1. Important Safety Instructions
For optimal performance, please read this manual before using the sensor, and keep it properly for easy reference at any time.
WARNING
This product does not feature an explosion-proof structure and must not be used in flammable environments, such as those containing flammable gases, liquids, or explosives.
SAFETY INFORMATION
- Please use this product in accordance with the instructions in this manual.
- Do not disassemble this product by yourself.
- Pay attention to the rated voltage for use.
2. Product Description
The EARU EAMPS-1-VA is an instrument and equipment used to measure, record, display, and analyze parameters related to electric energy. It is widely applied in various stages of the power system, including power generation, transmission, distribution, and consumption. This device provides comprehensive protection for your electrical appliances against voltage surges, under-voltage, and over-current conditions.
Key Features:
- Under Voltage Protection
- Over Voltage Protection
- Over Current Protection
- Automatic Recovery
- Adjustable Power on Delay Time
- Adjustable Under Voltage Fault Protection Recovery Delay
- Adjustable Over Voltage Fault Protection Recovery Delay
- Adjustable Over Current Fault Protection Recovery Delay
- Manual Calibration of Voltage Error
- Manual Calibration of Current Error

Intelligent Design & Organization:
- UV: Under Voltage Protection
- OV: Over Voltage Protection
- V: Working Voltage Display
- OA: Over Current Protection
- Clock Icon: Recovery Time Adjust
- Lightning Bolt: Surge Protection
- A (Circle): Automatic Recovery
- A (Plus Box): Current Display
- Power Icon: Data Reset

3. Setup
- Unpacking: Carefully remove the protector from its packaging and inspect it for any signs of damage.
- Placement: Ensure the electrical outlet you intend to use is easily accessible and free from obstructions.
- Connection: Plug the EARU EAMPS-1-VA protector directly into a standard EU wall socket (AC 220-240V, 50/60Hz).
- Power On: Once plugged in, the LED display will illuminate, showing the current voltage and current readings. The 'Power' indicator light will turn green.
- Appliance Connection: Plug your electrical appliance into the socket on the front of the protector.

Safety Socket Feature:
The protector is designed with PC grade fire-resistant materials for safety, preventing contact hazards when inserting fingers or small objects. This feature helps protect children from accidentally entering the device.

4. Operating Instructions
4.1. Setting Parameters
The device allows you to adjust various protection parameters. Follow these steps to enter and navigate the setting mode:
- Enter Setting Mode: When the device is displaying voltage and current, press and hold the SET button for 5 seconds. The display will show 'P1'.
- Navigate Parameters: Use the Up (▲) and Down (▼) buttons to cycle through the parameters (P1 to P10).
- Adjust Values: Once you are on the desired parameter (e.g., P1), press SET briefly to enter its adjustment mode. Use the Up (▲) and Down (▼) buttons to change the value.
- Confirm Value: Press SET again to confirm the new value and move to the next parameter, or wait a few seconds for the device to automatically save and exit the adjustment for that parameter.
- Exit Setting Mode: After adjusting all desired parameters, navigate to 'OFF' using the Up (▲) or Down (▼) buttons and press SET to return to the normal display. The device will also automatically exit setting mode if no buttons are pressed for a period.
Parameter List:
- P1: Over-Voltage Protection Value V: Range 240-300V (Default: 270V)
- P2: Over-Voltage Recovery Value V: Range 235-295V (Default: 265V)
- P3: Under-Voltage Protection Value V: Range 140-200V (Default: 170V)
- P4: Under-Voltage Recovery Value V: Range 145-205V (Default: 175V)
- P5: Over-Current Protection Value A: Range 1-16A (Default: 16A)
- P6: Power-on Delay Time S: Range 1-300 seconds (Default: 5 seconds)
- P7: Voltage Protection Recovery Delay Time S: Range 5-300 seconds (Default: 30 seconds)
- P8: Current Protection Recovery Delay Time S: Range 30-300 seconds (Default: 30 seconds)
- P9: Evoltage Regulation: Range -9.5% to +9.5% (Default: 0%)
- P10: Ecurrent Regulation: Range -9.5% to +9.5% (Default: 0%)

4.2. Factory Reset
To restore the device to its factory default parameters:
- In the setting mode, press and hold the Up (▲) and Down (▼) buttons simultaneously for 3 seconds.
- The display will indicate a reset, and all parameters will revert to their default values.
4.3. Battery Level Reset
To reset the internal battery level (if applicable):
- Press and hold the SET button for 10 seconds.
- The device will reset its internal battery level.

4.4. Product Demonstration Video
Video 4.1: A short demonstration of the product's features and operation.
5. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use abrasive cleaners, solvents, or immerse the device in water.
- Storage: When not in use for extended periods, store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Inspection: Periodically check the plug and socket for any signs of wear or damage. If any damage is found, discontinue use immediately and contact support.
6. Troubleshooting
- No Display/No Power: Ensure the device is securely plugged into a live wall socket. Check the wall socket with another appliance to confirm it has power.
- Protection Tripping Frequently: Review your connected appliance's power consumption. Adjust the Over-Current Protection (P5) or Over-Voltage/Under-Voltage Protection (P1-P4) settings if they are too sensitive for your application. Ensure the appliance is not faulty.
- Inaccurate Readings: If you suspect voltage or current readings are inaccurate, you can use P9 (Evoltage Regulation) and P10 (Ecurrent Regulation) to calibrate the display. Refer to a known accurate meter for comparison.
- Device Not Recovering Automatically: Check the recovery delay settings (P7, P8). Ensure they are set to an appropriate time for automatic recovery.
7. Specifications
| Parameter | Value |
|---|---|
| Brand | EARU |
| Model Number | EAMPS-1-VA |
| Rated Voltage | AC220-240V |
| Frequency | 50/60Hz |
| Load Current | 1-16A (Adjustable) |
| Under Voltage Protection | 140-200V (Adjustable) |
| Over Voltage Protection | 240-300V (Adjustable) |
| Delay Time | 5-300S (Adjustable) |
| Socket Type | EU |
| Certification | CE |
| Dimensions (H x W x D) | 136mm x 61mm x 86mm (approx. 5.35in x 2.4in x 3.39in) |
| Material | PC grade fire-resistant, flame-retardant, high conductivity copper plate (nickel plating) |

8. User Tips
- LED Brightness: Some users find the green LED light from the ammeter indicator to be very bright. If this is an issue, a small piece of white electrical tape or a light diffuser can be placed over the screen to reduce its intensity without obscuring the reading.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original seller or the manufacturer directly. Please have your product model number (EAMPS-1-VA) and purchase details ready when contacting support.
A PDF version of this user manual may be available for download from the seller's product page or by contacting customer support.