1. Product Overview
The YIERYI Soil Multi-Parameter Sensor is an advanced 8-in-1 device designed for comprehensive soil analysis. It accurately measures soil pH, electrical conductivity (EC), salinity, nitrogen (N), phosphorus (P), potassium (K), temperature, and moisture content. This sensor is ideal for various applications including water-saving agricultural irrigation, meteorological monitoring, greenhouse cultivation, flower and vegetable growing, grassland and pasture management, rapid soil testing, and scientific experiments.
The sensor features a compact design, high measurement accuracy, fast response speed, and good interchangeability. Its robust IP68 waterproof and anti-corrosion design, utilizing 316L stainless steel probes and epoxy resin sealing, ensures stable performance and long-term durability in harsh outdoor conditions.

2. Specifications
| Parameter | Value/Range | Resolution | Accuracy |
|---|---|---|---|
| Model Number | THE01888-RS485 | ||
| Brand Name | yieryi | ||
| Is Smart Device | Yes | ||
| Battery Included | No | ||
| With Backlight | No | ||
| Origin | Mainland China | ||
| Display Type | Analog | ||
| Certification | CE | ||
| Soil Temperature | -40 ~ 80°C | 0.1°C | ±0.3°C (25°C) |
| Soil Moisture | 0-100% (m³/m³) | 0.1% | ±3% |
| Soil EC | 0-20000 µS/cm | 10 µS/cm | ±3% |
| Soil Salinity | 0-20000 mg/L | 1 mg/L | ±3% |
| Soil NPK | 0-1999 mg/kg | 1 mg/kg | ±3% |
| Soil pH | 3-10 PH | 0.1 | ±0.2 |
| Protection Grade | IP68 | ||
| Probe Material | Temp, humidity, conductivity, and anti-corrosion special electrodes (316L stainless steel) | ||
| Sealing Material | Black flame retardant epoxy resin | ||
| Default Cable Length | 2m (customizable up to 1200m) | ||
| External Dimensions | 46mm x 16mm x 128mm (sensor body) | ||
| Output Signal | RS485 interface (Standard Modbus RTU protocol, default device address: 01) or USB interface (depending on model) | ||
| Power Supply | DC 5V (USB version) / 12-24V DC (RS485 version) | ||
| Max Power Consumption | 0.5W | ||
| Operation Temperature | -20°C ~ +60°C | ||
| Stability Time | ≤5 minutes | ||
| Response Time | <1 second | ||



3. Setup
3.1. Connection Types
The sensor is available in two main versions: RS485 and USB. The RS485 version supports industrial-grade connections for long-distance data transfer, while the USB version offers direct connection to mobile devices or computers.
3.1.1. RS485 Connection
The RS485 sensor uses the standard Modbus-RTU protocol for communication. It can be connected to various devices such as PLCs (Programmable Logic Controllers), microcontrollers, or PCs via an RS485 to USB converter.

Wiring Method for RS485:
- Red line: Power+
- Yellow line: RS485A
- Green line: RS485B
- Black line: Power-


3.1.2. USB Connection
The USB version of the sensor allows direct connection to compatible mobile phones (Android and HarmonyOS) or computers for real-time data monitoring. Please note that the USB version does not support RS485 communication.

3.2. Software Setup (for USB version and PC monitoring)
For real-time monitoring, you can use dedicated software on your computer or a mobile application on your smartphone.
3.2.1. Mobile APP Installation
Scan the QR code provided on the product packaging or in the manual to download the mobile application. The APP is suitable for Android and HarmonyOS systems. It is not compatible with iOS systems and some low-end OPPO phones.

Installation Notes:
- If there is system interception during the installation process, you may need to adjust phone settings (e.g., turn off pure mode, allow single installation authorization, allow this installation, turn off security protection).
- During installation, some systems may require an interception password. If you forget it, please reset it via SMS.
3.2.2. PC Software Setup (for RS485 version with USB converter)
The device can be uploaded to the customer's own upper computer software through a 485 to USB template conversion for real-time monitoring. Use the sensor configuration tool provided by the manufacturer for configuration and testing (only one device can be connected when using this configuration software).

4. Operating Instructions
4.1. Measurement Methods
There are two primary methods for using the sensor to measure soil parameters:
4.1.1. Rapid Measurement Method
Select a suitable measurement location, avoiding rocks and similar hard objects. Excavate the surface soil according to the required measurement depth, maintaining the original looseness of the soil below. Grip the sensor tightly, insert it vertically into the soil, and do not shake it left or right during insertion. It is recommended to calculate the average of multiple measurements within a small range for one measurement point.
4.1.2. Buried Surveying Method
Dig a pit with a diameter greater than 20cm vertically, and insert the sensor steel needle into the pit according to the measurement needs. Fill and compact the pit to ensure the steel needle is in close contact with the soil. After the sensor stabilizes for a period of time, continuous long-term measurement and recording can be carried out.

4.2. Data Viewing and Export
The sensor allows for real-time data viewing and export through various platforms.
4.2.1. Mobile APP Data Monitoring
Connect the USB version sensor to your compatible mobile phone. The mobile app provides a user-friendly interface to view real-time data on various soil elements. It supports multiple viewing modes and is easy to operate.

4.2.2. Cloud Platform Monitoring
For remote monitoring, the device can be uploaded to a free cloud platform through a network collector (which can monitor 8 elements) or an environmental monitoring host (which can monitor 32 elements). This allows for remote real-time monitoring of soil conditions via mobile phones, computers, and tablets.

4.2.3. Data Storage and Export
The mobile application supports data export, allowing you to save current real-time data locally on your phone, typically in formats like Excel.

5. Maintenance
5.1. General Precautions
- Read this manual thoroughly before use.
- Do not attempt to insert the probe into stones or hard soil clumps, as this may damage the probe.
- When removing the sensor from the soil, do not pull directly on the cable.
- The sensor probe should be inserted fully into the soil/substrate to reduce operational errors and improve measurement accuracy.
- Avoid direct exposure of the transmitter to strong sunlight, which may cause excessive temperature. Pay attention to lightning protection when using outdoors.
- When measuring parameters such as pH, conductivity, phosphorus, and potassium, it is necessary to keep the soil moist (at least 20%).
- After inserting the sensor into the soil, it cannot immediately read the value. The value can only be read after it stabilizes. The waiting time varies for different soils, and the data can only be read after it stabilizes after being inserted into the soil for about 3-5 minutes.
- Among the 4 probes, one probe has a dark color, which belongs to a special alloy and is prone to wear and tear. After use, the probe should be cleaned thoroughly.

5.2. Cleaning and Storage
After each use, especially when measuring in different soil types, thoroughly clean the probes with a soft cloth to remove any soil residue. This prevents cross-contamination and ensures accurate readings for future measurements. Store the sensor in a dry, clean environment away from extreme temperatures.
5.3. Durability Features
The sensor is designed with high-density epoxy resin for vacuum sealing between the probe and the body. This prevents moisture from entering the interior and ensures good sealing performance, contributing to its IP68 waterproof and dustproof rating.

6. Troubleshooting
- Nitrogen (N) value shows 0: This can happen when the soil is too dry. Add some water to the soil and measure again for accurate readings.
- Forgotten RS485 Sensor Address: If you forget the original address of an RS485 sensor, you can use the broadcast address
0XFEinstead. When using0XFE, the host can only connect to one slave device, and the return address remains the original address, which can be used as a method for address query. - No Data Return (RS485): Ensure the sensor receives the correct data. If the sensor receives correct data, it will return it via the original path. Check wiring and communication settings (baud rate: 9600; parity bit: none; data bits: 8; stop bits: 1).
- USB Sensor Not Connecting to iOS: The USB version of the soil meter only supports Android and HarmonyOS systems, not iOS systems or some low-end OPPO phones. This is a compatibility limitation.
7. User Tips
- For best NPK readings, ensure the soil is adequately moist. Dry soil can lead to inaccurate or zero readings for certain parameters.
- Always insert the probes gently and vertically to avoid bending or damaging them.
- After each use, especially when moving between different measurement areas, clean the probes thoroughly to maintain accuracy and prevent contamination.
- Allow the sensor sufficient stabilization time (3-5 minutes) after insertion before taking readings to ensure accuracy.
- When using the RS485 version with multiple sensors, ensure each sensor has a unique address to avoid communication conflicts.
8. Warranty and Support
For detailed guides, technical support, and warranty information, please refer to the official user manual PDF. This document provides comprehensive information on product usage, maintenance, and troubleshooting.
A PDF version of the user manual is available for download: View User Manual (PDF)