1. Introduction
This manual provides detailed instructions for the VOTOL EM150 Electric Motor ECU Controller and the N1S LCD One-LIN Sensor Display. It covers software installation, controller connection, parameter adjustments, operational modes, and troubleshooting.
1.1 Kit Contents
- 1 x EM-150 Controller with USB cables
- 1 x N1S LCD Display

Figure 1: VOTOL EM150 Controller and N1S LCD Display Kit
1.2 Important Safety Information & Disclaimer
It is forbidden for non-specialists to use this product or operate its software. For the IV generation of EM series controller program updates and parameter adjustment, operations can only be done by professional and technical personnel. Without written permission from the manufacturer, application updates or parameter adjustments are not allowed. The company will not be responsible for accidents caused by unauthorized use or operation.
2. Specifications
2.1 EM-150 ECU Sine Wave Controller
| Feature | Specification |
|---|---|
| Model | EM-150 ECU Sine Wave Controller |
| Available Battery Voltage | 48V-72V |
| Rated DC Current | 160A |
| Boost DC Current | 275A |
| Peak Phase Current | 380A |
| Max. Power | 19800W |
| Mosfets Detail | 24 FET |
| Matched Motor Rated Power | 3KW-4KW |
| Max. Efficiency | 93% |
| Degree of Waterproof | IP67 |
| Flux Weakening Ratio | 200% |
| Certification | CE, CCC |
| Working Communication | Hall Sensor |
| Net Weight | 2.1 kg |
| Dimensions (L*W*H) | 245mm * 129mm * 69mm |
| Programmable | Yes, by PC |
| Material | Aluminum Plastic |
| Design | Programmable Sine Wave |
| Origin | Mainland China |

Figure 2: EM150 Controller Dimensions
2.2 N1S LCD Display
| Feature | Specification |
|---|---|
| Speed Sensor Type | One-LIN |
| Speed Units | KMH and MPH switchable |
| Supported Voltage | 48V, 60V, 72V, 84V, 96V Li-ion battery |
| Shell Size | 21cm * 11cm * 9cm |
| Displayed Data | Speed (Max 188kmh), Voltage, Battery Level, Trip distance, Head lighting, Gear, Fault Display, Turning lighting |

Figure 3: N1S LCD Display Dimensions and Rear View

Figure 4: N1S LCD Display with Labeled Components
3. Setup
3.1 Software Installation (Windows 7/10)
- USB Driver Installation: Download and decompress the "USB-to-serial-win 10-20150814" file. Choose the suitable driver for your computer (Win 7/10 are supported; iOS and XP are not). If using an abroad PC system, remove any Chinese characters from the file name.
- Software Installation: For versions from 2018.7 onwards, simply install the USB driver and open the software directly. For older versions, copy the `TeeChart5.ocx` file to the C drive root directory. Then, run the setup to register the file and execute the `EM_V3` program.
3.2 Controller Connection
- Power on the controller and ensure the ignition is closed.
- If your controller supports CAN, enable "CAN enable" in the software and click "Open".
- Click the "research" button in the software, then select the correct serial port (usually the last one). Click "open series port"; the device status should show "connected".
- Key on the ignition, then click "connect" to the controller (it is recommended to click more than once).
3.3 N1S LCD Display Wiring
Connect the N1S LCD Display to the controller using the following wiring scheme:
- Red: Positive 48V-96V +
- Black/Green: Negative GND -
- Purple: ONE-LIN Speed Sensor
- Dark Blue: Head Light
- Orange: Left Turn Signal Light
- Light Blue: Right Turn Signal Light
- Black Plug 1: KMH/MPH Switching
- Black Plug 2: Voltage Switching (Default 72V/60V switching; other voltages can be specified when ordering)

Figure 5: Controller Wiring Harness with Labeled Functions
3.4 Initial Parameter Adjustments
After connecting, adjust the following parameters in the software:
- Battery Voltage: Adjust the voltage parameter according to your battery. Note: Adjusting this without hardware support will damage the controller.
- Under-voltage and Soft Under-voltage: Fill in the required under-pressure protection parameters. The controller enters hardware under-voltage protection at the set threshold. Soft under-voltage is typically 3V above the under-voltage setting.
- Battery Current and Phase Current Limits: Set the busbar current and phase current limits. Refer to the provided table for safe ranges for different EM models. Do not set values outside the specified range, as this will damage the controller.
- Throttle Voltage: Adjust low protection, starting voltage, end voltage, and high protection values.
- Start Setting (Tricycle Gearbox Only): Adjust starting torque, combined torque, and upward/downward motor torque slopes.
- Temperature Protection: Set start, over-temperature, recovery, and maximum temperature values for controller and motor protection.
- Hall Speed Setting: For EM30S/50S/100S/150S models with Hall Type Display, select "IO" and "F", "13: Hall" in the port setting interface.
- Three Speed Setting: For EM30S/50S/100S/150S models, three speeds are achieved by switch (PD0-low, PD1-high, PB3-middle) or button (PD1-egear, PB3-sport). For EM200S, PA0-low, PB2-high.
4. Operation
4.1 Sports Mode (S Gear) Parameters
Configure current limiting, flux weakening values, automatic logout enablers, and recovery time for sports mode. When the controller enters S gear, battery current increases for more powerful climbing.
4.2 Downhill Electric Brake Assist (HDC/HHC)
Enable HDC to maintain constant speed and stable RPM on steep slopes. Set the HDC lowrst speed within 110%-120% of the motor's real RPM. Do not set it significantly higher than the motor's RPM.
4.3 Speed Limit Setting
Enable the speed limit function and set the speed ratio (0-100%). This can be customized via a sport wire or speed limit function.
4.4 Flux Weakening & Three Speed Settings
Adjust flux weakening compensation and configure three-speed modes (button or switch). Soft start can be enabled with a grade from 1 to 16 (lower value means softer start).
4.5 Motor Settings
Correctly input motor pole pairs for accurate RPM acquisition. Fill in the motor type (e.g., middle drive motor) for motor matching. Adjust the Hall phase shift angle (-180 to 180 degrees) for controller and motor phase adjustment. Use values like -180, -120, -60, 0, 60, 120, 180 for testing. To change running direction, add or subtract 120 degrees from the correct data.
4.6 Speedometer Output
The controller supports two types of speedometer output: ONE-LIN and Hall speedometer. Select the type compatible with your vehicle's speedometer.
4.7 Moving Assist and Cruising Function
- Moving Assist: Enable this function. The assist speed is a percentage of the motor base speed (default 10%).
- Cruise Function: Enable this function. To activate, maintain a certain throttle angle for more than 8 seconds. Any operation (e.g., braking, twisting throttle) will exit cruise mode.
4.8 Dual Voltage Adaptive Function
Enable dual voltage adaptive function for automatic switching between low and high voltage modes based on battery voltage thresholds.
4.9 Reversing, EBS, Low Brake, and Safety Switch
- Reversing Speed Limit: Adjust the reverse speed limit (0-100%). Do not exceed 30% to avoid accidents.
- EBS Ratio: Adjust the electronic brake force (0-100%).
- Low Brake: Enable low brake function.
- Safety Switch: Enable the safety switch function. When active, the safety switch must be pressed before starting the vehicle.
4.10 Remote Operation
Remote operation, including software updates, current calibration, and debugging, should only be performed under the guidance of a company engineer. To update software, click "opening file", select the ".bin" file, and click "download".
5. Maintenance
5.1 Controller and Motor Testing
While controllers and motors are tested before shipment, periodic checks can help ensure proper functioning. If you suspect an issue, refer to the troubleshooting section.

Figure 6: Controller and Motor Testing Setup
5.2 Testing Controller Hall Error
If the controller shows a Hall fault, you can test the Hall sensor voltage:
- Connect the positive and negative battery terminals to the controller.
- Ensure the ignition is connected and power is on.
- Measure the positive and negative poles of the controller Hall. It should read around 5V. If the voltage is significantly different (e.g., 0.9V), the Hall port may be damaged.
Incorrect wiring of the Hall plug, or using a motor Hall plug with a different color sequence, can damage the Hall port if connected directly without verifying polarity.
6. Troubleshooting
6.1 Software Installation Issues
- Software Cannot Install: Try changing your computer's system language to English or Chinese. This issue can arise from C++ runtime differences in various PC systems.
- Software COM Port Cannot Find: If your computer has COM information but the software doesn't show it, there might be a driver problem. Reinstall the correct driver (e.g., FT232 Driver).
6.2 Controller Communication Issues
If the controller cannot communicate with the software, you can try to re-flash the firmware:
- Close the ignition.
- Open the debugging software, open the serial port (no need to click "connect").
- Open the "CAN.Bin" file.
- Then connect normally.
6.3 Controller Fault or Hall Error
- If the software shows a controller fault but the vehicle runs normally, there is no actual problem with the controller.
- If the controller cannot run and the software shows a Hall error (with Hall connected), check the plug connection. If the connection is good, perform the Hall sensor voltage test (Section 5.2).
6.4 Reverse Function Not Working
If the reverse function wire is connected correctly and the display shows 'R' gear, but the motor doesn't reverse, check your software parameters. Sometimes, there might be two ports configured for reverse; remove one to empty it.
6.5 Stop Twist Throttle, Motor Still Running
If the motor continues to run after releasing the throttle, try adjusting the Hall shift data. Experiment with values like -60 to 120, following the motor setting guide (Section 4.5).
7. User Tips
- Motor Noise/Shock: If your motor experiences shock or noise, adjust the flux weakening value (marked in blue in the software) to a value lower than 800. This will not reduce speed.
- Parameter Ranges: Always ensure that setting values are within the specified ranges. Exceeding these ranges can damage the controller or cause motor demagnetization.
- Flux Weakening Function: If you do not require the flux weakening function, set its value between 200-500.
- Soft Start: A lower soft start grade (1-16) results in a softer start.
- Reversing Speed: For safety, do not set the reversing speed limit above 30%.
- Initial Setup: For initial testing, ensure phase and Hall wires are correctly connected. Hall shift is crucial; experiment with values from -180 to 180.
- Speed Limit Activation: To set a permanent speed limit without a switch, connect the speed limit wire directly to GND after configuring the speed limit percentage in the software.
8. Warranty & Support
8.1 Warranty Information
A 1-year warranty is offered for motors and controllers. The buyer is responsible for return shipping costs for repairs or replacements. The warranty does not cover man-made damage. If you lack knowledge in electric kit assembly, please consider this carefully before purchase.
8.2 Additional Resources
For further detailed programming instructions, you may refer to the official EM Controller Program Manual (PDF) available at: EM Controller Program Manual (PDF).
8.3 Contact Support
If you encounter any problems or require assistance, please contact the seller or manufacturer's support team. They will endeavor to provide help and solutions.