ORIA fridge thermometer wireless

Contents

User Manual: ORIA Wireless Fridge Thermometer

Digital Freezer Thermometer with Alarm and 2 Sensors

Product Overview

The ORIA Wireless Fridge Thermometer is a multi-functional digital thermo-hygrometer designed to monitor indoor and outdoor temperature and humidity. It comes with a main display unit and two remote sensors, making it ideal for use in refrigerators, freezers, kitchens, and other environments. The device features a clear LCD display, temperature alarm functions, and flexible installation options.

ORIA Wireless Fridge Thermometer main unit and two remote sensors

Main display unit and two remote sensors.

Product demonstration video showing the main unit and sensors.

Package Contents

Ensure all items are present in the package:

  • Wireless thermo-hygrometer (main unit) x 1
  • Wireless sensor x 2
  • USB charging cable for base unit x 1
  • Operating instruction manual x 1
  • Magnetic sticker x 1 (for main unit installation)
Contents of the product package including main unit, sensors, USB cable, and manual

Contents of the product package.

Setup

Power Supply

The main unit supports dual power supply options:

  1. Battery Mode (not included): Insert 3 x AAA 1.5V batteries into the battery compartment. The backlight will light up for 10 seconds when a button is pressed.
  2. Dual Power Supply (USB included): Plug the main unit into a wall outlet using the provided USB charging cable. The backlight will be continuously on with 3 adjustable brightness levels.

Important:

  • Do not use batteries with a voltage lower than 1.5V (e.g., 1.2V rechargeable batteries), as this may affect measurement accuracy.
  • If possible, use alkaline batteries as they last longer than zinc-carbon batteries.
Diagram showing dual power supply options for the main unit: battery compartment and USB power port

Dual power supply options for the main unit.

Wireless Sensor Battery Installation

Each wireless sensor requires 2 x AA 1.5V batteries (not included). Open the battery compartment on the back of each remote sensor and insert the batteries, ensuring correct polarity.

Pairing the Outdoor Sensor with the Thermo-Hygrometer

As soon as the base unit has power (from batteries or plug-in), it will automatically start receiving pairing RF signals from the outdoor sensors for 3 minutes. Generally, the outdoor sensors will connect with the base unit automatically. If pairing fails, follow these steps:

  1. Ensure that the thermo-hygrometer and outdoor sensors are set to the same channels (channel 1, 2). Use the sliding switch on the remote sensor to set its transmission channel.
  2. Long press the "-/RF" button on the base unit to search for signals from the outdoor sensors.
  3. The sensor receiving icon on the main unit's display will flash when searching for the signal.
  4. After the sensor is connected, the icon will become stable.

Your wireless thermometer will automatically search for the signal every 3 minutes each hour until it is connected.

Diagram illustrating the wireless transmission range of the remote sensors to the main unit

Wireless remote sensor transmission range.

Operating Instructions

Main Unit Display Overview

Detailed view of the main display unit with labels for various functions including time, date, indoor temp/humidity, sensor 1/2 temp/humidity, max/min records

Main display unit with key indicators.

No. Indicator Description
1AM/PMAM/PM hour format
2TimeCurrent time
3Sensor Alert SymbolSENSOR temperature alert symbol
4Sensor TemperatureTemperature reading from remote sensor
5ALL-TIME / 24HR RS symbolIndicates if MAX/MIN records are for 24 hours or all-time
6Stored MAX Sensor TemperatureMaximum stored SENSOR temperature value
7Low Battery Indicator (Outdoor)Low battery indicator for outdoor sensor
8Sensor HumidityHumidity reading from remote sensor
9Stored MIN Sensor HumidityMinimum stored SENSOR humidity value
10Stored MAX Sensor HumidityMaximum stored SENSOR humidity value
11Stored MIN Sensor TemperatureMinimum stored SENSOR temperature value
12DST SymbolDaylight Saving Time symbol
13Indoor HumidityIndoor humidity reading
14Indoor Humidity TrendTrend indicator for indoor humidity
15Indoor Temperature TrendTrend indicator for indoor temperature
16Indoor TemperatureIndoor temperature reading
17Indoor Comfort IndicatorIndicates indoor comfort level
18Low Battery Indicator (Indoor)Low battery indicator for the main unit
19Year/Month/DateCurrent year, month, and date

Operating Buttons

Button Function
Light Bulb IconShort press: Light up display for 10s (battery mode). Select display illumination (Bright/Dimmed/Off) (USB power mode).
CH1Short press: Turn on/off SENSOR 1 temperature alert. Long press: Activate alert setting mode for SENSOR 1.
CH2Short press: Turn on/off SENSOR 2 temperature alert. Long press: Activate alert setting mode for SENSOR 2.
MODEShort press: Turn on/off DST. Long press: Activate time setting mode.
+/CLESet values (increase). Switch 24HR/ALL-TIME stored MAX and MIN temperature and humidity values. Long press: Delete stored values and re-record.
-/RFSet values (decrease). Display SENSOR 1 and SENSOR 2 temperature alert values. Long press: Reconnect wireless sensor.

Setting Time, Date, and DST

  1. Press and hold the MODE button for 3 seconds until the YEAR starts flashing. You are now in the basic settings.
  2. Use the +/CLE or -/RF buttons to adjust the data.
  3. Press the MODE button to confirm the setting and move to the next item.
  4. The setting order is: YEAR → MONTH → DAY → 12/24HR format (default 12HR) → HOUR → MINUTES → Temperature unit C/F (default °F).

Note:

  • All settings can be skipped or ceased if no button is touched or pressed for 20 seconds.
  • The setting process cannot be interrupted. If interrupted, you will need to repeat the process from the beginning.

Setting Daylight Saving Time (DST)

The clock needs to be set for DST manually.

  • Short press the MODE button to activate or deactivate DST during the DST period.
  • When activated, the DST symbol will appear, and the clock will set forward by one hour.
  • When deactivated, the DST symbol will disappear, and the clock will set backward by one hour.

Note:

  • Please check and refer to your country's winter/summer time before setting DST.

Setting Temperature Alert Values (SENSOR 1 & SENSOR 2)

The temperature alert function allows you to set high and low temperature thresholds for each remote sensor.

Illustration of the temperature alarm function, showing remote sensors in a fridge/freezer and the main unit displaying an alarm

Temperature alarm in action.

For SENSOR 1:

  1. Long press the CH1 button to enter SENSOR 1 alert setting mode. The MAX temperature value will start flashing.
  2. Use the +/CLE or -/RF buttons to set the desired MAX temperature alert value.
  3. Press the CH1 button to store the changed setting. The MIN temperature value will then start flashing.
  4. Use the +/CLE or -/RF buttons to set the desired MIN temperature alert value.
  5. Press the CH1 button to store the changed setting.

For SENSOR 2:

Follow the same steps as for SENSOR 1, but use the CH2 button instead of CH1.

Note:

  • The temperature alert setting value range is -40°F ~ 158°F (-40°C ~ 70°C).
  • Default values: MAX temperature is 158°F (70°C), MIN temperature is -40°F (-40°C).

Activating/Deactivating Temperature Alert

The temperature alert is off by default and needs to be activated manually.

  • Short press the CH1 button to activate or deactivate the SENSOR 1 alert.
  • Short press the CH2 button to activate or deactivate the SENSOR 2 alert.
  • The alert icon 🔊 will appear on the display when activated.

Alert Behavior:

  • When the current temperature of SENSOR 1 or SENSOR 2 exceeds the set alert value, a beep sound will be triggered, and the corresponding temperature value and MAX or MIN icon will flash.
  • The beep sound will last for 2 minutes. The temperature and alert icon will continue to flash until the temperature falls below the set value.

Displaying Temperature Alert Settings

Short press the -/RF button to view the currently set alert values.

Switching 24HR and ALL-TIME Modes for Stored MAX/MIN Values

The device stores maximum and minimum temperature and humidity values for both SENSOR 1 and SENSOR 2. There are two modes for viewing these records:

  • 24 HOURS Mode: Indicates stored MAX and MIN values from the past 24 hours. "24HR" will appear on the display.
  • ALL-TIME Mode: Indicates stored MAX and MIN values since the device was powered on. "ALL-TIME" will appear on the display.

Short press the +/CLE button to switch between these modes.

Note:

  • The default mode is 24HR.

Deleting Stored MAX and MIN Temperature Values

  • 24 HOURS Mode: Stored MAX and MIN temperature values will reset automatically at midnight (12:00 AM).
  • ALL-TIME Mode: Stored MAX and MIN temperature values cannot reset automatically.

To manually delete stored 24HR and ALL-TIME values simultaneously, long press the +/CLE button.

Indoor Comfort Indicator

The indoor comfort indicator depends on the indoor humidity and indicates the comfort level a person would feel.

Humidity Range Indicator Comfort Level
<40%☹️DRY
40% ~ 70%😊COMFORTABLE
>70%🙁WET

Weather Trend

For indoor temperature and humidity values measured by the base unit, the trend is displayed by an arrow:

Trend Rising Constant Falling
Temperature↗→↘
Humidity↗→↘

Switching the Backlight On

A) Power Mains Operation (USB powered)

When the base unit is powered via the USB cable, the display is constantly illuminated. Press the 💡 button repeatedly to select the following settings for the display illumination: Bright >> Dimmed >> Off.

B) Battery Operation

When powered by batteries, press the 💡 button to light up the display for 10 seconds.

Low Battery Indicator

There is a low battery indicator when the device is powered by batteries.

  • When a low battery symbol appears near the "Sensor Humidity" indicator, you should replace the batteries of the wireless sensor.
  • When a low battery symbol appears near the "Indoor" symbol, you should replace the batteries of the thermo-hygrometer (main unit).

Action:

Replace the batteries in all devices as soon as possible. Restart the thermo-hygrometer after replacing batteries.

Maintenance

Resetting the Device

If the base station appears to display incorrect values, you should reset the thermo-hygrometer to the factory settings:

  1. Shut off the thermo-hygrometer (take out batteries or unplug the power cord).
  2. Take the batteries out of the outdoor sensors.
  3. Power on the thermo-hygrometer (put batteries in or plug the power cord).
  4. Put batteries back in the outdoor sensors.
  5. Place the main unit and sensors together within a couple of feet for about 20 minutes to establish a strong connection.

Troubleshooting

Problem Possible Solution
Display screen is not working
  • Check the battery polarity or battery level.
  • Check if the power cord is inserted tightly (if using USB power).
Time is incorrect
  • This device does not have a radio-controlled clock function. Please set the correct time manually.
Outdoor temperature is showing "-"
  • The "-" symbol generally indicates wireless interference or a lost connection. Follow the "Resetting the Device" steps to re-establish connection.
Inaccurate temperature or humidity readings
  • When unpacking for the first time, the thermo-hygrometer and sensors may need 1-2 hours to balance with the current ambient temperature.
  • Keep the device away from heat sources.
  • For comparison with other thermometers, place them in the same position and allow them to stand for at least 1 hour.
  • Place the device out of direct sunlight and away from any heat sources or vents to ensure accurate measurements.

Specifications

Image showing dimensions of the main unit and key specifications like temperature and humidity ranges and accuracy

Dimensions and key specifications.

Main Unit

  • Power supply: 3 x AAA Battery / 1.5 V (Not Included) or USB 5.0V / 500mA
  • Temperature measurement range: -9.9°C ~ 50°C (14.2°F ~ 122°F)
  • Temperature measurement accuracy: ±1°C (1.8°F) within 0°C ~ 40°C (32°F ~ 104°F), others ±2°C (3.6°F)
  • Temperature resolution: 0.1°C (0.1°F)
  • Humidity measuring range: 20 % ~ 95 %
  • Humidity measuring accuracy: ±5 % within 40% ~ 80% RH, others ±8% RH
  • Humidity resolution: 1 %
  • Temperature and humidity data update rate: Every 30 seconds

Wireless Sensors (x2)

  • Batteries: 2 x AA Battery / 1.5 V per unit (Not Included)
  • Temperature measuring range: -40°C ~ 70°C (-40°F to 158°F)
  • Protection type: IPX4 (Protection against splash water from all directions)
  • Transmission frequency: 433 MHz
  • Range: Max. 100 meters (328 ft) (in open area)
  • Temperature and humidity data update rate: CH1: every 31 seconds; CH2: every 32 seconds

Note on temperature range:

The remote sensors can operate down to -40°C (-40°F), which includes -18°C, making them suitable for freezers.

User Tips

  • Temperature Consistency: If you observe slight temperature differences between sensors or the indoor reading, this can be normal due to microclimates or sensor placement. For critical monitoring, ensure sensors are placed in similar, stable conditions.
  • Screen Protection: While the screen may not come with a protective film, handle with care to avoid scratches.
  • Interference: If you experience connection issues or "---" on the display, try repositioning the sensors and the main unit to minimize interference. The device supports two channels (1 and 2) for the remote sensors.

Warranty and Support

For detailed item guides and documents, please refer to the official PDF user manual. A link to the PDF is available from the seller's product page: User manual (PDF).

The product comes with standard consumer guarantees. For specific warranty claims or technical support, please contact the seller or manufacturer directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.