1. Introduction
The WinaPEX 268C is an ultra-high sensitivity clamp meter specifically designed for precise leakage current detection and comprehensive electrical measurements. With a minimum measurement current of AC 60μA and a high resolution of 0.01mA, it provides accurate monitoring in various complex electrical environments. This device is ideal for electricians and technicians working with grounding wires, single-phase, three-phase three-wire, and three-phase four-wire electrical systems, and for detecting leaks in motors, household appliances, and other electrical devices.

2. Setup
2.1 Package Contents
Before using your WinaPEX 268C Clamp Meter, please verify that all items listed below are present in the package:
- 1 x WinaPEX 268C Clamp Meter
- 1 x Pair of Test Leads (Red and Black)
- 1 x User Manual (this document)
- 1 x Thermocouple
- 1 x Type-C USB Cable
- 1 x Storage Bag

2.2 Product Overview and Components
Familiarize yourself with the different parts of your clamp meter:

- NCV Sensing Position: Used for Non-Contact Voltage detection.
- Jaw: The clamping mechanism for measuring current without breaking the circuit. Features a 22mm jaw opening for easier measurement.
- Trigger: Opens and closes the jaw.
- On/Off/Function Selection Button: Powers the device on/off and cycles through measurement functions.
- Data Retention/Backlight Adjustment Button (HOLD): Holds the current reading on the display; long press to adjust backlight brightness.
- LIVE Button: For live wire detection.
- ZERO Button: Used to clear capacitance readings or zero out other measurements.
- COM Port: Common input for test leads.
- VΩHz Port: Input for voltage, resistance, and frequency measurements.
- MAX 1000V DC 750V AC: Indicates maximum voltage ratings.
- Socket: Input for test leads.
- Flashlight: Provides illumination for working in dark environments.
- Current Switching Button: Switches between different current measurement modes.
- Battery Compartment: Houses the rechargeable lithium battery.
- Charge Up Port: Type-C port for charging the device.

2.3 Battery Charging
The WinaPEX 268C is equipped with a built-in 3.7V lithium battery with a capacity of 750mAh, providing approximately 20 hours of continuous operation on a full charge. To charge the device:
- Connect the provided Type-C USB cable to the charge up port on the side of the clamp meter.
- Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer's USB port.
- The battery indicator on the display will show charging status.
- Once fully charged, disconnect the cable.

3. Operating Instructions
3.1 Power On/Off and Function Selection
- Power On/Off: Press and hold the On/Off/Function Selection button to turn the device on or off.
- Function Selection: Briefly press the On/Off/Function Selection button to cycle through different measurement modes (e.g., AC Voltage, DC Voltage, Resistance, etc.).
3.2 Intelligent Recognition
The WinaPEX 268C features intelligent recognition, automatically detecting and displaying the type of measurement (DC Voltage, AC Voltage, Buzzer, Resistance) when test leads are connected, simplifying operation.

3.3 Measurement Functions
The clamp meter supports a wide range of measurements, indicated by icons on the functional display:

- AC/DC Voltage (V): Measure alternating and direct current voltage.
- AC Current (A): Measure alternating current using the clamp jaw.
- Resistance (Ω): Measure electrical resistance.
- Frequency (Hz): Measure the frequency of an AC signal.
- Temperature (°C/°F): Measure temperature using the thermocouple.
- Diode Test: Check diode functionality.
- Continuity (Beep): Test for circuit continuity.
- Live Line Detection (LIVE): Identify live wires.
- Leakage Detection: Specialized function for detecting leakage current.
- Screen Rotation: Rotate the display for better viewing angles.
- Clear Capacitance (ZERO): Zero out capacitance readings.


3.4 Leakage Current Detection
The WinaPEX 268C excels in leakage current detection with a range of AC 60μA to 100A and a resolution of 0.01mA. To perform leakage current measurements:
- Select the leakage detection mode using the function selection button.
- Open the clamp jaw using the trigger.
- Enclose the conductor (ground wire, single-phase, three-phase three-wire, or three-phase four-wire) within the jaw. Ensure only one conductor is inside the jaw for accurate leakage measurement.
- Read the leakage current value on the display.

3.5 Fire Wire / Null Line Detection
The device can distinguish between fire (live) and null (neutral) lines:

3.6 Additional Features
- Data Hold (HOLD): Press the HOLD button to freeze the current reading on the display. Press again to release.
- Zero Function (ZERO): Use this button to zero out capacitance measurements or other functions as needed.
- Screen Rotation: Long press the screen rotation button to rotate the display 180 degrees, allowing for easier reading in various orientations.
- Flashlight: Press the flashlight button to illuminate the work area, especially useful in dimly lit environments.
- Brightness Adjustment: The display offers 5 levels of brightness adjustment, suitable for various lighting conditions.
- Automatic Shutdown: The device features an automatic shutdown function to conserve battery life when not in use for a certain period.



4. Maintenance
- Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Battery Care: Recharge the lithium battery regularly, especially if the device will not be used for an extended period, to maintain battery health.
- Storage: Store the clamp meter in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
5. Troubleshooting
- No Display/Device Not Turning On: Ensure the battery is charged. Connect the Type-C cable and charge the device.
- Inaccurate Readings: Check that the test leads are properly connected and that the correct measurement mode is selected. For current measurements, ensure only one conductor is within the clamp jaw.
- Low Battery Indication: Recharge the device immediately when the low battery indicator appears to ensure continuous operation and prevent data loss.
- Leakage Current Detection: The device is specifically designed for leakage current detection with high precision. If readings are unexpected, ensure proper isolation of the circuit being tested.
6. Specifications
The WinaPEX 268C Clamp Meter offers the following technical specifications:
| Measurement Type | Range | Accuracy | Resolution |
|---|---|---|---|
| DC Voltage | 6V | ± (0.5%+3) | 1mV |
| 60V | 10mV | ||
| 1000V | ± (0.8%+10) | 100mV | |
| AC Voltage RMS | 6V | ± (0.8%+10) | 1mV |
| 60V | 10mV | ||
| 200V | 100mV | ||
| 750V | ± (1.2%+10) | 1V | |
| AC current | 60mA | ± (1.2%+8) | 0.01mA |
| 600mA | 0.1mA | ||
| 6A | ± (1.5%+10) | 1mA | |
| 100A | 10mA | ||
| Resistance (Ω) | 600Ω | ± (0.8%+3) | 0.1Ω |
| 6KΩ | 1Ω | ||
| 60KΩ | 10Ω | ||
| 600KΩ | ± (2.5%+15) | 100Ω | |
| 60MΩ | 10KΩ | ||
| Capacitance(C) | 6nF | ± (3.5%+20) | 1pF |
| 60nF | 10pF | ||
| 600nF | 100pF | ||
| 6uF | 1nF | ||
| 60uF | ± (5.0%+20) | 10nF | |
| 6mF | 1uF | ||
| Temperature measurement (°C/°F) | (-20-1000) °C | ± (1.0%+5) < 400°C; ± (1.5%+15) ≥400°C | 1°C |
| (0-1832) °F | ± (0.75%+5) < 750°F; ± (1.5%+15) ≥750°F | 1°F | |
| Diode and on/off test | Diode forward voltage drop: Forward DC current is about 1mA, Reverse voltage approximately 3V. The buzzer emits a long sound when the resistance value at two points is tested to be less than (50 ± 20) Ω. | Open circuit voltage approximately 3V | |

6.1 Physical Dimensions
- Dimensions: 165mm (Length) x 68mm (Width) x 26mm (Thickness)

7. User Tips
- Leakage Current Focus: Remember that this meter is highly sensitive for leakage current. For accurate readings, ensure the circuit is properly isolated and only the conductor being measured is within the clamp jaw.
- Screen Visibility: Utilize the screen rotation feature by long-pressing the corresponding button to adjust the display for optimal viewing angles, especially when working in awkward positions. The adjustable brightness also helps in various lighting conditions.
- Battery Life: The 20-hour continuous battery life is substantial, but always ensure the device is charged before critical tasks to avoid interruptions.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase.