1. Introduction

The ASA VI Curve Tester is a versatile tool designed for circuit board maintenance and component testing. It works in conjunction with an oscilloscope to display characteristic voltage-current (VI) curves of electronic components, allowing for quick and efficient fault diagnosis on unpowered circuit boards. This manual provides essential information for the safe and effective operation of your VI Curve Tester.

2. Safety Information

  • Prohibit Live Measurement: Always ensure the circuit board or component under test is completely unpowered before connecting the VI Curve Tester. Measuring live circuits can damage the tester, the oscilloscope, and pose a safety risk.
  • Use only the specified power adapter for the device.
  • Do not operate the device in wet or damp conditions.
  • Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
  • Keep the device away from strong electromagnetic fields.

3. Setup

3.1 Package Contents

Depending on your specific model (NI-210G, NI-210SJ, NI-210SS) and purchased configuration, your package may include:

  • ASA VI Curve Tester unit
  • Test leads (red, black, blue)
  • Power adapter
  • BNC cables for oscilloscope connection
  • VI Test Board (accessory for component characteristic learning)

3.2 Connecting to an Oscilloscope

The VI Curve Tester requires a dual-channel analog oscilloscope for operation. Follow these steps:

  1. Connect the 'X' output (or Channel 1) of the VI Curve Tester to the X-input (or Channel 1) of your oscilloscope using a BNC cable.
  2. Connect the 'Y' output (or Channel 2) of the VI Curve Tester to the Y-input (or Channel 2) of your oscilloscope using a BNC cable.
  3. Set your oscilloscope to X-Y mode.
  4. Adjust the oscilloscope's horizontal (X) and vertical (Y) sensitivity to achieve a clear and appropriately sized curve display.
Connection diagram for VI Curve Tester to Oscilloscope
Figure 3.2.1: Connection Diagram for VI Curve Tester to Oscilloscope. Connect the tester's X and Y outputs to the oscilloscope's X and Y inputs, respectively. Ensure the oscilloscope is in X-Y mode.

3.3 Powering the Device

Connect the provided power adapter to the DC input jack on the VI Curve Tester and then plug it into a suitable power outlet. The power indicator light (if present) should illuminate.

3.4 Front Panel Overview

Familiarize yourself with the controls on your specific model:

Front panel of ASA NI-210G VI Curve Tester
Figure 3.4.1: Front Panel of NI-210G Model. Features voltage selection (0.6V, 4V, 8V, 16V), frequency selection (60Hz, 400Hz, 2000Hz, SCAN), and channel selection (A, A+B, Pulse).
Front panel of ASA NI-210SJ VI Curve Tester
Figure 3.4.2: Front Panel of NI-210SJ Model. Features voltage selection (LOW, MED1, MED2, HIGH), channel selection (A, B), and a rotary knob for adjustment.
Front panel of ASA NI-210SS VI Curve Tester
Figure 3.4.3: Front Panel of NI-210SS Model. Features voltage selection (LOW, MED1, MED2, HIGH), channel selection (A, B), and two rotary knobs for adjustment.

Common controls across models include:

  • Voltage Selection (LOW, MED1, MED2, HIGH or 0.6V, 4V, 8V, 16V): Selects the peak voltage applied to the component under test. Start with LOW for sensitive components.
  • Frequency Selection (e.g., 60Hz, 400Hz, 2000Hz, SCAN): Adjusts the test signal frequency. Higher frequencies are useful for testing capacitors and inductors. SCAN mode may cycle through frequencies.
  • Channel Selection (A, B, A+B, Pulse): Selects which test channel(s) are active. 'A' and 'B' are typically for individual component testing, 'A+B' for comparison, and 'Pulse' for specific component types.
  • Test Terminals (A, COM, B, G): Connect your test probes here. 'A' and 'B' are the signal outputs, 'COM' is the common ground, and 'G' might be an additional ground or reference.

4. Operating Instructions

4.1 Basic Component Testing

To test a component or a point on a circuit board:

  1. Ensure the circuit board is unpowered.
  2. Connect the VI Curve Tester to your oscilloscope as described in Section 3.2.
  3. Select an appropriate voltage and frequency setting on the VI Curve Tester. Start with LOW voltage and a moderate frequency (e.g., 400Hz).
  4. Connect the test probes to the component or points on the circuit board you wish to test. Typically, one probe to 'A' (or 'B') and the other to 'COM'.
  5. Observe the VI curve displayed on the oscilloscope. Compare it to known good curves or the reference curves provided below.

4.2 Interpreting VI Curves

Different electronic components exhibit distinct VI curve patterns. Understanding these patterns is key to diagnosing faults.

VI Curve patterns for basic components
Figure 4.2.1: Basic VI Curve Patterns. Shows characteristic curves for Resistors (straight line), Capacitors (ellipse), Diodes (L-shape), Transistors, and MOSFETs.
Detailed VI Curve patterns for various components
Figure 4.2.2: Detailed VI Curve Patterns. Illustrates curves for NPN/PNP transistors, N/P-channel MOSFETs, Resistors, Capacitors, Diodes, Zener Diodes, and SCRs. These patterns help identify component types and their health.
Table 4.2.1: Common VI Curve Interpretations
Component TypeCharacteristic CurveFault Indication
ResistorStraight line through origin (slope indicates resistance).Open circuit (horizontal line), Short circuit (vertical line), Incorrect resistance (wrong slope).
CapacitorEllipse (shape and size indicate capacitance and frequency).Open circuit (horizontal line), Short circuit (vertical line), Leakage (distorted ellipse).
DiodeL-shaped curve (conducts in one direction, blocks in reverse).Open (horizontal line), Short (vertical line), Leaky (rounded knee, conduction in reverse).
Transistor (BJT/MOSFET)Complex curves, often showing multiple segments or "steps" when testing junctions.Open junctions, shorted junctions, leakage, incorrect gain characteristics.

4.3 Using the VI Test Board (Accessory)

The VI Test Board is an excellent tool for learning and practicing VI curve interpretation. It contains various common components with switches to connect them for testing.

VI Test Board accessory
Figure 4.3.1: VI Test Board. This accessory features various components like transistors, resistors, capacitors, and diodes with switches for easy testing and learning.
  1. Connect the 'Ain' terminal of the VI Test Board to the 'A' (or 'B') terminal of the VI Curve Tester.
  2. Connect the 'COM' terminal of the VI Test Board to the 'COM' terminal of the VI Curve Tester.
  3. Select a component on the VI Test Board using its corresponding switch.
  4. Observe the resulting VI curve on the oscilloscope and compare it to the theoretical curves or the diagrams in Section 4.2.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Cable Care: Inspect test leads and BNC cables regularly for damage. Replace any frayed or broken cables immediately.

6. Troubleshooting

Table 6.1: Common Troubleshooting Scenarios
ProblemPossible CauseSolution
No curve displayed on oscilloscope.
  • Oscilloscope not in X-Y mode.
  • Incorrect BNC cable connection.
  • Oscilloscope sensitivity too low/high.
  • VI Curve Tester not powered on.
  • Open circuit in test leads or component.
  • Set oscilloscope to X-Y mode.
  • Verify X and Y connections.
  • Adjust oscilloscope's V/div and Time/div (or X-Y gain).
  • Check power connection and indicator.
  • Check continuity of test leads and component.
Distorted or unstable curve.
  • Interference from live circuits.
  • Poor contact with test probes.
  • Faulty component.
  • Incorrect frequency/voltage setting.
  • Ensure circuit is unpowered.
  • Ensure firm contact with test points.
  • Compare with a known good component.
  • Adjust frequency and voltage settings.
Curve is too small or too large.
  • Oscilloscope sensitivity settings.
  • VI Curve Tester voltage setting.
  • Adjust oscilloscope's V/div for both X and Y channels.
  • Adjust the voltage level on the VI Curve Tester.

7. Specifications

Specifications may vary slightly between models (NI-210G, NI-210SJ, NI-210SS). Refer to your specific model's labeling for precise details.

Table 7.1: General Specifications (Typical)
FeatureDescription
Input Voltage LevelsMultiple selectable levels (e.g., 0.6V, 4V, 8V, 16V or LOW, MED1, MED2, HIGH)
Test FrequenciesMultiple selectable frequencies (e.g., 60Hz, 400Hz, 2000Hz) and SCAN mode
ChannelsSingle or Dual Channel (A, B, A+B, Pulse options)
Output ConnectorsBNC (for oscilloscope X-Y inputs)
Test TerminalsBanana jacks (A, COM, B, G)
MaterialPlastic casing
Dimensions (Approx.)Varies by model, compact handheld size.
Weight (Approx.)0.3 kg (main unit)

8. User Tips

  • Clarify Your Order: When purchasing, ensure you select the correct model (NI-210G, NI-210SJ, NI-210SS) or accessories (like the VI Test Board) to match your intended use. Some listings may show different products or accessories in the same image gallery.
  • Start with Known Good Components: Before testing a faulty circuit, practice with known good components (e.g., using the VI Test Board) to familiarize yourself with their characteristic curves. This helps in identifying anomalies on a suspect board.
  • Compare with a Reference Board: For complex circuit boards, having a known good board to compare VI curves against is the most effective troubleshooting method. Test corresponding points on both boards and look for discrepancies in the curves.
  • Adjust Oscilloscope Settings: Don't forget to adjust the oscilloscope's vertical and horizontal sensitivity (V/div) to get a clear, centered, and appropriately scaled curve.

9. Warranty and Support

The manufacturer provides a warranty for this product:

  • New Products: 6 months warranty.
  • Used Products: 30 days warranty.

For technical support or warranty claims, please contact your seller or the manufacturer directly. Ensure you have your purchase details and product model information ready.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.