Tuya CCHW005

User Manual: WiFi Tuya Water Heater Heating Inverter Heat Pump Controller PCBA

Model: CCHW005

This manual provides comprehensive instructions for the installation, operation, and maintenance of your new WiFi Tuya Inverter Heat Pump Controller. Please read thoroughly before use.

1. Product Overview

The CCHW005 is a sophisticated WiFi-enabled inverter heat pump controller designed for water heater heating systems. It features a main control board, an inverter driver board, a TFT touch screen display, and various sensors to manage heating and cooling modes efficiently. This system is compatible with Tuya smart home platforms for remote control and monitoring.

Overview of the Inverter Heating Heat Pump Controller components
Figure 1: Overview of the Inverter Heating Heat Pump Controller components, including the main control board, TFT screen display, inverter driver board, and sensors with wires.

2. Components List

The package includes the following main components:

Inverter Heating Heat Pump Controller Components List
Figure 2: Visual representation of the Inverter Heating Heat Pump Controller Components List: Heat pump control board, TFT Screen display, Inverter driver board, and Sensors & Wires.
  • Heat pump control board (Main PCBA)
  • TFT Touch Screen Display
  • Inverter driver board
  • NTC Sensors & Wires (5KΩ/25°C, B value 3470K; 50K/25°C, B value 3490K)

3. Setup and Installation

3.1 Physical Dimensions

Ensure adequate space for mounting the display and main control board. The dimensions are as follows:

Dimensions of the TFT touch screen display unit
Figure 3: Dimensions of the TFT touch screen display unit (142mm width, 95mm height, 22mm depth) and its rear mounting bracket (132mm width, 85mm height).
  • TFT Display Unit: 142mm (W) x 95mm (H) x 22mm (D)
  • Display Mounting Bracket: 132mm (W) x 85mm (H)
  • Main Control Board Mounting Size: 210mm x 134mm x 34mm

3.2 System Diagram

The following diagram illustrates the overall system architecture and component interconnections:

System diagram of the heat pump controller
Figure 4: System diagram illustrating the interconnection of the Filter board, Inverter driver board, Main control board, and Compressor, showing power and signal flow.

Key Connections:

  • Power Input: AC-L, AC-N from power source to Filter board.
  • Filter Board Output: L-OUT, N-OUT to Inverter driver board.
  • Inverter Driver Board: Connects to the Compressor (M) and the Main control board (CN-L, CN-N).
  • Main Control Board: Connects to the Inverter driver board (CN-L, CN-N) and various peripherals.

3.3 Wiring Diagram

Refer to the detailed wiring diagram below for connecting all components to the main control board. Proper wiring is crucial for safe and correct operation.

Detailed wiring diagram for the heat pump control board
Figure 5: Detailed wiring diagram for the heat pump control board, illustrating connections for power, sensors, relays, and various components like EEV, EVI, DIP switches, and pressure switches.

Wiring Key:

  • Power Input: EGND, N, Live wire, Neutral wire, Earth wire, DC fan motor.
  • Outputs/Inputs (Top Right): EEV, EVI, DIP switch, COM, BTW requirement switch, Compressor over-heat protection switch, Water flow switch, Low pressure switch, High pressure switch, DHW tank temperature, BTW tank temperature, EVI outlet temperature / Solar temperature.
  • Inputs/Outputs (Bottom Right): Inverter driver board, Display panel, Suction temperature, Coil temperature, Ambient temperature, Inlet water temperature, Outlet water temperature, Exhausted gas temperature.

WARNING: All wiring should be performed by a qualified electrician. Ensure power is disconnected before making any connections.

4. Operating Instructions

4.1 TFT Touch Screen Display

The TFT touch screen display provides an intuitive interface for controlling the heat pump. It shows current status, temperature settings, and allows mode selection.

TFT touch screen display showing different operating modes
Figure 6: TFT touch screen display showing different operating modes: Heating, Cooling, Hot Water, and Dual mode, with temperature settings and status indicators.

Available Modes:

  • Heating Mode: Maintains a set heating temperature.
  • Cooling Mode: Maintains a set cooling temperature.
  • Hot Water Mode (DHW): Dedicated mode for domestic hot water production.
  • Dual Mode (H-DHW): Combines heating and hot water functions.

Basic Controls:

  • ON/OFF: Power the unit on or off.
  • MODE: Cycle through available operating modes.
  • SETTING: Access advanced settings and parameters.
  • TIMER: Program scheduled operation times.

4.2 Tuya App Integration

The controller supports WiFi connectivity and can be integrated with the Tuya Smart app for remote control and monitoring. Follow the instructions provided with the Tuya app to add your device and configure its settings.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your heat pump controller.

  • Cleaning: Periodically wipe the TFT display with a soft, dry cloth. Avoid abrasive cleaners.
  • Inspections: Annually inspect all wiring connections for tightness and signs of wear or corrosion.
  • Software Updates: Check the Tuya app for any available firmware updates for the controller to ensure you have the latest features and bug fixes.
  • Environmental Conditions: Ensure the main control board is installed in a dry, well-ventilated area, protected from extreme temperatures and humidity.

6. Troubleshooting

If you encounter issues, refer to the following basic troubleshooting steps:

  • No Power to Display: Check power supply connections and ensure the main control board is receiving power (220V or 380V AC).
  • Display Not Responding: Try restarting the unit by cycling the power. If the issue persists, check the connection cable between the display and the main board.
  • Incorrect Temperature Readings: Verify that all NTC sensors are correctly connected and positioned. Ensure sensor wires are not damaged.
  • WiFi Connectivity Issues: Ensure your home WiFi network is active and the controller is within range. Re-attempt pairing with the Tuya app if necessary.
  • Heat Pump Not Operating: Check the selected operating mode on the display. Verify all safety switches (e.g., water flow, pressure switches) are in their normal operating state. Consult the wiring diagram to ensure all components are correctly connected.

For complex issues, contact qualified service personnel.

7. Specifications

Feature Specification
Model Number CCHW005
Product Name Inverter Heat Pump Controller
Type PCB Board, Heat pump control PCB Board
Base Material Double-Sided Boards FR-4
Material FR-4
Copper Thickness 1OZ
Board Thickness 1.6mm
Min. Hole Size Component hole: 0.6-2.0mm, Mounting hole: 4mm
Min. Line Width More than 0.3mm
Min. Line Spacing More than 0.3mm
Functional Application PCB Design/Fabrication
Surface Finishing Lead free
Board Size Class A2 insulation board
Power Supply 220 or 380 ±10%(VAC), 50/60Hz
Mounting Size (Main Board) 210*134*34mm
Sensor Type NTC(5KΩ/25°C,B value 3470K; 50K/25°C, B value 3490K)
Relay Output Capacity 10A/240VAC, 15A/250VAC
Certificates ISO9001, ROHS
Testing AOI Test

8. Warranty and Support

This product is covered by a standard manufacturer's warranty. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

For further assistance, refer to the official Tuya Smart app documentation or support resources for integration and smart home features.

9. User Tips

No specific user tips were available from reviews or Q&A for this product. However, general tips for heat pump controllers include:

  • Optimize Settings: Experiment with different temperature settings and timer schedules to find the most energy-efficient operation for your specific needs.
  • Monitor Performance: Regularly check the system's performance via the display or Tuya app to ensure it's operating as expected.
  • Professional Installation: Due to the electrical nature and complexity of heat pump systems, professional installation is highly recommended to ensure safety and proper function.

Related Documents - CCHW005

Preview Tuya WiFi Water Level Controller with Temperature Sensor User Manual
User manual for the Tuya WiFi Water Level Controller with Temperature Sensor. This document details features, specifications, wiring, and operation for smart water management and automation using the Tuya Smart or Smart Life mobile applications.
Preview Tuya BK7231S Chip Onboard Solution Wiring Instructions
Comprehensive wiring guide for the Tuya BK7231S chip onboard solution. Includes detailed pin descriptions, wiring tables, and test board setup for IoT development.
Preview WIFI Switch Module 1CH, 2CH, 3CH, 4CH: Instruction Manual & Installation Guide
This manual provides detailed instructions for installing and operating the 1CH, 2CH, 3CH, and 4CH Wi-Fi Switch Modules. It covers technical specifications, safety warnings, wiring diagrams for various configurations, a comprehensive FAQ section, and a guide to using the Tuya Smart App for smart home automation.
Preview Tuya Solar Camera Quick Start Guide: Setup, AP Mode, and Troubleshooting
Get your Tuya Solar Camera up and running with this comprehensive quick start guide. Learn about app installation, device connection, AP mode, PIR settings, and essential troubleshooting tips for optimal performance.
Preview Tuya V3 Waterproof Face Recognition Access Control Hardware Manual
Hardware specifications and details for the Tuya V3 series waterproof face recognition access control systems, including model variants, dimensions, weight, and card compatibility.
Preview T2-U Development Board: Technical Overview and Development Guide
This document provides a comprehensive overview of the Tuya T2-U Development Board, detailing its hardware features, communication capabilities (Wi-Fi, Bluetooth LE), development methods using TuyaOS, default firmware, and essential guides for flashing, debugging, and driver installation.