1. Product Overview
The JIKONG Smart Active Balance BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It integrates advanced features to ensure optimal performance, longevity, and safety of your battery system.
1.1. BMS Overview
This intelligent protection board is tailored for large capacity series lithium battery packs, offering comprehensive management. Key functionalities include voltage acquisition, high current active balancing, overcharge/over-discharge protection, over-current protection, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote functionality. It is compatible with various battery chemistries, including Lithium Iron Phosphate (LiFePO4), Ternary Lithium, and Lithium Titanate (LTO) battery types.
The protection board utilizes energy transfer active balancing technology with proprietary intellectual property rights, achieving a maximum continuous 2A balance current. This high-current active equalization technology significantly enhances battery consistency, extends battery range, and delays battery aging.
A mobile application (APP) is available for both Android and iOS operating systems. This APP connects to the BMS via Bluetooth, allowing users to monitor the battery's working status, modify protection parameters, and control charge/discharge switches. The compact design, ease of operation, and comprehensive features make this BMS suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support CAN communication
- Support RS485 communication
- Support heating function
- Support GPS interface
- Support alarm and fan control functions
- Discharge precharge function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Force on discharge function
- Charge current limiting function
3. Structural Block Diagram
The following diagram illustrates the internal structure and interconnections of the JIKONG Active Balancing Protection Board.

The diagram shows key components such as the MCU (Microcontroller Unit), MOS driver circuit, active balancing module, power module, and various interfaces for communication (RS485, CAN), display, GPS, heating, alarm, and NTC temperature sensors.
4. Specifications
4.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 12-40 | V |
| Operating Power Consumption | 1000-1400 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 8 | S |
| Max. Balancing Current | 2 | A |
| Max. Charging Current | 200 | A |
| Max. Discharge Current | 200 | A |
| Max. Instantaneous Current | 400 | A |
| Max. Starting Current | 3000 | A |
| Max. Internal Loop Resistance | 0.3 | mΩ |
| Protective Plate Size | 227*120*23.12 | mm |
| Finished Weight | 620 | g |
4.2. Default Parameters
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Max. Balancing Current | 2 | 2 | 2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 1500 | 1500 | 1500 | uS |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charging Overtemperature Recovery | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charging Low Temperature Recovery | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
| Discharge Precharge Time | 0 | 0 | 0 | S |
5. Setup and Installation
5.1. Product Appearance and Dimensions
The JK-QB2A8S-20P protection board has dimensions of 227mm × 120mm × 23.12mm.

5.2. Interface Definition
The BMS features various connectors and interfaces for different functions. Refer to the following table for a detailed breakdown of each pin and its definition.

| Connector | Interface Name | Pin Number | Pin Name | Definition |
|---|---|---|---|---|
| P1 (XH2.0-9P) | Balance with Acquisition Interface | 1 | B- | Total Negative Battery |
| 2 | B1 | 1st Battery Positive | ||
| 3 | B2 | 2nd Battery Positive | ||
| 4 | B3 | 3rd Battery Positive | ||
| 5 | B4 | 4th Battery Positive | ||
| 6 | B5 | 5th Battery Positive | ||
| 7 | B6 | 6th Battery Positive | ||
| 8 | B7 | 7th Battery Positive | ||
| 9 | B8 | 8th Battery Positive | ||
| P2 (XH2.0-4P) | Temperature Interface | 1 | T1A | 1st Temperature Sensor Pin A |
| 2 | T1B | 1st Temperature Sensor Pin B | ||
| 3 | T2A | 2nd Temperature Sensor Pin A | ||
| 4 | T2B | 2nd Temperature Sensor Pin B | ||
| P3 (XH2.0-4P) | Temperature Interface | 1 | T3A | 3rd Temperature Sensor Pin A |
| 2 | T3B | 3rd Temperature Sensor Pin B | ||
| 3 | T4A | 4th Temperature Sensor Pin A | ||
| 4 | T4B | 4th Temperature Sensor Pin B | ||
| P5 (A1254WF-4A) | Force Start Discharge Switch | 1 | LED- | LED Indicator Negative |
| 2 | LED+ | LED Indicator Positive | ||
| 3 | K- | Key Switch Negative | ||
| 4 | K+ | Key Switch Positive | ||
| P5 (A1254WF-4A) | Force Start Heating Switch | 1 | LED- | LED Indicator Negative |
| 2 | LED+ | LED Indicator Positive | ||
| 3 | K- | Key Switch Negative | ||
| 4 | K+ | Key Switch Positive | ||
| P6 (A1254WF-4A) | Communication Interface | 1 | RS485-B | RS485-B |
| 2 | RS485-A | RS485-A | ||
| 3 | CAN-H | CAN-H | ||
| 4 | CAN-L | CAN-L | ||
| P7 (A1254WF-6A) | Display Interface | 1 | VCC | Display Power Output |
| 2 | A | Display RS485 Signal Positive | ||
| 3 | B | Display RS485 Signal Negative | ||
| 4 | GND | Negative Terminal | ||
| 5 | K+ | Activate Positive Signal | ||
| 6 | K- | Activation Negative Electrode | ||
| P8 (1.25T-4PWT) | GPS Interface | 1 | VGPS | Power Output (Voltage close to B+) |
| 2 | TX | UART TX, 3.3V | ||
| P9 (A1254WF-2A) | Alarm Interface | 1 | V+ | Alarm Power Output 12V Positive |
| 2 | V- | Alarm Power Output 12V Negative Electrode | ||
| P10 (M3-PCB) | Heating Interface | 1 | HT- | Heater Element Negative Electrode |
| P11 (M3-PCB) | Power Input | 1 | B+ | Power Input Positive |
| D1 (Bluetooth connection indicator): When the Bluetooth is connected to the protection board, the indicator is steady on, and when the connection is disconnected, the indicator is blinking. | ||||
| P-: Connect to external load or negative terminal of charger | ||||
| B-: Connect to the negative battery terminal | ||||
5.3. Installation Method
The JK-QB2A8S-20P series protection board is suitable for 3-8 series lithium battery packs. The wiring method varies depending on the number of cells in the battery pack. Always ensure correct wiring to prevent damage.

Wiring Steps:
- Balance Cables: Connect the balance cables from the battery cells to the P1 connector (XH2.0-9P) on the BMS. Ensure each cell's positive terminal is connected to the corresponding Bx pin, and the total negative is connected to B-.
- Main Power Cables: Connect the main negative terminal of the battery pack to B- on the BMS. Connect the main positive terminal of the battery pack to P11 (B+) on the BMS.
- Load/Charger Connection: Connect the external load or negative terminal of the charger to P- on the BMS.
- Temperature Sensors: Connect NTC temperature sensors to P2 and P3 (XH2.0-4P) interfaces as needed. The BMS supports 1 built-in and 4 external NTC sensors.
- Optional Connections:
- Display: If using an optional display, connect it to the P7 (A1254WF-6A) interface.
- GPS: If using an optional GPS module, connect it to the P8 (1.25T-4PWT) interface.
- Alarm: Connect an alarm device to the P9 (A1254WF-2A) interface.
- Heating: Connect a heating element to the P10 (M3-PCB) interface.
- Communication: Connect CAN or RS485 communication devices to the P6 (A1254WF-4A) interface.
- Force Start Switches: Connect force start discharge/heating switches to the respective P5 (A1254WF-4A) interfaces.
Important: Before powering on the protection board, double-check all balance cable connections and ensure P- and B+ are correctly connected. Verify that the protection board is securely fixed to the battery pack. Incorrect wiring can lead to abnormal operation or damage.
6. Operating Instructions
6.1. Device Activation
The BMS does not have a physical power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage to activate it after battery assembly. Alternatively, the device can be activated via a button (if equipped) or through the display interface (if connected).
6.2. APP Operation Instructions
The JIKONG BMS features a mobile APP for both Android and iOS devices, allowing for comprehensive monitoring and parameter configuration.
6.2.1. APP Installation
To install the mobile APP, scan the QR code provided below. The Android APP requires a minimum of Android 7.

6.2.2. Parameter Setting
After connecting to the BMS via Bluetooth through the APP, users can access the parameter settings page. Here, you can configure various operational parameters, including:
- Battery type (Li-ion, LiFePO4, LTO)
- Number of cells
- Battery capacity
- Trigger equalization differential pressure
- Voltage and current calibration
- Protection thresholds (overcharge, undervoltage, overcurrent, overtemperature, low temperature)
- Short circuit protection delay and recovery time
- Discharge precharge function settings
- Intelligent sleep mode activation
Refer to the 'Instructions for Setting Protection Board Parameters' document for detailed guidance on each parameter.
6.3. Active Equalization
The BMS employs active equalization to transfer energy from higher voltage cells to lower voltage cells, maintaining cell consistency. Before using, set basic battery parameters in the APP. The default balance current is 2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. The equalization function can be toggled on/off via the APP.

6.4. Heating Function
The optional heating function uses a resistance heater or film to warm the battery at low temperatures, preventing reduced activity and charging/discharging issues. The designed heating current is 4A. Users can control this function via the APP. It is recommended to install a normally closed temperature switch (45-65°C) in series with the heating circuit for secondary protection. The BMS also features a forced start heating function, activated by an external switch, for use when external conditions don't meet automatic heating triggers.6.5. Alarm and Fan Control Functions
The BMS includes standard alarm and fan control. When the BMS detects conditions like overtemperature, overcharge, or over-discharge, the alarm interface outputs 12V to trigger an alarm or activate a cooling fan. Only one triggering condition can be selected at a time, configurable via the APP.6.6. Communication Function
The BMS supports CAN and RS485 communication. Users can configure the address and communication protocol via the APP based on their specific requirements and scenarios. Refer to the Jikong Protection Board communication protocol document for details.6.7. Charge Current Limiting Function
This function is standard. When the battery experiences charging overcurrent, the current limiting function activates, maintaining the charging current at approximately 10A to protect the battery. This also triggers under low-temperature charging conditions to protect the battery.
7. Protection Functions
The JIKONG BMS is equipped with multiple protection mechanisms to ensure the safety and longevity of your battery pack.
7.1. Overcharge Protection and Recovery
The BMS provides standard overcharge protection. Users can set the single overcharge protection voltage and recovery voltage via the APP. If any battery string exceeds the set overcharge voltage during charging, the BMS will stop charging to prevent damage. Charging resumes when all cells fall below the recovery voltage.7.2. Discharge Undervoltage Protection and Recovery
Standard discharge undervoltage protection is included. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage via the APP. If any cell's voltage drops below the set undervoltage protection during discharge, the BMS will stop discharging. Discharge resumes when all cells are charged above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down to protect the battery.7.3. Charge Overcurrent Protection and Recovery
Standard charge overcurrent protection is provided. Users can set the continuous charging current, overcurrent delay, and release time via the APP. If the charging current exceeds the set limit for the specified delay, charging will stop. Charging resumes after the set release time.7.4. Discharge Overcurrent Protection and Recovery
Standard discharge overcurrent protection is included. Users can set the continuous discharge current, overcurrent delay, and release time via the APP. If the discharge current exceeds the set limit for the specified delay, discharging will stop. Discharging resumes after the set release time. Note: The maximum continuous discharge current should not exceed 200A.7.5. Overtemperature Protection and Recovery
The BMS offers standard charge and discharge overtemperature protection. Users can set the protection and recovery temperatures for both charging and discharging via the APP. If the temperature exceeds the set limit, the BMS will stop the respective operation (charging or discharging). The operation resumes when the temperature drops below the recovery threshold.7.6. Low Temperature Protection and Recovery
Standard charging low temperature protection is included. Users can set the protection and recovery temperatures via the APP. If the temperature drops below the set limit, charging will stop. Charging resumes when the temperature rises above the recovery threshold. For extremely cold environments, using the heating function is recommended.7.7. Short Circuit Protection and Recovery
The BMS is equipped with standard short circuit protection. Users can adjust the short circuit protection delay (in microseconds) and recovery time (in seconds) via the APP. If a short circuit is detected, the BMS will stop the operation. The protection is released after the recovery time. If charging short circuit protection is triggered upon first connection, increasing the delay may resolve issues caused by high peak currents from the charger. Similarly, for discharge short circuit protection, increasing the delay can help with loads that have large internal capacitance.7.8. Discharge Precharge Function
The optional discharge precharge function has a default precharge time of 5 seconds. Users can enable or disable this function via the APP. Setting the precharge time to 0 disables the function.7.9. Emergency Switch
The BMS includes a standard emergency switch function. If issues like overtemperature, over-discharge, overcharge, or cell drop occur during normal use, activating the emergency switch via the APP will enable both charging and discharging for 30 minutes. This provides a temporary operational window, even if a single cell reaches the automatic shutdown voltage, to prevent critical situations.7.10. Intelligent Sleep
The BMS features an intelligent sleep function, which can be enabled or disabled via the APP. Its purpose is to shut down the protection board when it's in standby (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated by pressing a button or connecting a charger.
8. Maintenance
The JIKONG BMS is designed for durability and reliability. Regular maintenance is generally not required beyond ensuring clean connections and proper ventilation for optimal heat dissipation. Periodically check for any loose wiring or signs of physical damage. Keep the firmware updated via the mobile APP for the latest features and improvements.
9. Troubleshooting
Most issues can be resolved by checking connections and APP settings. Refer to the specific protection functions in Section 7 for details on how the BMS reacts to various conditions.
- BMS Not Activating: Ensure all balance cables are correctly connected, and the main power connections (P- and B+) are secure. Activate the BMS by connecting a charger with a voltage 2V higher than the battery pack, or by using the optional button/display.
- Unexpected Shutdown/Protection Trigger: Check the APP for active protection alerts (e.g., overvoltage, undervoltage, overcurrent, overtemperature, short circuit). Verify that your battery parameters in the APP match your actual battery configuration.
- Balancing Issues: Ensure the active equalization function is enabled in the APP and that the balance current and differential pressure settings are appropriate for your battery capacity.
- Communication Problems (Bluetooth/RS485/CAN): Verify physical connections. For Bluetooth, ensure the APP is correctly paired. For RS485/CAN, check wiring and communication protocol settings in the APP.
- Heating Function Not Working: Check the heating function status in the APP. Ensure the external temperature control switch (if installed) is functioning correctly and not open-circuiting the heating element.
If problems persist after reviewing these steps, consult the detailed PDF manual or contact JIKONG technical support.
10. User Tips
- Initial Setup: Always perform a thorough check of all wiring, especially balance leads and main power connections, before the first power-up to prevent damage.
- APP Customization: Take advantage of the mobile APP to fine-tune protection parameters to perfectly match your specific battery chemistry and usage requirements.
- Cold Weather Operation: If operating in cold climates, consider utilizing the optional heating function to maintain battery performance and prevent low-temperature protection triggers.
- Monitoring: Regularly check the battery status via the APP to proactively identify and address any potential issues.
11. Warranty and Support
For warranty information and technical support, please refer to the official JIKONG documentation or contact your seller directly. Ensure you retain your proof of purchase for any warranty claims.
PDF Manual Reference: A detailed user manual in PDF format is available for further information. You can access it via the following link: JIKONG BMS User Manual (PDF)