FDIK FDIK V-Series

FDIK V-Series Diesel Air Parking Heater User Manual

Models: 2KW, 5KW

Brand: FDIK

1. Introduction

Thank you for choosing the FDIK V-Series Diesel Air Parking Heater. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

Key Features:

  • Durable Aluminum Shell for efficient heat dissipation.
  • Energy-saving design with fast heating capabilities.
  • Advanced FDIK-C24 External Switch for precise control.
  • Temperature and Power Protection features for enhanced safety.
  • Variable Frequency Motor for optimized performance.
  • High-quality Silicon Nitride Ceramics for fast and reliable heating.
  • 309S Material Casting ensures full combustion of fuel.
  • Accurate Flow Fuel Pump for efficiency and durability.
  • Universal Voltage (12V) compatibility.
  • Overheating Protection and Temperature Mode for user comfort and safety.
FDIK V-Series Aluminum Shell Heater with feature icons
FDIK V-Series Aluminum Shell Heater highlighting key features like aluminum shell, energy saving, and fast heating.

2. Package Contents

Please check the package contents upon receipt to ensure all components are present:

Image showing all components included in the FDIK Diesel Parking Heater package
All components included in the FDIK Diesel Parking Heater package.
  • Heater Unit (2KW or 5KW)
  • Controller x 1
  • Remote Controller x 1
  • Tubing x 1
  • Exhaust Pipe x 1
  • Fuel Tank (5KW 8.8L x 1)
  • Oil Filter x 1
  • 75mm Wind Head x 1
  • Air Filter x 1
  • Silencer x 1
  • Oil Pump x 1
  • Buckle x 4
  • Wire Harness x 1

3. Installation and Setup

Proper installation is crucial for the safe and effective operation of your heater. Refer to the diagram and instructions below.

3.1 Installation Diagram

Installation Diagram and Position for FDIK Diesel Heater
Detailed installation diagram showing wiring, air inlet/outlet, exhaust pipe, and fuel pump connections, along with recommended installation positions for various vehicles.

Wiring: The positive and negative main wires must be connected to the battery to ensure normal operation of the main unit. The switch connects to the main wire harness.

Air Inlet/Outlet: The air inlet and air outlet must be reserved for air circulation. Ensure they are not blocked. If the air inlet and outlet are too close, they may cause recirculation.

Fuel Pump: The oil pump is preferred to be installed between 15° and 35° from horizontal.

3.2 Recommended Installation Positions

  • Truck: 1. On the co-driver's legroom. 2. On the back wall of the cab. 3. Driver's seat backrest. 4. Within the tool box.
  • RV: 1. In front of the passenger seat. 2. Between the driver's seat and passenger seat. 3. Under the container. 4. In the trunk.
  • 5 Seater / 7 Seater: The heater is mainly installed in the passenger room or luggage room of the vehicle. If it cannot be installed, fix the heater under the underside of the vehicle, but beware of splashing.
  • Excavator: 1. Inside the driver's seat. 2. On the back wall of the cab. 3. Inside the protection box.

4. Operating Instructions (C24 Three-Key Digital Controller)

FDIK-C24 External Switch (controller) display
FDIK-C24 External Switch (controller) showing temperature and power protection displays.

4.1 Quick Remote Matching

When the device is off, press and hold the up and down buttons simultaneously on the controller. The screen will display a 10-second countdown, entering remote control matching mode. Within 10 seconds, press any button on the remote to successfully pair it.

4.2 Operations in Power-On State

  1. Power On/Off: Press the Power On/Off button once to turn the device on. Press it again to turn it off.
  2. Air Conditioning Mode (Temperature Mode): While the device is on, press and hold the Power On/Off button for 3 seconds to switch to Temperature Mode, with a range from 10°C to 35°C. Use the Gear Increase and Decrease buttons to set the desired temperature. The set temperature must be higher than the current ambient temperature. When the device reaches the set temperature, it will reduce to a lower combustion speed. If the temperature is not reached, the device will increase the combustion speed to meet the set temperature.
  3. Power Mode: In Air Conditioning Mode, press and hold the Power On/Off button for 3 seconds to switch back to Power Mode. Adjust the power level using the Gear Increase and Decrease buttons, with levels P1 to P5 (5 levels).

4.3 Functions in Power-Off State

  1. Normal Power-On: In the off state, press and hold the Power On/Off button for 5 seconds. The screen will display "ON". Release the button to power on normally.
  2. Automatic Oil Pump Start: In the off state, press and hold the Power On/Off button for 5 seconds until the screen displays "Po". Release the button; the ignition plug will preheat for 1 minute before the oil pump starts. Once the oil line is full, the device will automatically ignite and enter normal combustion. If the oil line is not filled after one attempt and the fan is still running, the screen will display "Po" flashing. Press the Power On/Off button again to start a second oil pumping attempt.
  3. Ventilation Function: Press and hold the Power On/Off button until the screen displays “Fn”. Release the button; the screen will show "F1" to "F5" which can be adjusted to provide ventilation for the cabin.
  4. Remote Control Matching: Press and hold the Power On/Off button until the screen shows “R1”. Release the button, and within 10 seconds, press any button on the remote to successfully pair it.
  5. Manual Oil Pumping via Remote: Long press the 5th display icon on the screen of the power key, "rp". Release the button, and the screen will display "20", indicating the function will turn off after 20 minutes. Press the remote's power button to start oil pumping; press the remote's power button again to stop oil pumping. Note: 1. This function does not support ignition. Monitor the oil line and stop pumping once it is full. 2. After using this function, the paired remote needs to be re-matched.
  6. Language Selection and Do Not Disturb Mode: Long press the 6th display icon on the screen of the power switch, "LA". Release the button, then use the Gear Increase and Decrease buttons to select the language. The screen will display options such as “CH” (Chinese) or "BP" (Silent). Select the desired language by adjusting the knob to set it successfully.
  7. Emergency Start: If the device switch is damaged, first disconnect three switch wires (black, blue, and red). Short the black and blue wires together at a regular frequency 7 times (1-2-3-4-5-6), then do not release on the 7th time but hold for 1 minute. If the mainboard is not damaged, the device will start normally.

4.4 Advanced Settings

  1. Setting Temperature Mode and Oil Pump Flow: Disconnect the power switch wire. Then, press and hold the power switch button without releasing it. Next, reconnect the power switch wire. The screen will display "CF" followed by a number. Release the button. Multiply the displayed number by 5 and add 1. For example, if the number displayed is 2, then 2 * 5 + 1 equals 11. Press the up button to select the last digit (in this case, 1), then press the power switch button to enter the settings function.
    The first screen that appears is: Power Voltage, which sequentially shows 24V Power, -12V Power, and 0A Automatic Voltage. Press the power switch button to confirm in the 0A state. The voltage will automatically match.
    Next, the screen will show 22, which indicates a 22 oil pump. Press the up button to display 28, which indicates a 28 oil pump. Press the up button again to show 0A, which is for automatic oil pump matching. Select the desired oil pump flow rate and press the power switch button to confirm the oil pump setting.
    Once the oil pump is set, the screen will display "t5" to indicate the temperature mode shutdown function. "t----" turns off the temperature mode shutdown function. If you want to enable it, in the "t5" state, press the power switch button to confirm.
    After all settings are completed, the screen will display "5u" after 5 seconds and then shut down, indicating that all settings are completed.
  2. Clear Current Remote Configuration: Disconnect the switch wires, press and hold the Power On/Off button, and reconnect the switch wires. The screen will display "CF". Release the button, then press the Power On/Off button to clear the configuration.

5. Maintenance

To ensure optimal performance and longevity of your FDIK Diesel Air Parking Heater, regular maintenance is recommended:

  • Regularly check fuel lines for any leaks or blockages.
  • Inspect the air inlet and exhaust pipes for obstructions and ensure they are clear.
  • Clean the air filter periodically to prevent dust buildup and maintain efficient airflow.
  • Ensure all electrical connections are secure and free from corrosion.
  • Check the fuel pump for any signs of wear or malfunction.

6. Troubleshooting (FDIK C3 Fault Code Manual)

If you encounter issues with your heater, refer to the fault code table below for diagnosis and solutions:

Error CodeProblemSolution
0Panel failureReplace the panel.
1Ignition failure failed
  • Check if the fuel tank is low on oil or fuel is exhausted.
  • Check if the oil pump is stuck or abnormal.
  • Verify the oil circuit is correct, free of bubbles, and oil supply is continuous.
  • Check for poor power supply or oil quality issues.
2Flame out
  • Check for oil path leaks or bubbles in the oil supply.
  • Ensure the fuel tank is not low on oil, and the oil pump is not abnormal.
3Incorrect power supply voltage (Under-voltage or over-voltage)
  • Ensure the power cord is correctly connected and voltage matches the machine's requirements.
  • Check for secure connector insertion and good contact of the power cord.
  • Inspect the fuse box for poor contact.
  • Verify the panel's configuration matches the vehicle's voltage.
  • Avoid substandard or extra electrical cables.
  • Ensure the power converter supplies enough current and has stable output voltage.
6Intake air over-temperature
  • Check if the room temperature is too high.
  • Ensure proper air circulation and avoid cycling of the machine's air outlet and inlet.
  • Verify installation space is not too narrow.
7Oil pump problem
  • Ensure the oil pump is properly connected, and the connection line is not open or short-circuited.
  • Check if the 5-pin socket panel is properly plugged in.
  • Inspect for disconnection in the oil pump circuit or oil pump fault.
8Fan (motor) problem
  • Check if fan blades are stuck.
  • Inspect for incorrect speed check (motor repeats 3 times to report fault).
  • Check for internal motor fault.
  • Ensure the motor socket is properly plugged in.
9Ignition shorted plug
  • Check if the ignition pin is short-circuited or the connection wire is reversed.
  • Inspect for insulation damage at the end of the ignition plug causing a short circuit.
  • Check for ignition plug leakage.
10Overheat
  • Remove obstacles to air circulation or obstructed air ducts.
  • Ensure installation space is not too narrow.
  • Avoid connecting to an oil pump with a large flow rate.
  • Check for oil pump check valve leakage.
  • Inspect the sensor for damage.
11Overheating sensor failureReplace the overheat sensor.
12Ignition plug open circuit
  • Check for poor contact of the ignition plug connector.
  • Inspect if the ignition plug is burned out and needs replacement.

7. Specifications

Detailed technical specifications for the FDIK V-Series Diesel Air Parking Heater:

AttributeSpecification
Brand NameFDIK
Model NameFDIK Aluminum
Item TypeHeating & Fans
MaterialAluminum
FuelDiesel
Voltage12V
Power (W)2000W or 5000W
Switch TypeRotary switch
Special FeaturesHeating
External Testing CertificationCE
Item Length (5KW)40cm (400mm)
Item Width (5KW)14cm (140mm)
Item Height (5KW)14cm (140mm)
Item Diameter (Outlet)7.5cm (75mm)
Item Weight6.5kg
2KW size340*120*120mm
5KW size400*140*140mm

7.1 Performance Data (5000W Model)

Performance specifications table for 5000W heater
Performance specifications for the 5000W heater, based on factory tests.
ParameterValue
Heater Model5000W
Heating mediumAir
Calorific gradeSuper highTopMediumLowClosed
Value (W)500035002000900-
Medium flux (kg/h)1851501106024
Fuel Consumption (liter/hours)0.640.40.280.11-
Power consumption (W)40241377
Lower limit of undervoltage10.5V/21V
Overvoltage limit of undervoltage16V/32V

Note: The data comes from actual factory tests. In actual use, due to the influence of temperature and altitude, the actual data may deviate from the table, which is normal.

8. Warranty and Support

8.1 Warranty Information

Brand Promise details, including warranty information
FDIK Brand Promise outlining warranty and support details.
  • Warranty: One year warranty is provided. Please note that vulnerable parts are not included under warranty.

8.2 Customer Support

For any questions, technical assistance, or support, please contact our customer service:

Customer service contact information via WhatsApp
Customer Service Online via WhatsApp.
  • WhatsApp: +86 18636417766

Additional item guides and documents, including a PDF user manual, may be available. Please refer to the official product page or contact support for access to these resources: User Manual (PDF)

9. User Tips

Based on common user inquiries and feedback, here are some helpful tips:

  • Model Selection: Ensure you select the correct power (2KW or 5KW) for your specific needs. The 2KW model may have slightly different features or accessories (e.g., silencer) compared to the 5KW model. Always verify the product description for your chosen variant.
  • Fuel Quality: Using high-quality diesel fuel is essential for optimal performance and to prevent issues like ignition failure or flame out.
  • Power Supply: Double-check your vehicle's voltage (12V) and ensure stable power delivery to avoid undervoltage or overvoltage errors.
  • Airflow: Keep the air inlet and outlet clear of obstructions to ensure proper ventilation and prevent overheating.

© 2024 FDIK. All rights reserved.