SUMRY EP-4200H

Contents

SUMRY EP-4200H Dual Voltage Solar Inverter

Model: EP-4200H

Brand: SUMRY

1. About This Manual

1.1 Purpose

This manual introduces the assembly, installation, operation and troubleshooting of the SUMRY EP-4200H inverter. Please read this manual carefully before installation and operation.

1.2 Target Group

This manual is designed for professionals and end users. Operations that do not require any specific skills can also be handled by the end users themselves. Professionals must have the following skills:

  • Understand how the inverter works and operates
  • After training, someone knows how to deal with crises and risks in the installation and use of electrical equipment and devices
  • After training, someone knows how to install and commission electrical equipment and fixtures
  • Understand the applicable standards and directives
  • Understand and abide by this manual and all safety knowledge

1.3 Safety Regulations

⚠️ Warning: This article contains important safety and operation instructions. Please read and save this manual for future reference.

  1. Please choose the corresponding setting according to whether to use lead-acid battery or lithium battery. If it is not set properly, the system may not operate normally.
  2. Before using the unit, please read all the instructions and cautionary on the unit and understand all battery models and relevant chapters in this manual.
  3. Never short-circuit AC output and DC input. Never connect the mains when the DC input is short-circuited.
  4. Never charge a non-rechargeable battery.
  5. Do not disassemble the unit. When maintenance or repair is needed, please send it to the professional technical service center. Incorrect reassembly may lead to electric shock or fire.
  6. To reduce the risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning. Turning off the device will not reduce this risk.
  7. Be extra careful when using metal tools on or around the battery. Some potential risks, such as short circuit of batteries or other electronic components caused by sparks caused by falling tools, may lead to explosion.
  8. In order to realize the optimal operation of this off grid solar inverter, please select the appropriate cable size according to the instruction. It is very important to operate the off grid solar inverter correctly.
  9. When disconnecting AC or DC terminals, please strictly follow the installation procedure. For more details, please refer to "Installation" in this manual.
  10. Grounding instruction: this off grid solar inverter shall be connected to the permanent grounding wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  11. Provide a fuse that meets certain specifications for battery power supply as overcurrent protection.
  12. Warning!! Only professional service personnel can repair this equipment. If there are still errors after troubleshooting, please send this off line solar inverter back to the local dealer or service center for maintenance.

1.4 Features

  • Pure sine wave inverter
  • Programmable supply priority for PV, battery or Grid
  • High PV input voltage range (55~500VDC)
  • Built-in Max 100A MPPT solar charger
  • Compatible with lithium-ion battery and other battery types (GEL, AGM, User-defined, FLD)
  • Support BMS communication with Lithium battery
  • Smart battery charge design to optimize battery life
  • Overload, high temperature, inverter output short circuit protection
  • Cold start function
  • Intelligent fan speed adjustment
  • Built-in anti-dust kit for harsh environment (optional)
  • WIFI & GPRS available for iOS and Android (optional)
  • AC input compatible with mains and generator
  • Automatic restart function when mains power is restored
  • RS485 port used for communication with BMS
  • RGB lamp, which displays different colors according to inverter status (optional)

1.5 Basic System Architecture

The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:

  • Generator or mains electricity
  • Solar module (optional)

Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environment, including motor type appliances such as tube light, fan, refrigerator and air conditioner.

Figure 1 Hybrid Power System Diagram
Figure 1: Hybrid Power System Diagram showing connections between solar panels, generator, utility grid, battery, inverter, and home appliances.

1.6 Product Overview

The operation and display panel is located on the front panel of the inverter. It includes four function keys and an LCD screen for indicating operation status and input/output power information. The rear panel provides various connection ports.

System Diagram with numbered components
System Diagram: Detailed view of the inverter's front panel display and rear panel connections.

Key Components:

  1. LCD screen
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function keys (ESC, UP, DOWN, ENTER)
  6. Power on/off switch
  7. AC input terminal
  8. AC output terminal
  9. PV input terminal
  10. Battery input terminal
  11. Circuit breaker
  12. Ground wire terminal
  13. BMS communication port
  14. RS232 communication port

2. Installation

2.1 Unpacking And Inspection

Unpack the inverter and make sure there are no damaged objects in the package. You should have received the following items inside of package:

2.2 Preparation Before Installation

Before connecting all wirings, please take off the bottom cover by removing two screws.

2.3 Inverter Installation

Please consider the following points before installing the equipment:

  1. Do not install the inverter on flammable building materials.
  2. Install on a solid surface.
  3. Install this inverter at eye level in order to allow the LCD display to be read at all times.
  4. Leave a gap of 20-50 cm for ventilation and heat dissipation of the equipment.
  5. The equipment working environment temperature should be 0-55°C.
  6. It is best to install it vertically down against the wall, leaving a certain space with the ground.

⚠️ SUITABLE FOR INSTALLATION ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY

Tighten the screws and fix the installation. Machine fixing screws: M4 or M5 screws are recommended.

Inverter installation dimensions
Inverter Installation: Side view with recommended clearance dimensions (20cm sides, 50cm top/bottom).

2.4 Battery Connection

2.4.1 Lead-Acid Battery Connection

⚠️ WARNING: In order to operate safely and comply with laws and regulations, it is required to install an independent DC overcurrent protector or disconnect device between the battery and the inverter.

⚠️ WARNING: All wiring must be performed by qualified personnel.

⚠️ WARNING: It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and as below.

Recommended battery cable specifications:

ModelWire specificationTorque value
12V1 * 2/0 AWG (67mm²)2-3 Nm
24V1 * 1/0 AWG (54mm²)2-3 Nm

! Note: The recommended charging current of lead-acid battery is 0.2C (C is battery capacity).

Please follow below steps to implement battery connection:

  1. Connect the battery according to the recommended battery cable specifications.
  2. Connect all battery packs as needed.
  3. Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and tighten the ring terminal with the battery terminal.

⚠️ WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.

⚠️ CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal, otherwise, it may cause short circuit or overheating.

⚠️ CAUTION!! Do not apply antioxidant to the terminal before it is tightly connected.

⚠️ CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative(-).

4. Connect all battery packs as shown in the diagram:

12V and 24V battery connection diagrams
Battery Connection Diagrams: Illustrates how to connect 12V and 24V battery models.

2.4.2 Lithium Battery Connection

If choosing a lithium battery for the inverter, only lithium batteries that have been matched with BMS communication protocol are allowed.

  1. Connect the battery according to the recommended battery cable specifications.
  2. Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and that the ring terminal is tightened with the battery terminal.
  3. Connect one side of the RJ45 cable to the BMS communication port of the inverter.
  4. Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.

Note: If you choose a lithium battery, please make sure to connect the battery and inverter with BMS communication cable, and select the battery type as "LIB" mode.

Communication And Setting Of Lithium Battery

1. Connect the RJ45 communication cable between inverter and battery. Please confirm that the lithium battery BMS port's PIN is correspond with the inverter BMS communication port. The inverter BMS port's PIN definition as below:

Pin numberPort definitions
1RS485B
2RS485A
3NG
4NG
5NG
6NG
7RS485A
8RS485B
RJ45 communication port pinout
RJ45 Communication Port Pinout: Diagram showing the pin assignments for the BMS communication port.

2. In order to communicate with the lithium battery BMS, you should press the "ENTER" button for a long time, and set the battery type as "LIB" in program 05. Then select the matching battery protocol in Program 10.

2.5 AC Input/Output Connection

⚠️ CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input.

⚠️ CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.

⚠️ WARNING!! All wiring must be performed by qualified personnel.

⚠️ WARNING!! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.

Suitable cable specifications for AC wires:

ModelWire GaugeTorque Value
12V/24V1 * 12 AWG1.2-1.6 Nm

Please follow below steps to implement AC input/output connection:

  1. Before making AC input/output connection, be sure to open DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
  3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
  • Ground (yellow-green)
  • L → LINE (brown or black)
  • N → Neutral (blue)

⚠️ WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.

4. Then, insert the AC output conductor according to the polarity identification at the terminal, and tighten the screw.

  • L → LINE (brown or black)
  • N → Neutral (blue)

5. Make sure the wires are firmly connected.

⚠️ CAUTION: Please ensure that all AC cables are connected correctly according to the corresponding polarity.

⚠️ CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.

AC Input/Output Wiring Diagram
AC Input/Output Wiring Diagram: Illustrates the connection of AC input from generator/mains and AC output to home appliances, including circuit breakers.

2.6 PV Connection

⚠️ CAUTION: Before connecting the PV module, please install separately a DC circuit breaker between the inverter and PV module.

⚠️ WARNING!! All wiring must be performed by qualified personnel.

⚠️ WARNING!! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

Recommended PV cable specifications:

ModelWire GaugeTorque Value
12V/24V1 * 16 AWG1.2-1.6 Nm

2.6.1 PV Module Selection

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than min battery voltage.
ParameterValue
Max. PV Array Power4000W
I Max. PV18A
Nominal PV Voltage240V
PV Array MPPT Voltage Range55V-500V
Max. PV Array Open Circuit Voltage500V

Take 250Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed as below table:

Solar panel parameters -250WpSolar Input Range (Min in serial: 6 pcs, max in serial: 11 pcs)Q'ty of panelsTotal Input
-Vmp: 30.1Vdc3 pcs in serial3750W
-Imp: 8.3A6 pcs in serial61500W
-Voc: 37.7Vdc8 pcs in serial82000W
-Isc: 8.4A12 pcs in serial123000W
-Cells: 6013 pcs in serial133250W
8 pcs in serial and 2 sets in paralleled164000W

2.6.2 PV Module Connection Steps

Please follow below steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
  3. Make sure the wires are securely connected.
Solar panel series and parallel wiring methods
Solar Photovoltaic Panel Wiring Method: Diagrams illustrating series and parallel connections for solar panels, including voltage and current calculations.

2.7 Final Assembly

After connecting all the wires, put the bottom cover back and screw the screws.

Product appearance from different angles
Product Appearance: Four views of the inverter, showing front, top, rear, and side panels.

3. Operation

3.1 Power On/Off

After installing the machine correctly and connecting the battery correctly, just press the On/Off switch to turn on the machine.

3.2 Operation And Display

The operation and display panel is shown in the product overview section. It includes four function keys and an LCD screen for indicating operation status and input/output power information.

3.2.1 RGB Light (optional)

  • Inverter state: green light
  • Utility state: blue light
  • Failure state: red light

3.2.2 LED Indicator

LED IndicatorMessages
AC / INV Green (Solid On)Output is powered by utility in Line mode.
CHG Green (Flashing)Output is powered by battery or PV in battery mode.
CHG Green (Solid On)Battery is fully charged.
CHG Green (Flashing)Battery is charging.
FAULT Red (Solid On)Fault occurs in the inverter.
FAULT Red (Flashing)Warning condition occurs in the inverter.

3.2.3 Function Keys

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

3.2.4 LCD Display Icons

The LCD display shows various information including input source, configuration, fault, output, and battery information. Refer to the manual for detailed icon descriptions.

3.2.5 LCD Setting

After pressing and holding the “ENTER” button for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press “ENTER” button to confirm the selection or "ESC" button to exit.

Available settings include Output source priority (SUB, SBU, MKS), Maximum charging current, AC input voltage range (APL, UPS), Power saving mode enable/disable, Battery type (AGM, Flooded, User Defined, LIB), Auto restart functions, Output voltage, Output frequency, Lithium battery protocol (PYLON, PACE), Setting voltage point back to utility charging, Low DC cut-off voltage, Battery equalization settings, Backlight control, Beeps while primary source is interrupted, Overload bypass, Record fault code, and RGB lighting.

3.2.6 Display Setting

The LCD display information can be switched in turns by pressing "UP" or "DOWN" key. The selectable information includes input voltage, input frequency, PV voltage, MPPT charging current, MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in Watt, DC discharging current, main CPU Version and second CPU Version.

3.2.7 Operating Mode Description

The inverter supports various operating modes:

  • Standby mode / Power saving mode: No output is supplied by the unit but it can still charge batteries.
  • Line Mode: The unit will provide output power from the mains. It will also charge the battery at line mode.
  • Battery Mode: The unit will provide output power from battery and solar power.

4. Maintenance

4.1 Clearance and Maintenance for Anti-Dust Kit (Optional)

Every inverter is already installed with an anti-dust kit from the factory. The inverter will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust from your inverter and increases product reliability in harsh environments.

Steps for Clearance and Maintenance:

Step 1: Please remove screws as shown below.

Removing bottom cover of inverter
Removing Bottom Cover: Illustration of how to remove the bottom cover to access internal components.

Step 2: Then, remove the air filter as shown below.

Removing air filter from inverter
Removing Air Filter: Diagram showing the location and method for removing the air filter.

Step 3: Clean the air filter. After cleaning, reinstall the dust removal net to the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

5. Specifications

5.1 Table 1: Specification of LINE Mode

INVERTER MODELEP-4200H
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS)
90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS);
100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionBattery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS);
20ms typical (Appliances)

5.2 Table 2: Specification of Inverter Mode

INVERTER MODELEP-4200H
Rated Output PowerDC12V-2300VA/2300W
DC24V-4200KA/4200W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency60Hz or 50Hz
Peak Efficiency94%
Overload Protection5s@≥150% load; 10s@105%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage12 Vdc
24Vdc
Cold Start Voltage11.5 Vdc
23.0Vdc
Low DC Warning Voltage (@Load < 20%)11.0 Vdc
22.0Vdc
Low DC Warning Voltage (@20% ≤ Load < 50%)10.7 Vdc
21.4Vdc
Low DC Warning Voltage (@Load ≥ 50%)10.1 Vdc
20.2Vdc
Low DC Warning Return Voltage (@Load < 20%)11.5 Vdc
23.0Vdc
Low DC Warning Return Voltage (@20% ≤ Load < 50%)11.2 Vdc
22.4Vdc
Low DC Warning Return Voltage (@Load ≥ 50%)10.6 Vdc
21.2Vdc
Low DC Cut-off Voltage (@Load < 20%)10.5 Vdc
21.0Vdc
Low DC Cut-off Voltage (@20% ≤ Load < 50%)10.2 Vdc
20.4Vdc
Low DC Cut-off Voltage (@Load ≥ 50%)9.6 Vdc
19.2Vdc
High DC Cut-off Voltage16 Vdc
32Vdc
No Load Power Consumption20W
30W
Saving Mode Power Consumption<10W
<15W

5.3 Table 3: Specification of Charging Mode

Utility Charging Mode
Battery Model12V
24V
Charging Current (UPS) @Nominal Input Voltage100A
Bulk Charging (Flooded Battery)14.6
29.2
Voltage (AGM / Gel Battery)14.1
28.2
Floating Charging Voltage13.5Vdc
27Vdc
Charging Algorithm3-Step
Solar Charging Mode
Max. PV Array Power4000W
I Max. PV18A
Nominal PV Voltage240V
PV Array MPPT Voltage Range55V-500V
Max. PV Array Open Circuit Voltage500V
Max Charging Current100A

5.4 Table 4: General Specifications

ParameterValue
Operating Temperature Range-20°C to 55°C
Storage temperature-20°C~60°C
Dimension (D*W*H), mm405*305*108
Net Weight, kg6.7

6. Troubleshooting

This section provides guidance for common problems, their possible causes, and recommended solutions.

ProblemLCD/BuzzerExplanation / Possible causeWhat to do
Unit shuts down automatically during startup process.LCD and buzzer will be active for 3 seconds and then complete off.Battery voltage is too low1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low.
2. Battery polarity is connected reversed.
1. Check if batteries and the wiring are connected well.
2. Re-charge battery.
3. Replace battery.
Input voltage is displayed as 0 on the LCDInput protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but the unit works in battery mode.The power-on icon of LCD flashes, and the status indicator icon flashes.Insufficient quality of AC power. (Shore or Generator)1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS → Appliance)
Fault code 07Overload error. The inverter is overload 110% and time is up.Reduce the connected load by switching off some equipment.
Fault code 05Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 02Internal temperature of inverter component are over heated.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Buzzer beeps continuously and the status indicator icon is always on.Fault code 03Battery is over-charged. The battery voltage is too high.Return to repair center. Check if spec and quantity of batteries are meet requirements.
Fault code 01Fan faultReplace the fan
Fault code 06/58Output abnormal1. Reduce the connected load.
2. Return to repair center
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit, if the error happens again, please return to repair center.
Fault code 52Bus voltage is too low.
Fault code 55Output voltage is unbalanced.

6.1 Warning Codes

Warning CodeWarning EventAutomatic AlarmIcon flashing
01Fan is locked when inverter is on.Beep three times every second
03Battery overchargeBeep once every second
04Battery low voltageBeep once every second
07OverloadBeep once every 0.5 second
10Output power is deratingBeep twice every 3 seconds
15PV energy is weakNo Beep
EQBattery equalizationNo Beep

7. User Tips

  • The inverter is designed to work with both 12V and 24V battery systems, offering flexibility for different setups.
  • For 3kW/3.8kW models, use a 24V battery. For the 6.2kW model, a 48V battery is required. Ensure the correct battery voltage is used for your specific inverter model.
  • When connecting solar panels, carefully consider the PV charging power and voltage range of your inverter (e.g., 3kW model: 3000W, 55-450V; 3.8/6.2kW models: 6000W, 55-450V). Always check the voltage and open circuit voltage of your individual solar panels to determine the optimal series/parallel configuration.
  • The EP series machines have a single communication port (COMM port). You can choose to communicate via a WiFi module or the battery BMS, but only one method can be active at a time. If you plan to use WiFi monitoring, ensure you purchase the WiFi module.
  • Always install appropriate circuit breakers between the battery and inverter, PV input and inverter, and AC input/output to ensure safety and proper operation. Refer to the 'Circuit Breaker Specification' in the installation section for recommended ratings based on your inverter's power.

8. Warranty Information

Please refer to the product packaging or contact your retailer for specific warranty terms and conditions. Keep your purchase receipt as proof of purchase for any warranty claims.

9. Technical Support

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact the SUMRY Overseas flagship Store or your local dealer. Provide your product model number (EP-4200H) and a detailed description of the issue for efficient support.

Documents and downloads