TSUN MA06LS

TSUN MA06LS Digital Magnetic Grid Ruler Instruction Manual

Model: MA06LS | Brand: TSUN

1. Introduction

The TSUN MA06LS is an integrated magnetic grid ruler digital display meter designed for precise digital positioning and measurement. Its miniature electronic ruler capabilities make it suitable for various applications, particularly in electrical DIY projects where accurate positioning is crucial. This manual provides detailed instructions for the proper setup, operation, and maintenance of your MA06LS unit.

2. Key Features

3. Specifications

General Specifications
Attribute Value
Model MA06LS
DIY Supplies Category Electrical
Origin Mainland China
High-concerned chemical None
Certification None
Package Information
Attribute Value
Package Length 22 cm
Package Width 22 cm
Package Height 11 cm
Package Weight 5.0 kg

4. Package Contents

The package typically includes:

TSUN MA06LS Digital Display Meter

Figure 4.1: TSUN MA06LS Digital Display Meter with integrated sensor.

5. Setup and Installation

The TSUN MA06LS is designed for easy integration into various machinery and setups. Follow these steps for proper installation:

  1. Mounting the Display Unit: Securely mount the MA06LS digital display unit to a stable surface using appropriate fasteners. Ensure the display is easily visible and accessible for operation. The miniature design allows for installation in tight spaces.
  2. Positioning the Magnetic Grid Ruler: The magnetic grid ruler sensor is integrated with the display unit. Position the sensor along the linear path where measurements are required. Ensure the sensor is parallel to the movement axis and maintains a consistent, small gap from the magnetic strip (not explicitly shown but implied by "magnetic grid ruler").
  3. Connecting Power: Connect the power supply to the MA06LS unit. Refer to the device's power input specifications (not provided in JSON, so keep general).
  4. Initial Power-On: Once mounted and powered, the unit should display a reading. If an error code like "E07" appears, refer to the troubleshooting section.
TSUN MA06LS mounted on a linear guide

Figure 5.1: Example installation of the MA06LS on a linear measurement setup.

6. Operation

The MA06LS features a simple four-button interface for operation:

Close-up of TSUN MA06L digital display with buttons

Figure 6.1: Front view of the digital display with control buttons.

6.1 Basic Measurement

  1. Ensure the unit is powered on and displaying a reading.
  2. Move the magnetic grid ruler sensor along the desired path. The display will show the real-time position.
  3. To set a new zero point, press the 'C' (F4) button. The display will reset to 0.00.
  4. Use the arrow buttons (F2, F3) to adjust settings or change measurement direction if needed (e.g., for incremental vs. absolute measurements, if supported).

6.2 Demonstration Video

Video 6.1: Demonstration of the digital display changing values during operation.

7. Maintenance

To ensure the longevity and accuracy of your TSUN MA06LS digital display meter, follow these maintenance guidelines:

8. Troubleshooting

If you encounter issues with your MA06LS unit, refer to the following common problems and solutions:

Problem Possible Cause Solution
Display shows "E07" This error code often indicates an issue with the sensor connection or signal. Check the connection between the sensor and the display unit. Ensure the sensor is properly aligned with the magnetic strip and the gap is within the recommended range. Power cycle the device.
Inaccurate readings Sensor misalignment, debris on the magnetic strip, or external magnetic interference. Verify sensor alignment and distance from the magnetic strip. Clean the magnetic strip and sensor head. Ensure no strong magnets are near the measurement area.
Display is blank No power or faulty connection. Check the power supply and ensure all connections are secure. Test the power outlet.
TSUN MA06LS digital display showing E07 error

Figure 8.1: The MA06LS display showing an "E07" error code.

9. Warranty and Support

For warranty information or technical support, please contact the seller directly using the information below:

Please provide your product model (MA06LS) and a detailed description of the issue when contacting support.

Related Documents - MA06LS

Preview TSUN MS800/MS2000 App Einrichtung
Eine detaillierte Schritt-für-Schritt-Anleitung zur Einrichtung der TSUN MS800/MS2000 Wechselrichter-App. Enthält Anleitungen zur Installation der 'Talent Home' oder 'TSUN Smart' App, Konfiguration der Anlage, Netzwerkeinstellungen und Fehlerbehebung für eine optimale Nutzung.
Preview TSUN Smart App: Professional Installer and Residential Microinverter System Setup Guide
A comprehensive guide for professional installers and residential users on setting up the TSUN Smart App for microinverter systems. Covers plant creation, datalogger connection, WiFi configuration, and anti-reverse flow settings.
Preview TSUN Smart App: Quick Installation Guide for End-Users and Installers
A concise guide to installing and configuring the TSUN Smart app for both end-users and distributors/installers. Covers account registration, device addition, and Wi-Fi configuration for seamless solar energy monitoring.
Preview TSUN Microinverter User Manual: TSOL-MP3000, TSOL-MP2250, TSOL-MS3000
Comprehensive user manual for TSUN microinverters, covering installation, operation, maintenance, and troubleshooting for models TSOL-MP3000, TSOL-MP2250, and TSOL-MS3000. Learn about safety precautions, product specifications, and warranty information.
Preview TSUN SolarTrunk/PowerTrunk Quick Installation and App Guide
Comprehensive guide for installing and setting up TSUN SolarTrunk and PowerTrunk energy storage systems, including detailed instructions for the TSUN Smart mobile application.
Preview TSUN DCU1000 & P1000 Quick Installation Guide
Comprehensive quick installation guide for TSUN DCU1000 and P1000 portable power stations, covering setup, connections, status indicators, and safety precautions.