1. Introduction
The LILYTECH ZL-7863A is a versatile temperature and humidity controller designed for applications requiring precise climate control, such as greenhouses, reptile habitats, and animal enclosures. It features two timer outputs for illumination, ventilation, or air inlet/exhaustion, with customizable day and night settings for temperature and humidity. The controller supports heating, cooling, humidifying, and dehumidifying functions, including optional heat pump control and compressor delay protection. It provides over-temperature and wet-level warnings and restarts after power supply interruptions. Equipped with both humidity and temperature sensors, it offers high accuracy and control resolution.
Video: ZL-7863A Product Overview (Rotating View)
Figure 1: ZL-7863A Controller and Sensors
2. Specifications
| Feature | Description |
|---|---|
| Power Supply | 100 ~ 240Vac, 50/60Hz |
| Output | 3A@250Vac, for all 7 outputs. (Use intermediate relay 10A~40A, SSR-XXAA, or magnetic contactor for bigger loads) |
| Input | 1x Humidity sensor (2m cable), 1x Temperature sensor (R10K@C25/B3470@25/50 °C, 2m cable) |
| Humidity Sensor Options | ZL-SHr05J (for <80%RH), ZL-SHr05P (for >80%RH) |
| Setting Range | Humidity: 0 ~ 99%RH, Temperature: 0 ~ 65°C |
| Sensor Precision | Humidity: ±2%(ZL-SHr05P), ±3%(ZL-SHr05J), Temperature: ±1% @ 25°C |
| Control Resolution | Humidity: 1%RH, Temperature: 0.1°C |
| Working Environment | -10 ~ 45°C; ≤ 90%RH without dew |
| Case Dimension | L78 x W34.5 x D71 (mm) |
| Drilling Size | L 71 x W29 (mm) |
| Case Materials | PC + ABS, fireproof |
| Protection Level | IP65 (Front panel only) |
| Material | Plastic |
| Origin | Mainland China |
| Weight | 0.3 kg |
| Key Selling Points | High-accuracy |
| Core Components | PCB |
3. Setup and Installation
Important: Please read these instructions carefully. Electrical wiring must be performed by a certified electrician. Incorrect wiring can seriously damage the device and system.
3.1 Wiring Diagram
The ZL-7863A controller supports various configurations for heating and cooling. Below are the wiring diagrams for common setups.
Figure 2: Wiring Diagram for Heating by Heater
Figure 3: Wiring Diagram for Heating by Compressor
Note: The outputs R1-R7 are rated at 3A / 250Vac. For larger loads, an intermediate relay (10A~40A, SSR-XXAA, or magnetic contactor) must be used.
3.2 Sensor Connection
Connect the humidity and temperature sensors to the designated ports (8 and 9) on the controller. Ensure secure connections.
Figure 4: Humidity Sensor Options
Choose the appropriate humidity sensor based on your application:
- ZL-SHr05J: For humidity lower than 80%RH.
- ZL-SHr05P: For humidity higher than 80%RH.
4. Operation
4.1 Front Panel and Display
The front panel features a digital display and four buttons for operation.
Figure 5: Front Panel Layout
Buttons:
- ن (Power): Press and hold for 3 seconds to switch between online and offline mode. A quick press shows the current time for 3 seconds.
- S (Set): Used to enter parameter setting mode and confirm selections.
- ▼ (Down Arrow): Decreases values or navigates menus.
- ▲ (Up Arrow): Increases values or navigates menus.
4.2 Key Operations
On/Offline Set:
- Keep ن depressed for 3 seconds to switch between online and offline.
- Click ن to show the current time for 3 seconds.
Fast Set Temperature (L4 or L6) and Set Humidity (L5 or L7) of Current Moment:
- Press S to enter fast setting status. The current setpoints will display.
- Press S again to switch between set temperature and humidity settings. The selected value will blink.
- Press ▼ or ▲ to set the blinking value (keeping depressed will set fast).
- Keep S depressed for 3 seconds to save the setting and exit.
- The setting status will exit without saving if there is no key operation for 15 seconds.
4.3 Parameter Setting
To access and modify all parameters:
- Keep S depressed for 3 seconds to enter parameter setting status.
- Press S or ن to select the parameter code.
- Press ▼ or ▲ to set the value of the code (keeping depressed will set fast).
- Keep S depressed for 3 seconds to save the setting and exit.
- The setting status will exit without saving if there is no key operation for 30 seconds.
Refer to the Parameter Table in the official PDF manual for a complete list of parameters and their functions.
4.4 Control Functions
The ZL-7863A offers comprehensive control over temperature and humidity:
4.4.1 Temperature Control (t0)
- Cooling Control (t0 = 1, R7 de-energized): Controls cooling based on setpoint and hysteresis.
- Heating Control (t0 = 2): Controls heating by heater or compressor based on setpoint and hysteresis.
- Constant Temperature Control (t0 = 0): Maintains a stable temperature using both heating and cooling.
4.4.2 Humidity Control (h0)
- Constant Humidity Control (h0 = 0): Maintains a stable humidity level.
- Humidify Control (h0 = 1): Activates humidification when humidity drops below setpoint.
- De-humidify Control (h0 = 2): Activates dehumidification when humidity rises above setpoint.
4.4.3 Timer Control
- Clock Time (Timer 1) Set: Factory set to 12:00. Saved every 15 minutes. Set parameters L0 and L1 to revise.
- Timer 1 Output R5 Control: Controls R5 output based on L2-L3 (energized) and L4-L5 (de-energized) settings for a 24-hour period.
- Timer 2 Output R1 Control: Controls R1 output based on F0-F1 (start time) and F3 (de-energized time) / F5 (energized time) for repeated cycles.
5. Maintenance
To ensure optimal performance and longevity of your ZL-7863A controller, please observe the following:
- Environment: Avoid installing the device in humid environments, areas with corrosive gases, or strong electromagnetic fields, as these conditions can lead to abnormal operation or damage.
- Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Sensor Care: Ensure sensors are kept clean and free from obstructions to maintain accuracy.
6. Troubleshooting
6.1 Over Limit Warning
- If room temperature ≥ t5 and t5 > setpoint (L6 or L8), the display will show "tHi" alternately with the room temperature.
- If room temperature ≤ t6 and t6 < setpoint (L6 or L8), the display will show "tLo" alternately with the room temperature.
- If room humidity ≥ h3 and h3 > setpoint (L7 or L9), the display will show "HH" alternately with the room humidity.
- If room humidity ≤ h4 and h4 < setpoint (L7 or L9), the display will show "HL" alternately with the room humidity.
6.2 Sensor Failure
- If the temperature sensor fails, outputs R6, R7, and R2 will de-energize, and the display will blink "Et".
- If the humidity sensor fails, outputs R3 and R4 will de-energize, and the display will blink "Eh".
6.3 Restore to Factory Settings
To restore all parameters to their factory default values:
- Keep S and ▼ depressed simultaneously for 3 seconds. The display will show "UnL".
- Then press ن twice. All parameters will be restored to factory set values.
7. User Tips
- Initial Setup: Always double-check your wiring against the diagrams before powering on the device to prevent damage.
- Sensor Placement: Position the temperature and humidity sensors in a location that accurately represents the climate you wish to control, away from direct heat sources or drafts.
- Parameter Adjustment: When adjusting parameters, make small changes and observe the system's response before making further adjustments. This helps in fine-tuning the control for your specific application.
- Power Outages: The device is designed to restart after power supply comes back, retaining its last settings. However, it's good practice to periodically verify settings after any power interruptions.
8. Warranty and Support
The ZL-7863A controller comes with a one-year warranty from the date of purchase. This warranty is limited to defects in the product itself. Damage caused by improper usage, incorrect installation, or environmental factors (e.g., humid environment, corrosive gases, strong electromagnetic fields) is not covered by the warranty.
For detailed technical specifications, advanced programming, and further support, please refer to the official PDF manual: