RuoShui 328B

Contents

User Manual for RuoShui Victor 328B Type-C Infrared Thermal Imager

Version 1.0

1. Product Overview

The mobile phone infrared thermal imager is a portable infrared thermal imaging analyzer designed for high precision and quick response. It incorporates an industrial-grade infrared detector with small pixel spacing and high resolution. Equipped with a 3.2mm lens, this device is lightweight and portable, allowing direct plug-and-play operation. When connected to a mobile phone via its customized professional thermal image analysis APP, it enables multi-mode professional thermal image analysis of target objects anytime and anywhere.

RuoShui Victor 328B Thermal Imager
Figure 1: RuoShui Victor 328B Type-C Infrared Thermal Imager.

2. Product Characteristics

  • High-quality optical lens and high-resolution detector for excellent imaging effect.
  • Lightweight and portable, enabling professional thermal imaging analysis via mobile APP.
  • Wide temperature measurement range: -15°C to 600°C.
  • Supports high temperature alarm and customized alarm threshold.
  • Displays user-defined temperature range screens, with various scenarios for high-temperature regions.
  • Supports high and low temperature tracking.
  • Allows adding points, lines, and rectangular boxes for regional temperature measurement, with tracking and alarm features for lines and boxes.
  • Features a durable aluminum alloy shell.
Software Function (APP) Description
Figure 2: Key features and software functions of the mobile thermal imager APP.

3. Specifications

Feature328B Type328A Type
Resolution256x192160x120
Wavelength8-14 μm
Frame rate25Hz
NETD<50mK @25°C
FOV56° x 42°35°X27°
Lens3.2mm
Temperature measurement range-15°C ~ 600°C
Temperature measurement accuracy± 2°C or ± 2%
Temperature measurementHighest, lowest, central point and area temperature measurement are supported
Color paletteIron, white hot, black hot, rainbow, red hot, cold blue
LanguageEnglish
Working temperature-10°C - 75°C
Storage temperature-45°C - 85°C
IP ratingIP54
Dimensions34mm x 26.5mm x 15mm
Net weight19g
Battery IncludedNo
High-concerned chemicalNone
Is Smart DeviceNo
StyleEmbedded
OriginMainland China
CertificationCE, RoHS
Mobile Phone Plug-in Thermal Imager App Features
Figure 3: Key features of the mobile thermal imager and its APP.

4. Setup

4.1 Hardware Appearance and Part Name

Thermal Imager Hardware Diagram
Figure 4: Hardware components of the thermal imager, showing the lens and USB Type-C connector.

The thermal imager features a lens for capturing infrared data and a USB Type-C connector for interfacing with compatible mobile devices.

4.2 Application Installation

  1. Download and Install: Scan the QR code provided on the product packaging box to download and install the dedicated thermal imaging APP.
  2. Startup Settings: Insert the thermal imager into the Type-C port of your mobile phone. Ensure the OTG function is enabled in your mobile phone settings. (Some mobile phones may have OTG enabled by default.)
  3. Software Start: Launch the installed thermal imaging APP.
Application Installation Steps
Figure 5: Visual guide for APP installation and initial setup.

5. Operating Instructions

5.1 User Interface Introduction

After connecting the device to an Android phone or tablet and running the APP, you will see the main interface. This interface provides various controls and displays for thermal imaging analysis.

APP User Interface Overview
Figure 6: Overview of the APP's main user interface.
No.FunctionDescription
1SettingProvides APP interface and parameter settings for the infrared thermal imaging camera.
2AboutDisplays information about the APP.
3ResetResets all information on the screen and restores the APP to its startup state.
4Photo TakingTakes photos and stores them in the Album.
5Video RecordingRecords videos and stores them in the Album.
6AlbumStores and allows viewing of photos and videos.
7Infrared thermal imagingDisplays the infrared thermal imaging feed.
8Temperature color barDisplays maximum and minimum temperatures with color block bars.
9Color paletteSwitches between different color palettes.
10Regional Temperature MeasurementAdds points, lines, and boxes for temperature measurement in different regions.
11Temperature TrackingTracks current maximum, minimum, and center point temperatures.
12Highlight Rectangle TemperatureHighlights current temperature in all rectangular boxes. Automatically adds a rectangle if none exist.
13High Temperature AlarmSets high temperature alarm threshold. Triggers sound and screen alarm if threshold is exceeded.
14Highlight High-temperature RegionsDisplays the maximum-temperature region on the screen.

5.2 Function Details

5.2.1 Settings

Click the [Settings] button (labeled '1' in Figure 6) to access the settings panel. Here you can configure various parameters for the thermal imager.

APP Settings Panel
Figure 7: The APP's settings panel.
CategorySettingDescription
GeneralLanguageEnglish
Temperature UnitCelsius (°C), Fahrenheit (°F), and Kelvin (K) are supported.
Record with AudioChoose whether to record sound during video recording.
High and Low TEMP. SwitchSelect between low temperature range (-15°C to 120°C) and high temperature range (120°C to 600°C).
Thermal ParametersEmissivityParameter values (0.01-1.00) should be set according to the measured target.
Humidity (%)Parameter values should be set according to the humidity of the test environment.
Correction (°C)Correction parameters should be set according to temperature measurement deviation.
App VersionDisplays the current APP version (e.g., 1.0.2) with an option to upgrade.

5.2.2 About

The "About" section provides information regarding the APP and the manufacturer. You can find details such as the company name, website, and contact information.

5.2.3 Interface Reset

Clicking the [Reset] button (labeled '3' in Figure 6) will reset the APP interface and all settings to their default startup state.

5.2.4 Photo Taking

To capture the current infrared screen, click the [Photo Taking] button (labeled '4' in Figure 6). The captured image will be saved to the Album.

APP Photo Taking Interface
Figure 8: The APP interface during photo capture.

5.2.5 Video Recording

Click the [Video Recording] button (labeled '5' in Figure 6) to start recording a video. The button will turn red, and the recording time will be displayed in the lower-left corner of the video window. Click the button again to stop recording.

5.2.6 Album

All photos and videos captured by the APP can be viewed in the [Album] section (labeled '6' in Figure 6). Files are arranged in chronological descending order.

APP Album Interface
Figure 9: The APP's album interface displaying captured media.
  • **Album**: Displays both photos and video files.
  • **Photo**: Displays only photo files.
  • **Video**: Displays only video files.
  • **Trash**: Allows selection and deletion of files.

5.2.7 Color Palette

The APP offers 6 display modes for the color palette, allowing you to visualize thermal data in different ways.

APP Color Palette Options
Figure 10: Available color palette options in the APP.
  • **Iron**: Red indicates maximum temperature, yellow for medium, and blue/black for low temperatures. Suitable for scenarios with distinct temperature differences.
  • **White hot**: High-temperature areas are white, transitioning to black. Ideal for traditional black-and-white thermal imaging.
  • **Black hot**: High-temperature areas are black, transitioning to white. Another option for traditional black-and-white thermal imaging.
  • **Rainbow**: Uses a spectrum of colors (red, yellow, blue, black) to represent temperature ranges, suitable for general high and low temperature visualization.
  • **Red heat**: Main colors are red and black, with a transition from black to white to red from minimum to maximum temperature. Focuses on high-temperature states.
  • **Cold blue**: Blue marks colder regions, useful for observing low-temperature targets.

Adjusting the color palette bar on the right side of the screen allows you to modify the temperature range displayed, making specific regions more prominent.

5.2.8 Regional Temperature Measurement

Click the [Regional Temperature Measurement] button (labeled '10' in Figure 6) to add points, lines, or rectangular boxes for temperature measurement. Lines and rectangular boxes will display real-time maximum and minimum temperatures within their regions. Long-press a region to adjust its size and position, or click the trash icon to delete it.

Regional Temperature Measurement Interface
Figure 11: Interface for regional temperature measurement.

5.2.9 Temperature Tracking

Click the temperature tracking button (labeled '11' in Figure 6) to enable or disable the measurement of maximum, minimum, and center point temperatures on the screen. Red indicates the maximum temperature, blue the minimum, and yellow the center point. Click once to turn on, and again to turn off.

5.2.10 Highlight Rectangle Temperature

This function highlights the current temperature within all rectangular boxes. If no rectangular box exists, one will be automatically added in the default position. Long-press a rectangular box to adjust its size and position. Click the delete icon next to it to remove the box.

Highlight Rectangle Temperature Interface
Figure 12: Highlighting temperature within a rectangular region.

5.2.11 High Temperature Alarm

Click the switch icon for [High Temperature Alarm] (labeled '13' in Figure 6) to set a high temperature alarm threshold. If the maximum temperature on the screen (or within a measured region, excluding point measurements) exceeds this threshold, the system will sound an alarm and the video screen will flash red.

High Temperature Alarm Setting
Figure 13: Setting the high temperature alarm threshold.

5.2.12 Highlight High-temperature Regions

In this mode (labeled '14' in Figure 6), high-temperature regions are displayed using the current color palette, while other regions appear as white hot. The temperature range can be adjusted using the slider on the right side of the color board bar. This mode is useful for applications focusing specifically on high-temperature values.

Highlight High-temperature Regions Interface
Figure 14: Display mode highlighting high-temperature regions.

6. Maintenance

6.1 Precautions for Use and Maintenance

  • Do not use alcohol, detergent, or other organic cleaners to clean the lens, as this will damage the lens coating.
  • Avoid directing sunlight, laser, or other strong light sources directly onto the lens. This can cause irreparable physical damage to the thermal imager.
  • Ensure the OTG (On-The-Go) feature is enabled in your mobile phone settings for the APP to function correctly. Search for "OTG" in your phone's settings; some phones enable it by default.

7. Troubleshooting

If you encounter issues with your thermal imager, please refer to the following common troubleshooting steps:

  • **Device not recognized**: Ensure OTG is enabled in your phone settings. Try restarting the phone and reconnecting the imager.
  • **App not displaying thermal image**: Check if the imager is securely connected to the Type-C port. Verify that the APP has necessary permissions (e.g., camera access).
  • **Inaccurate temperature readings**: Calibrate the emissivity and humidity settings in the APP according to the material being measured and the environment. Refer to the "Table of Reflectivity of Common Materials" in the Appendix.
  • **App crashes or freezes**: Try restarting the APP. If the issue persists, clear the APP's cache or reinstall it.

8. User Tips

  • For best results, ensure the lens is clean and free from dust or smudges before use.
  • Experiment with different color palettes to find the most effective visualization for your specific application (e.g., "Red heat" for hot spots, "Cold blue" for cold spots).
  • Utilize the regional temperature measurement and high-temperature alarm features for precise monitoring and early detection of anomalies.
  • Keep the APP updated to the latest version to benefit from new features and performance improvements.

9. Warranty and Support

9.1 Warranty & Guarantee

RuoShui (Victor) instruments are 100% genuine original products. A 1-year warranty is provided for all products (excluding damaged items and/or misuse after receipt). Accessories come with a 3-month warranty. If the product is not as advertised, the buyer is responsible for shipping costs for returns. Defective items must be reported and returned within the warranty period in their original packaging.

No battery is included with the product due to safety reasons.

Warranty and Terms
Figure 15: Warranty and other terms.

9.2 Contact and Further Information

For any problems with your order or to learn more about the product, please contact customer service. The manufacturer has a factory in China. If you wish to purchase multiple products, a discounted price may be offered. You are welcome to consult and cooperate.

Manufacturer: Shenzhen Yisheng Victor Technology Co., Ltd

Website: www.china-victor.com

Contact: victor@china-victor.com

A user manual in PDF format is available for download: User Manual (PDF)

10. Packing List

ItemQuantity
Thermal imager1 pcs
Lens cleaning cloth1 pcs
Bag1 pcs
User manual1 pcs
Product Packaging and Accessories
Figure 16: Contents of the product package.

11. Appendix

11.1 Table of Reflectivity of Common Materials

MaterialEmissivityMaterialEmissivity
Asphalt0.90 to 0.98Cloth (black)0.98
Concrete0.94Skin (human body)0.98
Cement0.96Leather0.75 to 0.80
Sand0.9Charcoal (powder)0.96
Soil0.92 to 0.96Paint0.80 to 0.95
Water0.92 to 0.96Paint (matte)0.97
Ice0.96 to 0.98Rubber (black)0.94
Snow0.83Plastic0.85 to 0.95
Glass0.90 to 0.95Wood0.9
Pottery0.90 to 0.94Paper0.70 to 0.94
Marble0.94Chromium oxide0.81
Plaster0.80 to 0.90Copper oxide0.78
Mortar0.89 to 0.91Ferric oxide0.78 to 0.82
Brick0.93 to 0.96Textile0.9

12. Product Video

Video: Demonstrating the RuoShui Victor 328B thermal imager in use, showing its plug-and-play functionality and thermal imaging capabilities for various applications like detecting heat signatures in people, power lines, and electronic devices.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.