1. Introduction
Thank you for choosing the HOMCOM 1500W 7 Fin Oil Filled Heater Radiator. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new heater. Please read this manual thoroughly before use and retain it for future reference.
This oil-filled radiator is designed to provide fast, quiet, and powerful heating for spaces up to 20㎡. Its seven-fin design, combined with oil filling, ensures quick preheating in just 10 minutes. With adjustable power settings and temperature control, you can customize your comfort.
2. Safety Instructions
Your safety is paramount. Please observe the following precautions:
- Always place the heater on a firm, level surface.
- Ensure adequate clearance around the heater (at least 1 meter from walls, furniture, and flammable materials).
- Do not cover the heater or block its air vents.
- Keep children and pets away from the heater, especially when in operation.
- Do not operate the heater near water or in damp environments.
- Always unplug the heater when not in use or before cleaning.
- Never pull the power cord to unplug the heater.
- This heater is equipped with Tip-Over Protection and Overheat Protection, which will automatically shut off the unit if it tips over or reaches an unsafe temperature. If this occurs, unplug the heater, allow it to cool, and then address the cause before restarting.

3. Package Contents
Upon opening the package, please ensure all components are present and undamaged:
- HOMCOM 1500W 7 Fin Oil Filled Heater Radiator
- Swivel Wheels (pre-attached or requiring simple attachment)
- Instruction Manual (this document)
4. Setup
Follow these steps to set up your oil-filled heater:
- Unpack: Carefully remove the heater from its packaging. Retain packaging for storage or return if necessary.
- Attach Wheels (if not pre-attached): If the swivel wheels are not already attached, carefully turn the heater upside down. Securely attach the wheels to the base of the heater using the provided hardware. Ensure they are firmly in place for stability and mobility.
- Position the Heater: Place the heater on a stable, level surface in the desired room. Ensure there is at least 1 meter of clear space around the heater to allow for proper air circulation and to prevent fire hazards. Do not place it directly under a power outlet.
- Power Connection: Unwind the power cable from the integrated holder. Plug the power cable into a suitable 220-240V, 50-60Hz grounded electrical outlet. Ensure the outlet is in good condition and not overloaded.


5. Operating Instructions
Operating your HOMCOM oil-filled heater is straightforward:
- Power On: Plug the heater into a suitable power outlet.
- Select Heat Setting: Use the power dial on the control panel to select your desired heat output. The available settings are 600W (Low), 900W (Medium), and 1500W (High).
- Set Temperature: Use the thermostat dial to set the desired room temperature, ranging from 7°C to 35°C. The heater will cycle on and off to maintain this temperature.
- Preheating: The oil-filled heater will begin to warm up quickly, reaching optimal heat output within approximately 10 minutes.
- Quiet Operation: The heater operates at a low noise level of 35dB, ensuring a peaceful environment.
- Power Off: To turn off the heater, turn the power dial to the 'OFF' position and then unplug it from the wall socket.




6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your heater:
- Cleaning: Always unplug the heater and allow it to cool completely before cleaning. Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no water enters the internal components.
- Storage: When not in use, especially during off-season, ensure the heater is clean and dry. Wrap the power cable neatly around the integrated cable holder. Store the heater in a cool, dry place, preferably in its original packaging.
7. Troubleshooting
If you encounter issues with your heater, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater does not turn on. | No power to the unit; Power dial is off; Thermostat set too low. | Check power outlet and circuit breaker; Turn power dial to desired setting; Increase thermostat setting. |
| Heater turns off unexpectedly. | Overheat protection activated; Tip-over protection activated. | Unplug, allow to cool, check for obstructions, ensure upright position, then restart. |
| Heater is not heating effectively. | Thermostat set too low; Incorrect power setting; Room size exceeds heater capacity. | Increase thermostat setting; Select a higher power setting (e.g., 1500W); Ensure heater is appropriate for room size (up to 20㎡). |
If the problem persists after attempting these solutions, please contact customer support.
8. Specifications
| Feature | Specification |
|---|---|
| Brand | HOMCOM |
| Model Number | 820-439V70BK |
| Power (W) | 600W / 900W / 1500W |
| Temperature Range | 7-35°C |
| Suitable Acreage | Up to 20㎡ |
| Preheating Time | Approx. 10 minutes |
| Working Noise | 35dB |
| Power Cable Length | 1.5m |
| Input | 220-240V, 50-60Hz |
| Material | Steel, Plastic |
| Overall Dimensions (W x D x H) | 29cm x 40cm x 62cm |
| Color | Black |
| Energy Standard | Meets energy-saving ERP standards |

9. User Tips
To maximize the efficiency and comfort provided by your HOMCOM oil-filled heater:
- Optimal Placement: Position the heater in the coldest part of the room or near areas where you spend the most time to feel the heat directly.
- Thermostat Use: Utilize the thermostat to maintain a consistent temperature rather than constantly turning the heater on and off. This can save energy and provide more stable warmth.
- Insulation: Close doors and windows in the room being heated to prevent heat loss and improve efficiency.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the purchase documentation or contact the retailer/manufacturer directly. Keep your proof of purchase for any warranty claims.