1. Introduction
The GROW GM861/GM861-LED Bar Code Reader Module is a high-performance scanner capable of reading both 1D and 2D barcodes with high speed. It utilizes an advanced image recognition algorithm for easy and accurate barcode decoding, simplifying secondary development. The module supports both USB and UART interfaces.
For detailed version information and unique device ID, please refer to the complete user manual PDF available at: User Manual (PDF).
Video: Overview and demonstration of the GROW GM861-LED Barcode Scanner Module's scanning capabilities.
2. Specifications
2.1 Technical Specifications
| Parameter | Performance |
|---|---|
| Sensor | CMOS |
| Scan Mode | 640*480 |
| GM861-LED Indicator Light | White light as power on, Green light as read successfully |
| GM861-LED Fill Light | White light |
| 1D Read Code Type | EAN-13, EAN-8, UPC-A, UPC-E, ISSN, ISBN, CodaBar, Code 128, Code93, ITF-14, ITF-6, Interleaved 2 of 5, Industrial 2 of 5, Matrix 2 of 5, Code 39, Code 11, MSI-Plessey, GS1 Composite, GS1-Databar (RSS) |
| 2D Read Code Type | QR Code, Data Matrix, PDF417, Micro QR, Micro PDF417, Aztec |
| GM861/GM861-LED Reading Distance | 5-30cm |
| Contrast | >25% |
| Scan Angle | Roll: 360°, Pitch: 65°, Yaw: 65° |
| Viewing Angle | 67° (Horizontal) 53° (Vertical) |
| Accuracy of reading | ≥10mil |
2.2 Mechanical/Electrical Parameters
| Parameter | Performance |
|---|---|
| Interface | TTL-232/USB |
| Size (mm) | External diameter: 28mm, Internal diameter: 25mm, Height: 15mm, Thread M25 |
| Weight | 25 g |
| Prompting mode | LED Indicator |
| Operating Voltage | 3.3V |
| Operation Current | 70mA (Max) |
| Standby Current | ≤6mA (Typical) |
| Startup time | ≤250mS (Typical) |
2.3 Environmental Parameters
| Parameter | Performance |
|---|---|
| Operating temperature | -20°C ~ +60°C |
| Storage Temperature | -40°C ~ +70°C |
| Operating Humidity | 5% ~ 95% (Non-Condensing) |
| Environmental Light | Normal indoor light source |
| Fall | Withstand 1.2 m drop on concrete floor (50 times repeatedly) |
2.4 Default Read Configuration (Supported Barcode Types)
| Type | Name | Support | Default Read |
|---|---|---|---|
| 2D | QR Code | ✓ | ✓ |
| Data Matrix | ✓ | ✓ | |
| PDF417 | ✓ | ✓ | |
| Micro QR | ✓ | X | |
| Micro PDF417 | ✓ | X | |
| Aztec | ✓ | X | |
| 1D | EAN-13 | ✓ | ✓ |
| EAN-8 | ✓ | ✓ | |
| UPC-A | ✓ | ✓ | |
| UPC-E | ✓ | ✓ | |
| ISSN | ✓ | X | |
| ISBN | ✓ | X | |
| CodaBar | ✓ | X | |
| Code 128 | ✓ | ✓ | |
| Code93 | ✓ | X | |
| ITF-14 | ✓ | X | |
| ITF-6 | ✓ | X | |
| Interleaved 2 of 5 | ✓ | X | |
| Industrial 2 of 5 | ✓ | X | |
| Matrix 2 of 5 | ✓ | X | |
| GS1 Databar (RSS) | ✓ | X | |
| Code 39 | ✓ | X | |
| Code 11 | ✓ | X | |
| MSI-Plessey | ✓ | X |
3. Setup and Installation
3.1 Electrical Characteristics & Power Supply
The power supply for the module is DC +3.3V. Ensure the module is properly connected before applying power. To prevent damage, always switch off the power supply when inserting or removing cables. Maintain a stable power supply and wait at least two seconds after power-off before turning it back on. The recommended ripple noise should not exceed 50mV (peak-to-peak) for stable operation.
3.2 Dimensions & Pin Definition
The module has an external diameter of 28mm, an internal diameter of 25mm, and a height of 15mm with an M25 thread.

Image: GM861-LED Barcode Scanner Module with key dimensions.
The GM861/GM861-LED interface uses an SH1.0mm 6pin connector. The pin definitions are as follows:
| No. | Definition | Instruction |
|---|---|---|
| 1 | VCC | Power input 3.3V |
| 2 | TXD | Serial port send signal (TTL Level) |
| 3 | RXD | Serial port receiver signal (TTL Level) |
| 4 | GND | Signal ground |
| 5 | D- | USB data input |
| 6 | D+ | USB data output |

Image: GM861/GM861-LED Interface Definition (SH1.0mm 6pin). Note: The line order has nothing to do with color.
3.3 Communication Interface Configuration
The module communicates with a mainframe (PC, POS) via a serial communication interface. Ensure communication parameters are identical for both devices. The default serial communication parameters are: Baud rate 9600bps, No check, 8 bit data, 1 bit stop bit, No flow control.
3.3.1 Serial Port Settings
- Baud Rate: Can be configured by scanning specific QR codes for 1200bps, 4800bps, 9600bps (Default), 14400bps, 19200bps, 38400bps, 57600bps, 115200bps.
- Parity Bit: Configure by scanning QR codes for NONE (default), ODD, or EVEN.
- Serial Port Calibration: Send heartbeat packets (7E 00 0A 01 00 00 00 30 1A) every 10 seconds to ensure data accuracy. Expected return command: 03 00 00 01 00 33 31.
3.3.2 USB HID Interface
To configure the module as a HID device when connected to a PC via USB, scan the appropriate QR code. The HID device can be configured as:
- HID-KBW (Keyboard Wedge): Scan the *HIDKBW QR code. Data can also be output through the serial port simultaneously if enabled.
- HID-POS (Point of Sale): Scan the HIDPOS QR code.
- HID Parameter Configuration: Adjust PC access cycle for HID devices (1ms, 3ms, 5ms, 10ms).
- USB Virtual Serial Port: Scan the QR code to enable virtual serial port output.
3.4 Module Configuration via Setup Codes
The module's functions can be enabled or disabled by scanning specific setup codes (QR codes) or sending serial commands.
- Enable/Disable Setting Code Function: Send serial command `_SET_CODE_ON` or `_SET_CODE_OFF` followed by `7E 00 09 01 00 00 00 AB CD` to save.
- Save and Cancel: Scan specific QR codes to save current settings, cancel the last read byte, cancel all read bytes, or cancel changes.
- Reset to Factory Settings: Scan the designated QR code to restore the module to its factory default settings.
- User Default Settings: Scan QR codes to save current configurations as user defaults or restore to previously saved user defaults.
4. Operation Modes
4.1 Read Modes
- Continuous Mode: The module continuously reads barcodes. Break time between reads can be configured (0.1-25.5s, default 1.0s). Time settlement for a single read (0.1-25.5s, default 5s) determines the longest time before no-read time.
- Induction Mode: The module monitors brightness and reads when a scene change is detected. After a successful read or timeout, it returns to monitoring. Image stabilization time (0-25.5s, default 0s) and sensitivity can be adjusted.
- Manual Mode: This is the default mode. Reading is triggered by a toggle key press and stops upon output or key release.
- Command Triggered Mode: The module reads upon receiving a scan command from the mainframe and stops upon output or read timeout.
- POS Mode: Configures the module for Point of Sale applications, typically using command trigger mode, serial port communication, and with startup/ending character tones turned off.
4.2 Read Area
- Full Width Area: The module scans the entire field of view, prioritizing the center.
- Central Area Only: Barcodes must be within a defined central area to be identified. The size of this central area can be set as a percentage (1-100%) of the image width/height.
4.3 Lighting
The GM861-LED module features a white fill light (head lamp) for illumination.
- Normal (Default): Head lamp turns on when reading, off otherwise.
- Normally On: Head lamp is always on after boot.
- OFF: Head lamp is always off.

Image: GM861-LED Barcode Scanner Module with white fill lighting.
4.4 Prompts
The module provides sound prompts for various events.
- Sound Prompts: Configure passive or active buzzer, and buzzer drive frequency (high, medium, low).
- All Prompts Tone: Silence all prompt tones or enable them.
- Start-up Tone: Enable or disable the start-up tone.
- Read Code Prompts Tone: Configure prompt tones for successful reads, including duration time (default 60ms).
4.5 Data Edition
Data can be edited before output to facilitate separation and processing. This includes adding prefixes, AIM ID, CodeID, suffixes, cutting data, and adding 'Tail' characters. The output sequence is: [Prefix] [AIM ID] [CodeID] [Data] [Suffix] [Tail].
- Prefix/Suffix: Add or change custom prefixes/suffixes (max 15 characters, ASCII).
- AIM ID/CODE ID: Identify different barcode types. AIM ID is standard, CODE ID is user-definable.
- Cut out Data: Output specific parts of the data (whole, start, end, center) and change their lengths.
- Tail: Add a tail character (e.g., CR, TAB, CRLF) to distinguish decoding results.
- RF Information: Self-define output information when a read fails.
- Output Protocol: Modify the output format in serial/virtual serial mode (pure data or with protocol).
4.6 Barcode Type Configuration
Enable or disable specific barcode types for decoding. Options include supporting all, forbidding all, or enabling default types. Reading ability can be strengthened for improved performance with certain angles or contrasts.
Detailed configurations are available for numerous 1D and 2D barcode types, including EAN13, ISSN, ISBN, EAN8, UPCA, UPC-E, Code128, Code39, Code93, CodeBar, Interleaved 2 of 5, ITF-14, ITF-6, Industrial 2 of 5, Matrix 2 of 5, Code 11, MSI-Plessey, GS1-Databar (RSS), GS1 Composite, Micro QR Code, QR Code, Data Matrix, PDF417, Micro PDF417, and Aztec Code. Each type offers settings for enabling/disabling, transfer check characters, extra-codes, output modes, and minimum/maximum lengths.
4.7 Image Control
Configure black and white flip for one-dimensional and two-dimensional barcode decoding.
5. Maintenance
To ensure optimal performance and longevity of your GROW Bar Code Reader Module, follow these maintenance guidelines:
- Cleaning: Keep the lens and surrounding area clean from dust and debris. Use a soft, lint-free cloth, possibly dampened with a mild cleaning solution if necessary. Avoid abrasive materials or harsh chemicals.
- Environmental Conditions: Operate the module within the specified environmental parameters (temperature, humidity) to prevent damage.
- Cable Integrity: Regularly inspect the interface cables (USB, UART) for any signs of wear, fraying, or damage. Replace damaged cables immediately to ensure reliable connection and prevent electrical issues.
- Firmware Updates: Check the manufacturer's website or documentation for any available firmware updates. Keeping the firmware up-to-date can improve performance, add new features, or fix bugs.
6. Troubleshooting
If you encounter issues with your GROW Bar Code Reader Module, consider the following:
- No Read/Poor Read Performance:
- Ensure the module is properly powered (DC +3.3V) and the power supply is stable.
- Check cable connections for secure fit and integrity.
- Verify that the barcode is within the optimal reading distance (5-30cm) and angle.
- Clean the module's lens.
- Ensure the barcode type is enabled in the module's configuration.
- Adjust lighting conditions; ensure sufficient illumination for the barcode.
- If using 'Central Area Only' mode, ensure the barcode is within the defined central area.
- Communication Issues:
- Verify that the communication parameters (baud rate, parity, data bits, stop bits) match between the module and the mainframe.
- If using USB HID, ensure the correct HID type (KBW or POS) is selected.
- Check the serial port calibration using heartbeat packets.
- Incorrect Data Output:
- Review data edition settings (prefix, suffix, cut out data, tail) to ensure they are configured as desired.
- Check keyboard settlement settings if outputting to a keyboard interface.
- Verify the output data code format (GBK, UTF8, RAW).
- Module Not Responding:
- Perform a reset to factory settings.
- Check power supply.
- If the module enters sleep mode, ensure it is awakened by the appropriate trigger.
7. User Tips
- Optimize for Environment: If scanning in low-light conditions, utilize the white fill lighting feature. For very bright environments, consider adjusting the contrast settings if available through advanced configuration.
- Customization for Efficiency: Take advantage of the data edition features (prefix, suffix, data cutting) to format scanned data exactly as needed for your application, reducing post-processing.
- Power Stability is Key: Always ensure a stable 3.3V DC power supply. Fluctuations can lead to erratic behavior or damage. If possible, use a regulated power source with low ripple noise.
- Test Communication: When integrating, use the serial port calibration heartbeat packets to confirm reliable communication before deploying the module in a critical application.
- Experiment with Read Modes: Depending on your application (e.g., continuous scanning on an assembly line vs. manual scanning at a checkout), experiment with Continuous, Induction, and Manual read modes to find the most efficient setting.
8. Support
For further assistance, detailed technical documentation, or specific inquiries, please refer to the official user manual PDF or contact the manufacturer.
Official User Manual (PDF): View Item Guides & Documents
Manufacturer: Hangzhou Grow Technology Co., Ltd.
Contact: winni@hzgrow.com
Official Web: www.hzgrow.com