:26 - 0:34) Connect the battery communication cable to the LiFePO4 battery.
- (0:35 - 0:53) Connect the positive and negative utility wires to the inverter.
- (0:54 - 1:09) Connect the ground wire to the inverter.
- (1:10 - 1:21) Connect the PV input wires from the solar panel to the inverter.
- (1:22 - 1:27) Turn on the battery switch and the inverter power switch.
- (1:28 - 1:41) Connect to utility power and observe the inverter display.
4. Operating Instructions
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The operation and display panel is on the front of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

LED Indicators:
| LED Indicator | Messages |
|---|---|
| AC / INV (Green Solid On) | Output is powered by utility in Line mode. |
| AC / INV (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides various icons to indicate the inverter's status and information:
- Input Source Information: Icons for AC input, PV input.
- Configuration Program and Fault Information: Icons for setting programs, warning codes (flashing), and fault codes (lighting).
- Output Information: Displays output voltage, frequency, load percentage, load in VA/Watt, and discharging current.
- Battery Information: Icon for battery status.
- Load Information: Icon for overload.
- Mode Operation Information: Icons for unit connected to mains, PV panel, load supplied by utility, utility charger working, DC/AC inverter working.
- Mute Operation: Icon for disabled unit alarm.
4.4 LCD Setting
To enter setting mode, press and hold the "ENTER" button for 3 seconds. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit.
Key Settings:
- Program 00: Exit setting mode / One-button restore setting options.
- Program 01: Output Source Priority: Configures load power source priority (Utility first, Solar first, SBU priority, MKS priority).
- Program 02: Maximum Charging Current: Configures total charging current for solar and utility chargers.
- Program 03: AC Input Voltage Range: Sets acceptable AC input voltage range (Appliances, UPS).
- Program 05: Battery Type: Selects battery type (AGM, Flooded, User Defined, LIB-485). For lithium batteries, select "LIB-485" and ensure BMS communication.
- Program 06: Auto Restart When Overload Occurs: Enables or disables auto restart after overload.
- Program 07: Auto Restart When Over Temperature Occurs: Enables or disables auto restart after over temperature.
- Program 09: Output Frequency: Sets output frequency (50Hz/60Hz).
- Program 10: Output Voltage: Sets output voltage (220V/230V/240V).
- Program 11: Maximum Utility Charging Current: Sets maximum charging current from utility.
- Program 12: Setting Voltage Point Back to Utility Source: When selecting "SBU priority" or "Solar first" in program 01, sets the battery voltage point to switch back to utility.
- Program 13: Setting Voltage Point Back to Battery Mode: When selecting "SBU priority" or "Solar first" in program 01, sets the battery voltage point to switch back to battery mode.
- Program 16: Charger Source Priority: Configures charger source priority (Solar first, Solar and Utility, Only Solar).
- Program 18: Alarm Control: Enables or disables audible alarms.
- Program 19: Auto Return to Default Display Screen: Sets whether the display returns to default after inactivity.
- Program 20: Backlight Control: Turns backlight on or off.
- Program 22: Beeps While Primary Source is Interrupted: Enables or disables beeps when primary source is interrupted.
- Program 23: Overload Bypass: When enabled, the unit transfers to line mode if overload occurs in battery mode.
- Program 25: Record Fault Code: Enables or disables fault code recording.
- Program 26: Bulk Charging Voltage (C.V voltage): Sets the bulk charging voltage.
- Program 27: Floating Charging Voltage: Sets the floating charging voltage.
- Program 29: Low DC Cut-off Voltage: Sets the low DC cut-off voltage.
- Program 30: Battery Equalization: Enables or disables battery equalization.
- Program 31: Battery Equalization Voltage: Sets the battery equalization voltage.
- Program 33: Battery Equalized Time: Sets the duration for battery equalization.
- Program 34: Battery Equalized Timeout: Sets the timeout for battery equalization.
- Program 35: Equalization Interval: Sets the interval between equalization cycles.
- Program 36: Equalization Activated Immediately: Activates equalization immediately.
- Program 37: GRID-tie Operation: Sets the inverter to off-grid or hybrid mode.
- Program 38: GRID-tie Current: Sets the grid-tie current.
- Program 39: Led Pattern Light: Sets the LED pattern.
- Program 41: Dual Output: Enables or disables dual output.
- Program 42: Enter the Dual Output Functional Voltage Point: Sets the voltage point for dual output function.
- Program 43: Lithium Battery Protocol: Selects the lithium battery protocol (PYLON, PACE).
- Program 44: Delayed Grid Access: Enables or disables delayed grid access.
- Program 45: Maximum Second Load: Sets the maximum second load percentage.
4.5 Operating Mode Description
The inverter operates in various modes, each with specific characteristics:
- Standby Mode: The inverter is not turned on, but can still charge batteries without AC output.
- Line Mode: The unit provides output power from the mains and charges the battery.
- Grid-Tie Operation: Inverter operates in hybrid mode, prioritizing solar energy for loads and charging, with excess energy fed to the grid.
- Battery Mode: The unit provides output power from the battery and solar power.
4.6 RGB Light (Option)
The inverter may feature RGB indicator lights:
- Battery Mode: Red Light
- Utility Mode: Blue Light
- PV Mode: Purple Light
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Every inverter is installed with an anti-dust kit from the factory. This kit helps keep dust out and increases product reliability. The inverter automatically detects the kit and adjusts its internal thermal sensor to maintain optimal internal temperature.
Maintenance Steps:
- Loosen the screw in a counterclockwise direction on the top of the inverter.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
5.2 Battery Equalization
Battery equalization is a function that reverses the buildup of negative chemical effects like stratification (uneven acid concentration) and removes sulfate crystals from the battery plates. It's recommended to equalize the battery periodically.
How to Apply Equalization Function:
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function by either of the following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
When to Equalize:
In the float stage, when the setting equalization interval (battery equalization cycle) is reached, or equalization is activated immediately, the controller will start to enter the Equalize stage.
5.3 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts to work.
- If the inverter is in lithium battery mode (item 05 is LIB or LIB-485) and the mains are connected but the battery is not, the mains activation function is automatically enabled.
6. Troubleshooting
This section provides common issues, their causes, and solutions. For persistent errors, contact a qualified service center.
6.1 Fault Reference Code
When a fault occurs, the LCD will display a fault code. Refer to the table below for explanations.
| Fault Code | Fault Event |
|---|---|
| 01 | Fan is locked when inverter is off. |
| 02 | Over temperature |
| 03 | Battery voltage is too high |
| 04 | Battery voltage is too low |
| 05 | Output short circuited or over temperature is detected by internal converter components. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 51 | Over current or surge. |
| 52 | Bus voltage is too low. |
| 53 | Inverter soft start failed. |
| 55 | Over DC voltage in AC output. |
| 57 | Current sensor failed. |
| 58 | Output voltage is too low. |
| 59 | PV voltage is over limitation. |
6.2 Warning Indicator
The inverter provides warning indicators for various conditions.
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| E9 | Battery equalization | None |
| bP | Battery is not connected | None |
6.3 General Troubleshooting
| Problem | Explanation / Possible cause | What to do |
|---|---|---|
| Unit shuts down automatically during startup process. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but the unit works in battery mode. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. |
| When the unit is turned on, internal relay is switched on and off repeatedly. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Overload error. The inverter is overloaded 110% and time is up. | Reduce the connected load by switching off some equipment. |
7. Specifications
7.1 Line Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Nominal Input Voltage | 230Vac | ||
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | ||
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | ||
| High Loss Voltage | 280Vac±7V | ||
| High Loss Return Voltage | 270Vac±7V | ||
| Max AC Input Voltage | 300Vac | ||
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | ||
| Low Loss Frequency | 40±1Hz | ||
| Low Loss Return Frequency | 42±1Hz | ||
| High Loss Frequency | 65±1Hz | ||
| High Loss Return Frequency | 63±1Hz | ||
| Output Short Circuit Protection | Circuit Breaker | ||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | ||
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | ||
7.2 Inverter Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Rated Output Power | 3.6KW | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | ||
| Output Voltage Regulation | 230Vac±5% | ||
| Output Frequency | 50Hz | ||
| Peak Efficiency | 93% | ||
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | ||
| Surge Capacity | 2* rated power for 5 seconds | ||
| Nominal DC Input Voltage | 24Vdc | 48Vdc | |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc | |
| Low DC Warning Voltage @load < 50% | 22.0Vdc | 44.0Vdc | |
| Low DC Warning Voltage @load ≥ 50% | 21.0Vdc | 42.0Vdc | |
| Low DC Warning Return Voltage @load < 50% | 22.5Vdc | 45.0Vdc | |
| Low DC Warning Return Voltage @load ≥ 50% | 22.0Vdc | 44.0Vdc | |
| Low DC Cut-off Voltage @load < 50% | 20.5Vdc | 41.0Vdc | |
| Low DC Cut-off Voltage @load ≥ 50% | 20.0Vdc | 40.0Vdc | |
| High DC Recovery Voltage | 32Vdc | 62Vdc | |
| High DC Cut-off Voltage | 33Vdc | 63Vdc | |
| No Load Power Consumption | 30W | 35W | 50W |
7.3 Two Load Output Power
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Full Load | 3600W | 4200W | 6200W |
| Maximum Main Load | 3600W | 4200W | 6200W |
| Second Load Range | 720W~2520W | 840W~2940W | 1240W~4340W |
| Main Load Cut Off Voltage | 22VDC | 44VDC | |
| Main Load Return Voltage | 26VDC | 52VDC | |
7.4 MPPT Solar Charging Mode
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Max. PV Array Power | 6200W | 6500W | |
| Nominal PV Voltage | 240Vdc | 360Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | ||
| Max. PV Array Open Circuit Voltage | 500Vdc | ||
| Max Charging Current (AC charger plus solar charger) | 120Amp | 120Amp | 120Amp |
7.5 Grid-Tie Operation
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | ||
| Feed-in Grid Voltage Range | 195~253VAC | ||
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | ||
| Nominal Output Current | 15.7A | 18.2A | 26.9A |
| Power Factor Range | >0.99 | ||
| Maximum Conversion Efficiency (DC/AC) | 97% | ||
7.6 General Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Safety Certification | CE | ||
| Operating Temperature Range | -10°C to 50°C | ||
| Storage temperature | -15°C~60°C | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Dimension (D*W*H), mm | 358×442×116 | ||
| Net Weight, kg | 8.0 | 8.0 | 8.9 |
8. User Tips
- Inverter Turns On and Off: If the inverter attempts to power on but then shuts off, first check all battery connections to ensure they are secure and correctly polarized. Verify that the battery voltage is within the acceptable range for the inverter model. Refer to the troubleshooting section for specific fault codes.
- Wi-Fi Connectivity Issues: If the Wi-Fi functionality is not working, ensure that the Wi-Fi adapter is correctly connected. In the LCD settings (Program 05), confirm that the battery type is set to "USE" to enable Wi-Fi. Follow the "Wi-Fi Plug Quick Installation Guideline" for setup.
- LiFePo4 Battery Compatibility: The inverter is compatible with LiFePo4 batteries. When using them, ensure that the battery type in Program 05 is set to "LIB-485" mode and that the correct BMS communication protocol (e.g., PYLON or PACE in Program 43) is selected and properly connected via the RJ45 communication cable.
- Battery Requirement: Remember that SMH-II 2.2KW and 3.2KW models require a connected battery to function, while SMH-III 4.2KW and 6.2KW models can operate without a battery.
9. Warranty and Support
This product is covered by a manufacturer's warranty. For warranty claims, technical support, or service, please contact your local dealer or the authorized service center. Do not attempt to repair the unit yourself, as this may void the warranty and pose safety risks. Only qualified personnel should perform repairs.