TEKIVI 6839C

Contents

TEKIVI 6839C LCD Digital Voltage Electricity Indicator

User Manual

1. Product Introduction

The TEKIVI 6839C Intelligent Electricity Meter is a high-precision LCD digital display voltage and electricity indicator designed for universal use with ternary, lithium iron, and acid batteries. It features a temperature display, power-off memory, automatic calibration, and voltage alarm reminders to ensure safe and accurate monitoring of your battery systems.

LCD digital voltage and power indicator with voltage and temperature display

Figure 1: Front view of the 6839C Intelligent Electricity Meter displaying voltage, percentage, and temperature.

Key Features:

  • Power-down Memory and Auto-Calibration: Supports data saving after power failure and features an auto-calibration function for long-term accuracy.
  • Battery SOC Curve Import: Allows customized SOC curve import to improve power monitoring accuracy.
  • Voltage Alarm Reminder: Supports setting overcharge and overdischarge thresholds for timely warnings and battery safety.
  • Multi-Type Battery Detection: Compatible with LiFePO4, Li-ion ternary batteries, and acid batteries, with personalized parameter settings.
  • Wide Application: Suitable for computer rooms, caravans, electric vehicles, unmanned base stations, photovoltaic power, AGV, and energy storage equipment.
  • High-Definition Large Screen: Provides clear display with a wide viewing angle.
  • Built-in Storage Chip: Ensures no data loss during power outages.
  • Waterproof Technology: Adopts waterproof technology for enhanced durability (Waterproof model).
Diagram showing 9 major functions including power-off memory, automatic calibration, battery voltage, remaining battery percentage, voltage alarm reminder, real-time temperature monitoring, and various battery type monitoring.

Figure 2: Overview of the 9 major functions of the 6839C Electricity Meter.

Video 1: Product showcase demonstrating the 6839C Electricity Meter from various angles and its display functionality.

2. Specifications

Product Parameters:

Parameter Value
Voltage Measurement Range DC 8-100V
Resolution 0.01V
Detection Temperature -20~80℃
Operating Current ≤ 20mA
Static Power Consumption < 2mA
Detection Accuracy ± 1%
Scan Speed 1 scan/500ms
Display Type Color LCD (wide viewing angle)
Alarm Reminder Built-in flashing light, audible alarm
Power Supply DC
DIY Supplies Electrical
Battery Included No

Product Dimensions:

  • Waterproof Model: 68.5mm * 38.5mm * 14.1mm
  • Non-Waterproof Model: 73.78mm * 43.8mm * 14mm
  • Non-Waterproof Model Opening Size: 68.78mm * 38.8mm
Dimensional drawing of the 6839C Electricity Meter showing length 68.78mm, width 38.8mm, and thickness 14.3mm.

Figure 3: Dimensions of the 6839C Electricity Meter.

3. Setup and Installation

The 6839C Electricity Meter is designed for straightforward installation. It comes with pre-attached wiring for connection to your battery system. Ensure proper polarity when connecting the wires (typically red for positive, black for negative).

Image of the electricity meter with red and black wires for connection.

Figure 4: The electricity meter with its connection wires.

Mounting Options:

The meter can be installed directly into a panel opening or mounted using an optional bracket (for models that support it).

  • Panel Mount: For non-waterproof models, ensure the opening size is 68.78mm x 38.8mm.
  • Bracket Mount: Secure the bracket to a suitable surface, then attach the meter to the bracket.
Electricity meter shown with an optional mounting bracket.

Figure 5: Electricity meter with an optional bracket for mounting.

Important: Always disconnect power before installation to prevent electrical shock or damage to the device.

4. Operating Instructions

Basic Operation:

  • On the home page, short-press the power button to turn the display on and off.

Entering Setup Mode:

  • Press and hold the SET button for 2 seconds to enter setup mode.

Mode Setting Instructions:

Once in setup mode, short-press the button to cycle through different setting menus. Press and hold the button for 2 seconds to enter a specific setting, then short-press to adjust values, and press and hold again to confirm.

4.1. Ternary Lithium Battery Settings (Menu L):

  1. From the main page, press and hold the button for 2 seconds to enter settings. "L-003" will be displayed.
  2. On the "L-003" page, press and hold the button for 2 seconds; the value "03" will flash.
  3. Short-press the button to select the number of battery strings (from 03 to 22 strings).
  4. Press and hold the button for 2 seconds to confirm (the value will become solid).
  5. Press and hold the button for 2 seconds again to return to the main page, or short-press to go to the next settings page.
Display showing 'L-003' for ternary lithium battery settings.

Figure 6: Ternary Lithium Battery Setting Display.

4.2. Iron-Lithium Battery Settings (Menu F):

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the "F-003" page.
  2. On the "F-003" page, press and hold the button for 2 seconds; the value "03" will flash.
  3. Short-press the button to select the number of battery strings (from 03 to 26 strings).
  4. Press and hold the button for 2 seconds to confirm (the value will become solid).
  5. Press and hold the button for 2 seconds again to return to the main page, or short-press to go to the next settings page.
Display showing 'F-003' for iron-lithium battery settings.

Figure 7: Iron-Lithium Battery Setting Display.

4.3. Lead-Acid Battery Settings (Menu P):

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the "P-12" page.
  2. On the "P-12" page, press and hold the button for 2 seconds; the value "12" will flash.
  3. Short-press the button to select the battery voltage (12V/24V/36V/48V/60V/72V/84V).
  4. Press and hold the button for 2 seconds to confirm (the value will become solid).
  5. Press and hold the button for 2 seconds again to return to the main page, or short-press to go to the next settings page.
Display showing 'P-12' for lead-acid battery settings.

Figure 8: Lead-Acid Battery Setting Display.

4.4. Custom Voltage Settings (Menu C):

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the custom voltage setting page (e.g., "VOL: 88.8V C- 88.8"). The first row is high voltage, the second is low voltage.
  2. Press and hold the button for 2 seconds; the first value will flash. Short-press to select the desired value.
  3. Press and hold the button for 2 seconds again; the first value will become solid, and the second value will flash. Short-press to select the desired value.
  4. After setting both values, short-press to enter the second row of settings. Repeat the process for the second row.
  5. After all values are set, press and hold the button for 2 seconds to return to the main page, or short-press to go to the next settings page.
Display showing 'VOL: 88.8V C- 88.8' for custom voltage settings.

Figure 9: Custom Voltage Setting Display.

4.5. Backlight Settings (Menu BL):

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the "BL" page.
  2. On the "BL" page, press and hold the button for 2 seconds; "00" will flash.
  3. Short-press the button to select backlight duration (00 for always on, or 10/20/30/40/50/60/70/80/90 seconds).
  4. Press and hold the button for 2 seconds to confirm (the value will become solid).
  5. Press and hold the button for 2 seconds again to return to the main page, or short-press to go to the next settings page.
Display showing '00 BL' for backlight settings.

Figure 10: Backlight Setting Display.

4.6. High and Low Pressure Alarm Settings (Menu AL):

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the high and low pressure alarm settings page (e.g., "VOL: 188.8V AL 88.8"). The first line is high pressure, the second is low pressure.
  2. Press and hold the button for 2 seconds; the first value will flash. Short-press to select the desired value.
  3. Press and hold the button for 2 seconds again; the first digit will become solid, and the second digit will flash. Short-press to select the desired value.
  4. After all three values are set, short-press to enter the second line of settings. Repeat the process for the second line.
  5. After all values are set, press and hold the button for 2 seconds to return to the main page, or short-press to go to the next settings page.
Display showing 'VOL: 188.8V AL 88.8' for high and low pressure alarm settings.

Figure 11: High and Low Pressure Alarm Setting Display.

Image illustrating overcharge and overdischarge alarm reminders, showing battery capacity higher than 100% and lower than 10% with warnings.

Figure 12: Voltage alarm reminder functionality.

4.7. Voltage Calibration Setting (Menu CL) - Manufacturer Only:

Warning: This function is for manufacturer use only. Unauthorized operation will affect voltage accuracy.

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the electronic calibration function page ("CL").
  2. On the "CL" page, press and hold the button for 2 seconds; the displayed voltage will flash.
  3. Press and hold the button for 2 seconds again to complete automatic calibration and return to the main page.
Display showing 'VOL: 188.8V CL' for voltage calibration settings.

Figure 13: Voltage Calibration Setting Display.

4.8. SOC Mode Setting (Menu SO) - Manufacturer Only:

Warning: This function is for manufacturer use only. Users cannot set this function; please contact the manufacturer.

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to switch to the SOC settings page ("SO").
  2. On the "SO" page, press and hold the button for 2 seconds. Select "ON" or "OF" on the right.
  3. Press and hold the button for 2 seconds to confirm.
  4. Press and hold the button for 2 seconds again to return to the main page, or short-press to go to the next settings page.
Display showing 'OF SO' and 'ON SO' for SOC mode settings.

Figure 14: SOC Mode Setting Display.

4.9. Restore Factory Settings (Menu RF) - Caution Advised:

Warning: Non-professionals should not use this function, otherwise it will affect the use of the product.

  1. From the main page, press and hold the button for 2 seconds to enter settings. Short-press to select the factory reset page ("RF").
  2. On the "RF" page, press and hold the button for 2 seconds. The three "8"s on the left will flash, then turn into three "0"s.
  3. Press and hold the button for 2 seconds to restore factory settings. The three "0"s will light up steadily, indicating completion.
  4. Press and hold the button for 2 seconds again to return to the main page, or short-press to go to the next settings page.
Display showing '1888 RF' for factory reset settings.

Figure 15: Factory Reset Setting Display.

5. Maintenance

  • Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
  • Ensure all connections are secure and free from corrosion.
  • The device features a built-in storage chip for power-off memory, so no special maintenance is required for data retention.

6. Troubleshooting

Common Issues and Solutions:

  • No Display/Power:
    • Check power connections to ensure they are secure and correctly polarized.
    • Verify that the input voltage is within the DC 8-100V range.
  • Inaccurate Readings:
    • Ensure the correct battery type and string count (or voltage for lead-acid) are configured in the settings.
    • If the issue persists, and you are a professional, consider using the voltage calibration function (Menu CL) with caution, or contact the manufacturer.
  • Alarm Triggering Unexpectedly:
    • Review the High and Low Pressure Alarm Settings (Menu AL) to ensure thresholds are set appropriately for your battery system.
  • Display Not Turning Off:
    • Check Backlight Settings (Menu BL). If set to "00", the backlight will always be on. Adjust to a timed setting if desired.
Image depicting common issues like RV power outage, uncertainty about battery charge, and inaccurate measurements, which this meter helps resolve.

Figure 16: The meter helps resolve common power monitoring issues.

7. User Tips

  • For optimal accuracy, ensure your battery type and configuration (number of strings or voltage) are correctly set in the meter's settings.
  • Utilize the voltage alarm reminder feature to proactively monitor battery health and prevent overcharge or overdischarge, extending battery lifespan.
  • The wide viewing angle display makes it easy to read from various positions, useful in diverse installation scenarios like RVs or electric vehicles.

8. Warranty and Support

This product is covered by a standard manufacturer's warranty. For warranty claims, technical support, or inquiries regarding advanced functions like Voltage Calibration (Menu CL) or SOC Mode Setting (Menu SO), please contact the manufacturer or your point of purchase. Do not attempt unauthorized repairs or modifications, especially for calibration functions, as this may void your warranty and affect product performance.

For further assistance, you may refer to the official product page or contact the seller directly.

A PDF version of the user manual is available for download: User Manual (PDF)

© 2024 TEKIVI. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.