Acrel ACR320EL

Contents

Acrel ACR320EL Multi-Function Meter User Manual

Model: ACR320EL Series

Brand: Acrel

1. Introduction

The Acrel ACR320EL is a high-precision multi-function power meter designed for comprehensive electrical parameter measurement and centralized remote monitoring. It supports three-phase current and voltage measurement, energy statistics, and features RS485 communication for integration into larger systems. This manual provides essential information for the safe installation, operation, and maintenance of your ACR320EL meter.

2. Safety Information

Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

  • Installation and maintenance should only be performed by qualified personnel.
  • Ensure power is disconnected before performing any wiring or installation procedures.
  • Verify correct wiring according to the provided diagrams to prevent damage to the meter or connected equipment.
  • Do not operate the meter in environments exceeding its specified operating conditions (temperature, humidity).
  • Protect the device from moisture, dust, and corrosive substances.
  • Release any static electricity before handling the device.

3. Product Overview

3.1 Features

  • Three-phase current measurement
  • Voltage measurement
  • LED/LCD display with backlight
  • RS485 communication interface
  • Maximum demand record
  • Time-of-use energy statistics
  • 12-month energy statistics
  • Event record
List of features for Acrel multi-function meter
Figure 3.1: Key Features of the Acrel Meter

3.2 Components

The meter consists of a front panel with an LCD display and control buttons, and a rear panel with various terminals for power input, current/voltage inputs, pulse output, analog output, and RS485 communication.

Front view of the Acrel ACR320EL multi-function meter
Figure 3.2: Front View of ACR320EL
Rear view of the Acrel ACR320EL multi-function meter showing terminal connections
Figure 3.3: Rear View with Terminal Layout

4. Specifications

AttributeValue
DIY SuppliesElectrical
OriginMainland China
High-concerned chemicalNone
Current Transformer (CT) Accuracy0.5s class (compatible with 1.5A and 6A CTs)

4.1 Dimensions

The ACR series meters come in various sizes. Please refer to the specific model for exact dimensions.

  • ACR120 Series: 84mm (W) x 84mm (H) x 92mm (D)
  • ACR220 Series: 96mm (W) x 96mm (H) x 95mm (D)
  • ACR320 Series: 120mm (W) x 120mm (H) x 92mm (D)
Dimensional drawings for ACR120, ACR220, and ACR320 series meters
Figure 4.1: ACR Series Product Dimensions

5. Setup and Installation

Follow these steps for proper installation of the meter into a panel:

  1. If the panel does not have a pre-cut opening, create a suitable hole according to the meter's dimensions.
  2. Before handling, discharge any static electricity. Remove the installation terminals from the meter.
  3. Insert the meter into the panel opening.
  4. Use the two provided mounting brackets to secure the device firmly to the installation panel. The brackets have a locking function to ensure a stable fit.
Four-step diagram illustrating the panel mounting process for the Acrel meter
Figure 5.1: Installation Diagram

6. Wiring Diagram

Proper wiring is critical for the safe and accurate operation of the meter. Refer to the diagrams below for common wiring configurations. Always ensure power is off before making any connections.

6.1 Low Voltage Three-Phase Four-Wire Connection

Wiring diagram for a low voltage three-phase four-wire system with the Acrel meter
Figure 6.1: Low Voltage Three-Phase Four-Wire Wiring

6.2 High Voltage Three-Phase Three-Wire Connection

For high voltage three-phase three-wire connections, consult the detailed wiring instructions provided with your specific model or contact technical support for guidance. The meter supports configuration for different wiring modes.

7. Operation

The ACR320EL meter features an LCD display and four control buttons for navigation and configuration.

Front panel of the Acrel meter showing LCD display and control buttons
Figure 7.1: Front Panel and Button Functions

7.1 Button Functions

  • SET Button: Press this button to enter the programming mode for configuration.
  • Left Arrow Button: Used for navigating menus or decreasing values.
  • Right Arrow Button: Used for navigating menus or increasing values.
  • Enter Button (Return/Confirm): Used to confirm selections or exit menus.

7.2 Display Navigation

The LCD display shows various electrical parameters. Use the arrow buttons to scroll through different measurement screens (e.g., voltage, current, power, energy). The SET button allows access to configuration menus where parameters like CT ratio, wiring mode, and time-of-use settings can be adjusted.

8. Maintenance

To ensure the longevity and accurate performance of your Acrel ACR320EL meter, follow these maintenance guidelines:

  • Cleaning: Regularly clean the meter's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the operating environment remains within specified temperature and humidity ranges. Avoid exposure to direct sunlight, excessive heat, or extreme cold.
  • Connection Checks: Periodically inspect all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to inaccurate readings or device malfunction.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or add new features. Follow update instructions carefully.
  • Calibration: If you suspect inaccurate readings, professional calibration may be required. Contact Acrel technical support for assistance.

9. Troubleshooting (FAQ)

This section addresses common questions and issues you might encounter.

Q: Can the time-of-use tariff periods and regions be changed on-site if they were incorrectly set at purchase?
A: Yes, these settings can be modified on-site through the meter's programming interface.
Q: The meter was configured for a 5A current transformer (CT) input, but the on-site CT ratio is 1A. Can the meter be adjusted for this?
A: The meter's accuracy is 0.5s class, and it is generally compatible with current transformers of 1.5A (6A) ratings. The meter's settings can typically be adjusted to match various CT ratios within its operational range. Consult the programming manual for specific CT ratio configuration steps.
Q: The meter was supplied for a three-phase four-wire system, but the on-site installation is three-phase three-wire. Can the meter be reconfigured?
A: Yes, the meter allows for switching between different wiring modes (e.g., three-phase three-wire, three-phase four-wire) through its internal settings in programming mode.
Frequently Asked Questions regarding Acrel energy meters
Figure 9.1: Common Troubleshooting Questions

10. User Tips

  • Configuration Flexibility: The meter offers significant flexibility in adjusting parameters like time-of-use tariffs, current transformer ratios, and wiring modes. Take advantage of these settings to precisely match your installation requirements.
  • Documentation: Keep this manual and any supplementary programming guides handy for quick reference during setup and operation.
  • System Integration: For advanced applications, familiarize yourself with the RS485 communication protocol to effectively integrate the meter into your centralized remote monitoring system.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official Acrel website or contact your authorized dealer. Ensure you have your product model and serial number available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.