Signal Fire ZS-20C-V20

Contents

Signal Fire ZS-20C-V20 Optical Power Meter Kit User Manual

Model: ZS-20C-V20

1. Introduction

The Signal Fire ZS-20C-V20 is a versatile 4-in-1 mini multifunctional optical power meter designed for efficient and accurate fiber optic network testing, particularly in FTTH (Fiber to the Home) applications. This compact, handheld device integrates an Optical Power Meter (OPM), Visual Fault Locator (VFL), LED light, and Cable Test functionality, making it an essential tool for technicians.

This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your ZS-20C-V20 device. Please read it thoroughly before use to ensure optimal performance and safety.

2. Key Features

  • 4-in-1 Functionality: Integrates Optical Power Meter (OPM), Visual Fault Locator (VFL), LED light, and Cable Test (Wire Tracker) in one compact unit.
  • Compact and Portable: Features a 4.7-inch compact body, designed for comfortable grip and easy portability.
  • High-Precision OPM: Supports calibrated wavelengths of 850/1300/1310/1490/1550/1625nm with an accuracy of ±0.2dB. Equipped with a 2.5mm universal connector for FC/SC/ST adapters.
  • Stable VFL Light Source: Provides a stable and strong light source to easily penetrate long-distance optical fibers, improving work efficiency.
  • Data Storage: Capable of storing up to 500 test records, allowing for easy review and analysis.
  • Type-C Interface: Modern Type-C port for convenient and universal charging.
  • Backlight Screen: Ensures visibility in dim surroundings.
  • Wavelength Memory: Retains the last used wavelength setting upon power-on.
  • Long-lasting Battery: Powered by a Lithium battery with 3 hours quick charge, up to 60 hours of use (OPM only), and 90 days extra-long standby in full power shutdown state.
  • Built-in Cable Test Module: Features an integrated remote module for network cable (RJ-45) testing.
  • LED Flashlight: High-brightness LED small flashlight for illuminating work areas in dark environments.
  • User Self-Calibration: Allows for DIY adjustment of the OPM for more flexible and accurate measurements.
  • Energy Saving: Automatic shutdown after 10 minutes of inactivity to conserve battery life.

3. Package Contents

Upon opening the package, please verify that all items are present and in good condition:

  • ZS-20C-V20 Optical Power Meter (OPM) x1
  • User Manual x1
  • Type-C Charging Cable x1
  • Lanyard x1
  • Storage Box x1
Image showing the Signal Fire ZS-20C-V20 Optical Power Meter, its box, Type-C cable, lanyard, and manual.
Figure 3.1: ZS-20C-V20 Package Contents

4. Product Overview and Initial Setup

4.1 Device Layout

Front, back, and side views of the Signal Fire ZS-20C-V20 device, showing its compact size and ports.
Figure 4.1: ZS-20C-V20 Front, Back, and Side Views

The device features a clear LCD display and intuitive button layout for easy operation. Key components include:

  • Display Screen: Shows measurement readings, selected wavelength, battery status, and other indicators.
  • ON/OFF Button: Powers the device on/off and controls backlight.
  • VFL Button: Activates and cycles through Visual Fault Locator modes.
  • Wavelength Button: Selects OPM measurement wavelengths.
  • Save Button: Stores current measurement data.
  • REF Button: Switches units or sets/checks reference values.
  • LED Button: Turns the built-in flashlight on/off.
  • USB Type-C Port: For charging the device.
  • OPM Port: Input for optical power measurement.
  • VFL Port: Output for Visual Fault Locator.
  • RJ-45 Port & Remote Module: For network cable testing. The remote module is integrated into the device.

4.2 Charging the Device

Before first use, ensure the device is fully charged. The ZS-20C-V20 is equipped with a Lithium battery and a Type-C charging interface.

  1. Locate the Type-C charging port on the device.
  2. Connect the provided Type-C charging cable to the device and a standard USB power adapter (not included).
  3. The battery indicator on the display will show charging status. A full charge typically takes 3 hours.
Image showing the Type-C charging port and various charging scenarios, along with battery life details.
Figure 4.2: Type-C Interface and Lithium Battery

5. Operating Instructions

5.1 Power On/Off and Backlight

  • Power On: Short press the ON/OFF button.
  • Power Off: Long press the ON/OFF button until the screen turns off.
  • Backlight: While the device is on, short press the ON/OFF button to toggle the screen backlight.
  • Energy Saving (Auto-off): The device has an auto-off function after 10 minutes of inactivity. To disable this, long press the ON/OFF button until a clock icon appears on the screen when turning on the device.
Image illustrating the backlight function and user self-calibration process.
Figure 5.1: Backlight and Self-Calibration

5.2 Visual Fault Locator (VFL) Function

The VFL function helps identify breaks, bends, or poor connections in fiber optic cables.

  1. Connect the fiber optic cable to the VFL port on the device.
  2. Short press the VFL button to cycle through output modes: ON (continuous light), GLINT (flashing light), and OFF.
  3. Observe the fiber for any visible red light leakage, which indicates a fault.
Image showing the VFL function in use, emitting a red light into a fiber optic cable.
Figure 5.2: VFL Function in Operation

5.3 Optical Power Meter (OPM) Function

The OPM measures the optical power of a fiber optic signal.

  1. Connect the fiber optic cable to the OPM port on the device.
  2. Short press the Wavelength button to select the desired measurement wavelength (850nm, 1300nm, 1310nm, 1490nm, 1550nm, or 1625nm). The device will remember the last used wavelength.
  3. The display will show the measured optical power in dBm and mW.
  4. Short press the REF button to switch between displaying the current measurement unit or checking the reference (REF) value.
Image showing the OPM function measuring optical power from a fiber connected to a router.
Figure 5.3: OPM Function in Use

5.4 Test Data Storage and Review

The device can store up to 500 sets of measurement data.

  1. After performing an OPM measurement, long press the Save button (labeled '>2s Save') to store the current test data.
  2. To review stored data, short press the Save button. Use the up and down arrow keys (integrated with VFL and Wavelength buttons) to scroll through the records.
Image illustrating the data storage and review feature, showing multiple measurement records on the screen.
Figure 5.4: Data Storage and Review

5.5 Cable Test (Wire Tracker)

The integrated remote module allows for testing of network cables (RJ-45).

  1. To use the cable test function, first pull out the remote cable module from its slot on the bottom of the main unit by pressing the lock key.
  2. Connect one end of the network cable (RJ-45) to the main unit's RJ-45 port and the other end to the remote module.
  3. Long press the ON/OFF button to enter/exit cable test mode. The display will show the wiring status (e.g., RJ45, indicating pin connections).
  4. After testing, push the remote module back into the main unit until it locks tightly.
Image showing the remote cable module being detached and used for network cable testing, and the LED flashlight function.
Figure 5.5: Cable Test Module and LED Flashlight

5.6 LED Flashlight

The device includes a high-brightness LED flashlight for convenience in dark environments.

  • Short press the LED button (flashlight icon) to turn the LED light on or off.

5.7 User Self-Calibration

The OPM can be calibrated by the user for more flexible measurements.

  1. Ensure the device is powered OFF.
  2. Long press the ON/OFF button and the Wavelength button simultaneously for approximately 2 seconds. This will enter the offset setting interface.
  3. Use the up and down arrow keys (integrated with VFL and Wavelength buttons) to adjust the offset value. The adjustable range is typically [-5, +5] dB, with a support range of ±0.5dB for fine-tuning.
  4. Short press the ON/OFF button to confirm and save the new calibration setting.
Video 5.6: Demonstration of ZS-20C-V20 functions including OPM, VFL, Wire Tracker, LED lights, and OPM calibration.

6. Maintenance

  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning the exterior. Avoid using abrasive cleaners or solvents.
  • Optical Ports: Always ensure the OPM and VFL ports are clean before connecting fiber optic cables. Use appropriate fiber optic cleaning tools (e.g., fiber cleaning sticks or wipes) to prevent inaccurate measurements or damage.
  • Storage: Store the device in a cool, dry environment, away from direct sunlight, extreme temperatures, and high humidity. When not in use, keep the protective caps on all ports.
  • Battery Care: For long-term storage, charge the battery to about 50% and recharge every few months to prevent deep discharge.

7. Troubleshooting

ProblemPossible CauseSolution
Device does not power onLow or depleted batteryConnect the device to a Type-C charger and allow it to charge.
Inaccurate OPM readingsDirty optical connectors/ports; Incorrect wavelength selected; Device needs calibrationClean optical connectors and ports. Ensure the correct wavelength is selected. Perform user self-calibration if necessary.
VFL not emitting lightVFL function is off; Fiber not properly connected or severely damagedShort press the VFL button to turn it on. Ensure the fiber is securely connected. Check the fiber for severe damage.
Cable Test (Wire Tracker) failureLoose RJ-45 connections; Remote module not properly inserted/detachedEnsure both ends of the RJ-45 cable are securely connected to the main unit and the remote module. Verify the remote module is correctly detached for testing and re-inserted for storage.
Screen is dim or unreadableBacklight is off; Low batteryShort press the ON/OFF button to activate the backlight. Charge the device if the battery is low.

8. Specifications

ParameterValue
ModelZS-20C-V20
PD TypeInGaAs
OPM Connector2.5mm Universal connector (for FC/SC/ST)
Calibrated Wavelengths850/1300/1310/1490/1550/1625nm
Display Range-50~+30dBm
Resolution0.01dB
Accuracy*±0.2dB
Modulation Test270/330/1k/2kHz
VFL Connector2.5mm Universal connector
VFL Power20mW
LEDYes
RJ-45 Cable TestYes
InterfaceType-C
BatteryLithium battery
Storage Temperature-20~60°C, < 90%RH
Operating Temperature-10~50°C, < 90%RH
Weight95g
Size100mm×59mm×28mm

*Accuracy measured at 20±3°C, CW, with FC connector, -10dBm.

9. User Tips

No specific user tips were available from customer reviews or Q&A at the time of manual creation.

10. Warranty and Support

This Signal Fire ZS-20C-V20 Optical Power Meter Kit is backed by a 1-year warranty, ensuring quality and reliability. For technical support, service, or warranty claims, please retain your purchase receipt and contact your vendor or the manufacturer directly. Our professional engineers are available to assist with any after-sale service needs.