1. Introduction
The JIKONG Smart Active Balance Battery Management System (BMS) is an intelligent power management solution designed for various battery chemistries, including Li-ion, LiFePO4, and LTO. This advanced BMS supports battery configurations from 8S to 24S series and offers continuous discharge currents ranging from 100A to 300A, depending on the model. It features active balancing for lossless energy redistribution, ensuring systematic safety and extending battery life. The system integrates real-time data monitoring, dynamic parameter configuration, and multi-level alarm functions accessible via dedicated mobile applications (iOS, Android, HarmonyOS) and PC software.

Figure 1: JIKONG Intelligent Active Balanced Power Management System (BMS)
2. Specifications
The JIKONG Smart Active Balance BMS is engineered with high-performance components and a robust design to ensure reliability and efficiency. Key specifications include:
- Brand Name: JIKONG
- Handware or Smart: SMART BMS
- Type: Li-ion / LiFePO4 / LTO Battery BMS
- Battery Series: 4S-24S (model dependent)
- Balance Function: Active Balanced BMS (1A-2A high current balance)
- Charging Current: Up to 200A (model dependent)
- Continuous Discharge Current: 100A - 300A (Optional, model dependent)
- Charge and Discharge Port: Common Port BMS
- Function: Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
- Other Features: Temperature protection, Heating Function, Support Parallel Connection, Coulomb Counter
- Supported Interfaces: RS485/CAN/UART/HEAT/APP/BT
- Adapting System: Android, iOS, HarmonyOS, PC
- Certification: CE, FCC, RoHS, UL
- Usage Scenario: Power BMS, Energy Storage BMS
2.1 Product Dimensions

Figure 2: JIKONG BMS Dimensions (Note: Data tolerance range is ±2mm)

Figure 3: Dimensions for various JIKONG BMS models
2.2 Product Parameters (Example: FWVer 1.9.0)

Figure 4: Product Parameters for JIKONG Inverter BMS (FWVer 1.9.0) - Part 1

Figure 5: Product Parameters for JIKONG Inverter BMS (FWVer 1.9.0) - Part 2
3. Package Contents
Upon opening your JIKONG BMS package, please verify that all components are present and undamaged. The standard packing list includes:
- BMS Unit x 1
- Switch x 1 (long 50cm)
- NTC Temperature Sensor x 1 (long 40cm)
- Sampling Line B x 1 (long 70cm)
- Sampling Line A x 1 (long 70cm)
- Packaging Box
Video 1: Unboxing and contents of the JIKONG Smart Active Balance BMS package.

Figure 6: JIKONG BMS Packing List
4. Installation and Wiring
Proper installation and wiring are crucial for the safe and efficient operation of your JIKONG BMS. Please follow these steps carefully:
4.1 General Wiring Procedure
- First, weld B-, P-, B+, and then insert the battery sampling cable in order from low to high.
- Activate after power on, make sure all cables are correctly connected, and then add the load and charger.
- When disassembling, first disconnect the charger and load, unplug the battery sampling cable in order from high to low, and finally unplug B+, P+, B-.
4.2 Wiring Diagrams
Refer to the following diagrams for specific battery string configurations:

Figure 7: Wiring Method for 24-String Cells

Figure 8: Wiring Method for 16-String Cells

Figure 9: Wiring Method for 4-String Cells
5. Operating Instructions
The JIKONG BMS offers comprehensive monitoring and control capabilities through its dedicated mobile app, PC software, and optional LCD display.
5.1 Mobile App (Android/iOS/HarmonyOS)
The BMS dedicated APP supports cross-platform access, providing real-time data monitoring (voltage, temperature, SOC, etc.), dynamic parameter configuration, and multi-level alarm push functions. It adapts to multi-terminal collaborative operations and integrates multi-language switching modules to meet global usage needs, realizing full-scenario intelligent monitoring of battery status.

Figure 10: Mobile App Interface for JIKONG BMS
5.2 PC Software Interconnection
Communication cables (UART/RS485/CAN) are intelligently interconnected with the host PC, featuring simple operation, real-time viewing of all data, more comprehensive functions, and setting calibration capabilities, while supporting firmware version updates and upgrades. With one click, you can view multiple information such as voltage, current, temperature, and number of strings.

Figure 11: PC Software Interface for JIKONG BMS
5.3 Optional LCD Touch Screen Display
The optional 4.3-inch LCD touch screen provides an intuitive interface for monitoring and setting parameters directly. It offers:
- Parallel Monitoring: Supports one-click viewing and setting of parameter status for multiple parallel battery packs.
- Touch Setting: Multi-dimensional parameter adjustment for flexible and accurate system configuration.
- Real-time Status: Clearly and intuitively displays important data such as battery voltage, capacity, and current.
- Upgraded Functions: Provides more setting options and control functions compared to previous versions.
- Streamlined Interface: Intuitive and easy-to-understand interface design.

Figure 12: JIKONG 4.3-inch LCD Touch Screen Display
5.4 Communication Modes and Interfaces
The JIKONG BMS supports various communication modes and interfaces to meet diverse application needs:
- CAN: Controller Area Network for robust communication.
- RS485: Serial communication standard for industrial applications.
- BT (Bluetooth): Wireless connectivity for mobile app.
- NTC: Negative Temperature Coefficient thermistor for temperature monitoring.
- Soft Switch: For power control.
- SOC Indicator: State of Charge indicator.
- Key Switch: Physical switch for control.
- Active Equalizer: For active cell balancing.

Figure 13: BMS Interface Overview
5.5 Protocol Docking
The JIKONG BMS is compatible with mainstream inverter communication protocols in the market, allowing for seamless integration with various power systems. This includes protocols such as Deye, Pylontech, Growatt, Victron Energy, INVT, and others.

Figure 14: Compatible Inverter Protocols and Mobile App Protocol Settings
6. Maintenance
To ensure the longevity and optimal performance of your JIKONG Smart Active Balance BMS, consider the following maintenance guidelines:
- Regular Inspection: Periodically check all wiring connections for tightness and signs of corrosion. Ensure the BMS unit is securely mounted and free from physical damage.
- Software Updates: Keep the mobile app and PC software updated to the latest versions to benefit from new features, performance improvements, and bug fixes. Firmware updates for the BMS can also be performed via the PC software.
- Environmental Conditions: Ensure the BMS operates within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, direct sunlight, or moisture.
- Cleaning: Gently clean the exterior of the BMS unit with a dry, soft cloth. Do not use harsh chemicals or abrasive materials.
- Data Logging: Regularly review logged data for any unusual patterns or warnings that might indicate potential issues. Export diagnostic data if needed for troubleshooting.
7. Troubleshooting
If you encounter issues with your JIKONG BMS, refer to the following common troubleshooting steps:
- No Power/No Display:
- Check all power connections (B-, P-, B+) to ensure they are secure and correctly wired.
- Verify the battery voltage is within the operating range of the BMS.
- If using an external display, ensure its connection cable is properly seated.
- App/PC Software Connection Issues:
- For Bluetooth (BT) connection, ensure Bluetooth is enabled on your mobile device and the BMS is discoverable.
- For RS485/CAN connections, verify the communication cables are correctly connected and the drivers are installed on your PC.
- Check the communication settings in the app/software to match the BMS configuration.
- Balancing Not Active/Uneven Cell Voltages:
- Ensure all cell sampling lines are correctly connected from low to high.
- Check the balancing settings in the app/software to ensure active balancing is enabled and configured appropriately.
- Verify that the battery cells are healthy and within their specified voltage range.
- Overcharge/Over-discharge Protection Triggered:
- Check the charger and load to ensure they are operating correctly.
- Review the protection parameters in the app/software and adjust if necessary, ensuring they align with your battery specifications.
- Inspect individual cell voltages for any anomalies.
- Error Codes/Alarms:
- Refer to the app or PC software for specific error code definitions and recommended actions.
- Address the root cause of the alarm (e.g., high temperature, overcurrent).
If the issue persists after following these steps, please contact JIKONG customer support for further assistance.
8. User Tips
This section would typically include helpful advice and common solutions based on user feedback and frequently asked questions. As no specific user reviews or Q&A data were provided, general tips for BMS usage are offered:
- Initial Setup: Always connect the balance wires from the lowest cell voltage to the highest cell voltage first, and disconnect in reverse order. This prevents damage to the BMS.
- Parameter Customization: Take advantage of the app's detailed parameter settings to fine-tune the BMS performance to your specific battery pack and application requirements.
- Temperature Monitoring: Pay close attention to cell temperature readings, especially during high charge/discharge cycles, to prevent overheating and ensure battery health.
- Parallel Systems: When connecting multiple BMS units in parallel, ensure proper communication and synchronization as per the advanced setup instructions or consult JIKONG support.
9. Warranty and Support
JIKONG products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official JIKONG website or contact your authorized dealer. Ensure you have your product model number and purchase details ready when seeking support.

Figure 15: JIKONG Customer Support