1. Introduction
The EVCO CPN1D1A2 Pressure Controller is a robust and versatile device designed for precise pressure management and control in various industrial and commercial applications. This manual provides essential information for the safe and effective installation, operation, and maintenance of your controller. Please read this manual thoroughly before installation and use.
2. Package Contents
Upon unpacking, please verify that all items listed below are present and undamaged:
- EVCO CPN1D1A2 Pressure Controller Unit
- Wiring Harness
- Terminal Block

3. Specifications
| Feature | Detail |
|---|---|
| Model | CPN1D1A2 (also compatible with CPN1D1A2C) |
| ID | 10269-1009-02 |
| Power Supply | 12 VAC/DC |
| Temperature Range | 0 to 85°C (32 to 131°F) |
| Relay Outputs (K1-K5) | 5A, 250V~ |
| Relay Output (K6) | Max 3A, 250V~ |
| Certification | CE |
| Origin | Mainland China |
4. Setup
4.1 Mounting
Secure the EVCO CPN1D1A2 controller in a suitable electrical enclosure. Ensure the mounting location provides adequate ventilation to prevent overheating and allows for easy access to wiring terminals.
4.2 Wiring
All wiring should be performed by a qualified technician and in accordance with local electrical codes. Refer to the detailed wiring diagram below for proper connections.

Wiring Terminal Descriptions:
- Power Supply (12 VAC/DC): Connect your 12 VAC or 12 VDC power source to the designated terminals. Observe correct polarity for DC power.
- Analog Inputs (AI1, AI2): Connect pressure sensors or other analog input devices to these terminals.
- Digital Inputs (DI1, DI2, DI3, DI4, DI5): Connect digital switches or signals to these terminals.
- Analog Output (AO1): Connect analog output devices as required by your system.
- Relay Outputs (K1-K6): These are potential-free contacts for controlling external loads.
- K1, K2, K3, K4, K5: Rated for 5A, 250V~
- K6: Rated for Max 3A, 250V~
- Remote Keyboard (12VDC, GND, DATA): For connecting an optional remote keyboard for configuration and control.
- Serial Port: For communication with other devices or systems.
Important: Ensure that the current draw of any connected load does not exceed the maximum rating of the respective relay output to prevent damage to the controller or connected equipment.
5. Operating Instructions
5.1 Initial Power-Up
Once all wiring is securely connected and verified, apply power to the controller. The unit should power on and display its default or last-saved settings.
5.2 Configuration
The EVCO CPN1D1A2 controller is highly configurable. Specific programming and parameter settings are typically performed via the unit's front panel interface (if available) or through a connected remote keyboard/software. Please refer to the dedicated programming manual or contact EVCO technical support for detailed instructions on configuring parameters such as setpoints, hysteresis, alarm thresholds, and input/output assignments.
5.3 Monitoring
After configuration, the controller will continuously monitor the connected pressure sensors and activate/deactivate its relay outputs based on the programmed logic. Monitor the display for current pressure readings and status indicators.
6. Maintenance
6.1 Cleaning
Keep the controller unit clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents, as these may damage the casing or display.
6.2 Inspection
Periodically inspect all wiring connections to ensure they are tight and free from corrosion or damage. Check for any signs of wear on cables or terminals. Address any issues promptly to ensure reliable operation.
6.3 Calibration
If you suspect inaccurate pressure readings, the controller or its connected sensors may require re-calibration. Consult advanced technical documentation or contact EVCO technical support for calibration procedures.
7. Troubleshooting
If you encounter issues with your EVCO CPN1D1A2 Pressure Controller, refer to the following common problems and solutions:
- No Power:
- Verify that the 12 VAC/DC power supply is correctly connected and providing the specified voltage.
- Check for loose connections or tripped circuit breakers.
- Incorrect Pressure Readings:
- Ensure pressure sensors are correctly wired to the analog input terminals (AI1, AI2).
- Check sensor specifications and ensure they are compatible with the controller.
- The sensor or controller may require calibration.
- Relay Output Not Activating:
- Verify the load connected to the relay output (K1-K6) is correctly wired.
- Check the controller's programming to ensure the setpoints and logic for relay activation are correct.
- Ensure the load current does not exceed the maximum rating of the relay (5A for K1-K5, 3A for K6).
- Communication Issues (Serial Port/Remote Keyboard):
- Check physical connections to the serial port or remote keyboard.
- Verify communication settings (e.g., baud rate, parity) are correctly configured on both the controller and the connected device.
8. User Tips
- Always perform a continuity check on your wiring before applying power to prevent short circuits or damage.
- Keep a record of your controller's configuration settings for quick restoration if needed.
- For optimal performance and longevity, ensure the controller operates within its specified temperature range and is protected from excessive moisture or vibration.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized EVCO distributor or the manufacturer directly. When contacting support, please provide the following information:
- Product Model: CPN1D1A2
- Product ID: 10269-1009-02
- Date of Purchase
- Detailed description of the issue