1. Introduction
The RIDEN RD6018P is a high-performance DC-DC voltage step-down power supply module designed for precise voltage and current regulation. It features a 5-digit resolution display, high current output up to 18A, and a two-stage buck design for stable and efficient operation. This manual provides detailed instructions for the safe and effective use of your RD6018P power supply module, including setup, operation, and troubleshooting.
2. Safety Instructions
- Always ensure the input voltage is within the specified range (7-70.000V) to prevent damage to the device.
- The device features input over-voltage protection (triggers at >72V, cuts off at >75V) and input reverse connection protection (will not work, but will not damage up to -50V).
- Do not connect non-original accessories to the temperature sensor, fan, or communication interface on the board to avoid burning the device.
- Ensure proper ventilation during operation to prevent overheating. The device has over-temperature protection (system temperature >90°C).
- Exercise caution when handling electrical components. Always disconnect power before making or changing connections.
- The output terminals are short-circuit protected and will not be damaged by accidental short circuits.
3. Package Contents
The standard package for the RD6018P module includes:
- RD6018P Power Supply Module
- Packing Box
- 1808 25A Fuse
- External Temperature Sensor
- WiFi Board (included only with RD6018P-W model)
Note:
- The RD6018P does not include a case, power source (PSU), or cables. These must be purchased separately to assemble a complete power supply unit.
- A CR1220 clock battery is required for the clock function and must be prepared by the user.

4. Product Features
- 5-Digit Resolution: Provides highly accurate measurements with 0.001V voltage resolution and 0.001A current resolution, comparable to professional equipment.
- High Current Output: Capable of delivering up to 60V, 18A, and 1080W, meeting demands for high current power supply applications.
- Two-stage Buck Design: Combines Switch Buck and Linear Buck designs for high efficiency (>95%) and low ripple (<10mV), ensuring stable performance.
- Multiple Protection Mechanisms: Includes Over Voltage Protection (OVP), Over Current Protection (OCP), and Over Temperature Protection (OTP) to safeguard connected devices and the power supply itself.
- PC Software Control: Monitor and control the power supply from a computer running Windows 7 or above, offering a friendly interface and powerful functions for programming output.
- Mobile APP Control: (Android only) Control and monitor the device via Bluetooth using a dedicated mobile application.
- Firmware Updatable: Allows for firmware upgrades to optimize product experience and ensure continuous improvements.
- No Output Overshoot: Designed to produce a smooth output curve without interference or damage to the load caused by overshoot.
- Customizable Display: Offers Classic, Detailed, and Curve display styles, along with 15 customizable color options for the interface.



5. Specifications
RD6018P Module Specifications:
| Parameter | Value |
|---|---|
| Model | RD6018P / RD6018PW |
| Screen | 2.4 inch color HD display |
| Screen brightness setting | 0-5 (6 levels in total) |
| Input voltage range | 7-70.000V |
| Output voltage range | 0-60.000V |
| Output current range | 0-18.000A |
| Output power range | 0-1080W |
| Output voltage resolution | 1mV |
| Output current resolution | 1mA |
| Output voltage accuracy | 0.05% + 4mV |
| Output current accuracy | 0.1% + 6mA |
| Default cutoff current (charging) | 10mA |
| Output ripple typical | 20mV VPP |
| Working temperature range | -10℃~40℃ |
| External sensor Temp. detection range | -10℃~100℃ / 0℉~200℉ |
| External sensor Temp. detection accuracy | ±3℃ / ±6℉ |
| Constant voltage mode response time | 22uS (0.5A-18A) |
| Constant voltage mode load regulation | ±(0.1% + 0.2mV) |
| Constant current mode load regulation | 0.1% + 3mA |
| Capacity measurement range | 0-9999.99Ah |
| Energy measurement range | 0-9999.99Wh |
| Capacity and energy statistical error | ±2% |
| Buck working mode | (input voltage÷1.1)-1 |
| Over temperature protection | System temperature >90℃ |
| Weight (with package) | About 0.74kg |
| Product dimension | 167*81*67mm |
| Cooling fan start condition | Output current >6A or System temperature >45℃ |
| Cooling fan shut down condition | Output current <5.9A and System temperature <40℃ |
RD-1200W-68V PSU Specifications:

| Parameter | Value |
|---|---|
| Model | RD-1200W-68V |
| Input voltage (220V AC) | 200-240V AC |
| Output voltage (220V AC) | 68V |
| Output current (220V AC) | 17.7A |
| Output power (220V AC) | 1200W |
| Working temperature | -15℃~65℃ |
| Input voltage (110V AC) | 100-120V AC |
| Output voltage (110V AC) | 68V |
| Output current (110V AC) | 14.7A |
| Output power (110V AC) | 1000W |
| Product size | 242x125x65mm |
| Weight | 1.45kg |
Important Note on PSU Selection:
The 1200W PSU achieves 1200W output under 220V AC input, allowing the RD6018P to reach its full output capacity. However, under 110V AC input, the PSU's output is limited to 1000W, which means the RD6018P can only output a maximum of 950W. Please consider your mains voltage when selecting a PSU.
6. Setup and Installation
6.1. Assembly (with optional case and PSU)
If you are using an optional case (e.g., S800) and an external PSU, follow the instructions provided with those accessories for assembly. The RD6018P module is designed to integrate with compatible cases.
6.2. Connecting Input and Output
- Connect your DC input power source (e.g., the 1200W PSU) to the Input Positive and Input Negative terminals on the RD6018P module. Ensure correct polarity.
- Connect your load to the output terminals (red for positive, black for negative).

6.3. Installing Optional Components
- WiFi Board (RD6018P-W only): If you have the RD6018P-W model, install the WiFi board into the designated slot on the main circuit board.
- External Temperature Sensor: Connect the external temperature sensor to its dedicated socket for external temperature monitoring.
- Clock Battery: Insert a CR1220 clock battery into the Clock Battery Slot to enable the real-time clock function.
7. Operating Instructions
7.1. Basic Operation
- Power On/Off: Use the ON/OFF button on the front panel to power the device.
- Setting Voltage/Current: Use the rotary encoder and numerical keypad to set the desired output voltage and current limits. Refer to the on-screen prompts for guidance.
- Memory Functions (M1-M9): The device supports saving and recalling up to 9 sets of voltage and current parameters.
7.2. Display Styles
The RD6018P offers multiple display styles for different preferences:
- Classic Style: Standard display of voltage, current, and power.
- Detailed Style: Provides more detailed information about the power supply's status.
- Curve Style: Displays real-time voltage and current curves for visual analysis.
The system defaults to the classic style. Use the appropriate button (refer to the device interface) to switch between styles.

7.3. PC Software Control
The RD6018P can be monitored and controlled via PC software (supports Windows 7 and above). This software provides a comprehensive interface for advanced functions, including:
- Real-time data monitoring (voltage, current, power).
- Setting output parameters.
- Programming output sequences.
- Firmware updates.
Download and install the PC software from the official source. If you encounter compatibility issues, ensure you test the software before purchasing the product.


7.4. Mobile APP Control (Android Only)
For Android users, a mobile application is available for Bluetooth control and monitoring of the RD6018P. The iOS app is temporarily unavailable. Due to variations in mobile phones and operating systems, incompatibilities may occur. It is recommended to install and test the app before relying on this function.

7.5. Firmware Update
Firmware updates are available to optimize product performance. The device can be updated in normal mode. If normal mode update fails, you must enter Boot mode to upgrade the firmware. Refer to the PC software or official documentation for detailed firmware update procedures.

7.6. Customizing Display Colors
The RD6018P supports 15 customizable display colors. To enable this feature, ensure the color customization switch is turned on in the settings. You can then freely match and set your preferred colors for various display elements.

8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using abrasive cleaners or solvents.
- Fuse Replacement: The device uses an 1808 25A fuse. If the fuse blows, replace it with a fuse of the same type and rating. Ensure the device is disconnected from power before replacing the fuse.
- Firmware Updates: Regularly check for and install firmware updates to ensure optimal performance and access to new features.
- Storage: When not in use for extended periods, store the device in a cool, dry place away from direct sunlight and extreme temperatures.
9. Troubleshooting
- Device not powering on: Check input voltage connections and ensure the input voltage is within the 7-70V range. Verify the fuse is intact.
- "Overvoltage at Input" warning: This indicates the input voltage has exceeded 72V. The device will cut off output if the input voltage exceeds 75V. Reduce the input voltage to a safe level.
- No output: Check if the output is enabled. Verify that OVP, OCP, or OTP protections are not active (indicated on the display).
- PC Software/Mobile App not connecting: Ensure the correct communication method (USB/WiFi/Bluetooth) is selected and drivers are installed (for PC). Check for app compatibility with your specific phone model (for mobile app).
- Over Temperature Protection (OTP) active: The system temperature has exceeded 90°C. Ensure adequate ventilation and reduce the load if necessary. The cooling fan should activate if the output current is >6A or system temperature is >45℃.



10. User Tips
- For optimal performance, ensure your input power supply (PSU) is adequately rated for the desired output power, especially considering voltage drops at lower AC inputs (e.g., 110V AC).
- Utilize the memory functions (M1-M9) to quickly switch between frequently used voltage and current settings.
- The PC software offers advanced programming capabilities; explore these for automated testing or complex power profiles.
- Keep the firmware updated to benefit from the latest features and bug fixes.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.
12. Function Tests Video
Watch this video for a demonstration of the RD6018P's key functions and protection mechanisms:
Video demonstrating the features and function tests of the RD6018P power supply, including ripple test, input voltage test, battery reverse connection, and output short circuit test.