Hantek TO1000 Series (TO1112, TO1112C, TO1112D, TO1154C, TO1204C, TO1254C, TO1154D, TO1204D, TO1254D, TO1152C, TO1202C, TO1252C, TO1152D, TO1202D, TO1252D)

Contents

Hantek TO1000 Series Tablet Oscilloscope User Manual

Models: TO1112, TO1112C, TO1112D, TO1154C, TO1204C, TO1254C, TO1154D, TO1204D, TO1254D, TO1152C, TO1202C, TO1252C, TO1152D, TO1202D, TO1252D

1. Introduction

The Hantek TO1000 series is a new generation of multi-functional full touch screen tablet oscilloscopes. Designed for portability and durability, it features a thin body, light weight, and a unique hanging design for hands-free operation, making it anti-falling and anti-seismic. This versatile device integrates an oscilloscope, multimeter, signal generator, and spectrum analyzer into one unit. It boasts a built-in large-capacity battery for extended endurance and supports fast charging via a standard 18W Type-C charger.

The device features a multi-touch 7-inch LCD screen with a resolution of 800x480, offering a friendly and easy-to-use interface for a good interaction experience.

Front view of Hantek TO1000 series tablet oscilloscope displaying waveforms.
Front view of the Hantek TO1000 series tablet oscilloscope displaying various waveforms.

2. Safety Information

Always operate the device in accordance with the instructions provided in the user manual. Ensure proper handling of probes and connections to avoid electrical shock or damage to the device. Do not expose the device to extreme temperatures, humidity, or corrosive environments. Only use the provided charging equipment or compatible Type-C 18W fast chargers. Refer to the detailed PDF user manual for comprehensive safety guidelines.

For a complete and detailed user manual, please refer to the official PDF document: Hantek TO1000 Series User Manual (PDF)

3. Device Overview

3.1 Front Panel

Frontal view of the Hantek TO1254D tablet oscilloscope.
Frontal view of the Hantek TO1254D tablet oscilloscope, highlighting the display and side controls.

The front panel is dominated by the 7-inch multi-touch LCD screen. On the left side, there are dedicated buttons for HOME, OSC (Oscilloscope), DMM (Digital Multimeter), AFG (Arbitrary Function Generator), H/R (Hold/Run), and PRINT functions.

3.2 Side and Top Panels

Side view of the Hantek TO1254D tablet oscilloscope showing USB port and kickstand.
Side view showing the USB port and integrated kickstand for convenient positioning.
Top view of the Hantek TO1000 series oscilloscope showing BNC input channels (CH1-CH4) and AFG output.
Top view displaying the BNC input connectors for channels CH1-CH4 and the AFG output.
Side view of the Hantek TO1000 series oscilloscope showing DMM input terminals.
Side view showing the dedicated input terminals for the Digital Multimeter (DMM) function.

The device includes USB Host and USB Device interfaces for connectivity. The top panel features BNC connectors for oscilloscope channels (CH1-CH4) and an AFG output for models with signal generator functionality. The side panel houses input jacks for the digital multimeter.

4. Initial Setup

4.1 Charging the Battery

The TO1000 series oscilloscope comes with a built-in super large capacity lithium battery (7500mAh). Before initial use, it is recommended to fully charge the device. Use the provided 18W Type-C charger or any compatible fast charger. The charging port is located on the side of the device. A full charge ensures long endurance, with standby time up to half a year.

4.2 Power On/Off

Press and hold the power button (usually located on the side or top) to turn the device on or off. The multi-touch screen will display the boot-up sequence.

4.3 Adjusting the Kickstand

The unique suspension foot design allows for multi-angle adjustment, providing stability and optimal viewing during operation. Simply pull out the kickstand from the back of the device and adjust it to your desired angle.

5. Operation

The TO1000 series features a full touch screen interface for intuitive operation. Most functions can be accessed and controlled directly via touch gestures and on-screen menus.

Close-up of the Hantek TO1000 series touchscreen interface demonstrating waveform generation and measurement functions.
Touchscreen interface demonstrating waveform generation and measurement capabilities.

5.1 Oscilloscope Function (OSC)

Press the 'OSC' button on the left panel to enter oscilloscope mode. Use the touch screen to adjust settings such as vertical sensitivity (V/div), time base (s/div), trigger type, and coupling. Connect probes to the BNC input channels (CH1-CH4) on the top panel.

5.2 Digital Multimeter Function (DMM)

Press the 'DMM' button to switch to digital multimeter mode. Connect multimeter leads to the dedicated input terminals on the side panel. Select the desired measurement function (e.g., DC Voltage, AC Current, Resistance) from the on-screen menu. The DMM provides high-precision measurements with data recording, storage, trend charts, and statistical analysis.

5.3 Arbitrary Function Generator (AFG)

For 'D' models, press the 'AFG' button to access the signal generator. Select from a variety of built-in standard waveforms (Sine, Square, Ramp, Pulse, Noise, DC) or arbitrary waveforms. Adjust parameters such as frequency (up to 25MHz), amplitude, offset, and duty cycle using the touch interface. Connect the output from the AFG BNC connector on the top panel.

5.4 Waveform Storage

The device supports one-key waveform storage for convenience. You can store up to 4 sets of reference waveforms, 4 sets of settings, and 4 sets of captured waveforms.

6. Maintenance

6.1 Cleaning

To clean the device, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the ports or buttons. Do not use abrasive cleaners or solvents.

6.2 Battery Care

To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, ensure the battery is charged to approximately 50-70% and store in a cool, dry place. Recharge periodically if stored for very long durations.

6.3 Software Updates

Check the official Hantek website periodically for any available firmware updates to ensure optimal performance and access to new features.

7. Troubleshooting

7.1 Device Not Powering On

  • Ensure the battery is sufficiently charged. Connect the device to the charger and wait a few minutes before attempting to power on again.
  • Verify the power button is pressed and held correctly.

7.2 No Waveform Displayed

  • Check probe connections to the BNC input channels and the circuit under test.
  • Ensure the oscilloscope is in 'OSC' mode.
  • Adjust vertical sensitivity (V/div) and time base (s/div) settings to match the expected signal characteristics.
  • Verify trigger settings are appropriate for the signal.
  • Check input coupling (DC, AC, GND) is set correctly.

7.3 Multimeter Readings Incorrect

  • Ensure multimeter leads are correctly inserted into the DMM input terminals.
  • Verify the correct measurement function (voltage, current, resistance, etc.) is selected.
  • Check the range setting; if auto-ranging is off, select an appropriate range.

7.4 Signal Generator Not Outputting

  • Ensure the device is a 'D' model (e.g., TO1154D, TO1204D, TO1254D) which includes the AFG function.
  • Verify the AFG output is connected correctly.
  • Check that the AFG function is enabled and parameters (frequency, amplitude) are set to non-zero values.

8. Specifications

Detailed technical specifications for Hantek TO1000 series oscilloscopes.
Detailed technical specifications for the Hantek TO1000 series oscilloscopes.

8.1 Model Overview

ModelOscilloscope ChannelsBandwidthSampling RateStorage DepthSignal SourceMultimeter
TO11122 CH110 MHz250MSa/S8M--
TO1112C2 CH110 MHz250MSa/S8M-√
TO1112D2 CH110 MHz250MSa/S8M√√
TO1154C4 CH150 MHz1GSa/s8M-√
TO1204C4 CH200 MHz1GSa/s8M-√
TO1254C4 CH250 MHz1GSa/s8M-√
TO1154D4 CH+1CH150 MHz1GSa/s8M25MHz√
TO1204D4 CH+1CH200 MHz1GSa/s8M25MHz√
TO1254D4 CH+1CH250 MHz1GSa/s8M25MHz√
TO1152C2 CH150 MHz1GSa/s8M-√
TO1202C2 CH200 MHz1GSa/s8M-√
TO1252C2 CH250 MHz1GSa/s8M-√
TO1152D2 CH+1CH150 MHz1GSa/s8M25MHz√
TO1202D2 CH+1CH200 MHz1GSa/s8M25MHz√
TO1252D2 CH+1CH250 MHz1GSa/s8M25MHz√

8.2 Oscilloscope (Common Specifications)

  • Input Coupling: DC, AC, GND
  • Input Impedance: 1MΩ ±2%, in parallel with 15pF ±5pF
  • Max Input Voltage: 400V (DC+AC Peak)
  • Vertical Resolution: 8 bit
  • Vertical Sensitivity: 2mV/div - 10V/div
  • Time Base Range: 2ns/div - 1000s/div
  • Trigger Types: Edge, Pulse, Video, Slope, Timeout, Window, Pattern, Interval, Runt, UART, LIN, CAN, SPI, IIC
  • Cursor Measurement: ΔV, ΔT, 1/ΔT
  • Automatic Measurement: Max, Min, Pk-Pk, Top, Base, Amp, Avg, Mean, RMS, CursRMS, Duty Cycle, Period, Freq, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A→B↑, Delay A→B↓, Phase A→B↑, Phase A→B↓, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF
  • Waveform Math: +, -, *, /, FFT
  • Waveform Storage: 4 sets of reference waveforms, 4 sets of settings, 4 sets of waveforms
  • Interface: USB Host, USB Device, Pass/Fail

8.3 Digital Multimeter (DMM) Specifications

  • DC Voltage: 60mV, 600mV, 6V, 60V, 600V, 1000V
  • AC Voltage: 60mV, 600mV, 6V, 60V, 600V, 750V
  • DC Current: 60mA, 600mA, 6A, 10A
  • AC Current: 60mA, 600mA, 6A, 10A
  • Resistance: 600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ
  • Capacitance: 40nF, 400nF, 4uF, 40uF, 400uF, 4mF
  • Diode Test: Yes
  • Continuity Test: Yes

8.4 Signal Generator (AFG) Specifications (for 'D' models)

  • Output Channels: 1 CH
  • Sample Rate: 200 MSa/s
  • Vertical Resolution: 12 bit
  • Max Output Frequency: 25 MHz
  • Standard Waveforms: Sine, Square, Ramp, Pulse, Noise, DC
  • Arbitrary Waveforms: Exp Rise, Exp Fall, Sin(x)/x, Step, Multi-tone, Lorentz, etc.

8.5 General Specifications

  • Display: 7-inch TFT LCD, 800x480 resolution, Multi-touch screen
  • Battery: Built-in Lithium battery, 7500mAh
  • Charging: Type-C, 18W fast charging
  • Dimensions: 248mm x 176mm x 54mm
  • Weight: Approx. 1.2 kg
  • Operating Environment: 0°C to 50°C, Humidity ≤90% RH
  • Storage Environment: -20°C to 70°C, Humidity ≤90% RH

9. Warranty and Support

9.1 Warranty Information

All products are checked and packed in good condition before dispatching. The Hantek TO1000 series oscilloscope comes with a one-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.

9.2 Contact Support

For any questions, technical assistance, or warranty claims, please contact customer service:

  • WhatsApp: +86 15244291916
  • Email: 773875441@qq.com
  • Office Tel: 0086-755-27541660
  • Cellphone: 0086-15967476818
  • Trademanager: cn901815702

All inquiries will be replied to within 24 hours.

Warranty and contact information for Shenzhen Graigar Technology Co., Ltd.
Contact and warranty information.

10. User Tips

  • Maximize Battery Life: Utilize the 18W fast charging feature, but for long-term storage, keep the battery charged to around 50-70% to preserve its health.
  • Portability: Take advantage of the unique hanging design and kickstand for flexible positioning in various work environments.
  • Touch Screen Efficiency: Familiarize yourself with the multi-touch gestures for quick navigation and parameter adjustments, enhancing your workflow.
  • Data Management: Regularly save important waveforms and settings using the one-key storage function to prevent data loss.