Heng Long TH17018-SMT4

Contents

Heng Long 1/16 RC Tank Open Fire Smoke Flash Parts Instruction Manual

Model: TH17018-SMT4 (CS-SMOKEFLASH-TK16)

Important Safety Information

⚠ DANGER

  • Keep this product away from flammable materials and open flames.
  • The battery and electronic components are a potential fire hazard if damaged or misused.

⚠ CAUTION

  • Avoid looking directly into the infrared/laser aiming beam, as it may cause eye irritation or damage.
  • Read these instructions carefully before use and retain them for future reference.
  • Do not expose the tank to high temperatures, direct sunlight, or humid environments; this product is intended to be used in dry areas only.
  • The hull and motor may become hot during prolonged use. Do not touch hot surfaces to avoid burns.
  • Do not operate the tank near water, swimming pools, or other liquid environments.

Choking Hazard Warning

This product contains small parts and is not suitable for children under 3 years of age. Keep away from young children to prevent choking.

Product Overview

This product provides "Open Fire Smoke Flash" functionality for 1/16 scale RC Tank models equipped with a TK16 MainBoard. It includes a smoke generator pump assembly and a control board to simulate realistic smoke and muzzle flash effects.

Heng Long Open Fire Smoke Flash Parts
Figure 1: Overview of the Heng Long Open Fire Smoke Flash Parts, showing the pump, control board, and connecting tubes/wires.

Package Contents

The package includes the following components:

  • 1 Set Open Fire Smoke Flash Part (includes pump assembly, control board, and necessary wiring/tubing).

Setup and Installation

Follow these steps to install the Open Fire Smoke Flash Parts into your RC Tank model with a TK16 MainBoard.

  1. Prepare Power:
    • Fully charge the tank's main battery and the remote control's batteries according to their respective charging instructions.
    • Install the charged main battery into the tank's battery compartment and secure the cover.
    • Insert batteries into the remote control and ensure its power switch is in the "OFF" position before proceeding.
  2. Identify Components:

    Familiarize yourself with the smoke/flash control board and pump assembly.

    Control Board Front View
    Figure 2: Front view of the control board, showing dip switches (labeled ON, 1, 2) and various connection ports.
    Control Board Angled View
    Figure 3: Angled view of the control board, illustrating the wiring harness connected to the board.
    Control Board Top View
    Figure 4: Top view of the control board, providing a clear layout of the potentiometers (labeled 102, 104) and connectors.
  3. Connect the Smoke/Flash Unit:
    • Connect the pump assembly to the designated port on the smoke/flash control board. Ensure the tubing is securely attached to the pump and routed to the smoke exhaust port of your tank.
    • Connect the control board's main wiring harness to the appropriate port on your RC Tank's TK16 MainBoard. Refer to your TK16 MainBoard manual for specific connection points for auxiliary functions or smoke/flash units.
    • If a separate flash unit is included (not explicitly shown but implied by "flash parts"), connect it to the corresponding port on the control board.
  4. Secure Components:

    Mount the smoke/flash control board and pump assembly securely within the tank chassis, ensuring they do not interfere with moving parts or other electronics. Use appropriate fasteners or adhesive if necessary.

  5. Fill Smoke Fluid (if applicable):

    If your smoke unit requires fluid, carefully fill the smoke fluid reservoir according to the instructions provided with your smoke fluid. Do not overfill.

Operation

  1. Power On Sequence:
    • Ensure all connections are secure and the remote control's power switch is OFF.
    • Turn ON the power switch on your RC Tank.
    • Turn ON the power switch on your remote control.
  2. Activating Smoke/Flash:
    • The smoke and flash functions are typically controlled via specific channels or buttons on your RC Tank's remote control, as configured with the TK16 MainBoard.
    • Consult your RC Tank's main manual or TK16 MainBoard documentation for details on how to activate these features.
    • The dip switches (labeled ON, 1, 2) and potentiometers (labeled 102, 104) on the control board (Figures 2, 4) may be used for fine-tuning smoke output, flash timing, or other parameters. Adjust these carefully and test the effects.
  3. Power Off Sequence:
    • After use, power off the remote control first.
    • Then, turn off the power switch on the RC Tank.

Maintenance

  • Cleaning:
    • Use a dry, soft cloth to wipe the exterior of the smoke/flash unit and the tank.
    • Do not use water, solvents, or abrasive cleaners, as these can damage electronic components or finishes.
  • Inspection:
    • Regularly inspect all wiring and tubing for secure connections and signs of wear or damage.
    • If your tank has tracks and wheels, inspect them regularly for debris and remove any dirt or obstructions to ensure smooth movement.
  • Smoke Fluid Management:
    • Check smoke fluid levels before each use. Refill as needed with compatible smoke fluid.
    • Periodically clean the smoke exhaust nozzle to prevent blockages.
  • Storage:
    • Store the tank and remote control in a cool, dry place when not in use.
    • Keep away from children and pets.

Troubleshooting

Problem Possible Cause Solution
Smoke/Flash unit not responding
  • Loose or incorrect wiring connections.
  • Tank or remote control not powered on.
  • Incorrect settings on the control board or TK16 MainBoard.
  • Low tank battery.
  • Check all connections between the smoke/flash unit and the TK16 MainBoard.
  • Ensure both the tank and remote control are powered on.
  • Verify dip switch and potentiometer settings. Consult TK16 MainBoard manual for remote control activation.
  • Recharge the tank's main battery.
No smoke output
  • No smoke fluid or low fluid level.
  • Blocked smoke nozzle or tubing.
  • Pump malfunction.
  • Refill smoke fluid reservoir.
  • Clear any obstructions from the nozzle and tubing.
  • If pump is suspected to be faulty, contact support.
Flash not working
  • Loose connection to flash unit.
  • Flash unit malfunction.
  • Check connections to the flash unit.
  • If flash unit is suspected to be faulty, contact support.

Specifications

Feature Detail
Brand Heng Long
Model ID TH17018-SMT4 (CS-SMOKEFLASH-TK16)
Material Plastic, Metal
Compatibility RC TK16 MainBoard, 1/16 RC Tank Models
Package Dimensions (Approx.) Length: 18 cm, Width: 8 cm, Height: 5 cm
Package Weight (Approx.) 0.5 kg
Recommended Age 14+ years
Is Electric No battery included (unit is powered by tank's mainboard)

User Tips

  • Always ensure the tank's main battery is fully charged for optimal smoke and flash performance.
  • Use high-quality smoke fluid specifically designed for RC tank smoke generators to prevent clogging and ensure consistent smoke output.
  • Regularly check the tubing for kinks or leaks to maintain proper smoke flow.

Warranty and Support

For warranty information, please refer to the terms and conditions provided by your retailer or contact the seller directly. If you encounter any issues or have questions regarding this product, please reach out to the seller for assistance.

A user manual in PDF format may also be available for additional details: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.