This series of products is a single-output DC voltage regulator power supply with an LED digital display. It can simultaneously display voltage, current, power, and output time. Both voltage and current are continuously adjustable.
The MYAMi MY-K3020PE is a laboratory programmable DC power supply designed for various applications requiring precise and stable power output.
1.1. Functional Features
- LED Digital Display: Simple and intuitive display of power transmission, showing output voltage (V-out), preset voltage (V-set), output current (I-out), preset current (I-set), and elapsed time.
- Output Control: Features steady pressure (Constant Voltage - CV) and steady flow (Constant Current - CC) automatic switching, with a one-key output ON/OFF function for flexible control.
- Multiple Protection: Incorporates five heavy-duty protection functions: Overvoltage Protection (OVP), Overcurrent Protection (OCP), Overpower Protection (OPP), Overtemperature Protection (OTP), and Short-Circuit Protection.
- Memory Functions: Six sets of shortcut parameter callbacks and storage functions, supporting hardware List programmable sequence output.
- Communication Interfaces: Standard RS-485 serial port, supporting Modbus programming, and USB interface for PC connection.
- SENSE Compensation: Standard SENSE compensation interface for improved accuracy.
- Output Timing: Selected output timing ON/OFF and output meter function.
- Temperature Control: Intelligent temperature-controlled cooling fan for energy saving and extended lifespan.
- Keyboard Lock: One-key function to lock the keyboard to prevent misoperation.
2. Safety Profile
This section contains important safety instructions that must be followed for operating and storing the power supply. To ensure your personal safety and optimal performance, please read the following instructions carefully before operation.
2.1. General Safety Guidelines
- Do not place heavy objects on the casing.
- Avoid serious impact or improper disposal.
- Take measures to prevent electrostatic discharge.
- Do not block or isolate the fan vents.
- Do not open the machine unless you are a qualified professional.
2.2. Electrical Safety
- AC Input Voltage: 220V ± 10%, 50Hz (or 110V input / 220V manual switch). Ensure the correct voltage is selected for your region.
- Grounding: The ground wire of the power cord must be connected to a proper ground to prevent electric shock.
- Fuse: Ensure the correct fuse model is installed before booting. To prevent fire, replace the fuse with one complying with the specified model and rating. Always cut off the power supply before replacing the fuse.
2.3. Cleaning and Environment
- Cleaning: Cut off the power supply before cleaning. Use a mild detergent and a water-wet soft cloth. Do not directly spray detergent. Do not use chemical or cleaning agents containing grinding examples such as benzene, toluene, xylene, and acetone.
- Operating Environment: Indoor use only. Avoid direct sun exposure and dusty conditions. Keep away from strong magnetic fields. Relative humidity: <80%. Altitude: <2,000 m. Ambient temperature: 5°C to 40°C.
- Storage Environment: Indoor storage. Relative humidity: <70%. Ambient temperature: 0°C to 70°C.
3. Product Components and Layout
3.1. Front Panel Diagram
- Preset Voltage (V-set): Displays the set voltage value.
- Output Voltage (V-out): Displays the actual output voltage.
- Preset Current (I-set): Displays the set current value.
- Output Current (I-out): Displays the actual output current.
- Time/Power/Status/Menu: Displays elapsed time, output power, or menu status.
- Output Switch: Toggles the power output ON/OFF.
- Direction Key: Used for navigation and adjustment in menu settings.
- Enter Button: Confirms selections and settings.
- Voltage Adjustment Knob: Adjusts voltage (Push for fine/coarse adjustment).
- Current Adjustment Knob: Adjusts current (Push for fine/coarse adjustment).
- Menu Button: Accesses the function menu.
- OVP (Overvoltage Protection): Sets and tests overvoltage protection.
- OCP (Overcurrent Protection): Sets and tests overcurrent protection.
- CV (Constant Voltage): Indicates constant voltage mode.
- CC (Constant Current): Indicates constant current mode.
- M1-M6 Buttons: Shortcut keys for storing and recalling parameters.
- B Lock Button: Locks the keyboard to prevent accidental changes.
- List Button: Activates List mode for programmable sequences.
- Negative Output Terminal (GND): Ground connection.
- Positive Output Terminal (+): Positive output connection.
3.2. Rear Panel Diagram
- SENSE Compensation Interfaces (SENSE + / SENSE -): Used for remote voltage sensing to compensate for voltage drop across load leads.
- Output Terminals (OUTPUT + / OUTPUT -): Main power output terminals.
- Heat Dissipation Fan Vent: For power air cooling. The fan starts based on internal operating temperature.
- USB Serial Port Seat: For connecting to a PC via USB.
- Interface (RS485): Standard RS-485 communication interface.
- Power Input Socket & Fuse Seat: AC input port and fuse holder. For models above 2400W, this may be a direct cable connection.
- Input Power Switch: Toggles the main power ON/OFF.
4. Setup and First Use
4.1. Connecting the Power Supply
- Input Power Requirements: Refer to the 'Specifications' section for detailed input power requirements.
- Check the Fuse: The instrument comes with a factory-installed fuse. Verify it is correctly seated.
- Connect the Instrument Power Cord: Connect the power supply to an appropriate AC power source using the provided power cord. For models above 2400W, a direct cable connection from the power supply to the AC source may be required.
To avoid electric shock, verify that the instrument is correctly grounded before use.
4.2. Power-on Inspection
- Press the power switch button on the front panel to turn on the power. The backlight of the ON/OFF button will initially be red.
- After a brief moment, the backlight will turn green, indicating the power is on and ready for output.
- Important: If the machine is turned on again after shutdown, ensure the time interval between the two startups is more than 5 seconds.
4.3. Output Check (Empty Load)
This check ensures the instrument responds correctly to front panel operations and outputs the rated values.
- Ensure no load is connected to the output terminals.
- Turn on the power. Confirm that the current setting value (I-set) is not 0.
- Press the "ON / OFF" key to enable the output. The backlight will turn green, and the channel will be in the stabilized output state (CV light ON).
- Check if the voltage can be adjusted from 0 to the maximum rated value using the voltage adjustment knob.
5. Operating Instructions
5.1. Output Switch
- To turn on the power output, press the ON/OFF key. The backlight will turn green.
- To turn off the power output, press the ON/OFF key again. The backlight will turn red.
5.2. Steady Output (CV and CC Modes)
The power supply provides two output modes: Constant Voltage (CV) and Constant Current (CC).
- In CV mode: The output voltage is directly controlled by the voltage adjustment knob.
- In CC mode: The output current is controlled by the current adjustment knob.
Example: Setting 16V, 2A Output
Assume the voltage is set to 16V, and the current is set to the maximum rating. If the access load is 8 Ω / 300W, then 16V / 8 Ω = 2A, which is less than the maximum rating. Therefore, the power supply will output 16V, 2A.
- Turn on the Power Supply: Press the power supply key to start the instrument.
- Voltage Setting: Adjust the voltage adjustment knob to set the voltage value to 16V.
- Current Setting: Adjust the current adjustment knob to stabilize the current value to the maximum rated value (or desired limit).
- Connect the Output Lead: Connect the instrument output terminals to the load as shown in the diagram below.
- Open the Output: Press the "ON / OFF" key. The backlight will turn green, and the instrument will operate in stable voltage control output mode.
Tip: In CV mode, if the output current exceeds the set current limit due to load changes, the instrument will automatically switch to CC mode. The output voltage will then decrease proportionally to maintain the set current.
5.3. Steady Current Output
For example, if the voltage is set to 16V, and the current is set to 5A. If the access load is 1 Ω / 300W, then 16V / 1 Ω = 16A, which is greater than the set 5A. The power supply will operate in CC mode, outputting 5V, 5A.
- Connect the Output Lead: Connect the instrument output terminals to the load.
- Turn on the Power Supply: Press the power supply key.
- Voltage Setting: Adjust the voltage adjustment knob to set the voltage value to 16V.
- Current Setting: Adjust the current adjustment knob to stabilize the current value to 5A.
- Open the Output: Press the "ON / OFF" key. The backlight will turn green, and the instrument will operate in steady flow output mode.
Tip: In CC mode, if the output voltage exceeds the set voltage limit due to load changes, the instrument will automatically switch to CV mode. The output current will then decrease proportionally to maintain the set voltage.
Warning: Incorrect connections may cause damage to this product or to the connected equipment.
5.4. List Setting
The List function allows for programmable sequences of voltage, current, and time settings.
- Step 1: Select the list key (M1-M6) to be set.
- Step 2: Press the voltage button or the left and right buttons to select the desired setting.
- Step 3: Rotate the voltage button or the up and down buttons to select the number to be set.
- Step 4: Press the Enter button for current setting.
Long press the "List" mode key for 2 seconds to enter or exit hardware List mode. In List function mode, press M1-M6 to select or delete the cycle output of the selected parameter group. Press the ON/OFF key to start the List function output.
5.5. Voltage/Current Adjustment Digit Method
Press 'U CV' or 'I CC' first, then press or rotate the corresponding knob to adjust the voltage and current digits (or adjust with the up, down, left, and right keys).
5.6. Menu Navigation and Settings
- MENU Key: Short press to enter or switch the function menu. The corresponding function menus are:
- Output Timing (Time): Adjust the current value size or select ON/OFF.
- Output (OUT): Select ON/OFF.
- Compensation (SENS): Select ON/OFF.
- Sound (BELL): Select ON/OFF.
- Serial Communication Address (Addr): Adjust the current value size or select ON/OFF.
- Enter Key: Saves the value or status when switching between editing function menu status and parameter values.
- Direction Keys: In editing mode, short press left/right to move the cursor, and up/down to increase or decrease the value by 1.
6. Maintenance
6.1. Regular Inspection
To ensure the product operates in its best working condition, regular checks are recommended:
- Check for any signs of burnout or damage.
- Inspect the power output terminals for loosening.
- Verify the power input outlet is correctly used and connected.
6.2. Fuse Replacement
Note: For models below 2400W, the fuse is replaceable. Models 2400W and above typically have a built-in circuit breaker instead of a fuse seat.
- Disconnect Power: Always cut off the power supply and unplug the power cord before attempting to replace the fuse.
- Remove Fuse Box: Use a small screwdriver to gently pry open and remove the fuse box.
- Replace Fuse: Insert a new fuse with the correct specifications.
- Reassemble: Close the fuse box and reconnect the power cord.
Fuse Specifications:
- For 1200W models:
- 220V: F 10A / 250V
- 110V: F 20A / 250V
- For 1200W < Power < 2400W models:
- 220V: F 20A / 250V
7. Troubleshooting
This section provides guidance on common issues and their potential solutions.
- No Output / Output Disconnection:
- Check if the output function is turned ON (green backlight on ON/OFF button).
- Verify that Overvoltage Protection (OVP) or Overcurrent Protection (OCP) has not been triggered. If triggered, the output will automatically disconnect. Adjust OVP/OCP settings if necessary.
- Ensure all connections are secure and correct.
- Output Mode Switching (CV/CC):
- The power supply automatically switches between Constant Voltage (CV) and Constant Current (CC) modes based on the load and set limits. This is normal operation.
- If in CV mode, and the output current exceeds the set limit, it will switch to CC mode. Increase the current setting value to restore CV output.
- If in CC mode, and the output voltage exceeds the set limit, it will switch to CV mode. Increase the voltage setting value to restore CC output.
- Keyboard Unresponsive:
- Check if the 'B Lock' function is active. If the 'B Lock' light is on, long press the 'B Lock' key for 2 seconds to unlock the keyboard.
- Overheating:
- Ensure the heat dissipation fan vents are not blocked.
- The intelligent temperature-controlled fan will activate automatically if the internal temperature reaches 50°C. Allow adequate ventilation around the unit.
8. Specifications
8.1. General Specifications
| Attribute | Value |
|---|---|
| Product Name | Laboratory Programmable DC Power Supply |
| Model Number | MY-K3020PE |
| Brand Name | MYAMi |
| Type | Power Supply |
| Output Type | SINGLE |
| Output Power | >500W |
| Output Current | 0-20A |
| Output Voltage | 0-30V |
| Rated Capacity | >1000VA |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
| Certification | CE |
| Origin | Mainland China |
| is_customized | Yes |
8.2. Performance Indicators
| Parameter | Resolution |
|---|---|
| Voltage Resolution (<100V) | 10mV |
| Voltage Resolution (≥100V) | 100mV |
| Current Resolution (<100A) | 10mA |
| Current Resolution (≥100A) | 100mA |
| Power Resolution (<10W) | 1mW |
| Power Resolution (≥10W) | 10mW |
| Power Resolution (≥100W) | 0.1W |
| Power Resolution (≥1000W) | 1W |
| Time Resolution | Seconds (S) |
8.3. Output Parameters
- Voltage Stability: 2% (after startup over 10s)
- Current Stability: 0.5%
- Load Stability: 0.5%
- Ripple Noise: 1% (valid value)
8.4. Preset Accuracy
- Output Voltage: ± 0.1V
- Output Steady Flow: ± 0.1A
8.5. Physical Dimensions and Weight
| Category | Value |
|---|---|
| Naked Machine Size (<2400W) | 330 (D) x 250 (W) x 155 (H) mm |
| Naked Machine Size (2400W) | 410 (D) x 250 (W) x 155 (H) mm |
| Packaging Dimensions (<2400W) | 420 (D) x 310 (W) x 220 (H) mm |
| Packaging Dimensions (2400W) | 497 (D) x 310 (W) x 220 (H) mm |
| Net Weight (<2400W) | About 5Kg |
| Net Weight (≥2400W) | About 7.5Kg |
| Package Length | 52 cm |
| Package Width | 34 cm |
| Package Height | 26 cm |
| Package Weight | 8.0 kg |
8.6. Communication Parameters
- Baud Rate: 9600
- Start Position: 1
- Data Bit: 8
- Check Position: No
- Stop Position: 1
9. User Tips
- Always ensure proper grounding to prevent electrical hazards.
- When connecting a load, double-check the polarity to avoid damage to the power supply or the device under test.
- Utilize the memory (M1-M6) functions for frequently used voltage/current settings to save time during repetitive tasks.
- For precise voltage output at the load, especially with long leads or high currents, consider using the SENSE compensation interface.
- Keep the fan vents clear to ensure efficient cooling and prolong the life of the power supply.
- Familiarize yourself with the OVP and OCP settings to protect your circuits from accidental overvoltage or overcurrent conditions.
10. Warranty and Support
Thank you for choosing this MYAMi power supply. We are committed to providing quality products and support.
10.1. Warranty Services
The product comes with a 12-month warranty period for free warranty service, excluding accessories. Please retain your invoice and warranty card for service. The company will not be responsible for any damage or loss during the delivery process for repairs.
Conditions Not Covered by Warranty:
- Damage caused by human factors.
- Beyond the validity period of the warranty.
- Altering the warranty certificate without authorization.
- Damage caused by failing to use, maintain, and keep the product according to the instructions.
- Product damage caused by natural disasters, power grid failure, or other irresistible factors.
- Attachments are not covered by the warranty.
- The product model or number on the warranty certificate does not comply with the physical goods.
10.2. Additional Resources
For further details and comprehensive instructions, you may refer to the official user manual PDF:
A product demonstration video is also available:
Video: MYAMi MY-K3020PE Programmable DC Power Supply Demonstration
11. Statement of Toxic and Harmful Substances
This table indicates the presence of toxic and harmful substances or elements in the product components, in accordance with SJ/T 11363-2006 standard.
| Component Name | Lead (Pb) | Mercury (Hg) | Cadmium (Cd) | Hexavalent Chromium (Cr(VI)) | Polybrominated Biphenyls (PBB) | Polybrominated Diphenyl Ethers (PBDE) |
|---|---|---|---|---|---|---|
| Printing Electricity | X | O | O | O | O | O |
| Road Components | X | O | O | O | O | O |
| Transformer | X | O | O | O | O | O |
| Connecting Line | X | O | O | O | O | O |
| Hardware Machine Chest | X | O | O | O | O | O |
| Power Line | X | O | O | O | O | O |
| Electron Material | O | O | O | O | O | O |
| Plastic Cement Face Plate | O | O | O | O | O | O |
| Pack Material | O | O | O | O | O | O |
O: Indicates that the content of this toxic and harmful substance in all homogeneous materials of this component is in compliance with SJ/T 11363-2006 standard.
X: Indicates that the content of the toxic and harmful substance in at least one homogeneous material of the component exceeds the limit requirements specified in the SJ/T 11363-2006 standard.
Note: This table shows that the product may contain these substances, but the information may be continuously updated with technological development. The reason for the label "X" is that there is no alternative technology and components available now, and it meets the requirements of the Electronic Information Product Pollution Control Management Measures of the People's Republic of China.