1. Introduction
The TTNergy MPS-V Plus is a multi-function inverter/charger, combining the capabilities of an inverter, solar charger, and battery charger into a single unit. It is designed to provide uninterruptible power support with a portable form factor. This hybrid inverter is ideal for various applications, offering user-configurable settings and easy operation via its comprehensive LCD display.
Hybrid inverters are crucial for systems requiring energy storage, converting DC power from solar arrays into usable AC power and managing battery charging. They are particularly beneficial in regions with unstable grids or where grid electricity is unavailable.
Key Features:
- High efficiency pure sine wave inverter (Power Factor = 1)
- Wide PV input range (120VDC-500VDC)
- Integrated 100A MPPT Solar Charge Controller (SCC)
- Intelligent functionality for prioritizing utility and solar input
- Wide utility input range (90Vac-280Vac) for unreliable grid conditions
- Field serviceable design with replacement boards and spare parts
- Communication interfaces: RS232/RS485 for monitoring and troubleshooting
- Compatible with various battery types, including lithium batteries
- Optional anti-dust kit for harsh environments
- Optional WiFi Monitoring Function
2. Safety Information
WARNING: Before installation or use, please read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly sized and properly connected.
- Do not disassemble the unit. There are no user-serviceable parts inside.
- Avoid exposure to rain, snow, spray, or any liquids.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (PV, utility, battery) before performing any maintenance or wiring.
- This inverter is designed for indoor use in a controlled environment.
3. Package Contents
Upon unpacking, please verify that all items listed below are included and undamaged:
- TTNergy MPS-V Plus Inverter Unit x 1
- User Manual x 1
- Communication Cable x 1
- Software CD x 1
- DC Fuse x 1
- Ring Terminal x 1
- Strain Relief Plate x 1
- PV Wire Cover x 1
- Screws x 4

Figure 3.1: Typical package contents
4. Product Overview
The TTNergy MPS-V Plus inverter features a robust design with a durable metal casing and efficient cooling. Below are diagrams illustrating the main components and their functions.

Figure 4.1: Product Overview and Component Identification
Component Descriptions:
- LCD display: Shows system status and settings.
- Status indicator: LED indicating operational status.
- Charging indicator: LED indicating battery charging status.
- Fault indicator: LED indicating system faults.
- Function buttons: For navigating menus and adjusting settings.
- Power on/off switch: Main power control.
- AC input: Connection for utility grid power.
- AC output: Connection for household appliances.
- PV input: Connection for solar panel array.
- Battery input: Connection for battery bank.
- Circuit breaker: Overcurrent protection.
- Parallel communication port: For connecting multiple inverters in parallel (if supported by model).
- RS-232 communication port: For PC monitoring and communication.

Figure 4.2: Inverter Dimensions (Approx. 100*300*440mm)

Figure 4.3: Inverter Construction Details
5. Specifications
Below are the detailed technical specifications for the TTNergy MPS-V Plus Hybrid Solar Inverter models.
| Feature | TTN-MPS-V PLUS 3.5kW | TTN-MPS-V PLUS 5.5KW |
|---|---|---|
| Rated Power | 3500VA/3500W | 5500VA/5500W |
| Input | ||
| Voltage | 230VAC | |
| Selectable Voltage Range | 170~280VAC (For Personal Computers); 90~280VAC (For Home Appliances) | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| Output | ||
| AC Voltage Regulation (Batt.Mode) | 230VAC±5% | |
| Surge Power | 7000VA | 11000VA |
| Efficiency (Peak) PV to INV | 97% | |
| Efficiency (Peak) Battery to INV | 94% | |
| Transfer Time | 10ms (For Personal Computers); 20ms (For Home Appliances) | |
| Battery & AC Charger | ||
| Battery Voltage | 24VDC | 48VDC |
| Floating Charge Voltage | 27VDC | 54VDC |
| Overcharge Protection | 33VDC | 63VDC |
| Maximum Charge Current | 80A | |
| Solar Charger | ||
| Maximum PV Array Power | 5000W | 6000W |
| MPPT Range @ Operating Voltage | 120~450VDC | |
| Maximum PV Array Open Circuit Voltage | 500VDC | |
| Maximum Charging Current | 100A | |
| Maximum Efficiency | 98% | |
| Physical | ||
| Dimension, D*W*H (mm) | 100*300*440 | |
| Net Weight (kgs) | 11 | 12 |
| Communication Interface | USB/RS232/GPRS/WIFI | |
| Operating Environment | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Operating Temperature | 0℃~55℃ | |
| Storage Temperature | -15℃~60℃ | |
6. Installation
System Connection Diagrams:
The following diagrams illustrate basic application scenarios for the inverter/charger. Consult with your system integrator for specific system architectures based on your requirements.

Figure 6.1: Hybrid Power System Connection Scenarios
Important Installation Notes:
- This is a wide voltage Hybrid inverter. For normal operation, the voltage from the solar panel array must be above 150VDC to initiate the inverter.
- Properly match the battery capacity to your load requirements and application scenarios to avoid insufficient capacity or wasted power generation. Refer to the manual recommendations or consult a professional.
- Ensure all connections (PV, battery, AC input/output) are secure and correctly polarized.
- The inverter supports an optional WiFi function for monitoring.

Figure 6.2: Optional WiFi Plug Connection
7. Operation
The inverter features a comprehensive LCD display and function buttons for user-configurable settings and monitoring.

Figure 7.1: LCD Display and Function Keys
Basic Operation:
- Power On/Off: Use the main power switch (Component 6 in Figure 4.1) to turn the inverter on or off.
- LCD Display: Provides real-time information on input/output voltage, current, frequency, battery status, and operational mode.
- Function Buttons: Use the 'ENTER', 'UP', 'DOWN', and 'ESC' buttons to navigate through menus and adjust settings such as battery charging current, AC/solar charger priority, and acceptable input voltage range.
- MPPT Function: The integrated MPPT (Maximum Power Point Tracking) solar charge controller ensures maximum power extraction from your solar panels, achieving up to 98% efficiency.

Figure 7.2: Precision MPPT Function and Pure Sine Wave Output
Applications:
The TTNergy MPS-V Plus inverter provides reliable power for a wide range of home and office appliances, including motor-type loads.

Figure 7.3: Typical Appliance Applications
8. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure cooling vents are free from dust and debris. An optional anti-dust kit is available for harsh environments.
- Connection Checks: Regularly inspect all wiring connections (PV, battery, AC) to ensure they are tight and free from corrosion.
- Environmental Conditions: Ensure the inverter operates within the specified temperature and humidity ranges. Avoid direct sunlight and ensure proper airflow.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to improve performance or add new features.
9. Troubleshooting
The inverter is equipped with several protection features to ensure safe operation. If a fault occurs, the fault indicator LED (Component 4 in Figure 4.1) will illuminate, and an error code may be displayed on the LCD.
Common Protections:
- Short Circuit Protection: Automatically shuts down the inverter if a short circuit is detected on the output.
- Over Temperature Protection: Reduces output or shuts down if the internal temperature exceeds safe limits. Ensure proper ventilation.
- Over-Voltage Protection: Protects the inverter from excessive input voltage.

Figure 9.1: Built-in Protection Features
General Troubleshooting Steps:
- No Power: Check all power connections (battery, PV, AC input). Ensure the power switch is ON. Verify battery voltage is within acceptable range.
- No Output: Check for fault indicators on the LCD. Ensure the load is not exceeding the inverter's rated power or surge power.
- Overload Warning: Reduce the connected load. The inverter may temporarily shut down to protect itself.
- High PV Input Voltage: Ensure your solar panel array's open circuit voltage does not exceed 500VDC.
- Communication Issues: Verify the communication cable connection and ensure the correct software/drivers are installed on your monitoring device.
For persistent issues or error codes not listed, please refer to the detailed troubleshooting section in the full user manual (if available as a PDF) or contact technical support.
10. User Tips
- Battery Sizing: Always ensure your battery bank is adequately sized for your expected load and desired backup time. Undersized batteries can lead to frequent cycling and reduced lifespan.
- PV Array Voltage: Remember that the inverter requires a minimum PV input voltage of 150VDC to start operating from solar power. Design your solar array accordingly.
- Monitoring: Utilize the communication interfaces (USB/RS232/GPRS/WIFI) to monitor your system's performance, battery status, and energy production. This helps in optimizing settings and identifying potential issues early.
- Ventilation: Ensure the inverter is installed in a location with ample airflow to prevent overheating, especially during peak operation.
11. Warranty & Support
The TTNergy MPS-V Plus Hybrid Solar Inverter comes with a 2-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions.
For technical support, warranty claims, or service inquiries, please contact your original point of purchase or the TTNergy customer service department. Ensure you have your product model and serial number ready when contacting support.
12. Certifications
This product complies with relevant international safety and quality standards.

Figure 12.1: Product Certifications (e.g., CE)