1. Introduction

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Dobtian AASD 130st Series AC Servo Motor Kit. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

The AASD 130st Series AC Servo Motor Kit is designed for industrial automation, robotics DIY, simulator DIY, and family simracing applications, offering precise control and reliable performance.

Video: Overview of the AASD 130st Series AC Servo Motor Kit in operation and manufacturing process.

2. Safety Precautions

To ensure safe use and prevent injury or equipment damage, observe the following safety signs and instructions:

  • Warning (▲): Indicates that incorrect operation may cause danger, mild or moderate bodily harm, equipment damage, or fire.
  • Danger (▲): Indicates that incorrect operation may cause severe injury or death.
  • Prohibition (🚫): Indicates a forbidden operation.
  • Mandatory (❗): Indicates a required operation.

2.1. Notes on Installation

  • Warning: Do not install in humid, corrosive, flammable gas, combustible material, dust, or metal powder environments to prevent electric shock or fire.

2.2. Precautions for Wiring

  • Warning: The ground terminal of the servo driver must be earthed to prevent electric shock and fire.
  • Danger: Do not connect the servo driver output terminals U, V, W to a three-phase power supply; this may cause injury or fire.
  • Danger: Do not connect a 220V drive to a 380V power supply to prevent electric shock or fire.
  • Mandatory: Ensure all power and motor terminals are tightened to prevent fire.

2.3. Considerations for Runtime

  • Danger: Do not touch any rotating parts during operation to prevent injury.
  • Danger: Do not touch the motor and drive during operation to prevent burns.
  • Warning: Select the correct motor type and set appropriate user parameters before running to prevent injury or equipment damage.
  • Mandatory: Ensure the machine can be stopped at any time to prevent injury.

2.4. Precautions for Maintenance and Inspection

  • Prohibition: Do not touch the inside of the servo drive to prevent electric shock.
  • Prohibition: After turning off the power, do not touch terminals for 5 minutes to prevent electric shock from residual voltage.
  • Prohibition: Do not disassemble the servo motor to prevent electric shock.

3. Package Contents

The standard package for the AASD 130st Series AC Servo Motor Kit includes:

  • 1 x Servo Motor
  • 1 x Servo Driver
  • 1 x 3-Meter Motor Cable
  • 1 x 3-Meter Encoder Cable
  • 1 x 25 Core Parallel Connection Cable
Cables included with the Dobtian AASD 130st Series AC Servo Motor Kit

Image: Included cables for the servo motor kit.

4. Product Inspection

Upon receiving the product, perform the following checks before installation:

  1. Verify that the servo drive and motor models match your order.
  2. Inspect the servo drive and motor for any visible damage or scratches. Do not connect power if damage is found.
  3. Check for any loose parts or screws on the servo drive and motor. Ensure all screws are tightened.
  4. For motors without a brake, check that the rotor shaft rotates smoothly by hand. Motors with a brake cannot be rotated directly.

If any issues are found, contact your distributor immediately.

5. Product Front Panel

The front panel of the servo drive features a 5-digit LED display and four buttons for operation and monitoring.

Front panel of the Dobtian AASD servo driver

Image: Front panel of the servo driver, showing the LED display, control buttons, and various connection ports (CN1, CN2, CN3).

Key Components:

  • 5-bit LED Display: Shows operational status and parameter values.
  • Four Buttons (MOD, ▲, ▼, SET): Used for mode selection, value adjustment, and parameter confirmation.
  • L1, L2, L3 Terminals: AC220V input (single-phase or three-phase).
  • U, V, W Terminals: Driver power output to motor.
  • Ground Terminal: For earthing the device.
  • External Regenerative Braking Resistor Terminals: For connecting an external braking resistor.
  • CN1 Communication Interface: For RS-232 or RS-485 communication.
  • CN2 Control Interface: For control signals (e.g., input/output commands).
  • CN3 Encoder Interface: For encoder feedback.

6. Specifications

6.1. Driver Specifications

FeatureDescription
Input PowerSingle-phase or three-phase AC220V (-15% to +10%) 50/60Hz; Single-phase or three-phase AC380V (-15% to +10%) 50/60Hz
Environment TemperatureOperating: 0~55°C; Storage: -20~80°C
HumidityBelow 90% RH (non-condensing)
VibrationBelow 0.5G (4.9m/S²), 10~60Hz (non-continuous running)
Control ModeIGBT PWM sine wave control
Control ModelTorque mode (internal/external), Speed mode (internal/external), Position mode (internal/external), Position/Speed model, Position/Torque model, Speed/Torque model
Control InputServo enable, alarm reset, forward/reverse drive prohibited, external torque limits, emergency stop, zero speed clamp, internal speed/torque commands, control mode switching, gain switching, electronic gear selection, instruction inversion, position deviation clear, pulse input inhibit, proportional control, origin return trigger, origin return reference point, internal position selection, fixed length displacement interruption, fixed length unlocking
Control OutputAlarm detection, servo ready, emergency stop detection, positioning completed, speed reached, predetermined torque reached, zero speed examination, servo motor electrify, electromagnetic brake, origin return completed, position approach, torque limit, speed limit, tracking torque command arrives
Encoder Feedback2500 line incremental encoder or 17-bit absolute encoder
Communication ModeRS-232 or RS-485
Display and Operation5-digit LED display, four buttons
Braking MethodEnergy consumption braking via internal/external braking resistor
Cooling MethodAir cooled (heat conduction mold, high-speed strong cooling fan)
Power Range≤7.5KW

6.2. Motor Specifications (130ST Series)

ModelRated PowerRated VoltageRated CurrentRated SpeedRated TorquePeak TorqueLine-line ResistanceLine-line Inductance
130ST-M040251.0kw220V4.4A2500rpm4N.m12N.m1.83Ω4.72mH
130ST-M050251.3kw220V5.0A2500rpm5N.m15N.m1.84Ω4.9mH
130ST-M060150.95kw220V6.0A1500rpm6N.m18N.m1.21Ω3.87mH
130ST-M060251.5kw220V6.0A2500rpm6N.m18N.m1.21Ω3.87mH
130ST-M077252.0kw220V7.5A2500rpm7.7N.m22N.m1.01Ω2.94mH
130ST-M100101.0kw220V4.5A1000rpm10N.m20N.m2.7Ω8.8mH
130ST-M100151.5kw220V6.0A1500rpm10N.m25N.m1.29Ω5.07mH
130ST-M100252.6kw220V10A2500rpm10N.m25N.m0.73Ω2.45mH
130ST-M150152.3kw220V9.5A1500rpm15N.m30N.m1.1Ω4.45mH
130ST-M150253.8kw220V13.5A2500rpm15N.m30N.m0.49Ω1.68mH
Motor dimensions diagram for 110ST-M06030 model

Image: Example motor dimensions (Model: 110ST-M06030, Motor length: 219mm, with electromagnetic brake length: 293mm).

7. Setup and Installation

7.1. Installation Environment

  • Temperature: Operating 0~40°C; Storage -40~50°C.
  • Humidity: Below 80% RH (non-condensing).
  • Vibration: Below 0.5G.
  • Install in a well-ventilated place with little moisture and dust.
  • Avoid corrosive, flammable gas, oil, cutting fluid, iron powder, etc.
  • Avoid water vapor and direct sunlight.

7.2. Installation Method

  • Horizontal Installation: To prevent liquids from entering the motor, position the cable outlet downwards.
  • Vertical Mounting: If the motor shaft is mounted upwards with a reducer, ensure grease does not penetrate the motor shaft.
  • Ensure sufficient motor shaft extension to prevent vibration during movement.

7.3. Motor Rotation Direction

When viewed from the motor load side, counterclockwise (CCW) rotation of the motor shaft is considered forward, and clockwise (CW) rotation is considered reverse.

7.4. Wiring Instructions

Always use wiring materials according to specifications. Instruction cables should be within 3m, and encoder cables within 20m.

7.4.1. 220V Servo Drive Wiring Diagram

220V Servo Drive Wiring Diagram

Image: Wiring diagram for 220V AC servo drive system, showing connections for input power, motor, encoder, and control signals.

7.4.2. 380V Servo Drive Wiring Diagram

380V Servo Drive Wiring Diagram

Image: Wiring diagram for 380V AC servo drive system, showing connections for input power, motor, encoder, and control signals.

7.4.3. Wire Specification

Connection TerminalSymbolWire Specification
Power CordU, V, W0.75~2.5mm²
Motor Connecting Terminal0.75~2.5mm²
Ground Terminal0.75~2.5mm²
Control Signal TerminalCN2≥0.12 mm² (AWG26), shielded wire
Encoder Signal TerminalCN3≥0.12 mm² (AWG26), shielded wire

Note: Encoder cables must be twisted pair. If the encoder cable is too long (>20m), the encoder may have insufficient power supply, and the power and ground can be connected by multiple wires or using a thick wire.

7.4.4. Strong Terminal Description (220V Drive)

NameTerminal SymbolDetailed Description
Main Circuit Power SupplyL1, L2, L3Connect external AC power, three-phase 220VAC -15% to +10% 50/60Hz. For single-phase power, connect to L1 and L2 terminals.
Motor Connecting TerminalU, V, WOutput to the motor U, V, W phase power supply.
Ground TerminalMotor housing earthing terminal, Driver ground terminal.

7.4.5. Strong Terminal Description (380V Drive)

NameTerminal SymbolDetailed Description
Control Circuit Power SupplyL1, L2Connect external AC power, three-phase 380VAC -15% to +10% 50/60Hz.
Braking Resistor TerminalB1, B2, B+If internal braking resistor is used, short B2, B1. If external braking resistor is used, remove connections between B2 and B1, and connect resistor to B2 and B+.
Motor Connecting TerminalU, V, WOutput to the motor U, V, W phase power supply.
Ground TerminalFGMotor housing earthing terminal, Driver ground terminal.

7.4.6. Drive Control Wiring Diagram

Drive Control Wiring Diagram

Image: Drive Control Wiring Diagram, showing connections for KRS driver, power supply, control signals (CN1, CN2), and encoder (CN3).

8. Operation

8.1. Panel Operation

The servo drive features a 5-digit LED display and four buttons (MOD, ▲, ▼, SET) for operation. The MOD button is used for mode switching and returning to the higher directory. The ▲ and ▼ buttons are for increasing/decreasing values, with long press for repeat effect. The SET button is for digital shift, confirming settings, and ending parameter settings.

If the 5 decimal points of the display screen are all flashing, an alarm is present. Clear the alarm before proceeding with normal operation.

8.2. Operating Modes

The drive supports several operating modes, including Monitoring (Dn), Auxiliary (Fn), and User Parameter (Pn) modes.

  • Monitoring Mode (Dn): Used to view various parameters and real-time status of the drive.
  • Auxiliary Mode (Fn): Provides functions for alarm record query, parameter writing, JOG commissioning, alarm clearing, parameter initialization, position offset reset, and forced output.
  • User Parameter Mode (Pn): Used to set and modify various operational parameters of the drive.

9. Parameter Settings (Pn Functions)

The servo drive has a wide range of configurable parameters (Pn000-Pn280) to customize its behavior for different applications. Parameters are categorized into System Control, Position Control, Speed Control, Torque Control, and Extended Control parameters.

Important Notes:

  • Parameters marked with ▲ require a power cycle (re-energizing) to take effect.
  • Parameters marked with ◆ require re-enabling the motor to take effect.
  • Parameters without special symbols take effect immediately.
  • Parameters must be set carefully. Improper settings can cause unstable motor operation.

For a detailed list and description of all Pn parameters, refer to the comprehensive PDF manual provided by the manufacturer.

10. Troubleshooting and Alarms

The servo drive is equipped with an alarm system to indicate operational issues. Alarms are displayed on the LED panel with an 'AL-xx' code. Refer to the table below for common alarms and their countermeasures.

10.1. Alarm Clearing

To clear an alarm, navigate to Auxiliary Mode (Fn) and select Fn003. Follow the on-screen instructions to clear the currently detected alarms.

10.2. Common Alarms and Countermeasures

Alarm CodeDescriptionCountermeasures
AL-01Memory ExceptionInitialize parameters (Fn004) and observe. If persistent, replace servo amplifier.
AL-02Low VoltageMeasure external power supply voltage, check consistency with display (Fn009), replace servo amplifier if internal components damaged. For large motor loads, use three-phase power supply.
AL-03OvervoltageMeasure external power supply voltage, check consistency with display (Fn009), replace servo amplifier if internal components damaged.
AL-04Intelligent Power Module ExceptionCheck motor wiring (U,V,W) for short circuits/ground faults. Check encoder wiring. If persistent, replace servo amplifier. Adjust speed/current loop parameters.
AL-05Overload 1Check motor/encoder wiring. Reduce acceleration/deceleration frequency. Reduce load inertia or use a higher power motor.
AL-06Overload 2Reduce acceleration/deceleration frequency. Reduce load inertia or use a higher power motor.
AL-07Motor Speed Too HighCheck motor/encoder wiring. Reduce input pulse frequency or adjust electronic gear ratio. Adjust speed loop parameters.
AL-08Radiator OverheatingChange motor operation mode to reduce load. Ensure ambient temperature is below 60°C (recommended below 50°C). Check for braking average power overload.
AL-09Encoder ExceptionCheck encoder wiring for connection, solder joints, and power supply (5V±5%).
AL-10Pulse Frequency Too HighReduce input pulse frequency.
AL-11Position Pulse Deviation Too LargeCheck motor/encoder wiring. Adjust position instruction smoothing time. Increase position loop gain. Check if motor output torque is at its limit. Check for internal 32-bit pulse counter overflow.
AL-12Current Sampling Loop DamagedCheck for instantaneous current overload. Check motor wiring for loose connections or short circuits. Replace servo amplifier if sampling loop is damaged.
AL-13CPU Internal FaultReduce external interference.
AL-14Emergency Stop Signal ActiveCheck emergency stop wiring and ensure signal is normally closed (ON).
AL-15Drive Forbidden ExceptionCheck CCWL/CWL wiring and ensure signal is normally closed (ON). If not using drive forbidden function, mask it with Pn006.
AL-16Input Power Voltage Too High / Braking Load Rate Over 85%Check input voltage. Reduce start/stop frequency. Use external regenerative braking resistor. Increase deceleration time. Check braking resistor power/resistance values. Replace motor/drive if necessary.
AL-17Improper Encoder Output Frequency DivisionReset Pn016/Pn017 parameters to satisfy DA/DB>=1.
AL-18Improper Motor Code SettingReset Pn001 according to the drive and motor model adaptation table.
AL-19Power Module OverheatingCool down the module. Replace motor with higher capacity if overused.
AL-20Same Function Assigned to Multiple Input PortsRemove duplicate settings for input ports.
AL-21Memory Contents Completely DestroyedInitialize parameters (Fn004). If persistent, replace servo amplifier.
AL-22Watchdog Timer OverflowReplace servo amplifier if persistent. Reduce external interference.
AL-23Current Zero Drift AnomalyReplace servo amplifier if persistent.
AL-24Programmable Logic Chip ExceptionReplace servo amplifier if persistent. Reduce external interference.
AL-25DSP Chip AbnormalitiesReplace servo amplifier if persistent.
AL-26Unsupported Origin Regression CombinationReset Pn034, Pn035.
AL-27External Braking Resistor Value Too LowSelect appropriate external braking resistor.
AL-28Braking Resistor OverloadCheck braking load rate (Dn013).
AL-29Servo Short Duration Brake AbnormalCheck input voltage (Dn004). Check for loose wiring or missing braking resistor.
AL-31Absolute Encoder Battery Low VoltageReplace battery immediately.
AL-32Absolute Encoder Battery Voltage Too LowCheck battery connection and voltage. Perform Fn015 to reset multi-circle information.
AL-33Absolute Encoder Multi-Turn Count OverflowPerform Fn015 to reset multi-circle information. If not needed, set Pn219 to disable overflow detection.
AL-34Absolute Encoder Count ErrorRe-power.
AL-35Absolute Encoder Power ErrorEnsure motor is stationary or at low speed during power-on.
AL-36Absolute Encoder Multi-Turn ErrorPerform Fn015 to reset multi-circle information.
AL-37Motor OverheatingCool down the motor.
AL-38Absolute Encoder Detects Excessive Speed AlarmCheck battery. Perform Fn015 to reset multi-loop information.
AL-41Communication Fault, Absolute Encoder Without ResponseCheck encoder wiring, connections, and for damage.
AL-42Absolute Encoder Communication ErrorsCheck encoder wiring for length, interference, and damage.
AL-43Absolute Encoder Internal Storage Unit Data ErrorPerform Fn017 to re-initialize data.
AL-44Absolute Encoder Frequency Divider Circuit FaultReplace servo amplifier.
AL-45Reset, Absolute Encoder Multi-Turn Error OperationRefer to AL-42 handling measures.
AL-46Reset, Absolute Encoder Single-Turn Error OperationRefer to AL-42 handling measures.

11. User Tips

While no specific user reviews or Q&A were provided, general tips for servo motor kits often include:

  • Always ensure proper grounding to prevent electrical noise and ensure safety.
  • Double-check all wiring connections before powering on to avoid damage.
  • For optimal performance, carefully tune the gain parameters (Pn functions) according to your specific mechanical system.
  • Regularly monitor the motor and driver temperature to prevent overheating, especially during demanding operations.
  • Keep the installation environment clean and free from dust and moisture to prolong the lifespan of the components.

12. Warranty and Support

For warranty information and technical support, please refer to the official documentation provided with your purchase or contact your vendor. Ensure you retain your proof of purchase for any warranty claims.

A user manual (PDF) is available for more detailed item guides and documents. You can reference it at: User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.