1. Introduction
The TSUN MA06LS is an integrated magnetic grid ruler digital display meter designed for precise digital positioning and measurement. Its miniature electronic ruler capabilities make it suitable for various applications, particularly in electrical DIY projects where accurate positioning is crucial. This manual provides detailed instructions for the proper setup, operation, and maintenance of your MA06LS unit.
2. Key Features
- Integrated magnetic grid ruler for high precision.
- Digital display for clear and easy-to-read measurements.
- Miniature design, ideal for installations in confined spaces.
- User-friendly interface with four control buttons (P/F1, Up/F2, Right/F3, C/F4).
- Suitable for various electrical DIY applications requiring accurate positioning.
3. Specifications
| Attribute | Value |
|---|---|
| Model | MA06LS |
| DIY Supplies Category | Electrical |
| Origin | Mainland China |
| High-concerned chemical | None |
| Certification | None |
| Attribute | Value |
|---|---|
| Package Length | 22 cm |
| Package Width | 22 cm |
| Package Height | 11 cm |
| Package Weight | 5.0 kg |
4. Package Contents
The package typically includes:
- TSUN MA06LS Digital Display Meter
- Integrated Magnetic Grid Ruler Sensor (attached)
- Connecting Cable
Figure 4.1: TSUN MA06LS Digital Display Meter with integrated sensor.
5. Setup and Installation
The TSUN MA06LS is designed for easy integration into various machinery and setups. Follow these steps for proper installation:
- Mounting the Display Unit: Securely mount the MA06LS digital display unit to a stable surface using appropriate fasteners. Ensure the display is easily visible and accessible for operation. The miniature design allows for installation in tight spaces.
- Positioning the Magnetic Grid Ruler: The magnetic grid ruler sensor is integrated with the display unit. Position the sensor along the linear path where measurements are required. Ensure the sensor is parallel to the movement axis and maintains a consistent, small gap from the magnetic strip (not explicitly shown but implied by "magnetic grid ruler").
- Connecting Power: Connect the power supply to the MA06LS unit. Refer to the device's power input specifications (not provided in JSON, so keep general).
- Initial Power-On: Once mounted and powered, the unit should display a reading. If an error code like "E07" appears, refer to the troubleshooting section.
Figure 5.1: Example installation of the MA06LS on a linear measurement setup.
6. Operation
The MA06LS features a simple four-button interface for operation:
Figure 6.1: Front view of the digital display with control buttons.
- P (F1) Button: Typically used for setting parameters or entering/exiting menu modes.
- Up Arrow (F2) Button: Used to increment values, navigate menus upwards, or change measurement direction.
- Right Arrow (F3) Button: Used to shift digits, navigate menus rightwards, or confirm selections.
- C (F4) Button: Used to clear the current reading, reset to zero, or cancel an operation.
6.1 Basic Measurement
- Ensure the unit is powered on and displaying a reading.
- Move the magnetic grid ruler sensor along the desired path. The display will show the real-time position.
- To set a new zero point, press the 'C' (F4) button. The display will reset to 0.00.
- Use the arrow buttons (F2, F3) to adjust settings or change measurement direction if needed (e.g., for incremental vs. absolute measurements, if supported).
6.2 Demonstration Video
Video 6.1: Demonstration of the digital display changing values during operation.
7. Maintenance
To ensure the longevity and accuracy of your TSUN MA06LS digital display meter, follow these maintenance guidelines:
- Cleaning: Gently wipe the display and sensor surfaces with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the components.
- Environmental Conditions: Operate and store the device in a clean, dry environment, away from excessive dust, moisture, and extreme temperatures.
- Magnetic Interference: Keep the unit away from strong magnetic fields that could interfere with the magnetic grid ruler's accuracy.
- Cable Inspection: Periodically check the connecting cable for any signs of wear, cuts, or damage. Replace if necessary.
8. Troubleshooting
If you encounter issues with your MA06LS unit, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display shows "E07" | This error code often indicates an issue with the sensor connection or signal. | Check the connection between the sensor and the display unit. Ensure the sensor is properly aligned with the magnetic strip and the gap is within the recommended range. Power cycle the device. |
| Inaccurate readings | Sensor misalignment, debris on the magnetic strip, or external magnetic interference. | Verify sensor alignment and distance from the magnetic strip. Clean the magnetic strip and sensor head. Ensure no strong magnets are near the measurement area. |
| Display is blank | No power or faulty connection. | Check the power supply and ensure all connections are secure. Test the power outlet. |
Figure 8.1: The MA06LS display showing an "E07" error code.
9. Warranty and Support
For warranty information or technical support, please contact the seller directly using the information below:
- Email: 19015061212@163.com
- WhatsApp: +86 17775906001
Please provide your product model (MA06LS) and a detailed description of the issue when contacting support.