1. Introduction
This manual provides essential information for the safe and efficient operation of your TTNergy Off-Grid Solar Hybrid Inverter. This multi-function inverter/charger combines the capabilities of an inverter, solar charger, and battery charger to provide reliable, uninterruptible power support. It is designed for both on-grid and off-grid applications, converting DC power from solar arrays into usable AC power and storing excess energy in batteries.
The comprehensive LCD display allows for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges, making it adaptable to various applications and regional power conditions.
Video: Overview of the manufacturing process for TTNergy inverters, highlighting quality control and assembly.
2. Key Features
- Pure Sine Wave Inverter: Provides high-quality AC power suitable for sensitive electronics.
- Built-in PWM Solar Charge Controller: Efficiently manages charging from solar modules.
- Selectable Input Voltage Range: Adaptable to various home appliance or personal computer requirements.
- Configurable Charging Current: Allows adjustment based on battery type and capacity.
- AC/Solar Input Priority: User-configurable via LCD setting to optimize power source usage.
- Generator Compatibility: Can operate with mains voltage or generator power.
- Auto Restart: Automatically restarts when AC power recovers.
- Protection Features: Includes overload and short circuit protection.
- Smart Battery Charger Design: Optimizes battery performance and longevity.
- Cold Start Function: Enables starting the inverter without AC input.
- Parallel Operation: Up to 6 units available for 5KVA models (check specific model for compatibility).

Image: Visual representation of the inverter's main features.
3. Specifications
The following table details the specifications for the TTN-PS series, focusing on the 5KVA model (TTN-PS 5K) which aligns with the 4200W/5KW rating.
| Category | Parameter | TTN-PS 5K |
|---|---|---|
| General | Rated Power | 5000VA/4000W |
| Model NO. | TTN-PS 5K | |
| Input | Phase & Waveform | 230 VAC |
| Voltage Selectable Range (PC) | 170~280 VAC | |
| Voltage Selectable Range (Home Appliance) | 90~280 VAC | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| Output | AC Voltage Regulation (Batt. Mode) | 230V AC ± 5% |
| Surge Power | 10000VA | |
| Efficiency (Peak) | 93% | |
| Transfer Time | 10ms (PC), 20ms (Home Appliance) | |
| Wave Form | Pure sine wave | |
| Battery & AC Charger | Battery Voltage | 48VDC |
| Floating Charge Voltage | 54VDC | |
| Overcharge Protection | 60VDC | |
| Maximum Charge Current | 10A/20A/30A/40A/50A/60A | |
| PV Input | Charge Current | 50A |
| MPPT Range @ Operating Voltage (VDC) | 105VDC | |
| Standby Power Consumption | 2W | |
| Physical | Dimension, D×W×H (mm) | 413x295x120 |
| Net Weight (Kgs) | 9.8 | |
| Environmental | Humidity | 5%~95% Relative Humidity (Non-condensing) |
| Operation Temperature | 0℃~55℃ | |
| Storage Temperature | -15℃~60℃ |
4. Components and LCD Display Information
Familiarize yourself with the inverter's components and LCD display for proper operation and monitoring.

Image: Front and rear view of the inverter with labeled parts.
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC output
- AC input
- PV input
- Battery input
- Circuit breaker
- RS232 communication port
- Parallel communication cable (only for parallel model)
- Current sharing cable (only for parallel model)
- Dry contact
- USB communication port
5. Setup: Solar System Connection
Proper connection is crucial for the safe and efficient operation of your hybrid power system. Refer to the diagrams below for typical connection scenarios.
5.1 Hybrid Power System (Off-Grid/Tie)
This diagram illustrates a typical hybrid power system setup, integrating solar modules, a generator, utility grid, battery packs, and home appliances with the inverter.

Image: Diagram showing connections for solar modules, generator, utility grid, battery packs, and home appliances to the inverter.
5.2 Parallel Operation (4K/5K Models)
For increased power output and redundancy, multiple 4K/5K inverters can be operated in parallel. Ensure proper parallel communication and current sharing cable connections as shown.

Image: Wiring diagram for parallel operation of multiple 4K/5K inverters.
Important Note on Battery Capacity:
The correct matching of battery capacity to your system is critical. It must be determined based on the specific load requirements and application scenarios. Incorrect battery sizing can lead to insufficient power or inefficient energy generation. Always refer to the full product manual for detailed recommendations or consult with qualified technical support.
6. Operation
Once installed, the inverter can be operated and monitored via its LCD display and function buttons. Key operational aspects include:
- Power On/Off: Use the dedicated power switch (Component 6) to turn the unit on or off.
- LCD Display: Provides real-time information on system status, input/output voltages, battery charge, and fault codes.
- Function Buttons: Navigate through menus and adjust settings such as:
- Battery charging current (settable based on battery type).
- AC/Solar input priority (e.g., prioritize solar, then utility, then battery).
- Acceptable input voltage range (for compatibility with different grid conditions or generator outputs).
- Indicators: Monitor the Status, Charging, and Fault indicators (Components 2, 3, 4) for quick system status checks.
- Cold Start: The inverter supports cold start, allowing it to power on directly from batteries without an AC input.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and cooling. Use a dry cloth for cleaning the exterior.
- Connection Checks: Periodically inspect all wiring connections (solar, battery, AC input/output) to ensure they are secure and free from corrosion.
- Battery Health: Monitor battery voltage and performance through the LCD. Follow the battery manufacturer's guidelines for maintenance.
- Environmental Conditions: Ensure the inverter is operating within the specified temperature and humidity ranges to prevent damage.
- Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or add features.
8. Troubleshooting
If you encounter issues with your inverter, perform the following basic checks. For complex problems, consult the full product manual or contact technical support.
- No Power: Check all circuit breakers (Component 11) and ensure battery connections are secure and charged. Verify AC input if applicable.
- Fault Indicator On: Refer to the LCD display for specific fault codes. Common faults include overload, short circuit, or battery issues.
- Overload Protection: If an overload occurs, the inverter will shut down. Reduce the connected load and restart the inverter.
- No Solar Charging: Ensure solar modules are clean, properly connected to the PV input (Component 9), and receiving sufficient sunlight. Check the solar charge controller settings.
- Incorrect Output Voltage/Frequency: Verify that the input voltage range and frequency settings are correctly configured for your region via the LCD display.
9. User Tips
- Battery Sizing: Always ensure your battery bank capacity is correctly matched to your specific load requirements and application. An undersized battery bank can lead to frequent power interruptions, while an oversized one can be an unnecessary expense. Consult the full manual or a professional for guidance.
- Ventilation: Ensure the inverter is installed in a well-ventilated area to prevent overheating, which can reduce efficiency and lifespan.
- Regular Monitoring: Periodically check the LCD display for system status and performance metrics to catch potential issues early.
10. Support
For further assistance, technical support, or detailed inquiries not covered in this manual, please contact TTNergy customer service. Refer to the official product page or your purchase documentation for contact information.