STEPPERONLINE DSY-RS400L2B2-M17S

Contents

STEPPERONLINE 400W RS485 DC Servo Motor Kit

User Manual

Model: DSY-RS400L2B2-M17S

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the STEPPERONLINE DSY series DC Servo System. This kit includes a 48VDC 400W servo motor with a 24V 7.3W brake and a 24-70VDC 400W servo driver. The servo motor features a rated torque of 1.27Nm, a peak torque of 3.81Nm, and a rated speed of 3000rpm.

The system comes standard with a 17-bit single-turn magnetic incremental encoder and utilizes a high power density design, enabling strong power output in a compact size, with up to 3 times instantaneous overload capability. The advanced magnetic circuit design minimizes torque ripple, reducing vibration and ensuring smoother torque output during operation.

This servo system is suitable for a wide range of applications, including mobile robots (AMR, AGV), service robots, special robots, logistics warehousing and sorting, medical equipment, instruments, and light textile industries, particularly where voltage and size constraints are critical factors.

2. Package Contents

The following items are included in your STEPPERONLINE 400W RS485 DC Servo Motor Kit:

  • 1 x DSY-400RS: 400W Pulse/RS485 DC Servo Motor Driver
  • 1 x DSY60-400L2B2M17S: 400W 48V DC Servo Motor 3000rpm 1.27Nm with Brake 17-Bit Encoder IP65
  • 1 x P1-DS-03P15M: 3.0m Motor Cable
  • 1 x P1-DS-03M-S: 3.0m Brake Cable
  • 1 x E2-DS-03AM: 3.0m Encoder Cable
  • 1 x RS232-5: 1.0m Debugging Cable
STEPPERONLINE 400W RS485 DC Servo Motor Kit components: servo motor, servo driver, and cables.

Figure 2.1: Overview of the servo motor kit components.

3. Specifications

3.1 Servo Driver (DSY-400RS)

Parameter Value
Part NumberDSY-400RS
Continuous Output Current15.0 A
Maximum Output Current48.0 A
Power Supply Input24-70 VDC
Rated Power400 W
Dimensions (L*W*H)141 x 75.5 x 25.4 mm
Operation Temperature0℃ ~ 55℃ (derate if over 55°C)
Storage Temperature-40℃ ~ 80℃
Humidity0 ~ 90% RH (non-condensing)
Elevation≤ 1000 m
Vibration/Strike5.88 m/s² / 19.6 m/s²
IP Grade / ContaminationIP20 / Contamination Rating 2
Control MethodMOSFET SVPWM Space Vector Pulse Width Modulation
IO Signal Input3 pcs (General)
IO Signal Output1 General DO Output, 1 Brake Output
Network (RS485)Modbus Communication
Network (RS-232)PC Debugging Interface

3.2 Servo Motor (DSY60-400L2B2M17S)

Parameter Value
Part NumberDSY60-400L2B2M17S
Rated Power400 W
Rated Voltage48 VDC
Rated Torque1.27 Nm
Peak Torque3.81 Nm
Rated Current10.2 A
Rated Speed3000 rpm
Torque Constant0.124 N.m/A
Line-line Resistance0.33 ohms ± 10%
Line-line Inductance0.65 mH ± 20%
Inertia0.51 kg·m²·10⁻⁴
Encoder17-bit single-turn magnetic incremental encoder
Poles10
IP RatingIP65
Shaft Diameter14 mm
Brake Holding Torque1.52 Nm
Brake Voltage24 VDC
Brake Power7.3 W
Brake Current0.32 A
Cable Length3 m (optional lengths: 1.5m and 5m)

4. Setup and Installation

4.1 Servo Drive Dimensions

The DSY-400RS servo drive has dimensions of 141mm (Length) x 75.5mm (Width) x 25.4mm (Height).

Servo driver front view with pinout diagram and dimensions.

Figure 4.1: DSY-400RS Servo Drive Front View and Dimensions.

4.2 Servo Drive Installation

Install the servo drive vertically to ensure proper airflow for cooling. Maintain minimum clearances around the drive for effective heat dissipation:

  • Minimum 20mm clearance above the air outlet.
  • Minimum 10mm clearance between adjacent drives.
  • Minimum 50mm clearance below the air intake.
Servo motor with attached cables.

Figure 4.2: Servo Motor with Cables.

4.3 System Structure and Main Circuit Connection

The servo system requires connections for DC power, motor power, encoder feedback, communication, and control signals. Ensure all connections are secure and correctly polarized.

Main Circuit Terminal Functions:

  • DC+, DC-: Input control circuit power (24-70VDC).
  • RB+, RB-: External Brake Resistor Connection Port.
  • U, V, W: Connects to the U, V, W phases of the motor.
  • PE: Ground Terminal. Connect to power grounding and motor grounding.

For a detailed system structure diagram and terminal definitions, refer to the official user manual (PDF) section 3.1 and 3.2.

4.4 Cable Connections

Ensure all cables are connected according to the pin definitions and wiring diagrams provided in the full manual.

  • Motor Power Cable: Connects the servo drive to the motor's U, V, W phases and PE ground. Pin definitions: U (Red), V (Yellow), W (Blue), PE (Yellow green).
  • Encoder Cable: Connects the servo drive to the motor's 17-bit incremental encoder. Pin definitions include +5V (Blue), 0V (Orange), SD+ (Brown), SD- (Green), PE (Shell), BAT+ (3), BAT- (4).
  • Brake Cable: Connects the motor brake to a 24V power supply via the servo drive's DO terminals. Ensure a freewheeling diode (e.g., UF1010G) is used for relay connections.
  • RS485 Communication Cable: Used for Modbus communication. Pin definitions: RS485_GND (PE), RS485+ (Signalling+), RS485- (Signalling-). Use shielded twisted-pair cables for long distances (up to 300m).
  • RS232 Debugging Cable: Connects to PC for debugging. Pin definitions: RS232-TXD, GND, RS232-RXD, PE.
Various cables included with the servo motor kit: motor cable, brake cable, encoder cable, and debugging cable.

Figure 4.3: Included Cables.

4.5 Pre-Operation Checks

Before powering on the system, perform the following checks:

  • Wiring: Verify all control circuit power input terminals (DC+, DC-), output terminals (U, V, W), and signal cables are correctly connected and insulated.
  • Grounding: Ensure servo drives and motors are reliably grounded.
  • Cable Stress: Confirm all cables are within their specified stress range.
  • Environment: Check for any wire stubs, metal filings, or foreign objects that could cause short circuits. Ensure drives and braking resistors are not near combustible materials.
  • Mechanical: Confirm the servo motor, shaft connection, and machine are reliably installed and in operable condition.

5. Operation

5.1 Basic Control Flow

The general process for setting up and operating the servo system involves:

  1. Start: Begin the process.
  2. Check Before Running: Verify wiring, conditions, and machine status.
  3. Power On: Turn on control and main circuit power. Ensure servo enable is invalid.
  4. JOG Operation: Use PC JOG mode to confirm normal motor rotation without abnormal vibration or sound.
  5. Parameter Set: Set common and mode-specific parameters.
  6. Servo Run: Perform initial low-speed rotation, set relevant parameters for desired goal, and debug the driver.
  7. Servo Stop: Servo enable off, fault shutdown, overtravel stop, or emergency stop.

5.2 JOG Operation

JOG mode allows for manual testing of motor rotation. Use the host computer software to input JOG velocity (0-9000 rpm). Enable JOG, then use forward/reverse commands. The driver will be disabled and motor power off upon JOG release.

5.3 Brake Control

The motor's built-in brake prevents shaft movement when the servo drive is not running, keeping the motor locked in position. It is not intended for active braking during operation.

Brake Wiring: The brake input signal has no polarity. Connect to a 24V power supply. If using a relay, ensure a freewheeling diode (e.g., UF1010G) is connected in the correct direction to prevent damage to the DO port.

Brake Software Setting: For motors with a brake, configure the second DO terminal as function 11 (FunOUT.11: BK, brake output) and define its effective logic. The brake is disconnected (released) when power is on and connected (engaged) when power is off.

Braking Resistor: During deceleration, the motor can generate energy back to the drive. An external braking resistor connected to RB+ and RB- terminals is required to consume this energy and prevent overvoltage. For the DSY-400RS, a 10 Ohm, 100W brake resistor is recommended.

5.4 Control Modes

The servo system supports Position Control, Speed Control, Torque Control, and Mixed-mode Switching. Each mode has specific parameters and operational procedures detailed in the full user manual.

  • Position Control Mode: Controls motor position based on pulse commands. Key settings include electronic gear ratio (P04-07, P04-09), position deviation clear (P04-22), and positioning completion (P04-23).
  • Speed Control Mode: Controls motor speed. Parameters include speed command source, acceleration/deceleration times, and speed limits.
  • Torque Control Mode: Controls motor torque. Parameters include torque command source, torque limits, and torque arrival settings.
  • Mixed Mode Switching: Allows dynamic switching between control modes (e.g., Torque to Speed, Speed to Position) using parameter P00.00 and DI function FunIN.10 (MODE_SWITCH).

5.5 Homing Function

The homing function establishes a zero position for the motor. Various homing modes are available, typically involving limit switches and the motor's Z signal. The process involves searching for a home switch, decelerating, reversing, and then searching for the Z signal to define the home position.

Homing modes are configured via parameter P16-08 and P16-09. Examples include homing by reverse limit switch, positive limit switch, or home switch, with or without zero position pulse signals. The system outputs a 'HomeAttain' signal (FunOUT.19) upon successful homing.

5.6 Operation Performance Adjustment

To optimize performance, gain adjustment is crucial. This involves tuning position loop gain (P07.00), speed loop gain (P07.01), speed loop integral time (P07.02), and command filters (P04.03, P04.04, P07.04).

Inertia Identification: The drive can identify the load inertia ratio (P00.05) using function P11.03. This helps in setting appropriate gain values. Conditions for accurate identification include motor speed up to 200rpm and acceleration above 3000rpm/s.

Mechanical Resonance Suppression: If vibration occurs, use torque command filters (P07.04, P07.09) or notch filters (P08.02-P08.07) to suppress resonance at specific frequencies. This allows for higher gain settings and improved performance.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your servo system.

  • Environmental Control: Ensure the operating environment remains within specified temperature and humidity ranges. Avoid dusty or corrosive atmospheres.
  • Cleaning: Periodically clean the servo drive and motor to prevent dust accumulation, which can hinder heat dissipation and lead to overheating. Use a soft, dry cloth.
  • Cable Inspection: Regularly inspect all cables for signs of wear, damage, or loose connections. Replace damaged cables immediately.
  • Grounding Check: Verify that all grounding connections remain secure and effective.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for the servo drive to ensure you have the latest features and bug fixes.

7. Troubleshooting

The servo drive provides alarm and warning indicators to help diagnose issues. Alarms are critical faults requiring immediate attention, while warnings indicate potential problems that should be addressed.

7.1 Alarm Levels

  • Level 1 (Fault): Indicates a serious alarm where the servo drive cannot operate normally. Requires shutdown and inspection. The DO terminal outputs an ALM signal.
  • Level 2 (Warning): Indicates a warning that does not immediately damage the device but requires attention to prevent escalation to a fault. The DO terminal outputs a WARN signal.

7.2 Fault Diagnosis and Treatment

Faults are categorized as Non-resettable NO.1, Resettable NO.1, and Resettable NO.2.

  • Non-resettable Faults: Require re-powering the drive after the fault is resolved. Examples include system parameter exceptions, motor model selection failure, overcurrent, encoder errors, and motor data verification failure.
  • Resettable Faults: Can be cleared by setting P11-01=1 or using DI function 2 (ALM-RST) after troubleshooting. Examples include overvoltage, undervoltage, overspeed, abnormal motor rotation during bootstrap charging, DI/DO terminal parameter setting faults, and reference position failure.
  • Resettable NO.2 Faults: Similar to Resettable NO.1 but may have different stop modes. Examples include position deviation too large, drive overload, motor overload, and motor stall.

7.3 Common Warnings and Treatments

Warnings indicate conditions that may lead to faults if not addressed:

  • Drive/Motor Overload Warning: Indicates the drive or motor is operating near its overload limit. Reduce load or check for mechanical issues.
  • Changed Parameters: If parameters are changed, re-power the drive for changes to take effect.
  • Overtravel Warning: Motor position exceeds soft limits. Check motion range and limit settings.
  • External Regenerative Resistor Warning: Resistor power may be too small or value incorrect. Verify resistor specifications.
  • Homing Timeout: Homing process failed to complete within the set time. Check home switch, speed settings, and mechanical path.

For a complete list of fault codes, warning names, and causes, refer to Chapter 6 of the full user manual (PDF).

8. User Tips

  • Initial JOG Test: Always perform a JOG test after initial setup to confirm motor rotation and check for abnormal vibrations or sounds before proceeding with complex operations.
  • Grounding is Key: Ensure proper grounding of both the servo drive and motor. This is critical for preventing electrical noise, ensuring stable operation, and protecting against faults.
  • Incremental Gain Adjustment: When adjusting gain parameters (e.g., position loop gain, speed loop gain), make small incremental changes and observe the motor's response. Aggressive changes can lead to instability.
  • Wiring Verification: Double-check all wiring connections against the provided diagrams, especially for brake and encoder connections. Incorrect wiring is a common source of operational issues.
  • EMC Precautions: For RS485 communication, use shielded twisted-pair cables and maintain adequate separation from strong current cables and metal backplanes to minimize electromagnetic interference.

9. Warranty and Support

For technical support, warranty information, or any inquiries regarding your STEPPERONLINE product, please contact us using the details below:

Please refer to the official user manual (PDF) for the most up-to-date and detailed information on all aspects of the product.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.