1. Product Overview and Function
1.1 Function
The Sunster Diesel Air Heater is designed to prevent damage to vehicles caused by sudden temperature drops. It improves the interior temperature of the vehicle and preheats the engine coolant to prevent engine wear at low temperatures. This system is conducive to thawing the car interior, assisting car starts, and defrosting car glass.
1.2 Key Features
- Low Consumption and Quiet Operation: Consumes approximately 1 gallon of fuel per night, capable of heating up to 20 m² (215-269 ft²), with noise levels ≤75dB.
- Timer Function: Equipped with a 24-hour off clock, allowing users to set desired heating times.
- Dual Control Methods: Features both an LCD control panel and a remote control for convenient operation.
- Rapid Heating: Achieves a warm environment within 10 minutes, heating areas between 215-269 ft² (20-25 m²).
- Durable Aluminum Housing: Ensures uniform heat dissipation and rapid heating. An intelligent overheat sensor prevents the heater from overheating and burning out.
Video: Sunster Diesel Air Heater product showcase, demonstrating features and components.

Image: Intelligent LCD Panel and Remote Control for Sunster Diesel Air Heater, showing 24-hour timing, energy conservation, temperature/gear regulation, and language switching.

Image: Enhanced safety features including visible fuel tank capacity, terminal design, leak-proof fuel cap, and upgraded hot air outlet duct.

Image: Sunster Diesel Air Heater demonstrating 10-minute rapid heating to 35°C with an upgraded aluminum body.

Image: Sunster Diesel Air Heater highlighting UL, FCC, and CE certifications, and silent oil pump for noise reduction (less than 75dB).
2. Technical Specifications
| Attribute | Value |
|---|---|
| Brand Name | Sunster |
| Model | ALL IN ONE |
| Item Type | Heating & Fans |
| Fuel | Diesel |
| Heater Power | 8kw |
| Supply Voltage | DC12v/24v |
| Tank Capacity | 5L/1.3 gal |
| Fuel Consumption | 0.11-0.45 (L/H) |
| Applicable Range | 215-269ft²/20-25m² |
| Adjustable Temp. Range | 46℉-95℉/8℃-35℃ |
| Heater Working Temperature | -40℃~+20℃/-40℉~+68℉ |
| Oil Pump Working Temperature | -40℃~+20℃/-40℉~+68℉ |
| Control Method | LCD+Remote Control |
| Switch Type | LCD Switch |
| Noise Level | <75db |
| Item Length | 38cm |
| Item Width | 25.5cm |
| Item Height | 27.5cm |
| Item Weight | 5 kg |
| Air Outlet Pipe Diameter | 76mm |
| Intake Pipe Diameter | 25mm |
| Exhaust Pipe Diameter | 25mm |
| Certifications | RoHS, FCC, CE |
| Applicable Vehicles | Trucks, ships, car trailers, RVs, campers, caravans, and all other diesel vehicles |

Image: Diagram showing the dimensions and key components of the Sunster Diesel Air Heater, including the LCD switch, air filter, pipes, remote control, and silencer.
3. Package Contents
The package includes the following items:
- 1 x All-in-one Diesel Heater (with LCD)
- 1 x Battery power cord
- 1 x Remote Control
- 1 x Silencer
- 1 x Air Filter
- 1 x Inlet Pipe
- 1 x Outlet Pipe
- 1 x Exhaust Pipe
- 1 x Air outlet Pipe
- 1 x Screw & fixture accessories set
- 1 x User Manual

Image: The Sunster Diesel Air Heater unit along with all included accessories such as the LCD switch, remote control, silencer, air filter, and various pipes and cables.
4. Installation Guide
4.1 Internal Structure
Understanding the internal components is crucial for proper installation and maintenance.

Image: Exploded view diagram of the heater's internal structure, showing the control box, ignition plug, combustion chamber, heating zone, air inlet, air fan, flame retardant impeller, air outlet, and safety plug.
4.2 Installation Position
The heater can be installed in various positions depending on the vehicle type. The main unit is typically installed in the passenger room or baggage room. If internal installation is not feasible, it can be fixed under the vehicle, ensuring protection from splashing.
- Truck: On the co-driver's legroom, on the back wall of the cab, driver's seat backrest, or within the tool box.
- RV: In front of the passenger seat, between the driver seat and passenger seat, under the container, or in the trunk.
- 5 Seater/7 Seater: Mainly in the passenger room or baggage room. If not possible, fix under the vehicle, but beware of splashing.
- Excavator: Inside the driver's seat, on the back wall of the cab, or inside the protection box.

Image: Diagrams illustrating recommended installation positions for the heater in various vehicle types: Truck, RV, 5/7 Seater, and Excavator.
4.3 Installation Diagram
Refer to the diagram for detailed connection points of the parking heater components.

Image: Detailed installation diagram showing the connections for the control switch, main equipment (air inlet/outlet), fuel pump, filter, fuel tank, exhaust pipe, and associated clamps and gaskets.
5. Operating Instructions
5.1 Control Panel and Remote Control Types
The heater supports various control panel and remote control configurations. Identify your specific model for correct operation.

Image: Overview of different LCD switch models (S-A2013, S-A2173, S-A2174, S-A2172, S-A2171, S-A2017, S-A2019, S-A2170, S-A2018, S-A2018G) and their corresponding remote controls and battery types.
5.2 S-A2013 Wireless Remote Control Operation
This model features a color LCD screen, 24-hour timing, temperature/gear regulation, and language switching (German, English, Russian).
- Run Mode Declaration: The heater has manual output power mode and automatic constant temperature mode. In automatic mode, the heater adjusts output power based on temperature difference. Manual mode allows power adjustment from Level 1-8. Automatic mode temperature setting is 8-36°C.
- Turn ON/OFF: Click the ON/OFF Key.
- Change Run Mode: Click the MODE Key to cycle between manual and automatic modes.
- Output Power/Temperature Adjustment: Use UP and DOWN keys to adjust power level in manual mode or set temperature in automatic mode.
- Remote Controller Authorization: Press UP key >3s until "rte" displays, release UP key, then click any key on the remote. Display returning to normal indicates success.
- Manual Fuel Pumping: While heater is OFF, press PUMPING Key >8s until pump logo and "300" display. Release key, pump starts. Display shows remaining time. Click ON/OFF to halt. Do not over-pump fuel.
- Timing On-Off: After setting working time, press confirm to enter timing on-offsetting. Use UP key to enter ON state. Set first and second groups of turn on/off times. Alarm clock icon lights up if successful.
- Temperature Control Mode Switch: In unset state, press UP key, hold, and press confirm. "P-x.x" (pump capacity) indicates manual temperature control. "xx°C" indicates auto temperature control. Auto mode allows maximum pump oil volume, manual mode is limited.
5.3 S-A2173-A2174-A2018-A2018G Wireless Remote Control Operation
- Key Function:
- Set: Enter set state to adjust parameters, change working state.
- Confirm: In set state, confirm current set point, enter next parameter setting. In unset state, check status.
- Up Regulation: In set state, adjust parameter. In unset state, set operating temperature.
- On-off: Short press to turn on (status light always on). Long press 2 seconds to turn off (status light flickers).
- Down Regulation: In set state, adjust parameter. In unset state, set operating temperature.
- Match Code: In unset state, press up-regulation button and confirm button simultaneously for >3 seconds to enter match code interface. Press ON button on remote to send code. Exit after successful match.
- Parameter Setup: Press SET button to enter. Icons on display will light up.
- Time Setting: Use UP/DOWN to adjust hour/minute, confirm with SET.
- Timing On-Off Setting: Defaults to OFF. Use UP to turn ON. Set first and second groups of on/off times.
- Manage Password Input: Use UP/DOWN to enter correct 4-digit password, confirm with SET.
- Pump Capacity Setting: Use UP/DOWN to change minimum/maximum pump capacity, confirm with SET.
- Fans' Rotational Speed Setting: Use UP/DOWN to change minimum/maximum speed, confirm with SET.
- Operating Voltage Setting: In OFF state, use UP/DOWN to select 12V (U-12) or 24V (U-24).
- Speed Signals Setting: Use UP/DOWN to set speed signals (1 for opposite polarity/single magnet, 2 for same polarity). Incorrect setting leads to speed difference.
- Change Manage Password: If OFF, no change needed. If ON, input new 4-digit password. Confirm to save.
- Query Machine State: Time, Temperature, Set Temperature/Pump Capacity, Historical Fault Code, Voltage.
- Manual Fuel Refueling: In unset state, press DOWN, hold, and press confirm. Enter interface. Press UP to turn on pump. Press DOWN/SET to turn off.
- Timing On-Off: After setting working time, press confirm to enter. Defaults to OFF. Set first/second groups.
- Temperature Control Mode Switch: In unset state, press UP, hold, and press confirm. "P-x.x" for manual, "xx°C" for auto.
5.4 S-A2170 Wireless Remote Control Operation
- Button Introduction:
- On/Off: Long press to turn on/off.
- Lighting Instructions: Light under switch button indicates ON. Flashing indicates fault.
- Power On: Long press to turn on/off when working voltage is met.
- Manual Fuel Filling: In shutdown state, press on/off button 5 times quickly to start oil pump. After air is exhausted, press on/off key to stop. Observe to avoid over-pumping.
- Remote Control Pairing: In power-on state, press on/off button 5 times. Indicator light flashes, entering pairing state. Press power + setting button on remote to start pairing. Wait for automatic pairing.
6. Troubleshooting Guide
6.1 Error Code Display (E-Codes)
The LCD display will show specific error codes if a malfunction occurs. Refer to the table below for code descriptions and solutions.
| Panel Display | Cause of Issue | Solution |
|---|---|---|
| E-01 | 12V model: voltage higher than 18V/lower than 10V | Check the power supply voltage, external power supply. |
| E-02 | 24V model: voltage higher than 32V/lower than 20V | Check the power supply voltage, external power supply. |
| E-03 | Glow plug short circuit/open circuit | 1. Glow plug is short-circuited or connection wire is reversed. 2. Insulation damage at tail of glow plug causes short circuit. 3. Leakage of glow plug. 4. Poor contact of glow plug connector. 5. Glow plug is burned out and replaced. |
| E-04 | Oil pump short circuit/open circuit | 1. Oil pump is not connected properly, connection line is short-circuited or disconnected. 2. Pin socket control board is not firmly inserted. 3. Oil pump circuit is disconnected. |
| E-05 | High shell temperature (>260°C) | 1. Machine's air circulation is obstructed, air inlet/outlet blocked, air duct blocked. 2. Installation space is too narrow. 3. Oil pump with large amount of oil is connected incorrectly. 4. Oil leaking from one-way valve of oil pump. 5. Sensor is damaged. |
| E-06 | Fan short circuit/open circuit/magnet too far from Hall sensor | 1. Motor fan blade is stuck/carton. 2. Adjust gap between wind wheel and main board. 3. Motor failure/replacement of main board. 4. Motor socket is not plugged in properly. |
| E-07 | Controller detected wiring harness connection failure | Check wiring, connectors. |
| E-08 | Flame extinguished | 1. Oil tank is short of oil, oil pump abnormal, oil quality problematic. 2. Oil circuit leaking or bubbles in old oil circuit, oil supply not continuous. 3. Intake and exhaust pipes are blocked. |
| E-09 | Case sensor short circuit/open circuit | Replace the temperature sensor, or the connector is in poor contact. |
| E-10 | Ignition failure (failed to start/form flame) | 1. Fuel tank is short of fuel or exhausted. 2. Oil pump is stuck or abnormal. 3. Oil circuit is correct, no bubbles, oil supply continuous. 4. Poor power supply, oil problem. |
6.2 Machine Malfunction Status (S-A2170)
For the S-A2170 model, the indicator light flashes to signal specific malfunctions:
| Machine Malfunction | Status Display | Approach |
|---|---|---|
| Power supply undervoltage | Indicator light flashes once | Increase the supply voltage |
| Power supply overvoltage | Indicator light flashes twice | Reduce the supply voltage |
| Glow plug failure | Indicator light flashes 3 times | Check if the ignition plug is open or short-circuited |
| Oil pump failure | Indicator light flashes 4 times | Check if the oil pump is disconnected or short-circuited |
| Machine overheating | Indicator light flashes 5 times | Check the temperature sensor on the housing or whether the fan speed is abnormal. |
| Motor failure | Indicator light flashes 6 times | Check magnet polarity, Hall sensor position, or loose terminals. |
| Disconnection failure | Indicator light flashes 7 times | Check the panel connection plug, the blue harness is loose or broken. |
| Flame extinguished | Indicator light flashes 8 times | Check whether there is air or blockage in the oil circuit, check whether the temperature sensor on the housing is faulty, or the connector terminal is loose. |
| Sensor failure | Indicator light flashes 9 times | Check if the sensor plug is loose, broken or short-circuited. |
| Ignition failure | Indicator light flashes 10 times | Check whether the oil line is blocked, or the oil is not flowing smoothly, the oil pump is stuck, the evaporation network is blocked due to oil quality problems, etc., causing the 2 ignitions to fail to burn normally. |
7. User Tips
- Fuel Consumption: The heater consumes between 0.11 to 0.45 liters per hour, which translates to approximately 1 gallon per night for continuous operation.
- Pre-heating: Utilize the 24-hour timing function to pre-heat your vehicle before use, ensuring a warm environment upon entry.
- Noise Reduction: Ensure the silencer is properly installed to maintain the low noise operation (<75dB).
8. Support and Contact
8.1 Contact Information
For any questions or support regarding your Sunster product, please contact us via email:
Email: sunster202@163.com
We are committed to providing prompt assistance and resolving any issues you may encounter.
8.2 User Manual PDF
A comprehensive user manual in PDF format is available for detailed instructions and diagrams. You can access it here: Sunster Wireless Heater User Manual (PDF).