1. Product Overview
The XikeStor SKS7300-8F4X is an L2 Managed Ethernet Switch designed for high-speed networking environments. It features 8x 5GbE RJ45 ports and 4x 10GbE SFP+ ports, offering robust connectivity and advanced Layer 2 management capabilities such as VLAN, Port Aggregation, QoS, and comprehensive security features. This switch is suitable for various applications requiring stable and efficient network performance.

Figure 1: XikeStor SKS7300-8F4X L2 Managed Ethernet Switch
Video 1: Product overview and features demonstration.
2. Package Contents
Please verify the contents of your package. If any items are missing or damaged, contact your vendor immediately.
- XikeStor SKS7300-8F4X L2 Managed Ethernet Switch
- Power Cord (EU/US/JP/AU/UK plug, depending on selection)
- RJ45-to-USB Console Cable
- Mounting Brackets (for rack-mount installation)
- Quick Start Guide
3. Physical Features and Interfaces

Figure 2: Front Panel Layout

Figure 3: Rear Panel Layout
Front Panel
- SYS LED: System status indicator.
- PWR LED: Power status indicator.
- Ports 1-8 (RJ45): 5GbE (10/100/1000/2.5/5GBase-T) Ethernet ports.
- Ports 9-12 (SFP+): 10GbE (10GBase-R) Fiber ports.
- Act/Link LEDs: Activity/Link status indicators for SFP+ ports (Green for 1G/2.5G/5G, Orange for 10G).
- Console Port: RJ45 console port for CLI management.
Rear Panel
- AC Power Input: Standard AC 100-240V, 50/60Hz power connector.
- Grounding Terminal: For connecting a grounding wire to protect against electrical surges.

Figure 4: External Features Diagram
4. Installation
4.1 Safety Precautions
- Ensure proper grounding of the device.
- Use the correct power adapter for your region.
- Do not block ventilation openings.
- Avoid exposing the device to moisture or extreme temperatures.
4.2 Rack-Mount Installation
The SKS7300-8F4X supports standard 1U height rack-mounted installation. Attach the provided mounting brackets to the sides of the switch using the screws. Secure the switch into a standard 19-inch equipment rack.
4.3 Power Connection
- Connect the power cord to the AC power input on the rear panel of the switch.
- Plug the other end of the power cord into a suitable AC power outlet (100-240V, 50/60Hz).
- Ensure the power LED on the front panel illuminates, indicating the device is powered on.
4.4 Network Connection
- RJ45 Ports (1-8): Connect standard Ethernet cables from your network devices (e.g., computers, servers, other switches) to these ports. These ports support 10/100/1000/2.5/5GbE speeds.
- SFP+ Ports (9-12): Insert compatible 10GbE SFP+ transceivers into these slots, then connect fiber optic cables to the transceivers. These ports support 10GbE speeds.
5. Initial Configuration and Management
The SKS7300-8F4X switch can be managed via a web-based interface or a Command Line Interface (CLI).

Figure 5: Web and CLI Management Interfaces
5.1 Web-Based Management Login
Before logging into the management interface, ensure your computer's IP address is in the same network segment as the switch.
- Connect and Power On: Connect your computer directly to any RJ45 port on the switch. Ensure the switch is powered on.
- Configure PC IP Address: Set your computer's IP address to
192.168.10.x(where 'x' is any value between 2 and 254, but not 12). Set the subnet mask to255.255.255.0. - Access Web Interface: Open a web browser on your PC and type
https://192.168.10.12into the address bar. Press Enter. - Login: The Web management login interface will appear. Enter the default username and password. The default username is
adminand the default password isadmin(also found on the label at the bottom of the switch). Press Enter.
Note: 1200 series switches (unmanaged series) do not include management features.
5.2 CLI Management
For advanced configuration, use the Command Line Interface (CLI) via the Console port. A RJ45-to-USB Console cable is included for this purpose.
- Connect the RJ45 end of the console cable to the switch's Console port.
- Connect the USB end to your computer.
- Use a terminal emulation program (e.g., PuTTY, Tera Term) to establish a serial connection to the switch. Refer to the full user manual for specific serial port settings.
- Login using the default credentials (username:
admin, password:admin).
6. Operating and Advanced Features
The SKS7300-8F4X is an L2 managed switch offering a wide range of features to optimize network performance and security.

Figure 6: L2 Management Functions
6.1 VLAN Management
Supports VLANs based on IEEE 802.1Q protocol, MAC-based VLAN, IP address segment-based VLAN, Ethernet message-based VLAN, QinQ, and Voice VLAN configuration. This allows for network segmentation, broadcast traffic control, enhanced security, and improved adaptability for multi-service applications.
6.2 Port Aggregation (Link Aggregation)
Supports both Dynamic Aggregation and Static Aggregation to increase bandwidth and provide link redundancy between the switch and other network devices.
6.3 Quality of Service (QoS)
Each port/stream supports 8 priority queues, rate limiting (entry/exit), Diffserv, QoS control configuration, and COS configuration. This ensures prioritized data transmission and prevents malicious bandwidth occupation.
6.4 Security Features
Includes system access management, session attribute management, DoS attack configuration, port access security management, port traffic control, port IP security management, and Access Control Lists (ACL).
6.5 Port Monitoring
Provides comprehensive port monitoring features including port statistics, port mirroring, loop detection, and cable diagnostics for complete network surveillance.

Figure 7: Port Monitoring Features
7. Maintenance
7.1 System Management
- Basic Management: Device Panel, Built-in Services, DNS Management.
- SNMP Management: For network monitoring and management.
- LLDP Management: Link Layer Discovery Protocol.
- ISDP Management: Intelligent Switch Discovery Protocol.
- Scheduled Task Management: For automated operations.
7.2 Configuration Management
- Save Settings: Save current configurations to non-volatile memory.
- Reboot: Restart the switch.
- Download Configuration File: Backup your switch configuration.
- Firmware Update: Update the switch's operating software.
- IMG File Management: Manage firmware image files.
- Diagnostic Tools: Utilize built-in tools for network troubleshooting.
7.3 Heat Dissipation
The SKS7300-8F4X features a robust metal casing and active cooling system, including a silent fan and metal heat sink fins, complemented by honeycomb cooling vents to efficiently dissipate heat and ensure stable operation.

Figure 8: Powerful Heat Dissipation
8. Troubleshooting
8.1 Network Connectivity Issues
- No Link Light: Check cable connections, ensure devices are powered on, and verify port status in the management interface.
- Slow Connection: Verify port speed settings, check for duplex mismatches, and use cable diagnostics to check cable integrity.
- Intermittent Connectivity: Check for network loops using loop detection features. Ensure proper heat dissipation to prevent overheating.
8.2 Management Access Issues
- Cannot Access Web Interface: Verify your PC's IP address is in the same subnet as the switch (default 192.168.10.x, subnet 255.255.255.0). Ensure the switch is powered on and connected.
- Forgot Password: Refer to the full user manual for password recovery procedures, if available. The default credentials are
admin/admin.
8.3 General Issues
- Device Unresponsive: Power cycle the device. If the issue persists, perform a factory reset (refer to the full user manual for instructions).
- Unmanaged 1200 Series: Note that 1200 series switches (unmanaged) do not support the management features described in this manual.
9. Specifications

Figure 9: Product Parameters
| Feature | Description |
|---|---|
| Model Name | SKS7300-8F4X |
| Brand Name | XikeStor |
| Type | Wired Ethernet Switch (L2 Managed) |
| Chip Model | RTL9313 |
| Port Configuration | 8x 10/100/1000/2.5/5GBase-T RJ45 Ports, 4x 10GBase-R (SFP+) Fiber Ports |
| Other Interfaces | 1x RJ45 Management Port (Console) |
| Flash Capacity | 256MB |
| Memory Capacity | 2GB |
| Switching Capacity | 160Gbps |
| Packet Forwarding Rate | 119.04Mpps |
| MAC Address Table | 16K |
| Power Supply | AC 100~240V, 50/60Hz, ≤32W (at full load) |
| Cooling Method | Fan cooling |
| Dimensions (W x H x D) | 280mm x 44mm x 220mm |
| Net Weight | 2.8kg |
| Operating Temperature | 0°C ~ 40°C |
| Storage Temperature | -20°C ~ 70°C |
| Relative Humidity | 20% ~ 85%, non-condensing |
| Storage Humidity | 5% ~ 95%, non-condensing |
| Certifications | CE, FCC, RoHS, pse, WEEE |
10. User Tips
- Regular Firmware Updates: Keep your switch's firmware updated to ensure optimal performance, security, and access to the latest features.
- Secure Management Access: Change the default administrator password immediately after initial setup to prevent unauthorized access. Consider using strong, unique passwords.
- Network Segmentation: Utilize VLAN features to segment your network, improving security and managing broadcast domains more efficiently.
- Monitor Port Status: Regularly check the status of your ports and network traffic through the management interface to identify and resolve potential issues proactively.
- Backup Configuration: Periodically back up your switch configuration file to easily restore settings in case of an unexpected event or device replacement.
11. Support and Documentation
For further assistance, detailed documentation, and the latest software updates, please visit the official XikeStor website.
- Official Website: https://xikestor.com
- User Manual (PDF): A detailed user manual in PDF format is available for download. You can find it on the official website or via the direct link: XikeStor SKS7300-8F4X User Manual PDF