1. Product Overview
The JIKONG Smart BMS (Battery Management System) is an intelligent protection board designed for large-capacity series lithium battery packs. It offers comprehensive management and protection features to ensure the safety and longevity of your battery system.
Key functionalities include voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection. It also features a coulomb meter, Bluetooth communication, and optional GPS remote capabilities. This BMS is compatible with various battery chemistries, including Lithium Iron Phosphate (LiFePO4), Ternary Lithium, and Lithium Titanate (LTO) types.
Utilizing energy transfer active balancing technology with independent intellectual property rights, the BMS achieves a continuous balance current of 1A to 2A. This high-current active equalization significantly improves battery consistency, extends battery range, and mitigates battery aging.
A mobile application (APP) is available for both Android and iOS operating systems. The APP connects to the BMS via Bluetooth, allowing users to monitor real-time battery status, modify operating parameters, and control charge/discharge switches. Its compact size, ease of operation, and full feature set make it suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

2. Specifications
2.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 7.5-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 8 | Strings |
| Maximum Balancing Current | 1-2 | A |
| Maximum Charging Current | 100-300 | A |
| Maximum Discharge Current | 100-300 | A |
| Maximum Instantaneous Current | 400 | A |
| Maximum Internal Loop Resistance | 0.35 | mΩ |
| Protective Plate Size | 152.25*127.26*15.6 | mm |
| Finished Weight | 424 | g |
2.2. Key Features
- Balance Function: Active Balanced BMS (1A~2A balance current)
- Hardware or Smart: SMART BMS
- Charge and Discharge Port: Common Port BMS
- Protection Functions: Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection, Over Temperature Protection, Low Temperature Protection
- Battery Type Compatibility: Li-ion/LiFePo4/LTO
- Communication & Interfaces: BT (Bluetooth), Heat (Heating function), RS485, CAN, Parallel, Buzzer, GPS, LCD Display/Switch
- Certification: CE, FCC, RoHS


3. Setup and Installation
3.1. Package Contents
Before installation, please verify that all components are present:
- JIKONG Smart BMS Unit
- Operating Manual (PDF version available via QR code)
- Screws (x4)
- NTC (Negative Temperature Coefficient) Sensor (40cm)
- Heating Cable (16cm) (if applicable to model)
- CAN Cable (25cm) (if applicable to model)
- Switch (50cm)
- Wires (70cm) for B1A8S20P-HC / B2A8S20P-HC
- Pack box

3.2. Wiring Diagram
The JK-BxA8S-20P series protection board is designed for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure correct connections to prevent damage.


3.3. Interface Definitions
Familiarize yourself with the various interfaces on the BMS board:



3.4. Device Activation
Before powering on the protection board, ensure all balance cables are properly connected and the P- and B- terminals are correctly wired. Confirm the protection board is securely fixed to the battery pack. Incorrect connections can lead to malfunctions or damage.
The BMS does not have a physical power switch. It activates in charging activation mode: the charger voltage must be 2V higher than the battery voltage. After assembling the battery, connect the charger to power on the protection board.
Alternatively, the BMS can be activated using a display activation button or an additional switch. If you have a display screen and button, simply insert the cable into the display interface and press the button to activate.
4. Operating Instructions
4.1. APP Installation and Connection
- Download APP:
- iOS: Search for "JIKONG BMS" in the Apple App Store.
- Android: Search for "JK BMS" in the Google Play Store. (Android Version 7 minimum is required).
You can also scan the QR code below to download the mobile APP:

Figure 10: Mobile APP Link QR Code. - Enable Bluetooth & GPS: Turn on Bluetooth and GPS on your mobile phone.
- Connect to BMS: Open the JIKONG BMS APP. Click on the top left corner to search for devices. Select your device name and enter the default password:
1234.

4.2. Initial Parameter Settings
For the first startup, parameters need to be set. The default parameter setting password is 123456. You primarily need to set the number of units (cells) and the battery type (Li-ion/LiFePo4/LTO).
After setting the parameters, return to the real-time status page to check the battery status. If no error message is prompted, the operation is normal. In the APP, blue indicates the highest voltage, and red indicates the lowest voltage.
4.3. Active Equalization
The BMS uses active equalization to transfer energy from high-voltage cells to low-voltage cells. You can set the balance trigger pressure difference (in mV) in the APP's parameter settings. When balancing is enabled, it automatically activates if the voltage difference between any two battery strings exceeds the set value, and deactivates when the difference falls below the set value. The default balance current is 1A/2A. You can adjust this current based on your battery capacity, but it's recommended not to exceed 0.2C of the battery capacity. If active balancing is not required, you can turn off the balance switch in the BMS control page of the APP.
4.4. Heating Function (Optional)
The optional heating function warms the battery in low-temperature conditions using a resistance heater or heating film, preventing charging/discharging issues due to reduced battery activity. The designed heating current is 20A. You can activate/deactivate this function via the BMS control page in the APP based on ambient temperature.
It is recommended to install a normally closed temperature control switch (45°C to 65°C) in series with the heating circuit as a secondary protection against thermal runaway. The heating interface requires an external heating film or charger. The green cable connects to the heating film, and the red and black cables connect to the charger. Maximum heating power is 3A, and maximum heating voltage is 100V.
Heating activates under these conditions:
- Battery temperature is lower than the low-temperature protection temperature for charging.
- When connecting the heating film, the APP will activate heating, consuming battery power.
- Heating via the charger depends on the protection board hardware and charger. Confirm technical status before ordering.
4.5. Smart Energy Working Modes
The BMS supports different working modes to optimize energy consumption and battery life:

- Storage Mode: For transportation, offline, or wireless transmission. The BMS is in storage mode and does not consume battery pack current.
- Normal Working Mode: When the charger is inserted in storage mode and off mode, the BMS immediately returns to normal working mode, and all protection, equalization, and communication functions resume.
- Standby Mode: When the battery pack is in a static state (no charge/discharge current and no equilibrium current), the BMS automatically enters standby mode after a set time (e.g., 30 days).
- Shutdown: To prevent the BMS from wasting power during long periods of disuse and damaging the battery pack, the BMS automatically shuts down when a cell falls below the shutdown voltage.
4.6. Protection and Recovery Functions
The BMS includes various protection mechanisms to safeguard your battery:
- Charge Overvoltage Protection & Recovery: Standard feature. Users can set single overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set voltage during charging, the BMS stops charging. Charging resumes when all cells are below the recovery voltage.
- Discharge Undervoltage Protection & Recovery: Standard feature. Users can set undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell falls below the set undervoltage during discharge, the BMS stops discharging. Discharge resumes when all cells are above the recovery voltage. If any cell falls below the automatic shutdown voltage, the BMS shuts down.
- Charge Overcurrent Protection & Recovery: Standard feature. Users can set continuous charging current, overcurrent delay, and recovery time in the APP. If charging current exceeds the set value for the delay period, charging stops. Charging resumes after the recovery time.
- Discharge Overcurrent Protection & Recovery: Standard feature. Users can set continuous discharge current, overcurrent delay, and recovery time in the APP. If discharge current exceeds the set value for the delay period, discharging stops. Discharging resumes after the recovery time. (Note: Max continuous discharge current cannot exceed 200A).
- Over Temperature Protection & Recovery: Standard feature for both charging and discharging. Users can set protection and recovery temperatures in the APP. If battery temperature exceeds the set value, the BMS stops the respective operation (charging/discharging). Operation resumes when temperature falls below the recovery value.
- Low Temperature Protection & Recovery: Standard feature for charging. Users can set protection and recovery temperatures in the APP. If battery temperature falls below the set value during charging, the BMS stops charging. Charging resumes when temperature rises above the recovery value.
- Short Circuit Protection & Recovery: Standard feature. Users can set short circuit protection delay and recovery time in the APP. If a short circuit is detected, the BMS stops the operation. It resumes after the recovery time. If charging or discharging short circuit protection is triggered upon initial connection, increasing the delay time may resolve the issue, as it could be due to peak currents from the charger or large load capacitance.
- Emergency Switch: Standard feature. If issues like over-temperature, over-discharge, over-charge, or cell drop occur during normal use, activating the emergency switch in the APP's BMS control page will enable charge and discharge for 30 minutes, providing emergency operational time. The protection board will continue to operate until the 30-minute cycle ends, even if a single cell reaches the automatic shutdown voltage.
- Intelligent Sleep: Standard feature. Users can enable/disable this in the APP. Its purpose is to reduce BMS energy consumption when in standby (charge/discharge current less than 1A for 26 consecutive hours). The BMS can be reactivated by pressing a button or connecting a charger.
- Communication Function (Optional): Supports optional CAN and RS485 functions. Users can select CAN or RS485 for multiplexed ports in the APP. Address and communication protocol can be configured as needed. Refer to the Jikong Protection Board communication protocol document for details.
5. Maintenance
To ensure optimal performance and longevity of your JIKONG Smart BMS, regular checks and proper handling are recommended:
- Regular Monitoring: Periodically check the battery status and parameters via the mobile APP to ensure everything is operating within normal ranges.
- Connection Integrity: Ensure all wiring, especially balance cables and main power connections (P- and B-), are secure and free from corrosion or damage. Loose connections can lead to inaccurate readings or system malfunctions.
- Environmental Conditions: Operate the BMS within its specified temperature range (-30°C to 70°C). If operating in extremely cold environments, utilize the heating function to protect the battery cells.
- Firmware Updates: Check the JIKONG official website or APP for any available firmware updates to ensure your BMS has the latest features and bug fixes.
- Cleaning: Keep the BMS unit clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
- Storage: If the battery pack with the BMS is to be stored for an extended period, ensure it is in a safe, dry place and consider activating the intelligent sleep function to minimize power consumption.
6. Troubleshooting (FAQ)
6.1. BMS Does Not Turn On
- Balance Cable Connection: Ensure the last "B+" line of the balance cable is correctly connected to the positive pole of the battery pack.
- Charger Voltage: After connecting the charger, ensure its voltage output is at least 4V higher than the total battery pack voltage to activate the BMS.
- Charger Output: Verify that the charger itself has a voltage output.
6.2. Inaccurate Voltage Readings
- Calibration: Measure the actual total voltage of the battery pack using a multimeter. Then, enter this value into the "voltage calibration" section on the APP's parameter setting page.
6.3. Inaccurate Current Readings
- Main Connections: Ensure both the B- and P- terminals of the protection board are connected using two 7AWG wires in parallel. Incorrect connection can lead to current errors.
- Calibration: Measure the actual current of the battery pack using a clamp meter. Enter this value into the "current calibration" section on the APP's parameter setting page. A larger actual current generally leads to higher calibration accuracy.
6.4. Inaccurate Capacity Estimation
- Initial Estimate: The initial capacity estimated when the protection board is first powered on, based on monomer voltage, may be inaccurate.
- Calibration Cycle: To calibrate the capacity, fully discharge the battery pack with the protection board to its cut-off voltage, then fully charge it without interruption.
6.5. Designed String Number Inconsistent with Actual String Number
- APP Setting: Check if the "unit quantity" in the APP's parameter settings is correctly configured to match your battery pack's string count.
- Acquisition Cable: If there is no voltage reading in two or more strings in the middle of the pack, check if the acquisition cable has become disconnected or is faulty.
7. User Tips
- Initial Setup: Always double-check all wiring connections before powering on the BMS for the first time to prevent potential damage.
- APP Monitoring: Regularly use the mobile APP to monitor your battery's health and performance. This can help in early detection of any anomalies.
- Parameter Customization: Take advantage of the APP's ability to customize protection parameters (e.g., voltage thresholds, current limits, temperature settings) to perfectly match your specific battery type and application requirements.
- Heating Function: If your model supports heating and you operate in cold climates, ensure the heating function is properly configured and utilized to maintain battery efficiency and prevent damage.
- Safety First: Pay attention to any alarm notifications from the BMS, as these indicate potential safety risks such as over-temperature or over-current. Address them promptly.
8. Warranty and Support
For detailed warranty information and technical support, please refer to the official documentation provided by Chengdu Jikong Technology Co.LTD.
A comprehensive user manual in PDF format is available for download: JIKONG Smart BMS User Manual (PDF). This document contains additional in-depth information regarding product specifications, interface definitions, and parameter settings.