UNI-T UT217A UT217B

UNI-T UT217A UT217B Oscilloscope Clamp Meter User Manual

Models: UT217A, UT217B

1. Introduction and Overview

The UNI-T UT217A and UT217B are high-performance measurement tools that integrate both oscilloscope and clamp multimeter functions into a single device. These meters are designed for a wide range of applications, including power system detection, maintenance work, and use in fields such as electricity, industrial manufacturing, new energy, and automotive diagnostics.

The high-end models can measure AC/DC voltages up to 1000V and AC/DC currents up to 600A (UT217A) or 1000A (UT217B). The integrated oscilloscope function allows users to observe and analyze the waveform, amplitude, and frequency of electrical signals, providing comprehensive diagnostic capabilities. Key features include a 2.8-inch high-definition LCD with dual theme display, Bluetooth connectivity for mobile app integration, surge current measurement, and a durable, ergonomic design.

UNI-T UT217A and UT217B Oscilloscope Clamp Meters
Figure 1: UNI-T UT217A and UT217B Oscilloscope Clamp Meters

2. Setup

2.1 Initial Charging

The UT217 series clamp meters feature a built-in 3.7V 2600mAh rechargeable lithium battery, providing long-lasting endurance. Before first use, ensure the device is fully charged using the provided Type-C charging cable.

Type-C Charging Port and Battery Indicator
Figure 2: Type-C Charging Port and Battery Indicator

2.2 Power On/Off and Mode Switching

To power on the device, short press the power button. To power off, long press the power button. After powering on, a short press of the function page switch key allows you to switch between oscilloscope and multimeter modes.

Labeled parts of the UT217A clamp meter
Figure 3: Key controls and interfaces of the UT217A

2.3 Jaw Opening

The UT217A features a 31mm jaw opening, while the UT217B has a 38mm jaw opening. The narrow-edge elongated opening design is suitable for measuring in tight spaces and around larger wire diameters, ensuring flexibility and applicability.

Jaw opening comparison between UT217A and UT217B
Figure 4: Jaw opening sizes for UT217A (31mm) and UT217B (38mm)

3. Operating Instructions

3.1 General Operation and Display

The device is fully button-operated, allowing for quick one-handed switching between functions. It features a 2.8-inch high-definition LCD display screen with a color display and two display modes. This dual theme display adapts to different lighting environments, ensuring clear readings and rich visual information.

High-definition color display with dual themes
Figure 5: High-definition color display with dual themes for readability

3.2 High Voltage Warning

For safety, when the measured voltage exceeds 42V/DC safe voltage, the instrument screen will display a high voltage warning symbol (a red lightning bolt) and a red alert at the top of the interface. Always pay attention to these warnings and follow safety protocols.

42V High Voltage Warning on display
Figure 6: High Voltage Warning displayed on the meter

3.3 Oscilloscope Function

The oscilloscope function allows for the measurement of current and voltage waveforms. It provides detailed analysis of electrical signals, including waveform shape, amplitude, frequency, period, and pulse width. This is crucial for engineers in circuit design and debugging.

  • Bandwidth: Voltage 1MHz, Current 1KHz
  • Real-time sampling rate: 5.0 MSa/s
  • Maximum input voltage: 1000V
  • Maximum sampling current: UT217A: 600A, UT217B: 1000A

Applications include current waveform measurement, voltage waveform measurement, electronic maintenance, three-phase voltage measurement, and general current measurement.

Applications of oscilloscope function including current and voltage waveform measurement
Figure 7: Various applications of the oscilloscope function

3.4 Multimeter Functions

The UT217 series offers a 20000-count true effective value (True RMS) automatic range clamp meter. It supports a wide array of measurements:

  • AC/DC Voltage up to 1000V
  • AC/DC Current up to 600A (UT217A) / 1000A (UT217B)
  • Resistance, Capacitance, Frequency, Duty Cycle
  • Diode and Continuity tests
  • Non-Contact Voltage (NCV) detection

The automatic range feature and intelligent burn protection make it a convenient and practical tool for various electrical and electronic tasks.

3.5 NCV Function

The Non-Contact Voltage (NCV) detection function enhances safety and operational convenience. It allows you to locate electrical faults, such as breaks or short circuits, without needing to disassemble the entire circuit, minimizing risk and effort.

3.6 Surge Current Measurement

The device can monitor surge currents (AC current only), detecting abnormal high current peaks during equipment startup. This feature helps in taking timely measures to protect sensitive electronic devices from potential damage caused by inrush currents.

3.7 Frequency/Duty Cycle Measurement

The meter supports frequency measurement from 1-20V up to 20.000MHz, and for high voltage, it measures frequency from 40-1kHz, while also displaying the duty cycle. This ensures normal operation of electrical equipment, protects sensitive devices, and helps maintain power system stability.

Frequency and Duty Cycle Measurement
Figure 8: Frequency and Duty Cycle Measurement in action

3.8 Bluetooth App Connectivity

The entire series comes standard with mobile analysis software. Users can connect the device to a mobile app via Bluetooth for real-time transmission of measurement results. The app allows for data analysis and storage of multimeter function data in CSV format for later viewing and detailed review.

Mobile Bluetooth analysis software interface
Figure 9: Mobile Bluetooth analysis software for data management
Video 1: Demonstration of UNI-T UT217 series features and measurements.

4. User Tips

  • Battery Check: The UT217 series includes a built-in rechargeable lithium battery. If you encounter issues with power, ensure the device is fully charged via the Type-C port.
  • Data Logging: Maximize the utility of your clamp meter by connecting it to the mobile app via Bluetooth. This allows for real-time data transmission, analysis, and convenient export of measurement data in CSV format for detailed record-keeping and review.
  • Safety First: Always observe the 42V high voltage warning displayed on the screen when measuring voltages above this threshold. Prioritize safety by wearing appropriate personal protective equipment, such as insulated gloves, when working with live circuits.

5. Troubleshooting

If you encounter issues with your UNI-T UT217 series clamp meter, consider the following basic troubleshooting steps:

  • Device Not Powering On: Ensure the internal rechargeable battery is fully charged. Connect the device to a Type-C charger and allow sufficient time for charging.
  • Inconsistent or Incorrect Readings:
    1. Check that the test leads are securely connected to the correct input jacks.
    2. Verify that the measurement mode selected on the device matches the type of measurement you are performing (e.g., AC voltage, DC current, oscilloscope mode).
    3. Ensure the clamp jaw is fully closed around the conductor for current measurements.
    4. For voltage measurements, confirm proper contact with the circuit points.
  • Bluetooth Connectivity Issues:
    1. Ensure Bluetooth is enabled on both the clamp meter and your mobile device.
    2. Make sure the mobile app is installed and updated to the latest version.
    3. Try restarting both the clamp meter and your mobile device.
    4. Ensure the devices are within the effective Bluetooth range.
  • Display Problems: If the display is dim or unreadable, adjust the display theme settings to better suit your lighting environment.

For more detailed troubleshooting or persistent issues, please refer to the comprehensive user manual included with your product or contact UNI-T customer support.

6. Specifications

6.1 General Specifications

  • Brand Name: UNI-T
  • Model Number: UT217A, UT217B
  • UNI-T Model: UT217
  • DIY Supplies: Electrical
  • Origin: Mainland China
  • Certification: CE, FCC, RoHS, UL, KC, PSE, WEEE
  • Battery Included: No (features a built-in rechargeable battery)
  • High-concerned chemical: None

6.2 Detailed Specifications

Detailed product specifications table
Figure 10: Detailed Multimeter and Oscilloscope Specifications
Multimeter Functions
FunctionRange (UT217A)Range (UT217B)ResolutionAccuracy
DC Voltage20.000mV, 200.00mV, 2.000V, 20.00V, 200.0V, 1000V20.000mV, 200.00mV, 2.000V, 20.00V, 200.0V, 1000V0.001mV, 0.01mV, 0.001V, 0.01V, 0.1V, 1V±(0.1%+20dig), ±(0.1%+5dig)
AC Voltage20.000mV, 200.00mV, 2.000V, 20.00V, 200.0V, 1000V20.000mV, 200.00mV, 2.000V, 20.00V, 200.0V, 1000V0.001mV, 0.01mV, 0.001V, 0.01V, 0.1V, 1V±(0.8%+10dig) (Frequency: 40Hz-1000Hz)
DC Current20.00A, 200.0A, 600A20.00A, 200.0A, 1000A0.01A, 0.1A, 1A±(2.0%+10dig)
AC Current20.00A, 200.0A, 600A20.00A, 200.0A, 1000A0.01A, 0.1A, 1A±(1.9%+10dig) (Frequency: 40Hz-1000Hz)
Surge Current200.0A, 600A200.0A, 1000A0.1A, 1A±(3.0%+10dig) (Frequency: 40Hz-1000Hz)
Resistance200.00Ω, 2.000kΩ, 20.00kΩ, 200.0kΩ, 2.000MΩ, 20.00MΩ, 100.00MΩ200.00Ω, 2.000kΩ, 20.00kΩ, 200.0kΩ, 2.000MΩ, 20.00MΩ, 100.00MΩ0.01Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ, 0.1MΩ±(0.3%+10dig), ±(0.5%+3dig), ±(3.0%+10dig)
Capacitance20nF/200nF/2μF/20μF/200μF/2mF/20mF20nF/200nF/2μF/20μF/200μF/2mF/20mF0.001nF±(3.0%+10dig)
Frequency0.1%~99.9% (typical 1V) ±(1.0%+10dig)0.1%~99.9% (typical 1V) ±(1.0%+10dig)0.001Hz±(1.0%+10dig)
Duty Cycle0.1%~99.9% (≥1 KHz)0.1%~99.9% (≥1 KHz)0.1%Open circuit voltage: 3.7V
Diode/On/Off0~200.0Ω0~200.0ΩBuzzer limit 60Ω; 00.0Ω displays measurement values, exceeding will show 'OL'
NCV
Oscilloscope Functions
FeatureUT217AUT217B
BandwidthVoltage: 1MHz, Current: 1KHzVoltage: 1MHz, Current: 1KHz
Real-time sampling rate5.0 MSa/s5.0 MSa/s
Number of channels11
Input impedance≥10 MΩ≥10 MΩ
Maximum input voltageMaximum peak current 600.0VMaximum peak current 1000V
Maximum sampling current600A1000A
Scanning speed2.5 div/s ~ 25 div/s2.5 div/s ~ 25 div/s
Time base accuracy±(0.01%+10dig)±(0.01%+10dig)
Sensitivity30 mV/div ~ 500 V/div30 mV/div ~ 500 V/div
Displacement range±8 div case±8 div case
Sensitivity accuracy±(2.0%+10dig)±(2.0%+10dig)
Measurement valueEffective value, maximum value, minimum value, peak-to-peak value, average value.Effective value, maximum value, minimum value, peak-to-peak value, average value.
Trigger typeRising edge, falling edgeRising edge, falling edge
Bluetooth communication
Auto-meter
True effective value
Display modeDMM/OSCDMM/OSC
Zero measurement
Input protection

7. Maintenance

To ensure the longevity and accurate performance of your UNI-T UT217 series clamp meter, follow these maintenance guidelines:

  • Cleaning: Regularly clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the casing or display.
  • Battery Care: The built-in lithium battery should be charged regularly, even if the device is not in frequent use, to maintain battery health. Avoid fully discharging the battery for extended periods.
  • Storage: Store the clamp meter in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity. If storing for a long period, ensure the battery is partially charged (around 50%) and recharge it every few months.
  • Avoid Impact: Protect the device from drops and impacts, which can damage internal components or the display.
  • Calibration: For professional applications requiring high accuracy, periodic calibration by authorized service centers is recommended.

8. Warranty and Support

UNI-T products are manufactured to high-quality standards and come with a standard warranty. For specific warranty terms and conditions, please refer to the warranty certificate included in your product packaging. For technical support, service, or to learn more about UNI-T products, please visit the official UNI-T website at www.uni-trend.com.cn.

Product package contents
Figure 11: Standard package contents including user manual and warranty certificate

Related Documents - UT217A UT217B

Preview UNI-T UT217 Series Clamp Meter Oscilloscope Operating Manual
Comprehensive operating manual for UNI-T UT217 Series clamp meter oscilloscopes (UT217A, UT217B), covering safety, usage, technical specifications, and maintenance.
Preview UNI-T UT217A and UT217B Digital Clamp Meter and Oscilloscope User Manual
Comprehensive user manual for the UNI-T UT217A and UT217B digital clamp meters, featuring integrated oscilloscope functionality, technical specifications, and safety operating instructions.
Preview UNI-T UT210E PRO Mini Clamp Meter Operation Manual
This document provides a comprehensive operation manual for the UNI-T UT210E PRO Mini Clamp Meter, detailing its features, safety precautions, technical specifications, and operating instructions for various electrical measurements.
Preview UNI-T UT210D Mini Clamp Meter Operation Manual
This operation manual provides detailed instructions for the UNI-T UT210D Mini Clamp Meter, covering its features, safety precautions, electrical symbols, and operational procedures for measuring various electrical parameters.
Preview UNI-T UT205E/UT206B/UT207B/UT208B 1000A True RMS Digital Clamp Meter Operating Manual
Comprehensive operating manual for the UNI-T UT205E, UT206B, UT207B, and UT208B 1000A True RMS Digital Clamp Meters. Covers features, safety instructions, electrical symbols, external structure, LCD display, function controls, specifications, detailed operating instructions for various measurements, and maintenance procedures.
Preview UNI-T UT256B 200A True RMS Fork Meter Operating Manual
Operating manual for the UNI-T UT256B 200A True RMS Fork Meter, covering safety, specifications, functions, and measurement procedures for AC/DC current, voltage, resistance, capacitance, and more.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.