Daxtromn Hybrid Solar Inverter Series

Contents

Daxtromn Hybrid Solar Inverter Series User Manual

Model: Hybrid Solar Inverter Series

Brand: Daxtromn

1. Introduction

This manual provides essential information for the safe and efficient operation of your Daxtromn Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

Daxtromn Hybrid Solar Inverter
Figure 1: Daxtromn Hybrid Solar Inverter (General View)

2. Safety Instructions

  • Read all instructions and cautionary markings on the unit and in this manual before operating the inverter.
  • Do not disassemble the inverter. Refer servicing to qualified personnel.
  • Ensure proper ventilation around the inverter to prevent overheating.
  • Connect the inverter to a grounded AC outlet.
  • Do not expose the inverter to rain, snow, spray, or any liquids.
  • Before making any connections, ensure all power sources (solar, battery, utility) are disconnected.
  • Use appropriate wiring and circuit breakers as specified in the electrical codes.

3. Product Overview

The Daxtromn Hybrid Solar Inverter series offers a range of models designed for various power needs, integrating solar power, battery storage, and utility/generator input to provide reliable power to your home appliances. Key features include pure sine wave output, high MPPT solar charger efficiency, and flexible input voltage ranges.

3.1. Model Variants and Key Specifications

The Daxtromn Hybrid Solar Inverter series includes several models, each tailored for specific power requirements:

  • AOH-1KW: 1KW Rated Power, 12VDC Battery, 80A Max DC Charger, 150V Max DC PV Input, 20-150VDC PV Input Voltage Range, 1 Load Output.
  • GGH-3.5KW: 3.5KW Rated Power, 24VDC Battery, 80A Max DC Charger, 500V Max DC PV Input, 60-450VDC PV Input Voltage Range, 1 Load Output, Dry Contact Support.
  • AGH-4.2KW-BMS: 4.2KW Rated Power, 24VDC Battery, 120A Max DC Charger, 500V Max DC PV Input, 60-450VDC PV Input Voltage Range, 2 Loads Output, With WIFI.
  • AGH-6.2KW-BMS: 6.2KW Rated Power, 48VDC Battery, 120A Max DC Charger, 500V Max DC PV Input, 60-450VDC PV Input Voltage Range, 2 Loads Output, With/Without WIFI.
  • GGH-6.5KVA: 6.5KVA Rated Power, 48VDC Battery, 80A Max DC Charger, 500V Max DC PV Input, 60-450VDC PV Input Voltage Range, 1 Load Output, Dry Contact Support.
  • AGH-8.2KW-BMS: 8.2KW Rated Power, 48VDC Battery, 140A Max DC Charger, 500V Max DC PV Input, 60-450VDC PV Input Voltage Range, 2 Loads Output, With/Without WIFI.
  • AGH-10.2KW-BMS: 10.2KW Rated Power, 48VDC Battery, 160A Max DC Charger, 500V Max DC PV Input, 60-450VDC PV Input Voltage Range, 2 Loads Output, With/Without WIFI.

3.2. Component Identification

Refer to the following diagrams for component identification of your specific inverter model.

3.2.1. AGH-10.2KW-BMS / AGH-8.2KW-BMS Product Overview

AGH-10.2KW-BMS Product Overview
Figure 2: AGH-10.2KW-BMS / AGH-8.2KW-BMS Product Overview
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Touch function buttons
  6. Power on / off switch
  7. AC input
  8. Main output
  9. Second output
  10. PV1 & PV2 input
  11. WIFI communication/RS-232 port
  12. Battery communication/RS-485 port
  13. Battery input

3.2.2. AGH-4.2KW-BMS / AGH-6.2KW-BMS Product Overview

AGH-4.2KW-BMS / AGH-6.2KW-BMS Product Overview
Figure 3: AGH-4.2KW-BMS / AGH-6.2KW-BMS Product Overview
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on / off switch
  7. AC input
  8. Main output
  9. Second output
  10. PV input
  11. Battery input
  12. WIFI communication/RS-232 port
  13. Battery communication/RS-485 port

3.2.3. GGH-3.5KW / GGH-6.5KVA / AOH-1KW Product Overview

GGH-3.5KW / GGH-6.5KVA / AOH-1KW Product Overview
Figure 4: GGH-3.5KW / GGH-6.5KVA / AOH-1KW Product Overview
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on / off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. Circuit breaker
  12. Output receptacles

3.2.4. GGH Series Structure and Dimensions

GGH Series Inverter Structure and Dimensions
Figure 5: GGH Series Inverter Structure and Dimensions (Approx. 302mm W x 490mm H x 110mm D)

4. Installation and Setup

Proper installation is crucial for the safe and efficient operation of your inverter. It is recommended that installation be performed by a qualified electrician.

4.1. Mounting the Inverter

  • Choose a dry, well-ventilated area away from direct sunlight, heat sources, and flammable materials.
  • Ensure sufficient clearance around the inverter for proper airflow (minimum 20 cm on all sides).
  • Mount the inverter vertically on a sturdy wall or support structure.
  • Use appropriate mounting hardware for the weight of the inverter.

4.2. Connection Diagram

The connection process involves connecting solar panels, batteries, utility/generator, and home appliances to the inverter. Always ensure all power sources are disconnected before making any connections.

4.2.1. Connection Diagram for AGH-10.2KW-BMS / AGH-8.2KW-BMS

Connection Diagram for AGH-10.2KW-BMS / AGH-8.2KW-BMS
Figure 6: Connection Diagram for AGH-10.2KW-BMS / AGH-8.2KW-BMS. Shows connections for Solar Power, Generator (or Utility), External Battery Packs (charging voltage adjustable), and Home Appliances.

4.2.2. Connection Diagram for AGH-4.2KW-BMS / AGH-6.2KW-BMS

Connection Diagram for AGH-4.2KW-BMS / AGH-6.2KW-BMS
Figure 7: Connection Diagram for AGH-4.2KW-BMS / AGH-6.2KW-BMS. Illustrates connections for Solar Power, Generator (or Utility), External Battery Packs, and Home Appliances.

4.2.3. Connection Diagram for GGH-3.5KW / GGH-6.5KVA / AOH-1KW

Connection Diagram for GGH-3.5KW / GGH-6.5KVA / AOH-1KW
Figure 8: Connection Diagram for GGH-3.5KW / GGH-6.5KVA / AOH-1KW. Shows connections for Solar Power, Generator (or Utility), Battery, and Home Appliances.

4.3. Wiring Steps (General)

  1. Battery Connection: Connect the battery bank to the inverter's battery terminals. Ensure correct polarity (+ to + and - to -).
  2. AC Input Connection (Utility/Generator): Connect the AC input from your utility grid or generator to the designated AC input terminals on the inverter.
  3. PV Input Connection (Solar Panels): Connect the solar panel array to the PV input terminals. Observe correct polarity and ensure the PV input voltage is within the inverter's specified range.
  4. AC Output Connection (Loads): Connect your home appliances or load center to the AC output terminals of the inverter.
  5. Communication Connections (if applicable): For models with WIFI, RS-232, or RS-485 ports, connect the respective communication cables for monitoring and control.
  6. Grounding: Ensure the inverter is properly grounded according to local electrical codes.

WARNING: Incorrect wiring can cause severe damage to the inverter and connected equipment, and poses a risk of electric shock. Always consult a qualified electrician.

5. Operation

Once installed and wired correctly, you can begin operating your Daxtromn Hybrid Solar Inverter.

5.1. Powering On/Off

  1. Power On:
    1. Ensure all connections are secure.
    2. Turn on the battery breaker.
    3. Turn on the PV array breaker (if applicable).
    4. Turn on the AC input breaker (if applicable).
    5. Press the Power On/Off switch on the inverter (refer to Product Overview diagrams for location).
    6. The LCD display will light up, and the inverter will perform a self-test.
  2. Power Off:
    1. Turn off the AC output breaker (disconnect loads).
    2. Turn off the AC input breaker.
    3. Turn off the PV array breaker.
    4. Turn off the battery breaker.
    5. Press and hold the Power On/Off switch on the inverter until it shuts down.

5.2. LCD Display and Function Buttons

The LCD display provides real-time information about the inverter's status, input/output voltages, battery charge, and more. The function buttons allow you to navigate menus and adjust settings.

  • Status Indicator: Shows the current operating status (e.g., charging, inverting, fault).
  • Charging Indicator: Indicates battery charging status.
  • Fault Indicator: Lights up or flashes to indicate an error or fault condition.
  • Touch Function Buttons: Used to scroll through display screens, enter settings, and confirm selections.

5.3. Monitoring Software (for compatible models)

For models with WIFI, RS-232, or RS-485 communication, bundled monitoring and setting software is available. This software allows for remote monitoring of inverter performance, energy production, battery status, and adjustment of operational parameters. Refer to the software's dedicated manual for detailed instructions.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Daxtromn Hybrid Solar Inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connections Check: Annually inspect all electrical connections (battery, AC input/output, PV input) for tightness and signs of corrosion. Tighten any loose connections.
  • Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal cleanliness regularly. Follow battery manufacturer's maintenance guidelines.
  • Ventilation: Ensure the area around the inverter remains clear and well-ventilated to prevent overheating.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for your model. Follow update instructions carefully.

7. Troubleshooting

This section provides basic troubleshooting steps for common issues. For complex problems, contact qualified service personnel.

ProblemPossible CauseSolution
Inverter does not power onNo battery connection; Battery voltage too low; Power switch off; Internal fault.Check battery connections and voltage; Ensure power switch is pressed; Charge battery; Contact support if fault persists.
No AC outputOverload; Short circuit; High/low battery voltage; Inverter in standby mode.Reduce load; Check for short circuits; Check battery voltage; Verify operating mode settings.
Battery not chargingPV input too low/high; AC input not present; Charger settings incorrect; Faulty battery.Check PV voltage and connections; Verify AC input; Adjust charger settings; Test battery.
Fault indicator onInternal fault; Over-temperature; Over-voltage; Under-voltage.Note the error code on the LCD (if any); Check ventilation; Verify input voltages; Power cycle the inverter. If fault persists, contact support.

8. Specifications

Detailed specifications vary by model. Please refer to the tables below for your specific inverter model.

8.1. AGH-8.2KW-BMS / AGH-10.2KW-BMS Specifications

Specifications for AGH-8.2KW-BMS and AGH-10.2KW-BMS
Figure 9: Specifications for AGH-8.2KW-BMS and AGH-10.2KW-BMS

8.2. AGH-4.2KW-PRO / AGH-6.2KW-PRO Specifications

Specifications for AGH-4.2KW-PRO and AGH-6.2KW-PRO
Figure 10: Specifications for AGH-4.2KW-PRO and AGH-6.2KW-PRO

8.3. GGH-3.5KW / GGH-6.5KVA Specifications

Specifications for GGH-3.5KW and GGH-6.5KVA
Figure 11: Specifications for GGH-3.5KW and GGH-6.5KVA

8.4. AOH-1KW Specifications

Specifications for AOH-1KW
Figure 12: Specifications for AOH-1KW

8.5. Physical Dimensions and Weight

Package dimensions for all models are approximately 51 cm (Length) x 42 cm (Width) x 18 cm (Height), with a package weight of approximately 10.0 kg.

Specific device net weights:

  • AOH-1KW: 3 kg
  • AGH-4.2KW-PRO / AGH-6.2KW-PRO: 9.5 kg
  • GGH-3.5KW: 8.44 kg
  • GGH-6.5KVA: 9.7 kg
  • AGH-8.2KW-BMS: 14.2 kg
  • AGH-10.2KW-BMS: 16 kg

9. User Tips

  • Ventilation is Key: Ensure your inverter has ample space around it for air circulation. Overheating can reduce efficiency and lifespan.
  • Check Connections Regularly: Loose connections are a common cause of issues. Periodically inspect all wiring for tightness and signs of wear.
  • Monitor Performance: Utilize the LCD display or monitoring software (if available for your model) to keep an eye on input/output, battery status, and any alerts. Early detection of anomalies can prevent bigger problems.
  • Battery Compatibility: Always ensure your battery bank voltage and type are compatible with your specific inverter model (e.g., 12VDC for AOH-1KW, 48VDC for AGH-6.2KW-BMS).

10. Warranty and Support

For warranty information, technical support, or service requests, please contact your retailer or the manufacturer directly. Keep your purchase receipt and product serial number handy when contacting support.

The manufacturer, Daxtromn, is committed to providing reliable products and customer service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.