1. Introduction
The TOOLTOP OS-5C is a versatile five-channel digital oscilloscope designed for a wide range of electrical measurement and analysis tasks. Featuring a 1MHz bandwidth and a 3Ms/s sampling rate, it provides accurate waveform visualization on its 4.3-inch IPS screen. This device supports both USB and optional Wi-Fi connectivity for data recording and analysis via PC software or mobile applications, making it suitable for R&D, teaching, and field troubleshooting.

2. Setup
2.1 Unpacking and Inspection
Carefully unpack the oscilloscope and all accessories. Verify that all components are present and undamaged. If any items are missing or damaged, please contact your vendor.
2.2 Powering On/Off
To power on the device, press and hold the ON-OFF button located on the front panel. To power off, press and hold the same button until the device shuts down.
2.3 Probe Connection
Connect the oscilloscope probes to the CH1 through CH5 input channels as required for your measurements. Ensure a secure connection for accurate readings.

2.4 Connectivity (USB & Wi-Fi)
The OS-5C supports dual-mode operation via USB and optional Wi-Fi. For wired connection, use the USB Type-C port to connect the oscilloscope to a computer. For wireless operation, ensure you have the Wi-Fi version and follow the instructions for connecting to a mobile app or PC software.

3. Operating Instructions
3.1 User Interface and Controls
The oscilloscope features a 4.3-inch IPS display and a set of physical buttons for navigation and function control.

- ON-OFF Button: Powers the device on or off.
- Function Buttons (F1-F4): These buttons perform various context-sensitive functions, typically displayed on the screen.
- Navigation Buttons (Up, Down, Left, Right, Enter, Back): Used to navigate menus, adjust parameters, and select options.
- USB Port: For data transfer and power.
- RESET Button: Resets the device to its default state.
3.2 Display Modes
The OS-5C supports multiple waveform display modes:
- YT Mode: Standard time-domain display, showing voltage (Y-axis) against time (T-axis).
- XY Mode: Displays the relationship between two signals, often used for phase comparison or Lissajous figures.
- ROLL Mode: A continuous scrolling display, useful for observing slow-changing signals.

3.3 Parameter Measurements
The oscilloscope can automatically calculate and display up to 10 parameters, including:
- Frequency (FREQ)
- Peak-to-peak voltage (Vp-p)
- Average voltage (AVG)
- Root Mean Square (RMS)
- Duty Cycle (DUTY)
- Maximum voltage (MAX)
- Minimum voltage (MIN)
- Amplitude (AMP)
- Pulse Width (PW)
- Period
3.4 Data Recording and Analysis
The OS-5C offers 8M x 5 channel data storage, allowing for waveform data recording for up to 90 hours. This data can be transferred to a computer for in-depth analysis using dedicated PC software.

3.5 Low-frequency Signal Analysis
The device is capable of analyzing low-frequency signals, such as those from audio circuits and sensors, with a maximum sampling rate of 3MHz.

4. Maintenance
4.1 Cleaning
To clean the oscilloscope, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device. Do not use abrasive cleaners or solvents.
4.2 Battery Care
The OS-5C uses a removable 3.7V/18650 / 2000mAh battery. While the battery is removable, it may not be included with all models. If your model includes a battery, ensure it is charged regularly, especially if the device will be stored for extended periods. Avoid extreme temperatures during charging and storage to prolong battery life.
4.3 Storage
Store the oscilloscope in a cool, dry place away from direct sunlight, dust, and excessive humidity. When not in use for long periods, it is advisable to remove the battery if possible.
5. Troubleshooting
This section provides solutions to common issues you might encounter.
- No Power/Display:
- Ensure the device is fully charged or connected to a stable 5V USB power source.
- Press and hold the ON-OFF button for a few seconds to ensure it's properly turning on. - No Signal Displayed:
- Verify that the probes are correctly connected to both the oscilloscope and the circuit under test.
- Check the signal source to ensure it is active and within the oscilloscope's measurement range.
- Adjust the vertical (voltage) and horizontal (time) scales to properly capture the signal. - Incorrect or Unstable Readings:
- Ensure probes are properly calibrated (if applicable).
- Check for loose connections or damaged probes.
- Verify that the AC/DC coupling setting is appropriate for the signal being measured.
- Adjust the trigger settings to stabilize the waveform. - Connectivity Issues (USB/Wi-Fi):
- For USB, ensure the cable is securely connected and the correct drivers are installed on your computer.
- For Wi-Fi, ensure the oscilloscope's Wi-Fi module is enabled and correctly configured to connect to your network or device. Check firewall settings on your computer/mobile device.
6. Specifications
The following table details the technical specifications of the TOOLTOP OS-5C Oscilloscope:

| Feature | Specification |
|---|---|
| Brand Name | TOOLTOP |
| Model | OS-5C |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Screen | 4.3 inch IPS 480*272 |
| Channel Number | 5 |
| Maximum Sampling Rate | 3MHz*3 / 1.5MHz*4 / 1.5MHz*5 |
| Bandwidth | 1MHz |
| Input Impedance | 1 MΩ/20pF |
| AC/DC Selection | AC / DC |
| Maximum Measured Voltage | ±10V (X10: ±100V) |
| Maximum Peak-to-Peak Voltage | 20V (X10: 200V) |
| Voltage Range (PC software/Mobile APP) | 2mV/div - 2V/div |
| Voltage Range (Screen) | 4mV/div - 4V/div |
| Time Base Range (PC software/Mobile APP) | 1uS/div - 1000S/div |
| Time Base Range (Screen) | 1uS/div - 4S/div |
| Depth of Data Recording (PC software) | 8M *5CH / Up to 90 hours |
| Waveform Display Mode | YT / XY / ROLL |
| Vertical Resolution | 8 bit |
| Trigger Type | Rising Edge / Falling Edge |
| Data Show | Period, Duty, Frequency, Vp-p, Maximum, Minimum, Average, Amplitude, Duty Cycle, Pulse Width |
| Language | English / PRC / Portugues / Espano |
| Port Type | USB Type-C |
| Operating Voltage | 5V |
| Current Consumption | <2A |
| Battery Specifications | 3.7V/18650 / 2000mAh / Removable |
| Battery Standby Time | <3 hours |
| Signal Output | 1KHz |
| Radio Frequency (Optional WiFi version required) | Wi-Fi 2.4G or 5G |
| Main Unit Size | 150mm * 100mm * 32mm |
| Net Weight | 350g |
| High-concerned chemical | None |
7. User Tips
- For long-term data acquisition and detailed analysis, utilize the PC software to leverage the 90-hour recording capability.
- If you have the Wi-Fi enabled version, explore the mobile application for remote monitoring and control, enhancing flexibility in various testing environments.
- Always ensure your probes are correctly compensated for accurate measurements, especially when dealing with high-frequency signals.
8. Warranty and Support
The TOOLTOP OS-5C Oscilloscope is manufactured to high standards. For any technical assistance, warranty claims, or support inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase. Please note that some sellers may offer free returns within 90 days; check with your specific vendor for details on their return policy.