1. Introduction
This manual provides essential information for the safe and efficient use of your XINJE PLC Programmable Logic Controller. The XINJE XC series PLCs are designed for industrial control applications, offering reliable performance and flexible programming capabilities. Please read this manual thoroughly before installation and operation.

Figure 1: Front view of a XINJE XC3-32R-E PLC, showing terminals and indicator lights.
2. Safety Instructions
Always observe the following safety precautions to prevent personal injury or damage to the equipment:
- Ensure power is disconnected before performing any wiring or maintenance.
- Only qualified personnel should install, operate, and maintain this device.
- Verify all wiring connections are correct and secure before applying power.
- Do not operate the PLC in environments exceeding its specified temperature, humidity, or vibration limits.
- Protect the device from dust, moisture, and corrosive gases.
3. Product Overview and Models
The XINJE XC series PLCs are compact and feature-rich programmable logic controllers. Key features include various input/output configurations and communication interfaces.
3.1 Available Models
The following models are part of the XINJE XC series:
- XC3-14R-E
- XC3-14T-E
- XC3-14RT-E
- XC2-14T-E
- XC2-16T-E
3.2 Physical Dimensions
Refer to the diagrams below for the physical dimensions of various XC3 series models. All dimensions are in millimeters (mm).

Figure 2: Dimensional drawing for XC3-42 model. Dimensions include overall length (139.0 mm), width (73.3 mm), and height (102.0 mm).

Figure 3: Dimensional drawing for XC3-14 (top) and XC3-24/32 (bottom) models. XC3-14 has a length of 63 mm, while XC3-24/32 has a length of 139 mm. Both have a height of 102 mm and a width of 73.3 mm.
4. Installation and Wiring
Proper installation and wiring are critical for the safe and correct operation of the PLC. Refer to the video demonstration and the following instructions.
Video 1: XINJE PLC Wiring Demonstration. This video illustrates the power supply, input, and output wiring for an XC2-32R-E model, including connecting a button and an indicator light.
4.1 Power Supply Wiring
Connect the AC220V power supply to the L (Live) and N (Neutral) terminals on the PLC. Ensure the power source matches the PLC's voltage requirements.
4.2 Input Wiring
The input terminals (X0, X1, X2, etc.) are used to receive signals from external devices such as buttons or sensors. For direct connection, the COM terminal should be connected to the X-terminal. The PLC itself provides a 24V/0V power output that can be used for input devices.
4.3 Output Wiring
The output terminals (Y0, Y1, Y2, etc.) control external devices like indicator lights or relays. The output terminals are grouped with common terminals (COM0, COM1, COM2). For example, COM0 is the common terminal for Y0 output, COM1 for Y1, and COM2 for Y2, Y3, Y4, Y5. For NPN output, connect the common terminal to 0V.
4.4 Communication Wiring
The PLC features A and B terminals for 485 communication, allowing connection to other devices for data exchange.
5. Operation
Once wired and powered, the PLC operates according to the loaded program. The front panel features indicator lights:
- PWR (Power): Indicates that the PLC is receiving power.
- RUN (Run): Indicates that the PLC program is executing.
- ERR (Error): Indicates a system error or fault.
As demonstrated in the wiring video, a simple program can be loaded where pressing an input button (connected to X0) activates an output (Y0), illuminating an indicator light. The PLC will respond to input signals based on the programmed logic.
6. Maintenance
To ensure the longevity and optimal performance of your XINJE PLC, follow these maintenance guidelines:
- Keep the PLC clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Regularly check all wiring connections for tightness and signs of wear or corrosion.
- Ensure proper ventilation around the PLC to prevent overheating.
- Avoid exposing the PLC to direct sunlight, extreme temperatures, or high humidity.
7. Troubleshooting
If you encounter issues with your XINJE PLC, perform the following basic checks:
- No Power (PWR light off): Check the power supply connections (L and N terminals) and ensure the AC220V source is active.
- ERR Light On: This indicates a system error. Consult the detailed programming manual for specific error codes and resolutions.
- Input/Output Not Responding: Verify the wiring for input (X-terminals and COM) and output (Y-terminals and COM) devices. Ensure the program logic is correct and loaded properly.
- Intermittent Operation: Check for loose connections, power fluctuations, or environmental interference.
8. Specifications
| Property | Value |
|---|---|
| Material | PP |
| Origin | Mainland China |
| Certification | CE |
| High-concerned chemical | None |
8.1 XC3 Series Performance Specifications
| Item | Specification |
|---|---|
| Program Execution Method | Cyclic Scan Method |
| Programming Method | Instruction, Ladder Diagram (both available) |
| Processing Speed | 0.5 μs |
| Power-off Retention | FlashROM & Button Battery |
| User Program Capacity | 128 KB |
| Total I/O Points | 14 to 60 points (depending on model) |
| Input Points (DC24V) | X0-X7 (8 points), X0-X15 (16 points), X0-X21 (22 points), X0-X27 (28 points), X0-X33 (34 points), X0-X43 (44 points) |
| Output Points (R, T) | Y0-Y5 (6 points), Y0-Y11 (12 points), Y0-Y15 (16 points), Y0-Y21 (22 points), Y0-Y23 (24 points), Y0-Y27 (28 points) |
| Internal Coils (X) | 544 points: X0-X1037 |
| Internal Coils (Y) | 544 points: Y0-Y1037 |
| Internal Coils (M) | 8768 points: M0-M2999 (M3000-M7999 special use) |
| Flow (S) | 1024 points: S0-S511 (S512-S1023) |
| Timers (T) | 640 points: T0-T99 (100ms non-cumulative), T100-T199 (100ms cumulative), T200-T299 (10ms non-cumulative), T300-T399 (10ms cumulative), T400-T499 (1ms non-cumulative), T500-T599 (1ms cumulative), T600-T639 (1ms precision timer) |
8.2 XC3 Series Model I/O Configuration
| Type | Model | Output Type | Input Points (DC24V) | Output Points (R, T) |
|---|---|---|---|---|
| AC Power (NPN) | XC3-14R-E | Relay Output | 8 points | 6 points |
| XC3-14T-E | Transistor Output | 8 points | 6 points | |
| XC3-14RT-E | Transistor/Relay Mixed Output | 8 points | 6 points | |
| XC3-24R-E | Relay Output | 14 points | 10 points | |
| XC3-24T-E | Transistor Output | 14 points | 10 points | |
| XC3-24RT-E | Transistor/Relay Mixed Output | 14 points | 10 points | |
| ... (other NPN AC models) | ... | ... | ... | ... |
| AC Power (PNP) | XC3-42PR-E | Relay Output | 24 points | 18 points |
| XC3-42PT-E | Transistor Output | 24 points | 18 points | |
| XC3-42PRT-E | Transistor/Relay Mixed Output | 24 points | 18 points | |
| DC Power (NPN) | XC3-14R-C | Relay Output | 8 points | 6 points |
| XC3-14T-C | Transistor Output | 8 points | 6 points | |
| XC3-14RT-C | Transistor/Relay Mixed Output | 8 points | 6 points | |
| XC3-24R-C | Relay Output | 14 points | 10 points | |
| XC3-24T-C | Transistor Output | 14 points | 10 points | |
| XC3-24RT-C | Transistor/Relay Mixed Output | 14 points | 10 points | |
| ... (other NPN DC models) | ... | ... | ... | ... |
| DC Power (PNP) | XC3-42PR-C | Relay Output | 24 points | 18 points |
| XC3-42PT-C | Transistor Output | 24 points | 18 points | |
| XC3-42PRT-C | Transistor/Relay Mixed Output | 24 points | 18 points |
9. User Tips
- Programming: To program the PLC, you will need the appropriate XINJE programming software. Refer to the software's documentation for detailed instructions on creating and uploading programs.
- Input/Output Testing: When testing inputs and outputs, ensure that the power supply to the external devices is correctly configured (e.g., 24V for indicator lights).
10. Warranty and Support
XINJE products are covered by a manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please contact your local distributor or the XINJE customer service department. Keep your purchase receipt as proof of purchase.