1. Introduction and Overview
The PORTXVNSA VNA-H4 Plus is a portable handheld Vector Network Analyzer (VNA) designed for precise measurement of reflection and transmission coefficients across a wide frequency range. This upgraded version offers enhanced performance and an ergonomically designed exterior, making it an essential tool for HAM radio enthusiasts and RF electronics hobbyists.

2. Key Features
- Ergonomic Design: Features a fully revamped, user-friendly exterior for comfortable handling.
- Extended Measurement Range: Upgraded frequency range from 50KHz to 2.7GHz.
- Enhanced Scanning Points: Increased to 401 scanning points for more detailed analysis.
- Data Storage & Export: Supports SD card for saving test data and easy export.
- Intuitive Interface: Resistive touch screen functionality combined with an upgraded large control knob for convenient operation.
- Long Battery Life: Built-in 5000mAh lithium battery provides extended runtime.
- High-Quality Display: 4-inch IPS LCD display with wide viewing angles, accurate color reproduction, high contrast, and uniform brightness.
- PC Control: Connects via Type-C port for PC control using Nano Saver software, allowing for saving Touchstone files, sweeping frequency spans, and analyzing data.




3. Package Contents
Ensure all items listed below are present in your package:
- 1x PORTXVNSA VNA-H4 Plus Mainframe
- 1x USB Type-C cable
- 2x 15 cm SMA Male-to-Male TG316 RF cables
- 1x SMA Male Calibration Kit OPEN
- 1x SMA Male Calibration Kit SHORT
- 1x SMA Male Calibration Kit LOAD
- 1x SMA Female-to-Female adapter
- 1x Type-C to Type-C cable
- 1x Stylus pen
- 1x Pick (for opening/disassembly, if needed)

4. Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 50KHz – 2.7GHz |
| Dynamic Range (50KHz-900MHz) | 80dB |
| Dynamic Range (900MHz-1.5GHz) | 60dB |
| Dynamic Range (1.5GHz-2.7GHz) | 50dB |
| Reflection Coefficient (SWR) | < 1.1 |
| Frequency Accuracy | < 0.5 ppm |
| Frequency Stability | < 2.5 ppm |
| Scan Points | 401 |
| Dimensions | 160 x 92 x 35mm |
| Battery | Built-in 5000mAh Lithium Battery |
| Display | 4-inch IPS LCD, Resistive Touch Screen |
| Connectivity | USB Type-C Port |
| Storage | SD Card Support |
5. Setup Guide
- Unpacking: Carefully remove the VNA-H4 Plus and all accessories from the packaging. Verify that all components listed in Section 3 are present.
- Initial Charge: Before first use, connect the VNA-H4 Plus to a suitable USB power source using the provided USB Type-C cable. Allow the device to fully charge. The charging indicator will show the battery status.
- Power On: Locate the power button (usually on the top or side) and press it to turn on the device.
- SD Card Insertion (Optional): If you plan to save measurement data, insert a compatible SD card into the designated slot.
- Accessory Connection: Connect the appropriate SMA Male-to-Male RF cables and calibration kits (OPEN, SHORT, LOAD) to the CH0 and CH1/S21 ports as required for your specific measurement task. Use the SMA Female-to-Female adapter if needed.
6. Operating Instructions
The VNA-H4 Plus features both a resistive touch screen and a large control knob for navigation and input.
6.1 Basic Navigation
- Touch Screen: Use the included stylus pen or your finger to tap on menu options and input values.
- Control Knob: Rotate the knob to scroll through menus or adjust values. Press the knob to select an option or confirm an input.
6.2 Menu Structure and Functions
The device's software functionality is organized into several main menus. Refer to the diagram below for a visual representation of the menu hierarchy.

6.3 Performing Measurements
- Calibration: Before any critical measurement, perform a calibration using the provided calibration kits (OPEN, SHORT, LOAD). Navigate to the 'CALIBRATE' menu and follow the on-screen instructions. Proper calibration ensures accurate results.
- Setting Frequency Range: In the 'STIMULUS' menu, set the desired START and STOP frequencies for your scan. You can also adjust the number of 'SWEEP POINTS' (up to 401) for finer resolution.
- Displaying Data: Use the 'DISPLAY' menu to select the type of measurement you wish to view (e.g., S11 LogMag, S21 LogMag, Smith Chart, SWR, Resistance, Reactance).
- Marker Usage: Utilize the 'MARKER' function to pinpoint specific frequencies and read precise values on the graph. You can set multiple markers and perform delta measurements.
- Saving Data: To save your measurement data, navigate to the 'SD CARD' menu and select 'SAVE S1P' or 'SAVE S2P' for Touchstone files, or 'SCREENSHOT' to save an image of the display.
6.4 Common Measurement Applications
- Antenna System Scanning: Analyze the performance of antennas across their operating frequency range.
- SWR and Impedance Matching: Measure Standing Wave Ratio (SWR) and impedance to optimize antenna tuning and matching networks.
- Duplexer Measurement: Evaluate dual-band and triple-band duplexers.
- Port Isolation: Measure isolation between different ports by frequency band.
- Filter Insertion Loss: Determine the insertion loss of filters.
- Cable Length Measurement: Use Time Domain Reflectometry (TDR) features to measure cable lengths and identify faults.



6.5 Video Demonstration
For a visual guide on operating the VNA-H4 Plus, please watch the official demonstration video:
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using harsh chemicals or abrasive materials.
- Battery Care: To prolong battery life, avoid fully discharging the device frequently. Store the device with a partial charge if it will not be used for an extended period.
- Storage: Store the VNA-H4 Plus in a cool, dry place, away from direct sunlight and extreme temperatures.
- Connector Care: Keep SMA connectors clean and free from dust or debris. Use protective caps when not in use.
8. Troubleshooting
- Device Not Powering On: Ensure the battery is sufficiently charged. Connect to a power source and try again.
- Inaccurate Measurements: Perform a full calibration with the provided calibration kits. Check all cable connections for tightness and integrity.
- Touch Screen Unresponsive: Try restarting the device. If the issue persists, ensure the stylus is being used correctly or try a gentle touch with a clean finger.
- Data Not Saving to SD Card: Verify that an SD card is properly inserted and has sufficient free space. Check if the SD card is formatted correctly (FAT32 is generally recommended).
9. User Tips
- Efficient Navigation: Utilize both the resistive touch screen and the physical knob for quick and precise menu navigation and value adjustments.
- Regular Calibration: Always perform a calibration before taking critical measurements, especially when changing frequency ranges or connecting different test setups, to ensure the highest accuracy.
- Data Management: Regularly save your measurement data to an SD card. This allows for detailed post-analysis on a computer using compatible software like Nano Saver.
- Firmware Updates: Check the manufacturer's website periodically for firmware updates to ensure you have the latest features and performance improvements.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.