1. Introduction
The Hantek DPO7000 Series Digital Oscilloscope is a versatile and professional measurement instrument designed for a wide range of electronic testing and analysis applications. This series integrates multiple functions into a single device, including an oscilloscope, 16-channel logic analyzer, spectrum analyzer, arbitrary waveform generator, digital voltmeter, frequency meter, and protocol analyzer. Featuring a 10.1-inch multi-touch capacitive screen, high sampling rates, and deep memory, it provides comprehensive tools for waveform capture, analysis, and debugging.
This manual provides essential information for the safe and effective use of your Hantek DPO7000 Series Digital Oscilloscope. Please read it thoroughly before operation.
2. Key Features
- Multi-Instrument Integration: Combines 8 independent instruments: oscilloscope, 16-channel logic analyzer, spectrum analyzer, arbitrary waveform generator, digital voltmeter, frequency meter and accumulator, and protocol analyzer.
- High Performance: Real-time sampling rate up to 2GSa/s, 2G memory depth, and hardware real-time waveform recording and playback up to 2 million frames.
- Advanced Display: 10.1-inch multi-touch capacitive screen with 256-level waveform gray scale and color temperature display for clear signal visualization.
- Fast Waveform Capture: Waveform capture rate exceeding 500,000 waveforms per second.
- Comprehensive Measurement: Up to 51 types of automatic waveform parameter measurements, supporting statistics and analysis.
- Rich Protocol Support: Extensive serial protocol triggering and decoding functions, including UART, I2C, SPI, LIN, and CAN.
- Data Analysis: Multiple data analysis and processing functions such as independent search, navigation keys, event list, histogram, Bode plot, power analysis, and counter.
- Arbitrary Waveform Generator: Built-in 25MHz waveform generator with 200 MSa/s sampling rate and 12-bit vertical resolution, supporting 13 standard waveforms.
3. Physical Overview
3.1 Front Panel
The front panel features the 10.1-inch multi-touch display, control knobs, and buttons for vertical, horizontal, and trigger settings. Input channels (CH1, CH2, CH3, CH4) are clearly labeled for probe connections.

3.2 Rear Panel
The rear panel provides various connectivity options for external devices and power. These include LAN, USB DEVICE, 10MHz In/Out, EXT In, G1 Out, Trig Out, Pass/Fail Out, HDMI, and RS-232 ports, along with the AC power input.

4. Specifications
| Parameter | DPO7504E | DPO7354E | DPO7204E | DPO7104E |
|---|---|---|---|---|
| Channel | 4 Channel Oscilloscope + 1 Channel Waveform Generator + 16 Channel Logic Analyzer | |||
| Bandwidth | 500MHz | 350MHz | 200MHz | 100MHz |
| Real-time Sampling Rate | 2GSa/s single channel, 2GSa/s half channel, 1GSa/s all channel | |||
| Memory Depth | 2Gpts (single channel), 1Gpts (dual channel), 500Mpts (three-four channels), 250Mpts (full channel) | |||
| Waveform Capture Rate | 500,000 wfms/s [25ns dot display single channel automatic memory depth] | |||
| Vertical Resolution | 8 bit | |||
| Vertical Sensitivity | 1 MΩ: 500μV/div ~ 10 V/div; 50 Ω: 500μV/div ~ 1 V/div | |||
| Time Base Range | 500ps/div~1ks/div | 1ns/div~1ks/div | 2ns/div~1ks/div | 2ns/div~1ks/div |
| Time Base Accuracy | ±1 ppm ± 1 ppm/year | |||
| Bandwidth limitation | 20 MHz, 100MHz, 200MHz, 350MHz; Independent optional for each channel | |||
| Trigger Type | Edge, Pulse, Video, Slope, Overtime, Window, Logic, Overamp, Runt, Pattern, Delay, Setup/Hold, Nth Edge, UART, LIN, CAN, SPI, I2C | |||
| Bus and Decoding | UART, I2C, SPI, LIN, CAN | |||
| Mathematical Operation | A+B, A-B, A*B, A/B, FFT, A&&B, A||B, A^B, !A, Intg, Diff, Sqrt, Lg, Ln, Exp, Abs, LowPass, HighPass, BandPass, BandStop, AX+B, Expression | |||
| Automatic Measurement | 51 kinds of parameter measurement, supporting statistics and analysis | |||
| Analysis Function | Frequency meter, DVM, Power Analyzer, Histogram, Search, Navigate, Record, Bode Set | |||
| Hardware Recording and Playback | More than 2 million frames (single channel) | |||
| Input Coupling | DC, AC or GND | |||
| Input Impedance and Capacitance | 1 MΩ ± 1%, 50 Ω ± 1%; 19 pF ± 3 pF | |||
| Arbitrary Waveform Generator | Sampling rate 200 MSa/s, vertical resolution 12 bit, maximum output frequency 25 MHz, Sine, Square, Pulse, Ramp, Noise, DC, Sinc, Exp.rise, Exp.fall, Lorentz, Gauss, ECG, Haversine and other 13 standard waveforms | |||
| Digital Channel | 16CH, 1GSa/s sampling rate | |||
| Interface | USB HOST, USB DEVICE, LAN; option: HDMI, serial port | |||
| Screen | 10.1 inch multi-touch capacitive screen, 256 level waveform grayscale display, with color afterglow | |||
5. Setup
5.1 Unpacking and Inspection
Carefully remove the oscilloscope and all accessories from the packaging. Inspect the device for any signs of damage during transit. If any damage is found, contact your supplier immediately.
5.2 Power Connection
- Ensure the oscilloscope is placed on a stable, flat surface with adequate ventilation.
- Connect the provided AC power cord to the power input on the rear panel of the oscilloscope.
- Plug the other end of the power cord into a grounded AC power outlet.
5.3 Probe Connection
- Connect the BNC connector of the oscilloscope probe to one of the input channels (CH1, CH2, CH3, or CH4) on the front panel.
- Ensure the probe is securely twisted into place.
- Attach the probe ground clip to the circuit ground of the device under test.
- Connect the probe tip to the test point on the circuit.
5.4 Initial Power On
Press the power button on the front panel to turn on the oscilloscope. The device will perform a self-test and display the main interface.
6. Operating Instructions
6.1 Basic Controls
- Vertical Controls: Use the vertical scale (Volts/Div) knobs to adjust the vertical sensitivity of each channel. Use the position knobs to move the waveform vertically.
- Horizontal Controls: Use the horizontal scale (Sec/Div) knob to adjust the time base. Use the position knob to move the waveform horizontally.
- Trigger Controls: The trigger system stabilizes repetitive waveforms. Adjust the trigger level to set the voltage point at which the oscilloscope starts acquiring data. Select trigger type (Edge, Pulse, etc.) and source (CH1, CH2, etc.) using the dedicated controls.
6.2 Using the Touch Screen
The 10.1-inch multi-touch capacitive screen allows for intuitive interaction. You can pinch to zoom, drag to pan, and tap to select menu options or adjust settings. Specific gestures and touch functions are detailed in the comprehensive PDF manual.
6.3 Waveform Measurement and Analysis
The DPO7000 series offers 51 types of automatic measurements. Access these through the 'Measure' menu. The device also supports advanced analysis functions like FFT, histograms, and power analysis, accessible via the 'Analyze' menu.

7. Maintenance
7.1 Cleaning
To clean the exterior of the oscilloscope, use a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners or solvents that could damage the plastic casing or screen. For the screen, use a specialized screen cleaner and a microfiber cloth.
7.2 Storage
When not in use for extended periods, store the oscilloscope in a dry, dust-free environment, away from direct sunlight and extreme temperatures. It is recommended to use the original packaging or a protective case.
7.3 Calibration
For optimal performance, periodic calibration by qualified personnel is recommended. Refer to the PDF manual for recommended calibration intervals and procedures.
8. Troubleshooting
- No Power: Ensure the power cord is securely connected to both the oscilloscope and a working power outlet. Check the power switch position.
- No Signal Displayed: Verify that probes are correctly connected to both the oscilloscope channels and the circuit under test. Check probe settings (e.g., 1X/10X attenuation) and channel input coupling (AC/DC/GND). Adjust vertical scale and trigger level.
- Distorted or Unstable Waveform: Adjust the trigger settings (level, source, type) to stabilize the waveform. Check probe compensation. Ensure the input signal is within the oscilloscope's voltage and frequency limits.
- Touch Screen Unresponsive: Try restarting the device. If the issue persists, consult the PDF manual for advanced troubleshooting or contact support.
9. Safety Notes
- Always connect the oscilloscope to a properly grounded power outlet to prevent electric shock.
- Do not use the oscilloscope in wet or damp conditions.
- Ensure that the voltage and current of the signals being measured do not exceed the maximum input ratings of the oscilloscope and probes.
- Use only probes designed for the oscilloscope and appropriate for the voltage levels being measured.
- Do not attempt to open or repair the oscilloscope yourself, as this may void the warranty and expose you to hazardous voltages. Refer all servicing to qualified personnel.
- Keep the device away from strong electromagnetic interference sources.
10. Package Contents
The standard package for the Hantek DPO7000 Series Digital Oscilloscope typically includes:
- Hantek DPO7000 Series Digital Oscilloscope Unit
- Passive Probes (quantity may vary by model)
- Power Cord
- USB Cable
- User Manual (PDF available for download/reference)
- Calibration Certificate (if applicable)
11. Warranty and Support
The Hantek DPO7000 Series Digital Oscilloscope comes with a 1-year warranty from the date of purchase, covering manufacturing defects. This warranty does not cover damage caused by misuse, accidents, unauthorized modifications, or improper operation. For warranty claims or technical support, please contact your vendor or Hantek customer service.
12. Additional Resources
For a more detailed and comprehensive guide, including advanced features, specific operating procedures, and detailed troubleshooting, please refer to the official user manual in PDF format: