ACMER 4 S

ACMER 4 S 70W CNC Router Machine User Manual

Model: 4 S

1. Introduction

The ACMER 4 S 70W CNC Router Machine is a versatile 3-axis control system designed for precision engraving and carving on various materials such as wood, plastic, and acrylic. Featuring an LED touchscreen and an emergency-stop function, this machine offers both ease of use and safety. Its robust construction, including high-strength aluminum and carbon steel, ensures stability and durability for a wide range of projects.

ACMER 4 S 70W CNC Router Machine overview
Overall view of the ACMER 4 S CNC Router Machine.

2. Setup

Before operating your ACMER 4 S CNC Router Machine, ensure it is properly assembled and placed on a stable, level surface. While specific assembly steps are not detailed here, the machine is designed with high-end components for precision and stability.

2.1 Key Components

  • Spindle Assembly: Features a hand knob for adjustments, a trapezoidal lead screw for precise movement, and a motor protective cover for safety.
  • Frame: Constructed from high-strength aluminum and carbon steel for rigidity.
  • Movement System: Utilizes an eight-wheel structure for smooth and stable movement across the working area.
Spindle assembly details of ACMER 4 S CNC machine
Close-up of the spindle assembly, highlighting hand knob, trapezoidal lead screw, aluminum construction, and motor protective cover.
Eight-wheel structure for stable movement
Close-up of the eight-wheel structure for stable movement.

2.2 Control Panel Connection

Connect the 3.5-inch LED touchscreen control panel to the main unit. Ensure all cables are securely connected. The control panel provides access to power, USB, and TF card interfaces for project loading and machine control.

ACMER 4 S CNC control panel interfaces
Detailed view of the control panel with emergency stop, 3.5-inch touchscreen, power interface, USB interface, TF card slot, and screen interface.

3. Operating Instructions

3.1 Power On/Off

  • To power on, ensure all connections are secure, then flip the main power switch.
  • To power off, turn off the main power switch. In case of an emergency, press the red emergency stop button immediately.

3.2 Loading Projects

Projects can be loaded via the USB interface or TF card slot on the control panel. Use the 3.5-inch LED touchscreen to navigate and select your desired carving files.

3.3 Working Area and Z-Axis Travel

The machine offers a generous working area and Z-axis travel for various project sizes:

  • X-axis: 400mm (15.7 inches)
  • Y-axis: 400mm (15.7 inches)
  • Z-axis: 80mm (3.15 inches)

The 80mm Z-axis travel allows for carving taller objects and creating 3D-like details in a single pass.

ACMER 4 S CNC working range and dimensions
Diagram detailing the working range and overall dimensions of the CNC machine.
ACMER 4 S CNC Z-axis travel diagram
Diagram illustrating the 80mm Z-axis travel (3.15 inches) and pass height.

3.4 Material Compatibility

The ACMER 4 S is suitable for engraving and carving on materials such as wood, plastic, and acrylic. Always ensure your material is securely fastened to the work surface before beginning any operation.

4. Maintenance

Regular maintenance ensures the longevity and optimal performance of your CNC machine.

  • Cleaning: After each use, clean the working area and machine components. The sturdy bulkhead configuration protects the Y-axis from debris, making cleaning easier and preventing damage.
  • Lubrication: Periodically lubricate moving parts such as the lead screws and guide rails according to standard CNC machine maintenance practices.
  • Inspection: Regularly inspect all cables, connections, and mechanical components for wear or damage. Replace any worn parts promptly.
ACMER 4 S CNC bulkhead protection
Image showing the sturdy bulkhead configuration protecting the Y-axis from debris.

5. Troubleshooting

This section provides general guidance for common issues. For more complex problems, please contact customer support.

  • Machine Not Powering On: Check all power connections and ensure the power switch is in the 'On' position. Verify the power outlet is functional.
  • Spindle Not Moving: Ensure the machine is properly connected to the control panel and that no emergency stop is engaged. Check for any obstructions in the movement path.
  • Poor Engraving Quality: Verify that the material is securely clamped, the correct tool is used, and the carving parameters (speed, depth) are appropriate for the material. Ensure the machine is clean and free of debris.
  • Control Panel Unresponsive: Restart the machine. If the issue persists, check the screen interface cable connection.

6. Specifications

FeatureSpecification
BrandACMER
Model Number4 S
Power70W
CNC or NotCNC
Control Axis3-Axis
Engraving Area (X, Y)400mm x 400mm (15.7in x 15.7in)
Z-Axis Travel80mm (3.15in)
Control Panel3.5-inch LED Touchscreen
InterfacesUSB, TF Card Slot
Safety FeaturesEmergency-Stop Switch
Construction MaterialHigh-strength Aluminum, Carbon Steel
CertificationCE
OriginMainland China
Package Dimensions (L x W x H)66cm x 47cm x 34cm
Package Weight18.0 kg

7. User Tips

  • Always ensure your workspace is well-ventilated when operating the CNC machine, especially when working with materials that produce dust or fumes.
  • Start with lower power and slower speeds when working with new materials to determine optimal settings.
  • Regularly back up your project files to prevent data loss.
  • Keep the emergency stop button easily accessible and test its functionality periodically.

8. Warranty and Support

ACMER is committed to providing high-quality products and excellent customer service.

  • Technical Support: ACMER Official Store offers 24/7 online support and one-by-one technical assistance for any operational or technical queries you may have.
  • Returns: Enjoy free returns within 90 days of purchase.
  • Delivery Guarantee: The product comes with a fast delivery guarantee, including provisions for refunds if the package is lost or items are damaged during transit.

For support, please contact the ACMER Official Store directly through their official channels.

Documents - ACMER – 4 S
ASCARVA 4 S CNC Machine User Manual
Comprehensive user manual for the ASCARVA 4 S CNC machine, covering safety guidelines, parts list, specifications, installation, operation, troubleshooting, and after-sales service.
score:27 filesize: 27.34 M page_count: 31 document date: 2025-06-18
[pdf] User Manual
ASCARVA4S V1 2 西班牙语 电子压缩版 support ACMER Manual del usuario drive google file d 1ctj83idTj66 0e7JcGxZH7InEN97epxk view usp link |||
ASCARVA 4 Manual V 1.2 S Shenzhen Titan International Development Technology Co., Ltd.1 Gracias po ... fuentes de energa incompatibles puede causar fallas o daos. 6.Conexin Elctrica Directa La ASCARVA 4 S utiliza una fuente de alta potencia. Evite conectarla a extensiones o regletas para prevenir dao...
score:26 filesize: 27.33 M page_count: 31 document date: 2025-06-18
[pdf] User Manual Installation Guide Specifications
Provided by ManualsAndMore Download User Manual Gembird NS 8PM NS8PM manualsandmore |||
Gembird NS-8PM 8 800 775 98 98 . . www.sotmarket.ru , , NS-8PM ... ch eite e A.B. A66#s sind von der Garantie 4#sgenommen. Gembird D0#tsch and GmbH Over2eg DT, 59494 Soest D0#tsch and 222Cgembird.de/s# rt s# rt gembird.de e . 49-180 5-RGHDRT 0,14 pro Min#te...
score:21 filesize: 2.91 M page_count: 12 document date: 2019-07-23
[pdf] User Manual
ASCARVA4S V1 2德语 电子压缩版 support ACMER Benutzerhandbuch 2 drive google file d 1lqreGjRKmb rhL17HEkLHFmjJNq0rH4 view usp link |||
ASCARVA 4 Handbuch V 1.2 S Shenzhen Titan International Development Technology Co., Ltd.1 Vielen D ... ibler Stromquellen kann zu Fehlfunktionen oder Schden fhren. 6.Direkte Stromverbindung Die ASCARVA 4 S verwendet eine Hochleistungs-Stromversorgung. Vermeiden Sie den Anschluss ber Verlngerungskabel ...
score:19 filesize: 27.34 M page_count: 31 document date: 2025-06-18
[pdf] Instructions
project management bitsavers org fast on site installation fewer spare parts and mini instructions contact I1A 904 Montgomery Bldg Washing 197301 textfiles datamation informatik uni stuttgart de
January project management Varian s Statos31 has interface plus. It plugs directly into all major ... 5 E .. 11 F .. 13 G .. 16 H= 1 I .. 19 J.. 0 K .. 10 L .. 30 M.. 5 N .. 16 0.. 1 P .. 26 Q.. 3 R.. 4 S 2 T.. 8 U 8 V.. 0 W 0 x= 4 y.. 0 Z II 12 L .. 30 P .. 26 I .. 19 G .. 16 N .. 16 F .. 13 Z ....
score:13 filesize: 19.12 M page_count: 152 document date: 2009-03-26
[pdf] User Manual Parts List

S ASCARVA 4 Manual V1.3 Shenzhen Titan International Development Technology Co., Ltd. Thank you fo ... ncompatible power sources may cause malfunctions or damage. 6.Direct Power Connection - The ASCARVA 4 S uses a high-power supply. Avoid connecting it to extension cords or power strips to prevent dama...
score:11 filesize: 3.16 M page_count: 31 document date: 2025-10-23
[pdf] Document

Machine Translated by Google S ASCARVA 4 Handleiding V1.3 Shenzhen Titan International Development T ... bele voedingsbronnen kan storingen of schade veroorzaken. 6. Directe stroomaansluiting - De ASCARVA 4 S gebruikt een krachtige voeding. Sluit hem niet aan op verlengsnoeren of stekkerdozen om schade t...
score:11 filesize: 3.79 M page_count: 31 document date: 2026-01-14
[pdf] User Manual Decleration of Conformity
CLOXW CLI Users Manual EN DE FR ES IT adamhall s3 amazonaws media MARKEN CAMEO |||
USERS MANUAL BEDIENUNGSANLEITUNG MANUEL DUTILISATION MANUAL DE USUARIO INSTRUKCJA OBSLUGI MANUALE DU ... The maximum number of DMX devices in a DMX chain should not exceed 32 units. The Adam Hall 3 STAR, 4 STAR, and 5 STAR product ranges include an extensive selection of suitable cables. DMX CABLES Whe...
score:11 filesize: 6.31 M page_count: 134 document date: 2021-02-09
[pdf] Document

Machine Translated by Google S ASCARVA 4 Manuale V1.3 Shenzhen Titan International Development Techn ... mpatibili pu causare malfunzionamenti o danni. 6. Collegamento diretto all alimentazione: ASCARVA 4 S utilizza un alimentatore ad alta potenza. Evitare di collegarlo a prolunghe o prese multiple per...
score:11 filesize: 3.79 M page_count: 31 document date: 2026-01-12
[pdf] User Manual Decleration of Conformity
CLOXP Cameo Users Manual EN DE FR ES PL IT adamhall s3 amazonaws media MARKEN CAMEO |||
USERS MANUAL BEDIENUNGSANLEITUNG MANUEL DUTILISATION MANUAL DE USUARIO INSTRUKCJA OBSLUGI MANUALE DU ... The maximum number of DMX devices in a DMX chain should not exceed 32 units. The Adam Hall 3 STAR, 4 STAR, and 5 STAR product ranges include an extensive selection of suitable cables. DMX CABLES Whe...
score:11 filesize: 6.15 M page_count: 136 document date: 2020-08-17
[pdf] Troubleshooting Guide
RIDER s PERPETUAL TROUBLESHOOTER S Radio set service manuals 1930 to 1954 Rider 1937 STU worldradiohistory Archive 37 |||
-- ;t,;:--z_--:. -- _-_--,-,...-,,,---__- - -,--- ----,.. _.-..-.___,:----....--,...-IT- -. ei - e ... GRAM MODEL 5/- FACTORY MODEL 93 John F. ider, Publisher www.americanradiohistory.com I AGE 7-4 SEARS MODELS 1a69X,7157 ScheIlatlo ,Alignment SEARS -ROEBUCK CO. vrdRaroR 11,1=I- S o .... S...
score:10 filesize: 28.18 M page_count: 279 document date: 2016-07-04