1. Introduction
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Dobtian AASD 130st Series AC Servo Motor Kit. Please read this manual thoroughly before using the product to ensure safe and efficient operation.
The AASD 130st Series AC Servo Motor Kit is designed for industrial automation, robotics DIY, simulator DIY, and family simracing applications, offering precise control and reliable performance.
Video: Overview of the AASD 130st Series AC Servo Motor Kit in operation and manufacturing process.
2. Safety Precautions
To ensure safe use and prevent injury or equipment damage, observe the following safety signs and instructions:
- Warning (▲): Indicates that incorrect operation may cause danger, mild or moderate bodily harm, equipment damage, or fire.
- Danger (▲): Indicates that incorrect operation may cause severe injury or death.
- Prohibition (🚫): Indicates a forbidden operation.
- Mandatory (❗): Indicates a required operation.
2.1. Notes on Installation
- Warning: Do not install in humid, corrosive, flammable gas, combustible material, dust, or metal powder environments to prevent electric shock or fire.
2.2. Precautions for Wiring
- Warning: The ground terminal of the servo driver must be earthed to prevent electric shock and fire.
- Danger: Do not connect the servo driver output terminals U, V, W to a three-phase power supply; this may cause injury or fire.
- Danger: Do not connect a 220V drive to a 380V power supply to prevent electric shock or fire.
- Mandatory: Ensure all power and motor terminals are tightened to prevent fire.
2.3. Considerations for Runtime
- Danger: Do not touch any rotating parts during operation to prevent injury.
- Danger: Do not touch the motor and drive during operation to prevent burns.
- Warning: Select the correct motor type and set appropriate user parameters before running to prevent injury or equipment damage.
- Mandatory: Ensure the machine can be stopped at any time to prevent injury.
2.4. Precautions for Maintenance and Inspection
- Prohibition: Do not touch the inside of the servo drive to prevent electric shock.
- Prohibition: After turning off the power, do not touch terminals for 5 minutes to prevent electric shock from residual voltage.
- Prohibition: Do not disassemble the servo motor to prevent electric shock.
3. Package Contents
The standard package for the AASD 130st Series AC Servo Motor Kit includes:
- 1 x Servo Motor
- 1 x Servo Driver
- 1 x 3-Meter Motor Cable
- 1 x 3-Meter Encoder Cable
- 1 x 25 Core Parallel Connection Cable

Image: Included cables for the servo motor kit.
4. Product Inspection
Upon receiving the product, perform the following checks before installation:
- Verify that the servo drive and motor models match your order.
- Inspect the servo drive and motor for any visible damage or scratches. Do not connect power if damage is found.
- Check for any loose parts or screws on the servo drive and motor. Ensure all screws are tightened.
- For motors without a brake, check that the rotor shaft rotates smoothly by hand. Motors with a brake cannot be rotated directly.
If any issues are found, contact your distributor immediately.
5. Product Front Panel
The front panel of the servo drive features a 5-digit LED display and four buttons for operation and monitoring.

Image: Front panel of the servo driver, showing the LED display, control buttons, and various connection ports (CN1, CN2, CN3).
Key Components:
- 5-bit LED Display: Shows operational status and parameter values.
- Four Buttons (MOD, ▲, ▼, SET): Used for mode selection, value adjustment, and parameter confirmation.
- L1, L2, L3 Terminals: AC220V input (single-phase or three-phase).
- U, V, W Terminals: Driver power output to motor.
- Ground Terminal: For earthing the device.
- External Regenerative Braking Resistor Terminals: For connecting an external braking resistor.
- CN1 Communication Interface: For RS-232 or RS-485 communication.
- CN2 Control Interface: For control signals (e.g., input/output commands).
- CN3 Encoder Interface: For encoder feedback.
6. Specifications
6.1. Driver Specifications
| Feature | Description |
|---|---|
| Input Power | Single-phase or three-phase AC220V (-15% to +10%) 50/60Hz; Single-phase or three-phase AC380V (-15% to +10%) 50/60Hz |
| Environment Temperature | Operating: 0~55°C; Storage: -20~80°C |
| Humidity | Below 90% RH (non-condensing) |
| Vibration | Below 0.5G (4.9m/S²), 10~60Hz (non-continuous running) |
| Control Mode | IGBT PWM sine wave control |
| Control Model | Torque mode (internal/external), Speed mode (internal/external), Position mode (internal/external), Position/Speed model, Position/Torque model, Speed/Torque model |
| Control Input | Servo enable, alarm reset, forward/reverse drive prohibited, external torque limits, emergency stop, zero speed clamp, internal speed/torque commands, control mode switching, gain switching, electronic gear selection, instruction inversion, position deviation clear, pulse input inhibit, proportional control, origin return trigger, origin return reference point, internal position selection, fixed length displacement interruption, fixed length unlocking |
| Control Output | Alarm detection, servo ready, emergency stop detection, positioning completed, speed reached, predetermined torque reached, zero speed examination, servo motor electrify, electromagnetic brake, origin return completed, position approach, torque limit, speed limit, tracking torque command arrives |
| Encoder Feedback | 2500 line incremental encoder or 17-bit absolute encoder |
| Communication Mode | RS-232 or RS-485 |
| Display and Operation | 5-digit LED display, four buttons |
| Braking Method | Energy consumption braking via internal/external braking resistor |
| Cooling Method | Air cooled (heat conduction mold, high-speed strong cooling fan) |
| Power Range | ≤7.5KW |
6.2. Motor Specifications (130ST Series)
| Model | Rated Power | Rated Voltage | Rated Current | Rated Speed | Rated Torque | Peak Torque | Line-line Resistance | Line-line Inductance |
|---|---|---|---|---|---|---|---|---|
| 130ST-M04025 | 1.0kw | 220V | 4.4A | 2500rpm | 4N.m | 12N.m | 1.83Ω | 4.72mH |
| 130ST-M05025 | 1.3kw | 220V | 5.0A | 2500rpm | 5N.m | 15N.m | 1.84Ω | 4.9mH |
| 130ST-M06015 | 0.95kw | 220V | 6.0A | 1500rpm | 6N.m | 18N.m | 1.21Ω | 3.87mH |
| 130ST-M06025 | 1.5kw | 220V | 6.0A | 2500rpm | 6N.m | 18N.m | 1.21Ω | 3.87mH |
| 130ST-M07725 | 2.0kw | 220V | 7.5A | 2500rpm | 7.7N.m | 22N.m | 1.01Ω | 2.94mH |
| 130ST-M10010 | 1.0kw | 220V | 4.5A | 1000rpm | 10N.m | 20N.m | 2.7Ω | 8.8mH |
| 130ST-M10015 | 1.5kw | 220V | 6.0A | 1500rpm | 10N.m | 25N.m | 1.29Ω | 5.07mH |
| 130ST-M10025 | 2.6kw | 220V | 10A | 2500rpm | 10N.m | 25N.m | 0.73Ω | 2.45mH |
| 130ST-M15015 | 2.3kw | 220V | 9.5A | 1500rpm | 15N.m | 30N.m | 1.1Ω | 4.45mH |
| 130ST-M15025 | 3.8kw | 220V | 13.5A | 2500rpm | 15N.m | 30N.m | 0.49Ω | 1.68mH |

Image: Example motor dimensions (Model: 110ST-M06030, Motor length: 219mm, with electromagnetic brake length: 293mm).
7. Setup and Installation
7.1. Installation Environment
- Temperature: Operating 0~40°C; Storage -40~50°C.
- Humidity: Below 80% RH (non-condensing).
- Vibration: Below 0.5G.
- Install in a well-ventilated place with little moisture and dust.
- Avoid corrosive, flammable gas, oil, cutting fluid, iron powder, etc.
- Avoid water vapor and direct sunlight.
7.2. Installation Method
- Horizontal Installation: To prevent liquids from entering the motor, position the cable outlet downwards.
- Vertical Mounting: If the motor shaft is mounted upwards with a reducer, ensure grease does not penetrate the motor shaft.
- Ensure sufficient motor shaft extension to prevent vibration during movement.
7.3. Motor Rotation Direction
When viewed from the motor load side, counterclockwise (CCW) rotation of the motor shaft is considered forward, and clockwise (CW) rotation is considered reverse.
7.4. Wiring Instructions
Always use wiring materials according to specifications. Instruction cables should be within 3m, and encoder cables within 20m.
7.4.1. 220V Servo Drive Wiring Diagram

Image: Wiring diagram for 220V AC servo drive system, showing connections for input power, motor, encoder, and control signals.
7.4.2. 380V Servo Drive Wiring Diagram

Image: Wiring diagram for 380V AC servo drive system, showing connections for input power, motor, encoder, and control signals.
7.4.3. Wire Specification
| Connection Terminal | Symbol | Wire Specification |
|---|---|---|
| Power Cord | U, V, W | 0.75~2.5mm² |
| Motor Connecting Terminal | 0.75~2.5mm² | |
| Ground Terminal | 0.75~2.5mm² | |
| Control Signal Terminal | CN2 | ≥0.12 mm² (AWG26), shielded wire |
| Encoder Signal Terminal | CN3 | ≥0.12 mm² (AWG26), shielded wire |
Note: Encoder cables must be twisted pair. If the encoder cable is too long (>20m), the encoder may have insufficient power supply, and the power and ground can be connected by multiple wires or using a thick wire.
7.4.4. Strong Terminal Description (220V Drive)
| Name | Terminal Symbol | Detailed Description |
|---|---|---|
| Main Circuit Power Supply | L1, L2, L3 | Connect external AC power, three-phase 220VAC -15% to +10% 50/60Hz. For single-phase power, connect to L1 and L2 terminals. |
| Motor Connecting Terminal | U, V, W | Output to the motor U, V, W phase power supply. |
| Ground Terminal | Motor housing earthing terminal, Driver ground terminal. |
7.4.5. Strong Terminal Description (380V Drive)
| Name | Terminal Symbol | Detailed Description |
|---|---|---|
| Control Circuit Power Supply | L1, L2 | Connect external AC power, three-phase 380VAC -15% to +10% 50/60Hz. |
| Braking Resistor Terminal | B1, B2, B+ | If internal braking resistor is used, short B2, B1. If external braking resistor is used, remove connections between B2 and B1, and connect resistor to B2 and B+. |
| Motor Connecting Terminal | U, V, W | Output to the motor U, V, W phase power supply. |
| Ground Terminal | FG | Motor housing earthing terminal, Driver ground terminal. |
7.4.6. Drive Control Wiring Diagram

Image: Drive Control Wiring Diagram, showing connections for KRS driver, power supply, control signals (CN1, CN2), and encoder (CN3).
8. Operation
8.1. Panel Operation
The servo drive features a 5-digit LED display and four buttons (MOD, ▲, ▼, SET) for operation. The MOD button is used for mode switching and returning to the higher directory. The ▲ and ▼ buttons are for increasing/decreasing values, with long press for repeat effect. The SET button is for digital shift, confirming settings, and ending parameter settings.
If the 5 decimal points of the display screen are all flashing, an alarm is present. Clear the alarm before proceeding with normal operation.
8.2. Operating Modes
The drive supports several operating modes, including Monitoring (Dn), Auxiliary (Fn), and User Parameter (Pn) modes.
- Monitoring Mode (Dn): Used to view various parameters and real-time status of the drive.
- Auxiliary Mode (Fn): Provides functions for alarm record query, parameter writing, JOG commissioning, alarm clearing, parameter initialization, position offset reset, and forced output.
- User Parameter Mode (Pn): Used to set and modify various operational parameters of the drive.
9. Parameter Settings (Pn Functions)
The servo drive has a wide range of configurable parameters (Pn000-Pn280) to customize its behavior for different applications. Parameters are categorized into System Control, Position Control, Speed Control, Torque Control, and Extended Control parameters.
Important Notes:
- Parameters marked with ▲ require a power cycle (re-energizing) to take effect.
- Parameters marked with ◆ require re-enabling the motor to take effect.
- Parameters without special symbols take effect immediately.
- Parameters must be set carefully. Improper settings can cause unstable motor operation.
For a detailed list and description of all Pn parameters, refer to the comprehensive PDF manual provided by the manufacturer.
10. Troubleshooting and Alarms
The servo drive is equipped with an alarm system to indicate operational issues. Alarms are displayed on the LED panel with an 'AL-xx' code. Refer to the table below for common alarms and their countermeasures.
10.1. Alarm Clearing
To clear an alarm, navigate to Auxiliary Mode (Fn) and select Fn003. Follow the on-screen instructions to clear the currently detected alarms.
10.2. Common Alarms and Countermeasures
| Alarm Code | Description | Countermeasures |
|---|---|---|
| AL-01 | Memory Exception | Initialize parameters (Fn004) and observe. If persistent, replace servo amplifier. |
| AL-02 | Low Voltage | Measure external power supply voltage, check consistency with display (Fn009), replace servo amplifier if internal components damaged. For large motor loads, use three-phase power supply. |
| AL-03 | Overvoltage | Measure external power supply voltage, check consistency with display (Fn009), replace servo amplifier if internal components damaged. |
| AL-04 | Intelligent Power Module Exception | Check motor wiring (U,V,W) for short circuits/ground faults. Check encoder wiring. If persistent, replace servo amplifier. Adjust speed/current loop parameters. |
| AL-05 | Overload 1 | Check motor/encoder wiring. Reduce acceleration/deceleration frequency. Reduce load inertia or use a higher power motor. |
| AL-06 | Overload 2 | Reduce acceleration/deceleration frequency. Reduce load inertia or use a higher power motor. |
| AL-07 | Motor Speed Too High | Check motor/encoder wiring. Reduce input pulse frequency or adjust electronic gear ratio. Adjust speed loop parameters. |
| AL-08 | Radiator Overheating | Change motor operation mode to reduce load. Ensure ambient temperature is below 60°C (recommended below 50°C). Check for braking average power overload. |
| AL-09 | Encoder Exception | Check encoder wiring for connection, solder joints, and power supply (5V±5%). |
| AL-10 | Pulse Frequency Too High | Reduce input pulse frequency. |
| AL-11 | Position Pulse Deviation Too Large | Check motor/encoder wiring. Adjust position instruction smoothing time. Increase position loop gain. Check if motor output torque is at its limit. Check for internal 32-bit pulse counter overflow. |
| AL-12 | Current Sampling Loop Damaged | Check for instantaneous current overload. Check motor wiring for loose connections or short circuits. Replace servo amplifier if sampling loop is damaged. |
| AL-13 | CPU Internal Fault | Reduce external interference. |
| AL-14 | Emergency Stop Signal Active | Check emergency stop wiring and ensure signal is normally closed (ON). |
| AL-15 | Drive Forbidden Exception | Check CCWL/CWL wiring and ensure signal is normally closed (ON). If not using drive forbidden function, mask it with Pn006. |
| AL-16 | Input Power Voltage Too High / Braking Load Rate Over 85% | Check input voltage. Reduce start/stop frequency. Use external regenerative braking resistor. Increase deceleration time. Check braking resistor power/resistance values. Replace motor/drive if necessary. |
| AL-17 | Improper Encoder Output Frequency Division | Reset Pn016/Pn017 parameters to satisfy DA/DB>=1. |
| AL-18 | Improper Motor Code Setting | Reset Pn001 according to the drive and motor model adaptation table. |
| AL-19 | Power Module Overheating | Cool down the module. Replace motor with higher capacity if overused. |
| AL-20 | Same Function Assigned to Multiple Input Ports | Remove duplicate settings for input ports. |
| AL-21 | Memory Contents Completely Destroyed | Initialize parameters (Fn004). If persistent, replace servo amplifier. |
| AL-22 | Watchdog Timer Overflow | Replace servo amplifier if persistent. Reduce external interference. |
| AL-23 | Current Zero Drift Anomaly | Replace servo amplifier if persistent. |
| AL-24 | Programmable Logic Chip Exception | Replace servo amplifier if persistent. Reduce external interference. |
| AL-25 | DSP Chip Abnormalities | Replace servo amplifier if persistent. |
| AL-26 | Unsupported Origin Regression Combination | Reset Pn034, Pn035. |
| AL-27 | External Braking Resistor Value Too Low | Select appropriate external braking resistor. |
| AL-28 | Braking Resistor Overload | Check braking load rate (Dn013). |
| AL-29 | Servo Short Duration Brake Abnormal | Check input voltage (Dn004). Check for loose wiring or missing braking resistor. |
| AL-31 | Absolute Encoder Battery Low Voltage | Replace battery immediately. |
| AL-32 | Absolute Encoder Battery Voltage Too Low | Check battery connection and voltage. Perform Fn015 to reset multi-circle information. |
| AL-33 | Absolute Encoder Multi-Turn Count Overflow | Perform Fn015 to reset multi-circle information. If not needed, set Pn219 to disable overflow detection. |
| AL-34 | Absolute Encoder Count Error | Re-power. |
| AL-35 | Absolute Encoder Power Error | Ensure motor is stationary or at low speed during power-on. |
| AL-36 | Absolute Encoder Multi-Turn Error | Perform Fn015 to reset multi-circle information. |
| AL-37 | Motor Overheating | Cool down the motor. |
| AL-38 | Absolute Encoder Detects Excessive Speed Alarm | Check battery. Perform Fn015 to reset multi-loop information. |
| AL-41 | Communication Fault, Absolute Encoder Without Response | Check encoder wiring, connections, and for damage. |
| AL-42 | Absolute Encoder Communication Errors | Check encoder wiring for length, interference, and damage. |
| AL-43 | Absolute Encoder Internal Storage Unit Data Error | Perform Fn017 to re-initialize data. |
| AL-44 | Absolute Encoder Frequency Divider Circuit Fault | Replace servo amplifier. |
| AL-45 | Reset, Absolute Encoder Multi-Turn Error Operation | Refer to AL-42 handling measures. |
| AL-46 | Reset, Absolute Encoder Single-Turn Error Operation | Refer to AL-42 handling measures. |
11. User Tips
While no specific user reviews or Q&A were provided, general tips for servo motor kits often include:
- Always ensure proper grounding to prevent electrical noise and ensure safety.
- Double-check all wiring connections before powering on to avoid damage.
- For optimal performance, carefully tune the gain parameters (Pn functions) according to your specific mechanical system.
- Regularly monitor the motor and driver temperature to prevent overheating, especially during demanding operations.
- Keep the installation environment clean and free from dust and moisture to prolong the lifespan of the components.
12. Warranty and Support
For warranty information and technical support, please refer to the official documentation provided with your purchase or contact your vendor. Ensure you retain your proof of purchase for any warranty claims.
A user manual (PDF) is available for more detailed item guides and documents. You can reference it at: User Manual (PDF)