1. General Information
The PowMr POW-Boost 10A MPPT Solar Charge Controller is designed to efficiently manage power flow from solar panels to batteries. It utilizes advanced Maximum Power Point Tracking (MPPT) technology to maximize energy harvesting from photovoltaic panels, even when the input voltage from the solar panel is lower than the battery voltage. This controller boosts the voltage to meet the battery's charging requirements, ensuring reliable and efficient charging.
It features integrated charge presets and adaptive charge logic suitable for various battery types, including LiFePO4, Gel, and flooded lead-acid. The controller is compatible with 24V, 36V, 48V, 60V, and 72V system voltages. Multiple protection mechanisms are integrated to safeguard both the controller and connected batteries, including protection against overcharge, short circuit, reverse current, over-discharging, reverse polarity, and overload.
An intuitive LCD display provides comprehensive monitoring of charging status and real-time data, allowing users to configure operational programs and optimize energy management. The unit operates silently due to natural convection cooling, eliminating the need for fans or moving parts.





2. Important Safety Instructions
WARNING: CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- Carefully read this manual before installing or operating the controller. Retain the manual for future reference.
- The controller must not be installed or operated by individuals lacking appropriate knowledge, experience, or competence, or those with compromised physical, sensory, or mental capabilities, unless under strict instruction and supervision.
2.1 Controller Installation and Operation
- There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
- Install the controller in a location with good natural airflow/ventilation and sufficient unobstructed space around it.
- Install the controller on a non-flammable substrate. Ensure no heat-sensitive items are in the immediate vicinity; the controller may become hot during operation.
- Install the controller in a location protected from environmental conditions such as direct sunlight, water, high moisture, and dust. Keep it away from flammable liquids or gases. The controller is for indoor use only.
- Do not install or place/operate the controller on top of the battery, directly above the battery, or in a sealed compartment with the battery, as batteries can emit explosive gases.
- Do not cover or place any other items on top of the controller.
2.2 Battery Installation and Charging
- Install and charge the battery in a location with good natural airflow/ventilation.
- Ensure no ignition sources are near the battery, as batteries can emit explosive gases.
- Battery acid is corrosive; if contact occurs, immediately rinse with water.
- Do not charge non-rechargeable batteries. Do not charge Li-ion batteries if the battery temperature is below 0°C. Never charge a frozen battery.
- Ensure the unit is properly set up for the type of battery intended to be charged.
2.3 Battery DC Connections
- Ensure the DC system is fully shut down/isolated prior to disconnecting existing cabling or making new connections to the battery/DC system.
- Use flexible multi-stranded copper cable with sufficient cross-sectional area, in line with an appropriate fuse or circuit breaker.
- NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.
2.4 Controller Setup
- Refer to the battery manufacturer's instructions and specifications to ensure the battery is suitable for use with this controller and confirm recommended charge settings.
- The integrated charge modes combined with adaptive charge logic are well suited for most common battery types, such as flooded lead-acid, Gel, and LiFePO4.
3. Product Overview
The PowMr POW-Boost 10A MPPT Solar Charge Controller features an LCD display, function keys for navigation, PV input and battery ports, and a heat sink for efficient cooling.



3.1 Product Dimensions

4. Installation
4.1 Unpacking and Inspection
Before unpacking, check the package for damage. After unpacking, verify that all contents are present and undamaged. The package should contain the controller and a user manual.
4.2 Preparing for Installation
The controller is designed for wall mounting using flanges on its heatsink backplane.
Select the Mount Location:
Consider the following for a suitable and safe location:
- Install in a location with good natural airflow/ventilation.
- Ensure sufficient unobstructed space around the controller. A minimum spacing of 150mm is recommended between the top, bottom, and sides.

- Install on a non-flammable substrate. Ensure no heat-sensitive items are nearby, as the controller can get hot during operation.
- Install in a location protected from direct sunlight, water, high moisture, and dust, and away from flammable liquids or gases. This controller is for indoor use only.
- Do not install on top of or directly above the battery, or in a sealed compartment with the battery, due to explosive gases.
- Do not cover the controller or place other items on top of it.
4.3 Installation Steps
- Strictly adhere to the requirements and recommendations for location selection.
- Inspect the surroundings and spatial environment of the installation location.
- Mark the installation holes.
- Drill the holes.
- Secure the controller using four M5 screws.

5. Connection
5.1 Things You Need
Ensure you have the following parts for installation and connection:
| Item | Quantity |
|---|---|
| Controller (included) | 1 |
| DC-cable to connect the positive DC connection (+) of the Pstar Controller to the positive polarity of DC input or DC output | 2 |
| DC-cable to connect the negative DC connection (-) of the Pstar Controller to the negative polarity of DC input or DC output | 2 |
| DC breaker | 2 |
| PV array | 1 |
| Battery pack | 1 |
5.2 Wiring Precautions
- All wiring must be carried out by qualified professionals.
- Prioritize connecting the battery before connecting the photovoltaic array.
- Do not install the controller and lead-acid batteries in an enclosed environment as batteries release explosive gases.
- The controller can handle photovoltaic input voltage within the specified range. Exceeding the maximum input voltage can damage the equipment. Inspect the system before making connections.
- When configuring wiring and circuit breakers, refer to relevant specifications for maximum current. Choose appropriate cable and circuit breaker sizes. Thicker, shorter cables enhance boost performance and minimize voltage drop.
- Install separate DC circuit breakers for each circuit to facilitate safe disconnection during maintenance/repair and provide overcurrent protection.
- The controller ports are labeled with polarity markings for PV input and battery charging. Strictly follow these markings when connecting cables.
- Keep each circuit breaker in the open position during wiring.
- Tighten port screws to avoid loose connections, overheating, and potential fire hazards.
- Before closing circuit breakers, check that cable terminals are securely connected and there are no reverse connections or errors.
5.3 Connection Steps
- Battery Wiring: Prioritize connecting the battery module. Install a separate DC circuit breaker for the battery charging circuit.
- Photovoltaic Wiring: After confirming the configured photovoltaic array voltage is within the acceptable range, connect the photovoltaic array. Install a separate DC circuit breaker on the photovoltaic input line.
- Controller Startup: Once the battery and photovoltaic array are connected, check for reverse connections or loose cables. After confirming everything is correct, sequentially close the circuit breakers for the battery charging circuit and photovoltaic input circuit to start the controller.

Video demonstrating the wiring and operation of the PowMr MPPT Solar Charge Controller.
6. Operation
6.1 Operation Interface Introduction
The controller features an LCD display and four function keys: PRG/ESC, Up, Down, and ENTER.

| Icon | Description |
|---|---|
| LCD Display (Left Side) |
|
| LCD Display (Right Side) |
|
| Battery Charge Status Indicator | Indicates the battery charge status. |
| PRG/ESC Key | Used to enter or exit the setup program. |
| Up Arrow Key | Navigates to the next screen or setting item/increases the setting value. |
| Down Arrow Key | Goes back to the previous screen or setting item/decreases the setting value. |
| ENTER Key | In the setup interface, enters a setting item or confirms the setting value. |
6.2 Viewing and Configuration Guide for Parameters
After starting the device, use the Up and Down keys to toggle between different screen information on the main interface.
Browsing Interface Data:
| Page | Left Side Parameters | Right Side Parameters |
|---|---|---|
| 1 | Photovoltaic Input Voltage | Current Battery Voltage |
| 2 | Photovoltaic Input Power | Charging Current |
| 3 | Operating Mode | Device Temperature |
Operation Mode:
| Mode Code | Description |
|---|---|
| 3.0 | Standby state |
| 4.0 | MPPT State |
| 7.0 | Content Voltage charging state |
| 8.0 | Flooded charging state |
Configuration Setup Program:
To access the setup program, press the "PRG/ESC" key. Use the Up and Down keys to navigate through options. Press "ENTER" to enter a specific setting. Adjust values with Up and Down keys, then press "ENTER" to confirm.
| Item | Program | Description |
|---|---|---|
| D01 | Open Circuit Voltage of PV Input | Sets the maximum voltage value the controller will allow from the solar panel, based on the solar panel's maximum open-circuit voltage. |
| D02 | Bulk Charging Voltage | Specific to charging lithium batteries. Sets the maximum charging voltage for lithium batteries. |
| D03 | Float Charging Voltage | Specific to charging lead-acid batteries. Maintains battery voltage at the float charging voltage with a weak current after full charge. |
| D04 | Return-to-MPPT Charging Voltage | When battery voltage drops to this value, the controller initiates a new charging cycle. |
| D05 | Maximum Charging Current | Sets the maximum charging current based on the connected battery's charging parameters. |
| D06 | Battery Voltage Calibration | Calibrates the battery voltage measured by the controller if it differs from other devices like a multimeter. |
7. Charging Parameter Configuration Reference
Refer to the tables below for appropriate charging parameters based on your battery type.
7.1 For Lead-Acid Battery:
| Voltage control parameters | 24V | 36V | 48V | 60V | 72V |
|---|---|---|---|---|---|
| Boost charging voltage | 28.8V | 43.2V | 57.6V | 72V | 86.4V |
| Sealed Float charging voltage | 27.6V | 41.4V | 55.2V | 69V | 82.8V |
| Boost reconnect charging voltage | 26.4V | 39.6V | 52.8V | 66V | 79.2V |
| Boost charging voltage | 28.4V | 42.6V | 56.8V | 71V | 85.2V |
| GEL Float charging voltage | 27.6V | 41.4V | 55.2V | 69V | 82.8V |
| Boost reconnect charging voltage | 26.4V | 39.6V | 52.8V | 66V | 79.2V |
| Boost charging voltage | 29.2V | 43.8V | 58.4V | 73V | 87.6V |
| FLD Float charging voltage | 27.6V | 41.4V | 55.2V | 69V | 82.8V |
| Boost reconnect charging voltage | 26.4V | 39.6V | 52.8V | 66V | 79.2V |
7.2 For Lithium Iron Phosphate Battery:
| Voltage control parameters | Boost charging voltage | Float charging voltage | Boost reconnect charging voltage |
|---|---|---|---|
| 7S | 25.2V | 24.5V | 22.4V |
| 8S | 28.8V | 28V | 25.6V |
| 11S | 39.6V | 38.5V | 35.2V |
| 12S | 43.2V | 42V | 38.4V |
| 15S | 54V | 52.5V | 48V |
| 16S | 57.6V | 56V | 51.2V |
| 18S | 64.8V | 63V | 57.6V |
| 19S | 68.4V | 66.5V | 60.8V |
| 22S | 79.2V | 77V | 70.4V |
| 23S | 82.8V | 80.5V | 73.6V |
7.3 For Ternary Lithium Battery:
| Voltage control parameters | Boost charging voltage | Float charging voltage | Boost reconnect charging voltage |
|---|---|---|---|
| 6S | 25.2V | 24.6V | 22.8V |
| 7S | 29.4V | 28.7V | 26.6V |
| 9S | 37.8V | 36.9V | 34.2V |
| 10S | 42V | 41V | 38V |
| 12S | 50.4V | 49.2V | 45.6V |
| 13S | 54.6V | 53.3V | 49.4V |
| 16S | 67.2V | 65.6V | 60.8V |
| 17S | 71.4V | 69.7V | 64.6V |
| 19S | 79.8V | 77.9V | 72.2V |
| 20S | 84V | 82V | 76V |
8. Maintenance
Perform inspections and maintenance at least twice a year for optimal performance.
- Ensure the controller is firmly installed in a clean and dry environment.
- Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the heat sink.
- Check all exposed wires for insulation damage (solarization, frictional wear, dryness, pests). Repair or replace damaged wires if necessary.
- Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
- Confirm all system components are properly grounded.
- Confirm all terminals have no corrosion, insulation damage, high temperature, or discolored signs, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. Clean if present.
WARNING: Risk of electric shock!
- Ensure all power is turned off before performing inspections or operations.
9. Troubleshooting
The controller display shows error signals to help identify the source of a failure.
| Fault Code | Possible Cause | What to do |
|---|---|---|
| No. 1 | Reverse Polarity | Fully protected; no damage. Correct the miswiring to resume normal operation. |
| No. 2 | Maximum Charging Current limit | Ensures safe charging current to prevent battery damage and prolong battery life. |
| No. 3 | Short Circuit Protection | The controller shuts down output for one minute. |
| No. 4 | Controller Overheating | When temperature exceeds 85°C, charging stops. Resumes when temperature is 75°C. |
| 60 | Temperature Too High | Normal charging and discharging resume once device temperature cools below recovery temperature. |
| 63 | High Battery Voltage | Reconfigure parameters or verify if battery voltage exceeds rated voltage. Consider shutting off the photovoltaic array circuit breaker. |
| 71 | High PV Voltage | Reconfigure parameters or lower the voltage by adjusting series and parallel connections. |
| 73 | Excessive Charging Current | Reduce the number of photovoltaic arrays connected to the controller. |
10. Technical Specifications
| Category | Specification | ||
|---|---|---|---|
| Model | POW-Boost 10A | ||
| PV Input | |||
| PV Input Voltage | 15~25V | 25~48V | 48~60V |
| PV Input Power | ≤150W | ≤250W | ≤400W |
| System Voltage | 24/36/48/60/72V | 48/60/72V | 60/72V |
| Charging Mode | |||
| Charging technology | MPPT | ||
| Charge Algorithm | 3-Stage | ||
| Self-consumption | <2W | ||
| Nominal System Voltage | 24V/36V/48V/60V/72V | ||
| Battery Voltage Range | 20~88V | ||
| Environment | |||
| Operating Temperature Range | -35°C~+65°C | ||
| Humidity Range | ≤95% | ||
| General Specification | |||
| Protection Class | IP32 | ||
| Dimension | 140*85*50mm | ||
| Net weight | 305g | ||
11. User Tips
- Connection Order is Crucial: Always connect the battery to the controller first before connecting the solar panels. This prevents potential damage to the controller.
- Verify Readings: Some users have reported discrepancies in current sensor readings and voltage calibration. It is advisable to verify the controller's readings with an external multimeter, especially during initial setup, to ensure accurate charging and prevent battery damage. Adjust calibration (D06) if necessary.
- Optimize PV Input: If you experience lower-than-expected charging wattage, ensure your solar panel voltage and power are within the optimal range for the controller. Adjusting series/parallel connections of PV arrays might be necessary to achieve better performance.
- Check for Defects: Upon arrival, carefully inspect the device for any manufacturing defects, such as blocked connection sockets, before attempting installation.
- Consult PDF Manual: For a more detailed guide, including specific diagrams and advanced settings, please refer to the official user manual PDF available at https://manuals.plus/m/70c794a93a20bc017355910dda0acccdeeb89c8f5197ab19d23edfff9eebc531.
12. Warranty and Support
All PowMr products typically come with a 1-year warranty from the store.
For technical support or inquiries, please contact:
- Email: support@powmr.com
- Tel/Fax: +86 755-28219903
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China